ParesisVAST-LDHNCT07763522
Validation of a Methodology Using Isometric Dynamometer for Ankle STrength Assessment to Quantify LDH-induced Paresis
A study testing Strength test validity and reliability in people with Paresis and Lumbar Disc Herniation, run by Helsinki University Central Hospital at 1 site in Finland.
Trial summary
Lumbar disc herniation (LDH) is a common condition that may cause lower limb motor weakness (paresis), particularly affecting ankle dorsiflexion and plantarflexion. Although motor deficits are clinically important and may influence treatment decisions, objective and standardized methods for quantifying the severity of… Read more about this study
- Who is it for?
- Ages 18 to 65 yearsHealthy volunteers can take part
- Conditions the study is for
- Paresis, Lumbar Disc Herniation
- What is being tested?
- Strength test validity and reliability
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 70 participants
- Where
- 1 siteFinland
- Study dates
- 10 Aug 2026to Dec 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 65 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Aged 18-65 years old
- No pathology affecting ankle dorsiflexion or plantarflexion strength
- Aged 18-65 years old
- LDH-induced muscle weakness of ankle dorsiflexion or plantarflexion
Who cannot join
- Pathology affecting ankle dorsiflexion or plantarflexion strength
- Second phase
- No muscle weakness induced by herniated lumbar disc
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
About this study
Official title: Validation of a Methodology Using Isometric Dynamometer for Ankle Strength Assessment to Quantify LDH-induced Paresis
Lumbar disc herniation (LDH) is a common condition that may cause lower limb motor weakness (paresis), particularly affecting ankle dorsiflexion and plantarflexion. Although motor deficits are clinically important and may influence treatment decisions, objective and standardized methods for quantifying the severity of paresis are lacking. Current clinical assessment mainly relies on manual muscle testing, which is subjective and has limited sensitivity, while isokinetic dynamometry, the reference standard for muscle strength assessment, is expensive and impractical for routine clinical use.
This prospective validation study aims to evaluate a clinically feasible isometric ankle strength measurement method based on a handheld dynamometer fixed with an external strap to eliminate examiner-dependent resistance. The study will be conducted in two sequential phases. First, validity and reliability of the method will be established in healthy adult volunteers by comparing measurements with those obtained using an isokinetic dynamometer. Second, the method will be applied in patients with LDH-induced lower limb paresis to determine its performance across a broader range of muscle strength values and its clinical applicability.
Read more
Outcome measures include maximal isometric ankle dorsiflexion and plantarflexion force, time to peak force, manual muscle testing (Medical Research Council scale), patient-reported weakness using a Numeric Rating Scale, Lower Extremity Functional Scale (LEFS) scores, and functional ankle strength tests. Validity will be assessed using correlation analyses and Bland-Altman agreement analysis, while intra- and inter-rater reliability will be evaluated using intraclass correlation coefficients, coefficient of variation, standard error of measurement, and minimum detectable change.
The study seeks to establish a reliable, valid, and clinically practical method for objective assessment of ankle muscle strength in patients with LDH-induced paresis. Such a method could improve clinical evaluation, enable objective monitoring of recovery, facilitate future clinical research, and support treatment decision-making.
Read the detailed description
Lumbar disc herniation (LDH) is one of the most common causes of lumbar radiculopathy and may result in lower limb motor weakness due to nerve root compression. While radicular pain often improves with conservative treatment, motor deficits may persist, recover slowly, or require surgical intervention. Despite the clinical importance of paresis, objective quantification of muscle weakness remains challenging because no standardized, practical, and validated measurement method is routinely available for clinical use.
Current clinical assessment primarily relies on manual muscle testing (MMT), which uses an ordinal grading system and is inherently subjective. MMT is limited by examiner experience, strength, and the inability to detect small but clinically meaningful changes in muscle function. Isokinetic dynamometry is widely regarded as the reference standard for objective muscle strength assessment because of its high accuracy and reproducibility. However, the equipment is expensive, non-portable, requires specialized training, and is therefore unsuitable for routine outpatient assessment or repeated follow-up measurements.
This study aims to validate a portable isometric ankle strength measurement method using a handheld dynamometer secured with an external fixation strap, minimizing examiner-related variability. The ultimate goal is to develop a clinically feasible method capable of objectively quantifying ankle dorsiflexion and plantarflexion strength in patients with LDH-induced paresis.
The study is designed as a prospective observational validation study conducted at Helsinki University Hospital. It consists of two consecutive phases.
During the first phase, healthy adult volunteers will undergo repeated ankle strength measurements using both the investigational handheld dynamometer method and an isokinetic dynamometer. This phase will establish criterion validity by comparing the handheld measurements with the reference standard. In addition, intra-rater and inter-rater reliability of the handheld method will be assessed through repeated measurements performed by different examiners.
If adequate validity and reliability are demonstrated, the second phase will recruit patients diagnosed with lumbar disc herniation presenting with clinically verified lower limb paresis. The objective of this phase is to evaluate whether the measurement method performs across the full spectrum of muscle weakness encountered in clinical practice and to determine its clinical relevance.
Primary measurements include maximal isometric ankle dorsiflexion and plantarflexion force and time to peak force. Secondary assessments include manual muscle testing according to the Medical Research Council grading system, patient-reported weakness using an 11-point Numeric Rating Scale, Lower Extremity Functional Scale (LEFS), and functional performance tests consisting of repeated toe raises and heel raises.
Criterion validity will be evaluated by comparing handheld dynamometer measurements with isokinetic dynamometer measurements using Pearson or Spearman correlation coefficients, linear regression analyses, and Bland-Altman plots to assess agreement and systematic bias. Construct validity will be examined by correlating objective strength measurements with patient-reported weakness, LEFS scores, and functional performance tests. Reliability will be assessed using intraclass correlation coefficients for both intra-rater and inter-rater agreement, together with coefficient of variation, standard error of measurement, and minimum detectable change.
Approximately 35 healthy volunteers and 35 patients with LDH-induced paresis will be recruited to allow for participant dropout while maintaining adequate statistical power based on previous validation studies.
The study involves no therapeutic intervention and poses minimal risk. Participants will undergo standardized muscle strength testing and complete patient-reported outcome measures. Any discomfort, such as muscle cramps or transient fatigue during testing, will be documented. Participants demonstrating clinically significant deterioration in muscle strength during the study will be referred for further clinical evaluation according to standard practice.
By establishing a valid, reliable, and practical method for objective ankle strength assessment, this study aims to improve the evaluation and longitudinal monitoring of patients with LDH-induced paresis. The validated methodology may facilitate future clinical trials, improve outcome assessment, enable earlier recognition of neurological recovery or deterioration, and support evidence-based treatment decisions in patients with lumbar disc herniation.
- Conditions
- Paresis, Lumbar Disc Herniation
- Being tested
- Strength test validity and reliability
- Keywords
- dynamometry, paresis, strength measurement
- Medical subject headings
- Paresis, Intervertebral Disc Displacement
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Strength test validity and reliabilityDevice
Ankle dorsiflexion and plantarflexion isometric maximal voluntary contraction strength test
| Study group | Role | What they receive |
|---|---|---|
| Study participant | Other | Person participating in validity and reliability assessment Receives: Device: Strength test validity and reliability |
What is being measured
The primary outcome is the main question the study is designed to answer.
Criterion validity of the isometric handheld dynamometer
Agreement between the investigational isometric handheld dynamometer (HHD) measurement method and the reference standard isokinetic dynamometer (IKD) for maximal ankle dorsiflexion and plantarflexion strength.
Measured: At baseline (first measurement session; Day 0)
Construct validity of the handheld dynamometer
Correlation of HHD measurements with patient-reported weakness (Numerical Rating Scale), Lower Extremity Functionality Scale questionnaire, manual muscle testing (Medical Research Council grade) and functional ankle performance tests.
Measured: At baseline (first measurement session; Day 0)
Intra-rater reliability of the handheld dynamometer
Test-retest reliability of ankle dorsiflexion and plantarflexion strength measurements obtained by the same examiner.
Measured: At baseline (Day 0) and at the second measurement session, within 7 days after baseline
Inter-rater reliability of the handheld dynamometer
Agreement between measurements performed by different examiners
Measured: At the second measurement session, within 7 days after baseline
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Aug 2026
- Study start10 Aug 2026 (estimated)
- Primary completionOct 2026 (estimated)
- Study completionDec 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for ParesisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 70 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Helsinki University Central Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Teppo Jarvinen, Helsinki University Central Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07763522
- Sponsor's protocol ID
- HUS/418/2026
- Acronym
- VAST-LDH
- Status last verified
- Aug 2026
- First submitted
- 8 Jul 2026
- Last updated
- 13 Aug 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: De-identified individual participant data underlying the results reported in the publication, including ankle strength measurements, functional outcome measures, and participant characteristics.
Study at a glance
From the registry record, last updated by the sponsor on 13 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Validation of a Methodology Using Isometric Dynamometer for Ankle Strength Assessment to Quantify LDH-induced Paresis
- ClinicalTrials.gov ID
- NCT07763522
- Acronym / sponsor ID
- VAST-LDH / HUS/418/2026
- Conditions
- Paresis, Lumbar Disc Herniation
- Keywords
- dynamometry, paresis, strength measurement
- Study type
- Interventional
- Recruitment status
- Enrolling by invitation
- Enrolment
- 70 participants (estimated)
- Lead sponsor
- Helsinki University Central HospitalUniversity, hospital or other
- Study start
- 10 Aug 2026 (estimated)
- Primary completion
- Oct 2026 (estimated)
- Study completion
- Dec 2026 (estimated)
- First posted
- 13 Aug 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Lumbar disc herniation (LDH) is a common condition that may cause lower limb motor weakness (paresis), particularly affecting ankle dorsiflexion and plantarflexion. Although motor deficits are clinically important and may influence treatment decisions, objective and standardized methods for quantifying the severity of paresis are lacking. Current clinical assessment mainly relies on manual muscle testing, which is subjective and has limited sensitivity, while isokinetic dynamometry, the reference standard for muscle strength assessment, is expensive and impractical for routine clinical use.
This prospective validation study aims to evaluate a clinically feasible isometric ankle strength measurement method based on a handheld dynamometer fixed with an external strap to eliminate examiner-dependent resistance. The study will be conducted in two sequential phases. First, validity and reliability of the method will be established in healthy adult volunteers by comparing measurements with those obtained using an isokinetic dynamometer. Second, the method will be applied in patients with LDH-induced lower limb paresis to determine its performance across a broader range of muscle strength values and its clinical applicability.
Outcome measures include maximal isometric ankle dorsiflexion and plantarflexion force, time to peak force, manual muscle testing (Medical Research Council scale), patient-reported weakness using a Numeric Rating Scale, Lower Extremity Functional Scale (LEFS) scores, and functional ankle strength tests. Validity will be assessed using correlation analyses and Bland-Altman agreement analysis, while intra- and inter-rater reliability will be evaluated using intraclass correlation coefficients, coefficient of variation, standard error of measurement, and minimum detectable change.
The study seeks to establish a reliable, valid, and clinically practical method for objective assessment of ankle muscle strength in patients with LDH-induced paresis. Such a method could improve clinical evaluation, enable objective monitoring of recovery, facilitate future clinical research, and support treatment decision-making.
Detailed description
Lumbar disc herniation (LDH) is one of the most common causes of lumbar radiculopathy and may result in lower limb motor weakness due to nerve root compression. While radicular pain often improves with conservative treatment, motor deficits may persist, recover slowly, or require surgical intervention. Despite the clinical importance of paresis, objective quantification of muscle weakness remains challenging because no standardized, practical, and validated measurement method is routinely available for clinical use.
Current clinical assessment primarily relies on manual muscle testing (MMT), which uses an ordinal grading system and is inherently subjective. MMT is limited by examiner experience, strength, and the inability to detect small but clinically meaningful changes in muscle function. Isokinetic dynamometry is widely regarded as the reference standard for objective muscle strength assessment because of its high accuracy and reproducibility. However, the equipment is expensive, non-portable, requires specialized training, and is therefore unsuitable for routine outpatient assessment or repeated follow-up measurements.
This study aims to validate a portable isometric ankle strength measurement method using a handheld dynamometer secured with an external fixation strap, minimizing examiner-related variability. The ultimate goal is to develop a clinically feasible method capable of objectively quantifying ankle dorsiflexion and plantarflexion strength in patients with LDH-induced paresis.
The study is designed as a prospective observational validation study conducted at Helsinki University Hospital. It consists of two consecutive phases.
During the first phase, healthy adult volunteers will undergo repeated ankle strength measurements using both the investigational handheld dynamometer method and an isokinetic dynamometer. This phase will establish criterion validity by comparing the handheld measurements with the reference standard. In addition, intra-rater and inter-rater reliability of the handheld method will be assessed through repeated measurements performed by different examiners.
If adequate validity and reliability are demonstrated, the second phase will recruit patients diagnosed with lumbar disc herniation presenting with clinically verified lower limb paresis. The objective of this phase is to evaluate whether the measurement method performs across the full spectrum of muscle weakness encountered in clinical practice and to determine its clinical relevance.
Primary measurements include maximal isometric ankle dorsiflexion and plantarflexion force and time to peak force. Secondary assessments include manual muscle testing according to the Medical Research Council grading system, patient-reported weakness using an 11-point Numeric Rating Scale, Lower Extremity Functional Scale (LEFS), and functional performance tests consisting of repeated toe raises and heel raises.
Criterion validity will be evaluated by comparing handheld dynamometer measurements with isokinetic dynamometer measurements using Pearson or Spearman correlation coefficients, linear regression analyses, and Bland-Altman plots to assess agreement and systematic bias. Construct validity will be examined by correlating objective strength measurements with patient-reported weakness, LEFS scores, and functional performance tests. Reliability will be assessed using intraclass correlation coefficients for both intra-rater and inter-rater agreement, together with coefficient of variation, standard error of measurement, and minimum detectable change.
Approximately 35 healthy volunteers and 35 patients with LDH-induced paresis will be recruited to allow for participant dropout while maintaining adequate statistical power based on previous validation studies.
The study involves no therapeutic intervention and poses minimal risk. Participants will undergo standardized muscle strength testing and complete patient-reported outcome measures. Any discomfort, such as muscle cramps or transient fatigue during testing, will be documented. Participants demonstrating clinically significant deterioration in muscle strength during the study will be referred for further clinical evaluation according to standard practice.
By establishing a valid, reliable, and practical method for objective ankle strength assessment, this study aims to improve the evaluation and longitudinal monitoring of patients with LDH-induced paresis. The validated methodology may facilitate future clinical trials, improve outcome assessment, enable earlier recognition of neurological recovery or deterioration, and support evidence-based treatment decisions in patients with lumbar disc herniation.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Study participant | Other | Device: Strength test validity and reliabilityPerson participating in validity and reliability assessment |
Who may qualify
- Ages
- 18 to 65 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Aged 18-65 years old
- No pathology affecting ankle dorsiflexion or plantarflexion strength
- Aged 18-65 years old
- LDH-induced muscle weakness of ankle dorsiflexion or plantarflexion
Key exclusion criteria (3 listed)
- Pathology affecting ankle dorsiflexion or plantarflexion strength
- Second phase
- No muscle weakness induced by herniated lumbar disc
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Strength test validity and reliabilityAnkle dorsiflexion and plantarflexion isometric maximal voluntary contraction strength test | Device | Study participant |
Primary outcome
Criterion validity of the isometric handheld dynamometer
Time frame: At baseline (first measurement session; Day 0)
Agreement between the investigational isometric handheld dynamometer (HHD) measurement method and the reference standard isokinetic dynamometer (IKD) for maximal ankle dorsiflexion and plantarflexion strength.
Construct validity of the handheld dynamometer
Time frame: At baseline (first measurement session; Day 0)
Correlation of HHD measurements with patient-reported weakness (Numerical Rating Scale), Lower Extremity Functionality Scale questionnaire, manual muscle testing (Medical Research Council grade) and functional ankle performance tests.
Intra-rater reliability of the handheld dynamometer
Time frame: At baseline (Day 0) and at the second measurement session, within 7 days after baseline
Test-retest reliability of ankle dorsiflexion and plantarflexion strength measurements obtained by the same examiner.
Inter-rater reliability of the handheld dynamometer
Time frame: At the second measurement session, within 7 days after baseline
Agreement between measurements performed by different examiners
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 Aug 2026.
- Individual participant dataSharing planned: Yes. De-identified individual participant data underlying the results reported in the publication, including ankle strength measurements, functional outcome measures, and participant characteristics.
Related trials for Paresis
Active, not recruitingObservational study
Nerve Transfer Surgery to Restore Upper-limb Function After Cervical Spinal Cord Injury
Spinal Cord Injury, Spinal Cord Injury at C5-C7 Level
RecruitingPhase 1
Study of Anitocabtagene Autoleucel in Participants With Non-Oncology Plasma Cell-Related Diseases
Muscular Diseases, Neuromuscular Manifestations
Recruiting
Repetitive Transcranial Magnetic Stimulation (rTMS) in MS Induced Spastic Paraparesis
Multiple Sclerosis
RecruitingPhase 1/2
PBGENE-DMD Phase 1/2a Safety and Preliminary Efficacy Study in Duchenne Muscular Dystrophy (FUNCTION-DMD)
Duchenne Muscular Dystrophy With Mutations Amenable to PBGENE-DMD
Not yet recruiting
Haptic-Assisted Virtual Reality Upper-Limb Rehabilitation After Intracerebral Haemorrhage
Intracerebral Hemorrhage, Hemorrhagic Stroke
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Strength test validity and reliability in people with Paresis and Lumbar Disc Herniation, run by Helsinki University Central Hospital at 1 site in Finland.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: enrolling by invitation, as of the sponsor's last update on 13 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Finland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Criterion validity of the isometric handheld dynamometer (time frame: At baseline (first measurement session; Day 0)). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Aug 2026.