AzTrials
AzTrials

TracheostomyNCT07701226

Novel Tracheostomy Tube Fixation Device in Oral Cancer Patients

A study testing Novel Self-Adhesive Bidirectional Tracheostomy Tube Fixation Device and Routine Tracheostomy Care and Conventional Fixation in people with Tracheostomy and Oral Cancer, run by Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study evaluated a novel tracheostomy tube fixation device in post-tracheostomy patients with oral cancer. After tracheostomy, conventional fixation methods may be associated with skin pressure injury, wound contamination, frequent dressing changes, tube displacement, and patient discomfort. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Tracheostomy, Oral Cancer, Post-Tracheostomy Care
What is being tested?
Novel Self-Adhesive Bidirectional Tracheostomy Tube Fixation Device and Routine Tracheostomy Care and Conventional Fixation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
150 participants
Where
1 siteChina
Study dates
7 May 2025to 31 Oct 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients aged 18 years or older.
  • Patients with oral cancer who underwent tracheostomy or required a tracheostomy tube during hospitalization.
  • Patients who were conscious and had normal comprehension and communication ability.
  • Patients with intact cervical skin without skin damage, skin disease, or infection.
  • Patients who voluntarily agreed to participate and provided written informed consent.

Who cannot join

  • Patients with pre-existing pressure injury, skin damage, allergy, or infection in the anterior cervical region before tracheostomy.
  • Pregnant women.
  • Minors under 18 years of age.
  • Patients with psychiatric disorders.
  • Patients who were unable to cooperate with the study procedures or outcome assessments as judged by the investigators.

Trial locations and contacts

1 site in 1 country.

China1 site
  • Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine

    Shanghai, Shanghai Municipality, 200011

Other trials in China

About this study

Official title: Effect of a Novel Tracheostomy Tube Fixation Device on Nursing Efficiency, Complication Rates, and Patient Comfort in Post-Tracheostomy Patients: A Randomized Controlled Trial

This study evaluated a novel tracheostomy tube fixation device in post-tracheostomy patients with oral cancer. After tracheostomy, conventional fixation methods may be associated with skin pressure injury, wound contamination, frequent dressing changes, tube displacement, and patient discomfort. The novel fixation device was designed to provide stable tube fixation, protect the cervical skin, facilitate wound care, and improve patient comfort.

A total of 150 eligible patients who underwent tracheostomy were randomly assigned to a treatment group or a control group. Patients in the control group received routine tracheostomy care and conventional fixation. Patients in the treatment group received the novel self-adhesive bidirectional tracheostomy tube fixation device in addition to routine tracheostomy care.

The study assessed whether the novel fixation device could reduce tracheostomy-related complications, improve nursing efficiency, reduce the frequency and duration of wound care, improve neck comfort, and maintain safe tracheostomy tube fixation.

Read the detailed description

Tracheostomy is commonly performed in patients who require airway management after oral and maxillofacial head and neck tumor surgery. Stable fixation of the tracheostomy tube and appropriate wound care are important for maintaining airway safety, reducing local complications, and improving patient comfort. Conventional fixation methods, such as gauze ties or routine fixation straps, may become contaminated by blood or secretions, may cause friction or pressure on the cervical skin, and may require frequent replacement. These issues can increase nursing workload and may contribute to local skin injury, infection, tube displacement, or patient discomfort.

This randomized controlled trial was designed to evaluate the clinical application value and efficacy of a novel self-adhesive bidirectional tracheostomy tube fixation device. The device is intended to provide stable tracheostomy tube fixation while facilitating wound observation, dressing replacement, and daily nursing care.

Eligible patients were post-tracheostomy patients with oral cancer who were conscious, had adequate comprehension and communication ability, had intact cervical skin without infection or skin disease, and provided informed consent. Patients with pre-existing pressure injury, skin damage, allergy, or infection in the anterior cervical region before tracheostomy, pregnant women, minors, and patients with psychiatric disorders were excluded.

Participants were randomly assigned to two groups. The control group received routine tracheostomy care, including conventional tube fixation, nebulization therapy as prescribed, sputum suctioning as needed, regular inner cannula cleaning, and routine sterile gauze dressing care. The treatment group received routine tracheostomy care plus the novel self-adhesive bidirectional tracheostomy tube fixation device. The device was replaced once daily, or earlier if blood or exudate soaked two-thirds of the device.

The primary outcome was the occurrence of infection or inflammatory signs around the tracheostomy wound, including redness, swelling, heat, and pain. Secondary outcomes included the frequency of device or dressing replacement, duration of each wound care procedure, new cervical skin injury, tracheostomy tube displacement, and patient-reported neck comfort. Safety assessments included changes in oxygen saturation before and after use and the recording of adverse events, including tube dislodgement.

The purpose of this study was to determine whether the novel tracheostomy tube fixation device could improve nursing efficiency, reduce tracheostomy-related complications, and improve patient comfort compared with conventional fixation and routine tracheostomy care.

Being tested
Novel Self-Adhesive Bidirectional Tracheostomy Tube Fixation Device, Routine Tracheostomy Care and Conventional Fixation
Keywords
Novel Tracheostomy Tube Fixation Device, Tracheostomy Tube Fixation, Tracheostomy Care, Airway Rehabilitation, Nursing Efficiency, Complication Rate, Patient Comfort, Tracheostomy Wound Care, Cervical Skin Injury, Tube Displacement, Oral Cancer Patients, Randomized Controlled Trial
Medical subject headings
Mouth Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Novel Self-Adhesive Bidirectional Tracheostomy Tube Fixation DeviceDevice

    The novel self-adhesive bidirectional tracheostomy tube fixation device was used for tracheostomy tube fixation in addition to routine tracheostomy care. After drying the wound area, the device was placed between the patient and the tracheostomy tube, with the posterior side attached to the cervical skin. The anterior hook-and-loop components were passed through the fixation wings of the tracheostomy tube and adjusted to secure the tube. The device was replaced once daily, or earlier if blood or exudate soaked two-thirds of the device.

  • Routine Tracheostomy Care and Conventional FixationOther

    Routine tracheostomy care included conventional tracheostomy tube fixation, nebulization therapy as prescribed, sputum suctioning as needed, regular cleaning or replacement of the inner cannula, and sterile gauze dressing care. Conventional fixation was performed using gauze ties or routine fixation straps around the neck with appropriate tightness. The tracheostomy wound dressing was changed twice daily or earlier if blood or exudate soaked two-thirds of the gauze dressing.

Study groups in NCT07701226
Study groupRoleWhat they receive
Treatment GroupExperimentalParticipants in the treatment group received routine tracheostomy care plus a novel self-adhesive bidirectional tracheostomy tube fixation device. The device was applied for tracheostomy tube fixation and was replaced once daily, or earlier if blood or exudate soaked two-thirds of the device.
Receives: Device: Novel Self-Adhesive Bidirectional Tracheostomy Tube Fixation Device; Other: Routine Tracheostomy Care and Conventional Fixation
Control GroupActive comparatorParticipants in the control group received routine tracheostomy care and conventional tracheostomy tube fixation. Routine care included nebulization therapy as prescribed, sputum suctioning as needed, regular cleaning or replacement of the inner cannula, and sterile gauze dressing care.
Receives: Other: Routine Tracheostomy Care and Conventional Fixation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Incidence of Tracheostomy Wound Infection

    The occurrence of infection or inflammatory signs around the tracheostomy wound was assessed, including redness, swelling, heat, and pain around the tracheostomy site.

    Measured: From intervention initiation to hospital discharge, up to 14 days

Secondary outcomes (5)
  1. Frequency of Dressing or Device Replacement

    The number of dressing or fixation device replacements was recorded. Replacement was performed once daily or earlier if blood or exudate soaked two-thirds of the dressing or device.

    Measured: From intervention initiation to hospital discharge, up to 14 days

  2. Duration of Each Dressing or Device Replacement Procedure

    The time required for each dressing or fixation device replacement procedure was recorded. Timing started when the dressing or device replacement began and ended after the fixation device or dressing was properly adjusted and secured.

    Measured: From intervention initiation to hospital discharge, up to 14 days

  3. Incidence of New Cervical Skin Injury

    New cervical skin injury around the tracheostomy tube fixation area was recorded, including newly developed pressure injury, skin redness, skin breakdown, or other fixation-related skin damage.

    Measured: From postoperative day 1 to hospital discharge, up to 14 days

  4. Incidence of Tracheostomy Tube Displacement

    Tracheostomy tube displacement was assessed by marking the skin incision site as 0 cm. Tube movement of 0.8 cm or less was considered displacement according to the study protocol.

    Measured: From intervention initiation to hospital discharge, up to 14 days

  5. Patient-Reported Neck Comfort Score

    Patient-reported neck comfort was assessed using a 0-to-10 scale. Conscious patients were asked to describe their wearing experience, with scores of 0 to 2 indicating comfort and scores of 3 to 10 indicating discomfort.

    Measured: From intervention initiation to hospital discharge, up to 14 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Jul 2026
  2. Study start7 May 2025
  3. Primary completion31 Oct 2025
  4. Study completion31 Oct 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Parallel groups
Model description
This is a two-arm, parallel, randomized controlled trial. Eligible post-tracheostomy patients were randomly assigned to either the treatment group or the control group. The control group received routine tracheostomy care and conventional fixation, while the treatment group received routine tracheostomy care plus a novel self-adhesive bidirectional tracheostomy tube fixation device.
Masking
None (open label)
Enrolment
150 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07701226
Sponsor's protocol ID
SH9H-TRACH-FIX-2025
Status last verified
Jul 2026
First submitted
9 Jul 2026
Last updated
14 Jul 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: De-identified individual participant data underlying the main study results will be shared after removal of personal identifiers. Shared data may include baseline characteristics, intervention records, outcome measures, and adverse event data. No names, hospital identification numbers, contact information, or other personally identifiable information will be shared.

Questions about this trial

What is this clinical trial studying?

A study testing Novel Self-Adhesive Bidirectional Tracheostomy Tube Fixation Device and Routine Tracheostomy Care and Conventional Fixation in people with Tracheostomy and Oral Cancer, run by Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 14 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Incidence of Tracheostomy Wound Infection (time frame: From intervention initiation to hospital discharge, up to 14 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jul 2026; AzTrials last refreshed its copy on 8 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in