AzTrials
AzTrials

Non-Carious Cervical Lesions (NCCLs)NCCL-DHNCT07648147

Evaluation of Different Non-Invasive Methods in the Treatment of Dentin Hypersensitivity Associated With Non-Carious Cervical Lesions: A Split-Mouth Clinical Study

A study testing D Blue Diode Laser and ProSylc Bioactive Glass Powder in people with Non-Carious Cervical Lesions (NCCLs) and Dentin Hypersensitivity, run by Cukurova University at 1 site in Turkey (Türkiye).

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The aim of this split-mouth clinical study is to compare the effectiveness of D Blue diode laser application and ProSylc bioactive glass powder application in reducing dentin hypersensitivity in patients with non-carious cervical lesions (NCCLs). Read more about this study

Who is it for?
Ages 18 to 65 years
What is being tested?
D Blue Diode Laser and ProSylc Bioactive Glass Powder
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteTurkey (Türkiye)
Study dates
20 Jul 2026to 20 Jan 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Individuals aged between 18 and 65 years. Systemically healthy individuals. Individuals with dentin hypersensitivity. Presence of two permanent teeth with similar severity of dentin hypersensitivity in the same participant.
  • Participants who agree to participate in the study and sign the informed consent form

Who cannot join

  • Presence of active caries in the study teeth. Presence of cervical restoration in the study teeth. Presence of pulpal pathology. History of desensitizing treatment within the last 3 months. Pregnancy. Presence of systemic disease. Use of analgesics within the last 48 hours.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Hüsna Selinay S Dağdelen, Doctor of Dental Medicine contact

+905453051080

selinay428@gmail.com

Ezgi S Sonkaya Akburak, Associate Professor Doctor contact

+905054974631

sonkayaezgi@yahoo.com

Turkey (Türkiye)1 site
  • Çukurova University

    Adana, sarıçam, 01250

Other trials in Turkey (Türkiye)

About this study

Official title: EVALUATION OF DIFFERENT NON-INVASIVE METHODS IN THE TREATMENT OF DENTIN HYPERSENSITIVITY ASSOCIATED WITH NON-CARIOUS CERVICAL LESIONS: A SPLIT-MOUTH CLINICAL STUDY

The aim of this split-mouth clinical study is to compare the effectiveness of D Blue diode laser application and ProSylc bioactive glass powder application in reducing dentin hypersensitivity in patients with non-carious cervical lesions (NCCLs). Different treatment modalities will be applied within the same participant, and changes in dentin hypersensitivity will be evaluated following treatment. The primary outcome measure will be the reduction in dentin hypersensitivity after the interventions. The findings of this study are expected to contribute to the identification of effective non-invasive treatment approaches for the management of dentin hypersensitivity associated with non-carious cervical lesions.

Read the detailed description

This split-mouth clinical study was designed to compare the clinical effectiveness of two different non-invasive approaches used in the treatment of dentin hypersensitivity associated with non-carious cervical lesions (NCCLs). Dentin hypersensitivity is a common clinical condition characterized by a short, sharp pain arising from exposed dentin in response to thermal, evaporative, tactile, osmotic, or chemical stimuli. Non-carious cervical lesions play a significant role in the development of dentin hypersensitivity by exposing dentin surfaces to the oral environment.

In this study, the effectiveness of D Blue diode laser application and ProSylc bioactive glass powder application in reducing dentin hypersensitivity will be evaluated. The split-mouth study design will allow each participant to serve as their own control, thereby minimizing interindividual variability. Eligible teeth will be allocated to different treatment groups according to the study protocol, and all interventions will be performed following standardized clinical procedures.

The level of dentin hypersensitivity will be assessed before treatment and at predetermined follow-up intervals using standardized clinical evaluation methods. Based on the collected data, the effects of both treatment modalities on dentin hypersensitivity will be compared, and changes over time will be analyzed. In addition, the clinical applicability and patient tolerance of the interventions will be evaluated.

The findings of this study are expected to contribute to the existing literature regarding the effectiveness of non-invasive treatment methods for dentin hypersensitivity associated with non-carious cervical lesions and to provide evidence-based guidance for clinicians in selecting appropriate treatment approaches.

Being tested
D Blue Diode Laser, ProSylc Bioactive Glass Powder
Keywords
Non-Carious Cervical Lesions; Dentin Hypersensitivity; Diode Laser; D Blue Diode Laser; Bioactive Glass; ProSylc; Split-Mouth Study; Non-Invasive Treatment
Medical subject headings
Dentin Sensitivity

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • D Blue Diode LaserDevice

    Also called Diode Laser

    D Blue diode laser application for the treatment of dentin hypersensitivity associated with non-carious cervical lesions.

  • ProSylc Bioactive Glass PowderDevice

    Also called Bioactive Glass Powder

    ProSylc bioactive glass powder application for the treatment of dentin hypersensitivity associated with non-carious cervical lesions.

Study groups in NCT07648147
Study groupRoleWhat they receive
D Blue Diode Laser GroupExperimentalTeeth assigned to this group will receive D Blue diode laser application for the management of dentin hypersensitivity associated with non-carious cervical lesions.
Receives: Device: D Blue Diode Laser
ProSylc Bioactive Glass GroupExperimentalTeeth assigned to this group will receive ProSylc bioactive glass powder application for the management of dentin hypersensitivity associated with non-carious cervical lesions.
Receives: Device: ProSylc Bioactive Glass Powder

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in Dentin Hypersensitivity

    Dentin hypersensitivity will be assessed using a Visual Analog Scale (VAS) following standardized air stimulus application. The change in VAS scores from baseline to follow-up visits will be evaluated.

    Measured: Baseline, immediately after treatment, 1 week, 1 month, and 3 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Jun 2026
  2. Study start20 Jul 2026 (estimated)
  3. Primary completion20 Dec 2026 (estimated)
  4. Study completion20 Jan 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
This study will employ a split-mouth design in which each participant will receive both interventions on different eligible teeth. One side will be treated with D Blue diode laser, while the contralateral side will receive ProSylc bioactive glass powder application. This design allows direct comparison of treatment outcomes within the same individual and minimizes inter-individual variability.
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07648147
Sponsor's protocol ID
Dentin Hypersensivity
Other IDs
18920
Acronym
NCCL-DH
Status last verified
Jun 2026
First submitted
10 Jun 2026
Last updated
15 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing D Blue Diode Laser and ProSylc Bioactive Glass Powder in people with Non-Carious Cervical Lesions (NCCLs) and Dentin Hypersensitivity, run by Cukurova University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 15 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Hüsna Selinay S Dağdelen, Doctor of Dental Medicine (+905453051080, selinay428@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in Dentin Hypersensitivity (time frame: Baseline, immediately after treatment, 1 week, 1 month, and 3 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in