First-in-human Clinical Trial to Assess Safety and Efficacy of the CardiaZn Bioresorbable Stent in Children With Pulmonary Artery Stenosis and Aortic Coarctation

A study testing CardiaZn Bioresorbable Stent in people with Aortic Coarctation, Pulmonary Artery Stenosis, run by PediaStent LLC.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

This study evaluates the safety and effectiveness of the CardiaZn stent, a novel bioresorbable stent designed specifically for infants and children with congenital cardiovascular conditions. Read more about this study

Who is it for?
Ages Up to 8 years
What is being tested?
CardiaZn Bioresorbable Stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
45 participants
Where
No sites listed yet
Study dates
Oct 2026to Dec 2031
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 8 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Subject is aged less than 9 years at the time of the index procedure
  • Subject presents with hemodynamically significant discrete aortic coarctation or pulmonary artery stenosis requiring catheter-based intervention
  • Subject meets angiographic eligibility criteria at the time of the index procedure as assessed by the interventional cardiologist
  • Subject's legally authorized representative has provided written informed consent prior to any study-related procedures
  • Subject's physician has determined that catheter-based intervention is clinically indicated
  • Target vessel anatomy is suitable for stent implantation as assessed by the operator

Who cannot join

  • Subject has complex aortic arch hypoplasia or long segment coarctation not amenable to stent therapy
  • Subject has a known allergy or hypersensitivity to zinc or silver
  • Subject has active systemic infection at the time of the index procedure
  • Subject has a contraindication to cardiac catheterization or general anesthesia
  • Subject has previously received a stent at the target vessel segment
  • Subject has a comorbid condition that in the opinion of the investigator would preclude safe participation in the study or confound study results
  • Subject is currently enrolled in another investigational device or drug study that has not completed its primary endpoint
  • Subject has a life expectancy of less than 12 months in the opinion of the investigator

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Timothy Moran President contact

8886916161

trm242@gmail.com

About this study

Official title: A Prospective Multi-Center, Single Arm, Open Label, Pivotal Clinical Study Designed to Assess the Safety, Performance, and Efficacy of the CardiaZn Stent in the Treatment of Pediatric Aortic Coarctation and Pulmonary Artery Stenosis

This study evaluates the safety and effectiveness of the CardiaZn stent, a novel bioresorbable stent designed specifically for infants and children with congenital cardiovascular conditions. Unlike permanent metal stents, the CardiaZn stent is designed to open narrowed blood vessels and then gradually dissolve, leaving nothing permanently behind. This allows the vessel to grow naturally with the child over time.

The study will enroll children under 9 years of age diagnosed with either pulmonary artery stenosis - a narrowing of the arteries that carry blood from the heart to the lungs - or aortic coarctation - a narrowing of the main artery carrying blood from the heart to the body. Both conditions currently require repeated interventions as children grow, since existing permanent stents cannot accommodate natural vessel growth.

Participants will receive the CardiaZn stent during a standard cardiac catheterization procedure and will be followed for 5 years to assess vessel patency, device performance, and long-term safety outcomes.

Read the detailed description

Background and Clinical Need Pulmonary artery stenosis (PAS) and aortic coarctation (CoA) are among the most common congenital cardiovascular conditions requiring catheter-based intervention in infants and children. Current standard of care involves balloon dilation and implantation of permanent metallic stents. While effective in the short term, permanent stents present a significant limitation in pediatric patients: they cannot accommodate somatic growth, necessitating repeated balloon dilations and re-interventions throughout childhood. Furthermore, permanent metallic implants preclude normal vessel remodeling, restrict MRI imaging quality, and complicate future surgical access.

The unmet clinical need is substantial. A bioresorbable stent that provides acute vessel support, maintains patency through the critical healing phase, and then completely resorbs - leaving no permanent implant - would represent a paradigm shift in the management of pediatric congenital cardiovascular stenoses.

Device Description The CardiaZn stent is a bioresorbable endovascular stent fabricated from a zinc-silver (ZnAg) alloy. Zinc is an essential trace element with well-characterized metabolic pathways, and its corrosion byproducts are biocompatible and cleared through normal physiological mechanisms. The addition of silver enhances mechanical properties including radial strength and corrosion kinetics. The device is balloon-expandable and delivered via standard cardiac catheterization technique.

The ZnAg alloy platform distinguishes CardiaZn from polymer-based bioresorbable scaffolds, which have demonstrated limitations in radial strength and degradation kinetics, and from magnesium-based platforms, which resorb too rapidly for the intended application window. The zinc-silver system is designed to provide sufficient radial support through the vessel healing phase, with a resorption timeline aligned to the biological requirements of pediatric vascular remodeling.

The device is drug-free, relying entirely on the mechanical and biological properties of the ZnAg alloy to achieve its clinical objectives. This drug-free positioning is supported by pediatric case data from magnesium-based platforms demonstrating that bioresorbable metal scaffolds can achieve clinically meaningful outcomes without pharmacological augmentation.

Study Rationale Preclinical evaluation of the CardiaZn stent has included comprehensive in vitro testing, biocompatibility assessment per ISO 10993 standards, and a GLP animal study. Results have demonstrated adequate radial strength, biocompatible corrosion byproduct profile, and vessel patency consistent with the intended clinical application. These data support proceeding to first-in-human evaluation under an FDA Investigational Device Exemption.

Prior FDA engagement through the TAP Pre-Submission program (Q-Submission U230126-A010) established alignment on study design, endpoint selection, and statistical approach prior to IDE submission.

Study Design PEDIASORB is a prospective, multicenter, single-arm, open-label, pivotal clinical study. A total of 45 eligible subjects will be enrolled at up to 11 investigational sites. The study population includes subjects aged under 9 years presenting with hemodynamically significant discrete aortic coarctation or pulmonary artery stenosis.

To ensure balanced representation of both indications, neither the pulmonary artery stenosis nor the aortic coarctation population may contribute more than 70% of total enrollment, ensuring a minimum of 14 subjects per treatment location. At least 50% of enrollments will occur at United States investigational sites.

Patients will be screened for pre-operative eligibility within 60 days prior to the index procedure. Following confirmation of intraoperative eligibility criteria via angiography, eligible subjects will undergo implantation of the CardiaZn stent via standard cardiac catheterization technique.

Follow-Up All subjects will be followed for 5 years post-procedure. Follow-up visits are scheduled at hospital discharge and at months 1, 3, 6, and 12, and annually through year 5. Each follow-up visit includes physical examination, laboratory testing, health status assessment, imaging evaluation, and review of concomitant medications and procedures. CT angiography will be performed in all subjects at 6 months post-procedure.

Adverse events will be collected from initial informed consent through study exit.

Primary Endpoints

The co-primary endpoints are:

Device success at the index procedure, defined as successful delivery and deployment of the CardiaZn stent with achievement of adequate vessel patency as assessed by angiography Freedom from pre-defined procedure- and device-related serious adverse events of interest through 6 months post-procedure

Secondary Endpoints Secondary endpoints include assessment of vessel patency, peak-to-peak pressure gradient, vessel diameter, and freedom from re-intervention through 5 years of follow-up. Long-term safety will be assessed through collection of all adverse events, serious adverse events, and device-related complications through study exit.

Statistical Considerations The study is designed as a single-arm pivotal trial with performance goal comparisons against pre-specified objective performance criteria derived from published literature and historical data for the current standard of care. The sample size of 45 subjects provides adequate statistical power to test the co-primary endpoints at the pre-specified significance level. A formal statistical analysis plan has been developed and is included as an attachment to the IDE submission.

Data Safety Monitoring An independent Data Safety Monitoring Board (DSMB) will provide ongoing oversight of subject safety throughout the trial. A Clinical Events Committee (CEC) will provide independent adjudication of all adverse events and endpoints. Interim analyses will be conducted per the DSMB charter.

Regulatory Background The CardiaZn stent is an investigational device. This study is being conducted under FDA IDE number U230126. Prior FDA engagement was conducted through the TAP Pre-Submission program. The study is sponsored by PediaStent and conducted in accordance with applicable FDA regulations, Good Clinical Practice guidelines, and the principles of the Declaration of Helsinki.

Being tested
CardiaZn Bioresorbable Stent
Keywords
Bioresorbable stent, Pediatric stent, Aortic coarctation, Pulmonary artery stenosis, CardiaZn, PediaStent, PEDIASORB, biodegradable
Medical subject headings
Aortic Coarctation, Stenosis, Pulmonary Artery

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CardiaZn Bioresorbable StentDevice

    The CardiaZn stent is a balloon-expandable bioresorbable endovascular stent fabricated from a zinc-silver (ZnAg) alloy. Zinc is an essential trace element with well-characterized metabolic pathways and biocompatible corrosion byproduct profile. The addition of silver enhances radial strength and optimizes corrosion kinetics for the intended resorption timeline. The device is delivered via standard cardiac catheterization technique under fluoroscopic guidance and is designed to provide acute mechanical support of the stenotic vessel segment following balloon dilation, then gradually resorb completely over time leaving no permanent implant. The device is drug-free.

Study groups in NCT07628101
Study groupRoleWhat they receive
CardiaZn Bioresorbable StentExperimentalAll enrolled subjects will receive the CardiaZn bioresorbable zinc-silver alloy stent, delivered via standard cardiac catheterization technique for the treatment of hemodynamically significant aortic coarctation or pulmonary artery stenosis in subjects aged under 9 years.
Receives: Device: CardiaZn Bioresorbable Stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Device Success at Index Procedure

    Successful delivery and deployment of the CardiaZn stent with achievement of adequate vessel patency defined as less than 30% residual diameter stenosis as assessed by quantitative angiography

    Measured: At index procedure (Day 0)

  2. Freedom from Device- and Procedure-Related Serious Adverse Events

    Freedom from pre-defined procedure- and device-related serious adverse events of interest including vessel perforation, stent thrombosis, stent embolization, stent fracture, and target vessel reintervention

    Measured: 6 months post-procedure

Secondary outcomes (8)
  1. Peak-to-Peak Pressure Gradient

    Change in peak-to-peak pressure gradient across the treated vessel segment as measured by cardiac catheterization

    Measured: Baseline, 6 months, 12 months, annually through 5 years

  2. Minimum Lumen Diameter

    Minimum lumen diameter of the treated vessel segment as assessed by quantitative angiography or CT angiography

    Measured: Baseline, 6 months, 12 months, annually through 5 years

  3. Freedom from Target Vessel Reintervention

    Freedom from any reintervention at the target vessel segment including repeat balloon dilation, repeat stenting, or surgical intervention

    Measured: 6 months, 12 months, annually through 5 years

  4. Freedom from Device- and Procedure-Related Serious Adverse Events

    Freedom from pre-defined procedure- and device-related serious adverse events of interest

    Measured: 12 months, annually through 5 years

  5. Stent Patency

    Binary assessment of stent patency defined as absence of significant in-stent restenosis greater than 50% diameter stenosis as assessed by CT angiography or cardiac catheterization

    Measured: 6 months, 12 months, annually through 5 years

  6. Somatic Growth Accommodation

    Assessment of vessel diameter growth relative to somatic growth parameters including height and weight over the follow-up period

    Measured: 12 months, annually through 5 years

  7. All-Cause Mortality

    Death from any cause

    Measured: 30 days, 6 months, 12 months, annually through 5 years

  8. Device-Related Adverse Events

    All adverse events adjudicated as device-related by the independent Clinical Events Committee

    Measured: From index procedure through 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Jun 2026
  2. Study startOct 2026 (estimated)
  3. Primary completionOct 2031 (estimated)
  4. Study completionDec 2031 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
45 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07628101
Sponsor's protocol ID
PS-001
Other IDs
U230126
Acronym
Pediasorb
Status last verified
May 2026
First submitted
26 May 2026
Last updated
4 Jun 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing CardiaZn Bioresorbable Stent in people with Aortic Coarctation, Pulmonary Artery Stenosis, run by PediaStent LLC.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 4 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Timothy Moran President (8886916161, trm242@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Device Success at Index Procedure (time frame: At index procedure (Day 0)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in