AzTrials
AzTrials

Colo-rectal PolypsNCT07619248

Comparison of the Diagnostic Accuracy Between Three Dimensional and Standard Colonoscopy of Colorectal Polyps

A study testing 3D MonoStereo in people with Colo-rectal Polyps and Colonoscopy, run by National Taiwan University Hospital.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Colorectal cancer (CRC) is one of the most common cancers worldwide. These malignancies originate in the colon or rectum, and the majority evolve from pre-existing colonic adenomas (a type of colon polyp). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Colo-rectal Polyps, Colonoscopy
What is being tested?
3D MonoStereo
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
600 participants
Where
No sites listed yet
Study dates
12 May 2026to 12 May 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients aged 18 years or older.
  • Patients who meet the indications for undergoing colonoscopy.

Who cannot join

  • Patients younger than 18 years of age or those with contraindications precluding them from undergoing a colonoscopy.
  • (Contraindications for colonoscopy: patients with a recent history of myocardial infarction, pulmonary embolism, cerebrovascular infarction, severe unstable cardiovascular disease, acute abdominal inflammation combined with peritonitis, fulminant colitis, acute diverticulitis, colonic perforation, or toxic megacolon).
  • Patients with familial hereditary colorectal cancer or colonic polyposis syndromes.
  • Patients with inflammatory bowel disease (IBD).
  • Subjects who are unable to complete the colonoscopy or those with poor bowel preparation.
  • Subjects who are unable to confirm the date of their previous colonoscopy.

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Li-Chun Chang, MD, PhD contact

+886-972-651-285

lichunchang@ntu.edu.tw

About this study

Colorectal cancer (CRC) is one of the most common cancers worldwide. These malignancies originate in the colon or rectum, and the majority evolve from pre-existing colonic adenomas (a type of colon polyp). Early detection, identification, and removal of these precancerous lesions can effectively reduce the morbidity and mortality of colorectal cancer.

However, not all colonic polyps possess a significant risk of malignant transformation. Polyps can generally be subdivided into "neoplastic" and "non-neoplastic" lesions; major non-neoplastic polyps include inflammatory polyps, hamartomas, lymphoid polyps, mucosal prolapse polyps, and hyperplastic polyps. On the other hand, neoplastic polyps have the potential to develop into malignancies, primarily including adenomatous polyps and serrated polyps. Adenomatous polyps account for more than 50% of all colonic polyps and are the most common precancerous lesions for CRC. Clinically, they can be further classified into tubular, tubulovillous, or villous adenomas based on histological subtypes. As for serrated polyps, traditional serrated adenomas (TSAs) and sessile serrated lesions (SSLs) possess carcinogenic potential.

Read more

During a colonoscopy, detecting colonic polyps is crucial, but it is equally important to identify which polyps have malignant potential. This allows for the accurate resection of true precancerous lesions while avoiding the procedural risks associated with unnecessary polypectomies. Furthermore, in rare instances, diminutive polyps may harbor cancer with deep submucosal invasion. Due to the risks of incomplete resection and lymph node metastasis, such lesions are not suitable for endoscopic resection. Therefore, achieving an accurate endoscopic diagnosis is a key step in determining the most appropriate management strategy for colonic polyps.

To improve the diagnostic accuracy of endoscopy for colonic polyps, multiple modalities have been developed, including careful observation of lesion morphology, as well as various image-enhanced technologies and chromoendoscopy. Meanwhile, three-dimensional (3D) endoscopy, a novel technology, offers superior spatial resolution and depth perception compared to conventional two-dimensional (2D) endoscopy. Studies have confirmed that 3D endoscopy can improve the adenoma detection rate (ADR) due to its enhanced ability to detect flat and inconspicuous lesions. However, whether 3D colonoscopy can also enhance the endoscopic diagnostic accuracy for colonic polyps remains to be explored. Therefore, we designed a randomized controlled trial (RCT) to investigate whether 3D colonoscopy can improve the diagnostic accuracy of colonic polyps compared to conventional 2D colonoscopy.

Read the detailed description

Colorectal cancer (CRC) is one of the most common cancers worldwide. These malignancies originate in the colon or rectum, and the majority evolve from pre-existing colonic adenomas (a type of colon polyp). Early detection, identification, and removal of these precancerous lesions can effectively reduce the morbidity and mortality of colorectal cancer.

However, not all colonic polyps possess a significant risk of malignant transformation. Polyps can generally be subdivided into "neoplastic" and "non-neoplastic" lesions; major non-neoplastic polyps include inflammatory polyps, hamartomas, lymphoid polyps, mucosal prolapse polyps, and hyperplastic polyps. On the other hand, neoplastic polyps have the potential to develop into malignancies, primarily including adenomatous polyps and serrated polyps. Adenomatous polyps account for more than 50% of all colonic polyps and are the most common precancerous lesions for CRC. Clinically, they can be further classified into tubular, tubulovillous, or villous adenomas based on histological subtypes. As for serrated polyps, traditional serrated adenomas (TSAs) and sessile serrated lesions (SSLs) possess carcinogenic potential.

During a colonoscopy, detecting colonic polyps is crucial, but it is equally important to identify which polyps have malignant potential. This allows for the accurate resection of true precancerous lesions while avoiding the procedural risks associated with unnecessary polypectomies. Furthermore, in rare instances, diminutive polyps may harbor cancer with deep submucosal invasion. Due to the risks of incomplete resection and lymph node metastasis, such lesions are not suitable for endoscopic resection. Therefore, achieving an accurate endoscopic diagnosis is a key step in determining the most appropriate management strategy for colonic polyps.

To improve the diagnostic accuracy of endoscopy for colonic polyps, multiple modalities have been developed, including careful observation of lesion morphology, as well as various image-enhanced technologies and chromoendoscopy. Meanwhile, three-dimensional (3D) endoscopy, a novel technology, offers superior spatial resolution and depth perception compared to conventional two-dimensional (2D) endoscopy. Studies have confirmed that 3D endoscopy can improve the adenoma detection rate (ADR) due to its enhanced ability to detect flat and inconspicuous lesions. However, whether 3D colonoscopy can also enhance the endoscopic diagnostic accuracy for colonic polyps remains to be explored. Therefore, we designed a randomized controlled trial (RCT) to investigate whether 3D colonoscopy can improve the diagnostic accuracy of colonic polyps compared to conventional 2D colonoscopy.

This study is a single-country, multicenter randomized controlled trial (RCT), expected to be conducted at National Taiwan University Hospital, National Taiwan University Cancer Center, NTUH Hsinchu Branch, and Chia-Yi Christian Hospital. The trial includes an experimental group (observed first with 3D endoscopy, then with conventional 2D endoscopy) and a control group (observed first with conventional 2D endoscopy, then with 3D endoscopy). As an exploratory study, we plan to enroll 600 adults aged 18 and above undergoing colonoscopy, randomized in a 1:1 ratio into the experimental and control groups. All endoscopists participating in this research project have extensive endoscopic experience, performing at least 100 polypectomies annually. Informed consent will be obtained in the outpatient clinic and the endoscopy center. When a patient requires a colonoscopy, the principal investigator will inquire about their willingness to join the clinical study in the clinic or the endoscopy room. If the subject is willing to participate, a research assistant will help explain the study and assist with the signing of the informed consent form.

When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence. The resected polyps will be sent to the pathology department for histopathological examination. Subsequently, the pathological diagnosis will be compared with both the 3D and 2D endoscopic diagnoses to determine the endoscopic diagnostic accuracy for each, defined as the diagnostic consistency rate between the endoscopic and pathological diagnoses. Regardless of the subject's assigned group, the operator will utilize other image-enhanced techniques (such as NBI or chromoendoscopy) and perform polypectomies according to routine clinical practice during the withdrawal phase.

Endpoints:

Primary Endpoints: The primary endpoint of this study is to compare the diagnosis accuracy rate (DAR) of polyps under different endoscopic modes to determine if there is a significant difference between 3D and 2D colonoscopy. This is primarily calculated by comparing the pathological diagnosis of the resected polyps sent for laboratory testing with the 3D and 2D endoscopic diagnoses, which represents the diagnostic consistency rate. In practical application, each polyp will receive a 3D diagnosis and a 2D diagnosis (regardless of the order), as well as a pathological diagnosis. If the 3D diagnosis of a polyp aligns with the pathological diagnosis, it is considered a correct diagnosis; otherwise, it is deemed incorrect. The DAR is the proportion of correct diagnoses out of the total number of polyps analyzed.

Secondary Endpoints: The secondary endpoints will evaluate the diagnosis alternation rate, which is the frequency of inconsistent endoscopic diagnoses for the same polyp when utilizing different observation methods. Additionally, the impact of factors such as the sizes of polyps, morphology of polyps, and location of polyps on the aforementioned DAR will be assessed. Furthermore, we will compare the incidence of complications and the differences in procedure time between the different endoscopic modes.

Being tested
3D MonoStereo
Keywords
Endoscopy, Colonoscopy, Colo-rectal polyps, 3D Endoscopy

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 3D MonoStereoDevice

    When subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.

Study groups in NCT07619248
Study groupRoleWhat they receive
2D-3D sequenceExperimentalWhen subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.
Receives: Device: 3D MonoStereo
3D-2D sequenceOtherWhen subjects undergo the colonoscopy, the operator will use the conventional 2D endoscopic mode for insertion. Once the colonoscope reaches the cecum, a research assistant will randomly assign the subject to one of the two endoscopic modality sequences using a sealed envelope, with an expected 1:1 allocation ratio between the two groups. The primary difference between the two groups occurs during the withdrawal of the endoscope from the cecum to the anus. If a polyp lesion is detected, one group will first use conventional 2D imaging for polyp diagnosis, and then switch to 3D endoscopy for a second diagnosis. The other group will do the reverse: completing the diagnosis with 3D endoscopy first, and then switching to conventional 2D endoscopy for a second diagnosis. This design aims to eliminate judgment bias caused by the diagnostic sequence.
Receives: Device: 3D MonoStereo

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. diagnosis accuracy rate (DAR) of polyps under different endoscopic modes

    Primary Endpoints: The primary endpoint of this study is to compare the diagnosis accuracy rate (DAR) of polyps under different endoscopic modes to determine if there is a significant difference between 3D and 2D colonoscopy. This is primarily calculated by comparing the pathological diagnosis of the resected polyps sent for laboratory testing with the 3D and 2D endoscopic diagnoses, which represents the diagnostic consistency rate. In practical application, each polyp will receive a 3D diagnosis and a 2D diagnosis (regardless of the order), as well as a pathological diagnosis. If the 3D diagnosis of a polyp aligns with the pathological diagnosis, it is considered a correct diagnosis; otherwise, it is deemed incorrect. The DAR is the proportion of correct diagnoses out of the total number of polyps analyzed.

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Jun 2026
  2. Study start12 May 2026 (estimated)
  3. Primary completion12 May 2027 (estimated)
  4. Study completion12 May 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
600 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07619248
Sponsor's protocol ID
202603028DIPD
Status last verified
May 2026
First submitted
19 May 2026
Last updated
1 Jun 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing 3D MonoStereo in people with Colo-rectal Polyps and Colonoscopy, run by National Taiwan University Hospital.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 1 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Li-Chun Chang, MD, PhD (+886-972-651-285, lichunchang@ntu.edu.tw), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

diagnosis accuracy rate (DAR) of polyps under different endoscopic modes (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in