AzTrials
AzTrials

Glycogen Storage DiseaseNCT07614139

Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders

A study testing Continuous glucose monitor with threshold and predictive alerts (Dexcom G7) and Continuous glucose monitor with threshold-only alerts (Dexcom ONE+) in people with Glycogen Storage Disease and Congenital Hyperinsulinism (CHI), run by University Hospital Padova at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this clinical trial is to learn if a continuous glucose monitor (CGM) with predictive alerts works better than a CGM with standard alerts to prevent low blood sugar (hypoglycemia) in adults with inherited metabolic disorders (IMDs), such as glycogen storage disorders (GSDs) and congenital hyperinsulinism… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Continuous glucose monitor with threshold and predictive alerts (Dexcom G7) and Continuous glucose monitor with threshold-only alerts (Dexcom ONE+)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
11 participants
Where
1 siteItaly
Study dates
8 Jan 2025to 30 Sep 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age 18 years or older
  • Genetic or biochemical diagnosis of Glycogen Storage Disease (GSD) or Congenital Hyperinsulinism (CH)
  • At least one clinical and biochemical follow-up at the hospital outpatient service within the last one or two years
  • Ability to sign informed consent and comply with study procedures

Who cannot join

  • Inability to sign informed consent or comply with study procedures

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • University Hospital of Padova

    Padova, Padova, 35128

Other trials in Italy

About this study

Official title: Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders Prone to Hypoglycemia

The goal of this clinical trial is to learn if a continuous glucose monitor (CGM) with predictive alerts works better than a CGM with standard alerts to prevent low blood sugar (hypoglycemia) in adults with inherited metabolic disorders (IMDs), such as glycogen storage disorders (GSDs) and congenital hyperinsulinism (CH).

The main questions it aims to answer are:

Read more

Does a CGM with predictive alerts lower the time spent with low blood sugar compared to a CGM with standard alerts? Do participants feel better and behave differently when using a CGM with predictive alerts? How accurate are the two CGM devices in this group of people? Researchers will compare two CGM devices - Dexcom G7 (with predictive and standard alerts) and Dexcom ONE+ (with standard alerts only) - to see if predictive alerts help reduce low blood sugar episodes and improve quality of life.

Participants will:

Wear each CGM device for 30 days Have a 30-day break between the two devices Check blood sugar levels and record food intake Complete questionnaires about their experience with each device

Being tested
Continuous glucose monitor with threshold and predictive alerts (Dexcom G7), Continuous glucose monitor with threshold-only alerts (Dexcom ONE+)
Medical subject headings
Glycogen Storage Disease, Congenital Hyperinsulinism, Hypoglycemia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Continuous glucose monitor with threshold and predictive alerts (Dexcom G7)Device

    The Dexcom G7 is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days. It provides real-time interstitial glucose readings every 5 minutes. The device offers both threshold-based alerts, activated when glucose levels fall below or rise above pre-set values, and predictive alerts, activated when glucose levels are predicted to reach a threshold within 20 minutes. The low glucose alert threshold was set at 70 mg/dL for all participants.

  • Continuous glucose monitor with threshold-only alerts (Dexcom ONE+)Device

    The Dexcom ONE+ is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days. It provides real-time interstitial glucose readings every 5 minutes. The device offers threshold-based alerts only, activated when glucose levels fall below or rise above pre-set values, without predictive alert functionality. The low glucose alert threshold was set at 70 mg/dL for all participants.

Study groups in NCT07614139
Study groupRoleWhat they receive
Dexcom G7 (Threshold + Predictive Alerts)Active comparatorNot described
Receives: Device: Continuous glucose monitor with threshold and predictive alerts (Dexcom G7)
Dexcom ONE+ (Threshold-Only Alerts)Active comparatorNot described
Receives: Device: Continuous glucose monitor with threshold-only alerts (Dexcom ONE+)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time Below Range (TBR)

    Percentage of time spent with interstitial glucose levels below 70 mg/dL, as measured by continuous glucose monitoring (CGM). TBR is reported at two thresholds: TBR1 (54-69 mg/dL) and TBR2 (<54 mg/dL), both expressed as percentage of monitoring time (%), over 30 days for each device.

    Unit of Measure: % of monitoring time

    Measured: 30 days per device (total study duration: approximately 90 days including washout period)

Secondary outcomes (10)
  1. Time in Range (TIR)

    Percentage of time spent with interstitial glucose levels within the target range of 70-140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%).

    Unit of Measure: % of monitoring time

    Measured: Time Frame: 30 days per device

  2. Time Above Range (TAR)

    Percentage of time spent with interstitial glucose levels above 140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%).

    Unit of Measure: % of monitoring time

    Measured: Time Frame: 30 days per device

  3. Mean Glucose Level

    Mean interstitial glucose levels calculated over 24 hours and during nighttime (00:00-07:00), as measured by CGM over 30 days for each device.

    Unit of Measure: mg/dL

    Measured: Time Frame: 30 days per device

  4. Sensor Accuracy - median absolute relative difference (MARD)

    Accuracy of CGM readings compared to capillary blood glucose reference values (Accu-Check Instant, Roche), expressed as Median Absolute Relative Difference (MARD). Capillary and CGM values matched within a ±5-minute time window.

    Unit of Measure: %

    Measured: 30 days per device

  5. Dietary Intake Assessment

    Total daily energy intake measured during each device wear period Unit of Measure: kcal/day Total daily macronutrient intake measured during each device wear period Unit of Measure: grams/day Daily uncooked cornstarch intake measured during each device wear period Unit of Measure: grams/day All dietary intakes were assessed by 7-day food diary analyzed with Metadieta® software (Meteda Srl, Italy), completed during CGM monitoring and reviewed by an experienced metabolic dietitian.

    Measured: 7 days per device

  6. Hypoglycemia Fear and Protective Behaviors Assessment

    Assessed using the Hypoglycemia Fear Survey (HFS), comprising two subscales: Worry (HFS-W) and Behavior (HFS-B). Each item scored 0-4; total range 0-132; higher scores indicate greater fear of hypoglycemia and more behaviors engaged to avoid hypoglycemic episodes.

    Unit of Measure: Score (0-132)

    Measured: baseline and after 30 days per device

  7. Hypoglycemia Awareness Assessment

    Assessed using the Clarke Hypoglycemia Awareness Questionnaire (CHAQ), comprising 8 items on hypoglycemia awareness and recognition. Range 0-7; scores ≥4 indicate impaired awareness of hypoglycemia; higher scores indicate worse hypoglycemia awareness.

    Unit of Measure: Score (0-7)

    Measured: baseline and after 30 days per device

  8. Sleep Quality Assessment

    assessed using the Pittsburgh Sleep Quality Index (PSQI), a self-report questionnaire assessing sleep quality and disturbances over the previous month. Global score ranges from 0 to 21; scores >5 indicate poor sleep quality; higher scores indicate worse sleep quality.

    Unit of Measure: Score (0-21)

    Measured: Baseline and after 30 days per device

  9. Health-Related Quality of Life Assessment

    Assessed using the 12-Item Short Form Health Survey (SF-12), yielding Physical Component Summary (PCS) and Mental Component Summary (MCS) standardized scores. Higher scores indicate better quality of life.

    Unit of Measure: Standardized score for Italian population

    Measured: Baseline and after 30 days per device

  10. Body Mass Index (BMI)

    Height measured at baseline; weight measured at the start and end of each CGM period using a calibrated mechanical scale (Seca 700). BMI calculated as weight (kg)/height² (m²), interpreted according to WHO classification: <18.5 underweight; 18.5-25 healthy weight; 25-30 overweight; >30 obesity.

    Unit of Measure: kg/m²

    Measured: Baseline and after 30 days per device

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 May 2026
  2. Study start8 Jan 2025
  3. Primary completion31 Jul 2025
  4. Study completion30 Sep 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
11 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07614139
Sponsor's protocol ID
CET 6104/AO/24, URC AOP3544
Status last verified
May 2026
First submitted
15 May 2026
Last updated
29 May 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Gugelmo G, Maines E, Boscari F, Lenzini L, Fadini GP, Burlina A, Avogaro A, Vitturi N. Continuous glucose monitoring in patients with inherited metabolic disorders at risk for Hypoglycemia and Nutritional implications. Rev Endocr Metab Disord. 2024 Oct;25(5):897-910. doi: 10.1007/s11154-024-09903-y. Epub 2024 Oct 1.

    PubMed 39352577
  • Rossi A, Venema A, Haarsma P, Feldbrugge L, Burghard R, Rodriguez-Buritica D, Parenti G, Oosterveer MH, Derks TGJ. A Prospective Study on Continuous Glucose Monitoring in Glycogen Storage Disease Type Ia: Toward Glycemic Targets. J Clin Endocrinol Metab. 2022 Aug 18;107(9):e3612-e3623. doi: 10.1210/clinem/dgac411.

    PubMed 35786777
  • Overduin RJ, Venema A, Lubout CMA, Fokkert-Wilts MJ, De Boer F, Schreuder AB, Rossi A, Derks TGJ. Continuous glucose monitoring metrics in people with liver glycogen storage disease and idiopathic ketotic hypoglycemia: A single-center, retrospective, observational study. Mol Genet Metab. 2024 Sep-Oct;143(1-2):108573. doi: 10.1016/j.ymgme.2024.108573. Epub 2024 Aug 30.

    PubMed 39243574
  • Peeks F, Hoogeveen IJ, Feldbrugge RL, Burghard R, de Boer F, Fokkert-Wilts MJ, van der Klauw MM, Oosterveer MH, Derks TGJ. A retrospective in-depth analysis of continuous glucose monitoring datasets for patients with hepatic glycogen storage disease: Recommended outcome parameters for glucose management. J Inherit Metab Dis. 2021 Sep;44(5):1136-1150. doi: 10.1002/jimd.12383. Epub 2021 May 5.

    PubMed 33834518
  • Ferreira CR, Rahman S, Keller M, Zschocke J; ICIMD Advisory Group. An international classification of inherited metabolic disorders (ICIMD). J Inherit Metab Dis. 2021 Jan;44(1):164-177. doi: 10.1002/jimd.12348.

    PubMed 33340416

Questions about this trial

What is this clinical trial studying?

A study testing Continuous glucose monitor with threshold and predictive alerts (Dexcom G7) and Continuous glucose monitor with threshold-only alerts (Dexcom ONE+) in people with Glycogen Storage Disease and Congenital Hyperinsulinism (CHI), run by University Hospital Padova at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 May 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time Below Range (TBR) (time frame: 30 days per device (total study duration: approximately 90 days including washout period)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07614139, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 May 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in