Sinus Node DiseaseNCT07608822
BIO|STREAM.CSP CLS
An observational study of Sinus Node Disease and Atrioventricular Block, run by Biotronik SE & Co. KG at 12 sites in 5 countries.
Trial summary
This clinical study is a prospective, observational submodule of the BIO|STREAM.CSP registry designed to evaluate clinical outcomes in patients receiving BIOTRONIK dual-chamber pacemakers that combine conduction system pacing-specifically left bundle branch area pacing (LBBAP)-with Closed Loop Stimulation (CLS). Read more about this study
- Who is it for?
- Ages 18 to 18 years
- Conditions the study is for
- Sinus Node Disease, Atrioventricular Block
- What is being tested?
- Left bundle branch area pacing with Closed Loop Stimulation
- Type of treatment
- Medical device
- How many people
- 150 participants
- Where
- 12 sitesin 5 countries
- Study dates
- 29 May 2026to 29 May 2030
- How long will I take part?
- 24 Months
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 18 years
- All sexes
- No healthy volunteers
- Adult
Study population: Patients with an indication for de novo dual-chamber pacing due to SND with evidence of AV conduction disorders, enrolled in the BIO|STREAM.CSP registry.
Who may be able to join
- Enrolled in the BIO|STREAM.CSP registry
- Standard indication for dual-chamber pacing due to any form of sinus node disease according to guidelines
- DDD-CLS pacing mode activated
- Either ≥ II degree AV block, or native PR interval ≥ 200 ms at baseline ECG with expected RVP ≥ 20%
Who cannot join
- Implantation dates back more than 90 days
- History of clinical AF
- Patients intended to receive, or already received a pacing lead for traditional RV pacing, His bundle pacing or right bundle branch pacing
- Upgrade from previous pacemaker system
- Patients transitioning from the BIO|MASTER.CSP study
- DDAF episodes present in the device memory at the time of registration
Trial locations and contacts
12 sites in 5 countries. Contact the study team or a site near you to ask about taking part.
12 sites in 5 countries
Italy6 sites, 6 recruiting
- Not yet recruiting
Ospedale Di Summa - Perrino
Brindisi
- Not yet recruiting
Niguarda hospital
Milan
- Recruiting
A.O.U. Maggiore della Carita di Novara
Novara
- Not yet recruiting
Ospedale di Piove di Sacco
Piove di Sacco
- Not yet recruiting
Fondazione Policlinico Universitario "Agostino Gemelli" Università Cattolica del Sacro Cuore
Roma
- Not yet recruiting
SS Annunziata Taranto
Taranto
Hungary2 sites, 2 recruiting
- Not yet recruiting
Semmelweis University
Budapest
- Not yet recruiting
University of Szeged
Szeged
Spain2 sites, 2 recruiting
- Not yet recruiting
Hospital Universitario 12 de Octubre
Madrid
- Not yet recruiting
Hospital Universitario La Fe
Valencia
Czechia1 site, 1 recruiting
- Not yet recruiting
Masarykova nemocnice v Usti nad Labem
Ústí nad Labem
Portugal1 site, 1 recruiting
- Not yet recruiting
Unidade local de Saúde de Coimbra, EPE - Centro Hospitalar Universitario de Coimbra
Coimbra
About this study
Official title: Observation of Clinical Routine Care for Patients Implanted With BIOTRONIK Devices Used for Conduction System Pacing (CSP) With Focus on Closed Loop Stimulation (CLS)
This clinical study is a prospective, observational submodule of the BIO|STREAM.CSP registry designed to evaluate clinical outcomes in patients receiving BIOTRONIK dual-chamber pacemakers that combine conduction system pacing-specifically left bundle branch area pacing (LBBAP)-with Closed Loop Stimulation (CLS). The purpose of the study is to better understand how this combined pacing strategy performs in routine clinical practice and whether it may help reduce the occurrence of atrial fibrillation in patients with sinus node dysfunction (SND) and concomitant atrioventricular (AV) conduction disorders.
The primary question the study seeks to answer is what the incidence of device-detected atrial fibrillation (DDAF) is over a 24-month follow-up period in patients treated with LBBAP and active CLS. Additionally, the study explores how CLS dynamically modulates pacing rates when the ventricular lead is positioned within the conduction system, and whether this physiological pacing approach may mitigate the negative effects associated with conventional right ventricular pacing.
Overall, this study aims to generate real-world evidence to support optimization of pacemaker programming and to inform clinical decision-making regarding the use of CLS in combination with conduction system pacing, with the goal of improving patient outcomes and reducing atrial arrhythmia burden.
Read the detailed description
This study, BIO|STREAM.CSP CLS, is a prospective, observational submodule of the ongoing BIO|STREAM.CSP registry. It is designed to collect real-world clinical data from patients who receive BIOTRONIK dual-chamber pacemakers using conduction system pacing (CSP), with a specific focus on the combination of left bundle branch area pacing (LBBAP) and Closed Loop Stimulation (CLS).
Permanent cardiac pacing is a standard therapy for patients with sinus node dysfunction (SND), a condition in which the heart's natural pacemaker does not function properly. A considerable proportion of these patients also have atrioventricular (AV) conduction disorders, which impair the electrical connection between the atria and ventricles. In such cases, dual-chamber pacemakers are typically implanted to maintain appropriate heart rhythm and coordination.
Traditional right ventricular (RV) pacing, while effective in maintaining heart rate, has been associated with non-physiological activation of the heart and may contribute to an increased risk of atrial fibrillation (AF), especially when pacing burden is high. Device-detected atrial fibrillation (DDAF) is a clinically relevant outcome, as it is associated with increased risk of stroke, heart failure, and other cardiovascular complications.
Closed Loop Stimulation (CLS) is an advanced pacemaker feature designed to provide more physiological heart rate adaptation by continuously monitoring cardiac contractility and adjusting the pacing rate accordingly. In previous studies, including the B3 trial, CLS demonstrated a reduction in DDAF incidence in patients with SND. However, this benefit was not observed in patients with AV block, likely due to the adverse effects of frequent RV pacing.
Conduction system pacing, and in particular left bundle branch area pacing (LBBAP), is an emerging pacing strategy that stimulates the heart's intrinsic conduction pathways, resulting in a more physiological and synchronized ventricular activation. This approach has the potential to reduce the negative effects associated with RV pacing.
The BIO|STREAM.CSP CLS submodule aims to investigate whether the combination of LBBAP and CLS can reduce the incidence of DDAF in patients with both SND and AV conduction disorders in routine clinical practice. The study will follow approximately 150 patients over a 24-month period after pacemaker implantation. Patients included are those enrolled in the BIO|STREAM.CSP registry who receive a de novo dual-chamber pacemaker with activated CLS and LBBAP, and who have no prior history of atrial fibrillation.
The primary objective of this exploratory submodule is to assess the incidence and timing of DDAF episodes following activation of CLS, using device-based diagnostics over the follow-up period. The study will evaluate multiple thresholds of AF episode duration (e.g., ≥6 minutes, ≥6 hours, ≥24 hours, and ≥7 days), as well as the time to first occurrence and overall AF burden. Secondary analyses will explore how CLS modulates heart rate in patients with conduction system pacing, including the distribution of paced and sensed heart rates over time.
As an observational study without a control group, BIO|STREAM.CSP CLS is intended to generate hypothesis-generating, real-world evidence rather than to test a predefined hypothesis. The findings are expected to provide insights into the clinical performance of CLS in combination with LBBAP and to support optimization of device programming strategies.
Overall, this study seeks to improve understanding of how advanced pacing technologies can be used together to deliver more physiological cardiac pacing, with the goal of reducing atrial arrhythmias and improving long-term outcomes in patients requiring permanent pacemakers.
- Conditions
- Sinus Node Disease, Atrioventricular Block
- Being tested
- Left bundle branch area pacing with Closed Loop Stimulation
- Keywords
- Conduction system pacing, Closed loop stimulation, Dual-chamber pacemaker, Left bundle branch area pacing
- Medical subject headings
- Sick Sinus Syndrome, Atrioventricular Block
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Left bundle branch area pacing with Closed Loop StimulationDevice
Permanent dual-chamber cardiac pacing with ventricular lead placement in the left bundle branch area and activation of the Closed Loop Stimulation (CLS) rate-responsive algorithm.
What is being measured
The primary outcome is the main question the study is designed to answer.
DDAF incidence
Time from CLS activation to the first device-detected atrial fibrillation (DDAF) episode of different duration cutoffs (6 minutes, 6 hours, 24 hours, 7 days) through 24 months of follow-up after implantation
Measured: From CLS activation to 24 months after implantation
DDAF burden
The time from CLS activation to the first day with a DDAF burden ≥1% (≈15 minutes) determined within a follow-up period of 24 months after implantation
Measured: From CLS activation to 24 months after implantation
Heart Rate histograms
Heart Rate histograms of sensed and paced beats [% time] at 1-year and 2-year follow-ups
Measured: At 1 year and 2 years after implantation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 May 2026
- Study start29 May 2026
- Primary completion29 May 2028 (estimated)
- Study completion29 May 2030 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Sinus Node DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 150 participants (estimated)
- Target duration
- 24 Months
Sponsor and investigators
- Lead sponsor
- Biotronik SE & Co. KG
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07608822
- Sponsor's protocol ID
- BA121
- Status last verified
- May 2026
- First submitted
- 20 May 2026
- Last updated
- 17 Jul 2026
- Results posted
- No
Study at a glance
From the registry record, last updated by the sponsor on 17 Jul 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Observation of Clinical Routine Care for Patients Implanted With BIOTRONIK Devices Used for Conduction System Pacing (CSP) With Focus on Closed Loop Stimulation (CLS)
- ClinicalTrials.gov ID
- NCT07608822
- Acronym / sponsor ID
- BA121
- Conditions
- Sinus Node Disease, Atrioventricular Block
- Keywords
- Conduction system pacing, Closed loop stimulation, Dual-chamber pacemaker, Left bundle branch area pacing
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 150 participants (estimated)
- Lead sponsor
- Biotronik SE & Co. KGIndustry (pharma, biotech, devices)
- Study start
- 29 May 2026 (actual)
- Primary completion
- 29 May 2028 (estimated)
- Study completion
- 29 May 2030 (estimated)
- First posted
- 27 May 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This clinical study is a prospective, observational submodule of the BIO|STREAM.CSP registry designed to evaluate clinical outcomes in patients receiving BIOTRONIK dual-chamber pacemakers that combine conduction system pacing-specifically left bundle branch area pacing (LBBAP)-with Closed Loop Stimulation (CLS). The purpose of the study is to better understand how this combined pacing strategy performs in routine clinical practice and whether it may help reduce the occurrence of atrial fibrillation in patients with sinus node dysfunction (SND) and concomitant atrioventricular (AV) conduction disorders.
The primary question the study seeks to answer is what the incidence of device-detected atrial fibrillation (DDAF) is over a 24-month follow-up period in patients treated with LBBAP and active CLS. Additionally, the study explores how CLS dynamically modulates pacing rates when the ventricular lead is positioned within the conduction system, and whether this physiological pacing approach may mitigate the negative effects associated with conventional right ventricular pacing.
Overall, this study aims to generate real-world evidence to support optimization of pacemaker programming and to inform clinical decision-making regarding the use of CLS in combination with conduction system pacing, with the goal of improving patient outcomes and reducing atrial arrhythmia burden.
Detailed description
This study, BIO|STREAM.CSP CLS, is a prospective, observational submodule of the ongoing BIO|STREAM.CSP registry. It is designed to collect real-world clinical data from patients who receive BIOTRONIK dual-chamber pacemakers using conduction system pacing (CSP), with a specific focus on the combination of left bundle branch area pacing (LBBAP) and Closed Loop Stimulation (CLS).
Permanent cardiac pacing is a standard therapy for patients with sinus node dysfunction (SND), a condition in which the heart's natural pacemaker does not function properly. A considerable proportion of these patients also have atrioventricular (AV) conduction disorders, which impair the electrical connection between the atria and ventricles. In such cases, dual-chamber pacemakers are typically implanted to maintain appropriate heart rhythm and coordination.
Traditional right ventricular (RV) pacing, while effective in maintaining heart rate, has been associated with non-physiological activation of the heart and may contribute to an increased risk of atrial fibrillation (AF), especially when pacing burden is high. Device-detected atrial fibrillation (DDAF) is a clinically relevant outcome, as it is associated with increased risk of stroke, heart failure, and other cardiovascular complications.
Closed Loop Stimulation (CLS) is an advanced pacemaker feature designed to provide more physiological heart rate adaptation by continuously monitoring cardiac contractility and adjusting the pacing rate accordingly. In previous studies, including the B3 trial, CLS demonstrated a reduction in DDAF incidence in patients with SND. However, this benefit was not observed in patients with AV block, likely due to the adverse effects of frequent RV pacing.
Conduction system pacing, and in particular left bundle branch area pacing (LBBAP), is an emerging pacing strategy that stimulates the heart's intrinsic conduction pathways, resulting in a more physiological and synchronized ventricular activation. This approach has the potential to reduce the negative effects associated with RV pacing.
The BIO|STREAM.CSP CLS submodule aims to investigate whether the combination of LBBAP and CLS can reduce the incidence of DDAF in patients with both SND and AV conduction disorders in routine clinical practice. The study will follow approximately 150 patients over a 24-month period after pacemaker implantation. Patients included are those enrolled in the BIO|STREAM.CSP registry who receive a de novo dual-chamber pacemaker with activated CLS and LBBAP, and who have no prior history of atrial fibrillation.
The primary objective of this exploratory submodule is to assess the incidence and timing of DDAF episodes following activation of CLS, using device-based diagnostics over the follow-up period. The study will evaluate multiple thresholds of AF episode duration (e.g., ≥6 minutes, ≥6 hours, ≥24 hours, and ≥7 days), as well as the time to first occurrence and overall AF burden. Secondary analyses will explore how CLS modulates heart rate in patients with conduction system pacing, including the distribution of paced and sensed heart rates over time.
As an observational study without a control group, BIO|STREAM.CSP CLS is intended to generate hypothesis-generating, real-world evidence rather than to test a predefined hypothesis. The findings are expected to provide insights into the clinical performance of CLS in combination with LBBAP and to support optimization of device programming strategies.
Overall, this study seeks to improve understanding of how advanced pacing technologies can be used together to deliver more physiological cardiac pacing, with the goal of reducing atrial arrhythmias and improving long-term outcomes in patients requiring permanent pacemakers.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Target follow-up
- 24 Months
Who may qualify
- Ages
- 18 to 18 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult
- Study population
- Patients with an indication for de novo dual-chamber pacing due to SND with evidence of AV conduction disorders, enrolled in the BIO|STREAM.CSP registry.
Key inclusion criteria (4 listed)
- Enrolled in the BIO|STREAM.CSP registry
- Standard indication for dual-chamber pacing due to any form of sinus node disease according to guidelines
- DDD-CLS pacing mode activated
- Either ≥ II degree AV block, or native PR interval ≥ 200 ms at baseline ECG with expected RVP ≥ 20%
Key exclusion criteria (6 listed)
- Implantation dates back more than 90 days
- History of clinical AF
- Patients intended to receive, or already received a pacing lead for traditional RV pacing, His bundle pacing or right bundle branch pacing
- Upgrade from previous pacemaker system
- Patients transitioning from the BIO|MASTER.CSP study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Left bundle branch area pacing with Closed Loop StimulationPermanent dual-chamber cardiac pacing with ventricular lead placement in the left bundle branch area and activation of the Closed Loop Stimulation (CLS) rate-responsive algorithm. | Device | – |
Primary outcome
DDAF incidence
Time frame: From CLS activation to 24 months after implantation
Time from CLS activation to the first device-detected atrial fibrillation (DDAF) episode of different duration cutoffs (6 minutes, 6 hours, 24 hours, 7 days) through 24 months of follow-up after implantation
DDAF burden
Time frame: From CLS activation to 24 months after implantation
The time from CLS activation to the first day with a DDAF burden ≥1% (≈15 minutes) determined within a follow-up period of 24 months after implantation
Heart Rate histograms
Time frame: At 1 year and 2 years after implantation
Heart Rate histograms of sensed and paced beats [% time] at 1-year and 2-year follow-ups
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Jul 2026.
Related trials for Sinus Node Disease
RecruitingObservational study
BIO|STREAM.CSP Study
Cardiac Pacing, Cardiac Pacemaker
Active, not recruiting
BIO|MASTER.CSP Study
Cardiac Pacing, Artificial, Cardiac Pacemaker, Artificial
Not yet recruiting
Belgo-Luxembourg Leadless PM Registry
Bradyarrhythmias, AV Block Complete
Active, not recruitingObservational study
AVEIR DR Coverage With Evidence Development (CED) Study
Cardiac Pacemaker, Arrythmia
Recruiting
LEAP 2 Chronic EFS
Cardiac Pacemaker, Cardiac Rhythm Disorder
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
12 sites in 5 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Sinus Node Disease and Atrioventricular Block, run by Biotronik SE & Co. KG at 12 sites in 5 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 17 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 12 sites in Italy, Hungary, Spain, Czechia, Portugal. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Martina Del Maestro (+393426529214, CLS-CSP-STREAM@biotronik.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
DDAF incidence (time frame: From CLS activation to 24 months after implantation). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jul 2026.