Prosthetic Socket Fit Testing System

A study testing Prosthetic socket fit testing system in people with Amputation, run by University of Washington at 1 site in United States.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

Ensuring a well fitting prosthetic socket is a major challenge in the care of people with amputation. Poor fit causes pain, skin issues, reduced mobility, and lower satisfaction, affecting daily activity and quality of life. Read more about this study

Who is it for?
Ages 18 to 70 years
Conditions the study is for
Amputation
What is being tested?
Prosthetic socket fit testing system
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
1 siteUnited States
Study dates
12 Oct 2026to 28 Feb 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 70 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • be between 18 and 70 years old
  • have a unilateral transfemoral amputation
  • be at least 12 months post-amputation
  • have a residual limb that is free of open wounds or infections
  • wear a prosthesis for a minimum of four hours per day
  • be able to ambulate short distances with a prosthesis
Show all 12Show fewer
  • be able to stand on the intact leg for brief periods
  • be able to hold onto parallel bars with the arms for balance
  • have pain-free range of motion at the hip on the amputated side
  • have no back problems that make standing or hip movement difficult
  • have corrected vision that is sufficient to see the cursors on the screen
  • be able to follow simple instructions in English

Who cannot join

  • residual limb issues (e.g. sensitive or frail skin) that may be made worse by testing
  • a prosthetic socket that cannot be disconnected from the distal prosthetic components
  • unable to read and speak English

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Stefania Fatone, PhD, BPO(Hons) contact

206-685-7918

sfaton@uw.edu

United States1 site, 1 recruiting
  • University of Washington

    Seattle, Washington, 98195

    Stefania Fatone, PhD, 206-685-7918, sfaton@uw.edu

    Recruiting

Other trials in United States

About this study

Official title: Evaluation of a Prototype Socket Fit Testing System to Assess Coupling of the Prosthetic Socket in Individuals With Lower Limb Amputation

Ensuring a well fitting prosthetic socket is a major challenge in the care of people with amputation. Poor fit causes pain, skin issues, reduced mobility, and lower satisfaction, affecting daily activity and quality of life. Current prosthetic socket fit assessment relies on prosthesis user feedback, prosthetist experience or intrusive equipment. The investigators have developed a non-invasive prototype socket fit testing system that attaches externally to the end of any prosthetic socket and uses two air cylinders to apply resistance and track motion. During testing, socket motion is mapped to a cursor on a screen. Participants perform a test where they move their leg and socket to randomly presented targets. Movement duration and accuracy provide measures of how well the socket and leg move together. This pilot study will assess feasibility and validity of the socket fit testing system performance for above-the-knee prosthesis users.

Read the detailed description

One of the biggest challenges in prosthetic care is making sure the prosthetic socket fits well with the residual limb. This "socket fit" is critical for both comfort and function. When the socket doesn't fit properly, it can cause pain, skin problems, and reduced performance. Poor socket fit can also lower a person's satisfaction with their prosthesis, limit their ability to perform daily activities, and negatively impact quality of life.

Current methods of assessing socket fit are qualitative-based on patient feedback or comfort surveys-or they use expensive and/or invasive equipment. These methods don't provide precise measurements of how well the socket and residual limb are working together, and some require altering the socket to insert instrumentation inside.

To address these limitations, the investigators are testing a non-invasive prototype device for measuring socket fit. This device attaches externally to the end of any prosthetic socket and uses two long air cylinders connected to sensors (potentiometers and load cells) and a TV monitor. With it, prosthesis users can perform different leg movements against resistance while wearing their socket.

The standardized test protocol requires participants to perform hip movements in all directions (flexion, extension, abduction, and adduction). The movement range is scaled to each person's height and hip motion, so the test has a consistent level of difficulty across individuals. The main hypothesis is that a better socket fit will allow more accurate movements, measured by how long the movements take and how much error is present. The overarching hypothesis is that better socket fit will result in more accurate movements, as measured by movement duration and error.

In this study, the investigators will evaluate the prototype device in adults with unilateral above-the-knee (transfemoral amputation, TFA). The investigators plan to recruit 18 participants with TFA:

  • Eight participants with TFA will complete 2 testing visits to examine whether practice influences results and to confirm that the protocol is feasible.
  • Ten participants with TFA will be purposively sampled to ensure that their current socket includes features that can make the fit easy to adjust. Participants will complete 2 testing visits so the investigators can determine whether the system can measure differences in socket-limb coupling, using metrics such as movement duration and error.

The investigators will also compare these movement metrics with participants' self-reported Socket Comfort Scores. Showing that the test protocol is feasible to implement, the device operates as intended, and differences in coupling can be detected will give the investigators pilot data to support larger clinical trials.

Specific Aims

  1. Test the feasibility, repeatability and practice effects of the prototype socket fit testing protocol in people with transfemoral amputation.
  2. Show that the system can detect differences in socket fit in people with transfemoral amputation, using movement metrics such as duration and error.
  3. Validate the movement metrics by comparing them to patient-reported Socket Comfort Scores.
Conditions
Amputation
Being tested
Prosthetic socket fit testing system
Keywords
prosthesis, assessment, socket fit

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Prosthetic socket fit testing systemDevice

    Prosthetic socket fit testing system to assess socket-limb coupling using movement error and duration.

Study groups in NCT07491614
Study groupRoleWhat they receive
Individuals with transfemoral amputationOtherProsthetic socket fit testing system
Receives: Device: Prosthetic socket fit testing system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Repeatability

    Assess repeatability of performing the prosthetic socket fit test in terms of movement time and accuracy.

    Measured: 1 week

Secondary outcomes (3)
  1. Practice effects

    Assess how many trials are required for steady state performing the prosthetic socket fit test in terms of movement time and accuracy.

    Measured: Day 1

  2. Known groups validity

    Assess difference in measurement time and accuracy between loose and tight prosthetic socket fit

    Measured: Day 1

  3. Convergent validity

    Assess correlation between movement time and accuracy with socket comfort score for difference between tight and loose fitting prosthetic sockets.

    Measured: Day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Mar 2026
  2. Study start12 Oct 2026
  3. Primary completion28 Feb 2027 (estimated)
  4. Study completion28 Feb 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
18 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07491614
Sponsor's protocol ID
STUDY00023726
Other IDs
UL1TR002319
Status last verified
Oct 2026
First submitted
15 Mar 2026
Last updated
23 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in