Intratracheal InbubationNCT07453563
Airway Scope vs GlideScope for Intubation in Obese Patients
A study testing Intubation with GlideScope and Intubation with Airway Scope in people with Intratracheal Inbubation, run by University of New Mexico at 1 site in United States.
Trial summary
This study compares the time required to complete intubation in obese patients (Body Mass Index 40 or greater) when using either the GlideScope or Airway Scope video laryngoscope device to help place the endotracheal tube. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Intratracheal Inbubation
- What is being tested?
- Intubation with GlideScope and Intubation with Airway Scope
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 70 participants
- Where
- 1 siteUnited States
- Study dates
- 13 Jul 2026to Mar 2027
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adult (age ≥18 years)
- Body Mass Index (BMI) ≥40
- Scheduled for surgery with general anesthesia
Who cannot join
- Pregnancy
- Congenital facial or airway anomalies
- History of major neck surgery or tracheostomy
- History of any lung diseases/conditions such as Chronic Obstructive Pulmonary Disease, lung resection, or lung cancer
- History of cardiac failure or myocardial infarction
- Prisoners
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
United States1 site, 1 recruiting
- Recruiting
University of New Mexico Health Sciences Center
Albuquerque, New Mexico, 87131
Yuta Kashiwagi, MD, 505-272-2610, YKashiwagi@salud.unm.edu
About this study
Official title: Comparison of GlideScope and Airway Scope for Intubating Morbidly Obese Patients: A Randomized Controlled Study
This study compares the time required to complete intubation in obese patients (Body Mass Index 40 or greater) when using either the GlideScope or Airway Scope video laryngoscope device to help place the endotracheal tube.
Read the detailed description
This is a randomized controlled trial of two video laryngoscope devices when used in patients with high (≥40) Body Mass Index (BMI): Airway Scope (Nihon Kohden) and GlideScope (Verathon Inc.). The study compares several outcomes as proxies for ease of intubation including time to complete intubation, number of attempts needed, minimum peripheral oxygen saturation (SpO2) during intubation, and number of episodes of SpO2 falling below 90% before intubation is completed. The patient population is consenting adult patients with BMI ≥40, who are already scheduled for general anesthesia. Intubations will be performed by attending anesthesiologists or anesthesiology residents. Obesity is a known risk factor for difficult intubation due to anatomical changes caused by increased soft tissue around the face and neck. Obese patients' blood oxygen level can rapidly fall during intubation because these patients often have reduced functional residual capacity, and the acuity of any complications may also be increased because these patients also often have additional comorbidities.
- Conditions
- Intratracheal Inbubation
- Being tested
- Intubation with GlideScope, Intubation with Airway Scope
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Intubation with GlideScopeDevice
Intubation performed by anesthesiologist using the GlideScope video laryngoscope device
Intubation with Airway ScopeDevice
Intubation performed by anesthesiologist using the Airway Scope video laryngoscope device
| Study group | Role | What they receive |
|---|---|---|
| GlideScope Arm | Active comparator | Intubation with GlideScope Receives: Device: Intubation with GlideScope |
| Airway Scope Arm | Experimental | Intubation with Airway Scope Receives: Device: Intubation with Airway Scope |
What is being measured
The primary outcome is the main question the study is designed to answer.
Intubation completion time
Time interval between the start of the intubation procedure and its completion, defined by confirmed end-tidal carbon dioxide (CO2) observation.
Measured: Perioperative/Periprocedural
Secondary outcomes (3)
Humber of hypoxia episodes
The number of episodes of hypoxia during the intubation procedure, defined as peripheral oxygen saturation (SpO2) <90%.
Measured: Perioperative/Periprocedural
Number of intubation attempts
The count of attempts required to complete the intubation procedure, with completion defined as confirmed end-tidal CO2
Measured: Perioperative/Periprocedural
Minimum SpO2 observed during intubation
The minimum value of SpO2 observed during the intubation procedure
Measured: Perioperative/Periprocedural
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Mar 2026
- Study start13 Jul 2026
- Primary completionMar 2027 (estimated)
- Study completionMar 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Intratracheal InbubationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 70 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University of New Mexico
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Yuta Kashiwagi, University of New Mexico
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07453563
- Sponsor's protocol ID
- AWS vs GlideScope
- Status last verified
- Aug 2026
- First submitted
- 24 Feb 2026
- Last updated
- 14 Aug 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 14 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison of GlideScope and Airway Scope for Intubating Morbidly Obese Patients: A Randomized Controlled Study
- ClinicalTrials.gov ID
- NCT07453563
- Acronym / sponsor ID
- AWS vs GlideScope
- Conditions
- Intratracheal Inbubation
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 70 participants (estimated)
- Lead sponsor
- University of New MexicoUniversity, hospital or other
- Study start
- 13 Jul 2026 (actual)
- Primary completion
- Mar 2027 (estimated)
- Study completion
- Mar 2027 (estimated)
- First posted
- 6 Mar 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study compares the time required to complete intubation in obese patients (Body Mass Index 40 or greater) when using either the GlideScope or Airway Scope video laryngoscope device to help place the endotracheal tube.
Detailed description
This is a randomized controlled trial of two video laryngoscope devices when used in patients with high (≥40) Body Mass Index (BMI): Airway Scope (Nihon Kohden) and GlideScope (Verathon Inc.). The study compares several outcomes as proxies for ease of intubation including time to complete intubation, number of attempts needed, minimum peripheral oxygen saturation (SpO2) during intubation, and number of episodes of SpO2 falling below 90% before intubation is completed. The patient population is consenting adult patients with BMI ≥40, who are already scheduled for general anesthesia. Intubations will be performed by attending anesthesiologists or anesthesiology residents. Obesity is a known risk factor for difficult intubation due to anatomical changes caused by increased soft tissue around the face and neck. Obese patients' blood oxygen level can rapidly fall during intubation because these patients often have reduced functional residual capacity, and the acuity of any complications may also be increased because these patients also often have additional comorbidities.
Study design
- Primary purpose
- Supportive care
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| GlideScope Arm | Active comparator | Device: Intubation with GlideScopeIntubation with GlideScope |
| Airway Scope Arm | Experimental | Device: Intubation with Airway ScopeIntubation with Airway Scope |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Adult (age ≥18 years)
- Body Mass Index (BMI) ≥40
- Scheduled for surgery with general anesthesia
Key exclusion criteria (6 listed)
- Pregnancy
- Congenital facial or airway anomalies
- History of major neck surgery or tracheostomy
- History of any lung diseases/conditions such as Chronic Obstructive Pulmonary Disease, lung resection, or lung cancer
- History of cardiac failure or myocardial infarction
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Intubation with GlideScopeIntubation performed by anesthesiologist using the GlideScope video laryngoscope device | Device | GlideScope Arm |
| Intubation with Airway ScopeIntubation performed by anesthesiologist using the Airway Scope video laryngoscope device | Device | Airway Scope Arm |
Primary outcome
Intubation completion time
Time frame: Perioperative/Periprocedural
Time interval between the start of the intubation procedure and its completion, defined by confirmed end-tidal carbon dioxide (CO2) observation.
3 secondary outcomes
Humber of hypoxia episodes
Time frame: Perioperative/Periprocedural
Number of intubation attempts
Time frame: Perioperative/Periprocedural
Minimum SpO2 observed during intubation
Time frame: Perioperative/Periprocedural
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Aug 2026.
- Individual participant dataSharing planned: No
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Intubation with GlideScope and Intubation with Airway Scope in people with Intratracheal Inbubation, run by University of New Mexico at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 14 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Yuta Kashiwagi, MD (505-272-2610, YKashiwagi@salud.unm.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Intubation completion time (time frame: Perioperative/Periprocedural). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?