AzTrials
AzTrials

Cardiac Resynchronization TherapyFORGE CSPNCT07406737

Feasibility and Outcomes Registry of Lumenless dEfibrillation Leads for Conduction System Pacing

An observational study of Cardiac Resynchronization Therapy and Left Bundle Branch Area Pacing, run by University Hospital, Caen at 1 site in France.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The recent development and market introduction of small diameter implantable defibrillation leads able to deliver left bundle branch area pacing (LBBAP) has opened the possibility of achieving cardiac resynchronization therapy (CRT) using a single- or dual-chamber implantable-cardioverter defibrillator (ICD). Read more about this study

Who is it for?
Ages 18 years and older
How many people
200 participants
Where
1 siteFrance
Study dates
1 May 2026to 1 Sep 2027
How long will I take part?
12 Months
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Consecutive patients with a validated CRT indication for whom the implantation of a LBBAP ICD lead in attempted as a first-line strategy.

Who may be able to join

  • age > 18-year-old
  • indication for CRT according to current ESC/EHRA guidelines
  • first-line LBBAP ICD lead implantation attempted
  • national insurance coverage

Who cannot join

  • pregnancy

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Pierre OLLITRAULT, MD contact

+330231063106

ollitrault-p@chu-caen.fr

France1 site
  • Caen University Hospital

    Caen

Other trials in France

About this study

The recent development and market introduction of small diameter implantable defibrillation leads able to deliver left bundle branch area pacing (LBBAP) has opened the possibility of achieving cardiac resynchronization therapy (CRT) using a single- or dual-chamber implantable-cardioverter defibrillator (ICD). This approach may reduce the number of intracardiac leads required and, consequently, has the potential to lower both procedural and long-term complication rates. However, the integration of these leads into currently recommended CRT strategies remains hypothetical. The FORGE CSP registry will prospectively enroll patients with an indication for CRT in whom implantation of a LBBAP ICD lead is attempted.

Read the detailed description

The FORGE CSP Registry is a prospective, multicentre and nationwide, post-approval registry, including consecutive patients with an indication for CRT and in whom implantation of a LBBAP ICD lead is attempted as a first line strategy.

The primary objective of this registry is to measure the proportion of patients who achieve effective CRT solely through the use of a LBBAP ICD lead (plus right atrial lead if appropriate).

The secondary objectives of this registry are: (1) to assess the feasibility of the LBBAP ICD lead implantation (regarding LBBAP validated electrophysiologic criteria) and the associated learning curve; (2) to evaluate the incidence of implantation of a third lead, namely a left ventricular lead positioned in the coronary sinus, in combination with the LBBAP ICD lead (LOT-CRT); (3) to assess the risk of complications related to the use of the LBBAP ICD lead, including its impact on tricuspid valve function, the risk of lead dislodgement, and other procedure- or device-related complications; (4) to evaluate de cost-effectiveness of CRT using LBBAP ICD lead, compared with conventional CRT; (5) and to compare CRT response in LBBAP ICD lead recipients, versus historical cohort of conventional CRT.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. LBBAP ICD lead CRT efficacy

    Proportion of patients with an effective CRT (defined by LBBAP validated ECG criteria) using solely the LBBAP ICD lead (plus right atrial lead if appropriate).

    Measured: 0 - 3 Months

Secondary outcomes (4)
  1. LBBAP ICD lead implantation feasibility

    Incidence of successful LBBAP ICD lead implantation (defined by LBBAP ECG validated criteria)

    Measured: Procedural

  2. LOT-CRT utilization

    Incidence of coronary sinus left ventricular lead implantation (in addition to LBBAP ICD lead)

    Measured: Procedural

  3. Safety of LBBAP ICD lead

    Incidence of ICD lead micro or macro-dislodgment Incidence of de novo tricuspid regurgitation (grade > or = 3) Incidence of loss of CRT (based on LBBAP validated ECG criteria)

    Measured: 0 - 3 Months

  4. Cost-effectiveness

    Comparaison of device-associated costs in LBBAP ICD lead recipients and conventional CRT recipients.

    Measured: Procedural

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Feb 2026
  2. Study start1 May 2026 (estimated)
  3. Primary completion1 May 2027 (estimated)
  4. Study completion1 Sep 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
200 participants (estimated)
Target duration
12 Months
IDs, dates and publications
ClinicalTrials.gov ID
NCT07406737
Sponsor's protocol ID
2026-RYTHMO-01
Acronym
FORGE CSP
Status last verified
Feb 2026
First submitted
6 Feb 2026
Last updated
12 Feb 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Vijayaraman P, Liu X, Denman R, Schloss EJ, Whinnett ZI, Kron J, Jastrzebski M, Zakaib JS, Abhayaratna WP, Philippon F, Afzal MR, Pokharel P, Burrell J, Tanner J, Geelen T, Platner ML, Butler K, Mason PK, Crossley GH; LEADR LBBAP Trial Investigators. Safety and performance of a novel defibrillation lead for left bundle branch area placement: Primary results of the LEADR LBBAP clinical trial. Heart Rhythm. 2025 Oct 17:S1547-5271(25)02981-9. doi: 10.1016/j.hrthm.2025.10.028. Online ahead of print.

    PubMed 41110529
  • Crossley GH 3rd, Sanders P, Hansky B, De Filippo P, Shah MJ, Shoda M, Khelae SK, Richardson TD, Philippon F, Zakaib JS, Tse HF, Sholevar DP, Stellbrink C, Pathak RK, Milasinovic G, Chinitz JS, Tsang B, West MB, Ramza BM, Han X, Bozorgnia B, Carta R, Geelen T, Himes AK, Platner ML, Thompson AE, Mason PK; Lead EvaluAtion for Defibrillation and Reliability Trial Investigators. Safety, efficacy, and reliability evaluation ofa novel small-diameter defibrillation lead: Global LEADR pivotal trial results. Heart Rhythm. 2024 Oct;21(10):1914-1922. doi: 10.1016/j.hrthm.2024.04.067. Epub 2024 May 17.

    PubMed 38762820
  • Sanders P, Mason PK, Hansky B, De Filippo P, Shah MJ, Sholevar DP, Zakaib JS, Philippon F, Tsang B, Pathak RK, Richardson TD, Friedman M, Schaller RD, Anguera I, Mihalcz A, Bozorgnia B, Thompson AE, Arias K, Maus B, Bounds C, Crossley GH. Sensing and detection performance of the novel, small-diameter OmniaSecure defibrillation lead: in-depth analysis from the LEADR trial. Europace. 2025 Mar 28;27(4):euaf062. doi: 10.1093/europace/euaf062.

    PubMed 40127675
  • Crossley GH 3rd, Mason PK, Hansky B, De Filippo P, Shah MJ, Philippon F, Sholevar D, Richardson TD, West MB, Dinerman J, Dawson J, Himes A, Severseike L, Thompson AE, Sanders P. High predicted durability for the novel small-diameter OmniaSecure defibrillation lead. Heart Rhythm. 2025 Feb;22(2):302-310. doi: 10.1016/j.hrthm.2024.09.005. Epub 2024 Sep 26.

    PubMed 39341436
  • Crossley GH, Sanders P, Hansky B, De Filippo P, Shah MJ, Khelae SK, Richardson TD, Philippon F, Zakaib JS, Geelen T, Arias K, Maus B, Mason PK; Lead EvaluAtion for Defibrillation and Reliability Trial Investigators. Safety and Efficacy of the Novel OmniaSecure Defibrillation Lead Through Long-Term Follow-Up: Final Results From the LEADR Trial. Circ Arrhythm Electrophysiol. 2026 Jan;19(1):e014424. doi: 10.1161/CIRCEP.125.014424. Epub 2025 Nov 12.

    PubMed 41222500

Questions about this trial

What is this clinical trial studying?

An observational study of Cardiac Resynchronization Therapy and Left Bundle Branch Area Pacing, run by University Hospital, Caen at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 12 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Pierre OLLITRAULT, MD (+330231063106, ollitrault-p@chu-caen.fr), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

LBBAP ICD lead CRT efficacy (time frame: 0 - 3 Months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07406737, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Feb 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in