Colorectal LesionsNCT07405203
Assessment of the EndoR System in ESD for Colorectal Lesions
A study testing EndoR Surgical System in people with Colorectal Lesions, run by Chinese University of Hong Kong at 1 site in Hong Kong.
Trial summary
Gastrointestinal (GI) cancers are common and significant causes of cancer death worldwide. GI cancers grow from the mucosal layer. If pre-malignant and early cancers are removed en bloc at an early stage before they spread to lymph nodes, survival rates can be improved. Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Colorectal Lesions
- What is being tested?
- EndoR Surgical System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 6 participants
- Where
- 1 siteHong Kong
- Study dates
- 1 Jan 2026to 30 Jun 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Aged between 18 and 85.
- Patient with superficial colorectal lesions, scheduled for endoscopic submucosal dissection (ESD). According to the European Society of Gastrointestinal Endoscopy (ESGE) and the Japan Gastroenterological
- Endoscopy Society (JGES) guidelines for colorectal ESD:
- Lesions for which en bloc resection with snare EMR would be difficult to apply; ii. Mucosal tumors with submucosal fibrosis; iii. Sporadic tumors in conditions of chronic inflammation; iv. Local residual or recurrent early carcinomas after endoscopic resection.
Who cannot join
- No informed consent available.
- Carcinoma of colon or rectum with invasion to submucosa or beyond.
- Evidence of distant metastasis.
- Another active malignancy present.
- Pregnant.
- Patients are unfit for general anesthesia.
- The target lesion that could not be reached by the endoscopic platform.
- Have been recruited in another clinical trial.
Trial locations and contacts
1 site in 1 country.
Hong Kong1 site
Department of Surgery, Faculty of Medicine, the Chinese University of Hong Kong
Hong Kong
About this study
Official title: A Single-Arm Pilot Study to Assess Safety and Performance of the EndoR Surgical System to Perform Endoscopic Submucosal Dissection (ESD) for the Treatment of Colorectal Lesions
Gastrointestinal (GI) cancers are common and significant causes of cancer death worldwide. GI cancers grow from the mucosal layer. If pre-malignant and early cancers are removed en bloc at an early stage before they spread to lymph nodes, survival rates can be improved.
Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) were developed as minimally invasive, organ-sparing methods for removing pre-malignant and early GI cancers. While EMR is suitable for smaller lesions, ESD is typically required for larger lesions. ESD offers the advantage of a higher rate of complete, single-piece resection, which is associated with a lower risk of local recurrence compared to EMR. However, ESD is a technically complex procedure with a higher risk of complications, such as perforation and bleeding.
Read more
Conventional ESD is performed using a flexible endoscope with a single instrument channel to access the GI tract. This setup presents several challenges, including difficulty in maintaining the endoscope in a stable position, limited ability to provide effective tissue traction, and frequent intraprocedural bleeding. As a result, ESD demands a high level of technical skills from surgeons.
The EndoR Surgical System was developed to address these challenges, aiming to allow surgeons to operate two surgical instruments with enhanced dexterity and a broader range of motions. Both pre-clinical ex-vivo studies and in-vivo studies were conducted in the development of this surgical system.
Six pre-clinical ex-vivo studies were conducted in porcine stomach between 2015 and 2023 and eleven pre-clinical in-vivo studies were conducted in live porcine models with the lesion sites at stomach, rectum and left colon between 2016 and 2024. These pre-clinical studies were conducted in LASEC-PWH, MISSC-PWH and Hybrid Operating Room of Multi-Scale Medical Robotics Center (MRC) accordingly.
Based on data from the ex-vivo and in-vivo experiments, two key conclusions can be drawn:
- After several training sessions, the operator's performance became more consistent and efficient. ii) The dissection rate increased as the dissection area grew-a phenomenon not observed in conventional procedures using a single endoscope and dissection tool.
From the results demonstrated from the pre-clinical studies, the EndoR Surgical System allows for greater dexterity and precision in manipulating instruments, which is particularly advantageous for larger lesions. This precision can lead to more effective dissection and reduced damage to surrounding tissues. This may also reduce the risk of complications associated with ESD. By minimizing trauma to adjacent structures, the likelihood of adverse events, such as bleeding or perforation, may be significantly lowered. Patients may experience faster recovery times, contributing to improved patients' satisfaction and outcomes. As the risk of complications decreases, endoscopic procedures like ESD could become accessible to a broader patient population.
While performing ESD is generally considered safe, it still remains a technically demanding procedure with the assistance of the surgical robotic system. The use of surgical robots introduces the risk of equipment malfunctions, which can lead to complications during the procedure. Additionally, any technical issues may result in delays, potentially compromising patient safety.
The attending physicians will monitor and examine the subjects as necessary and appropriate and work carefully to ensure their safety. In the event of an adverse reaction, countermeasures will be taken as appropriate, and focus will be placed on ensuring the safety of the subjects while the cause of the reaction is investigated.
The objective of this study is to assess the safety and performance of the EndoR Surgical System for the treatment of patients with colorectal malignant lesions. Technical success, clinical success and any adverse events shall be recorded.
Read the detailed description
Background Information
- Purpose of the System 1.1. Device Name The EndoR Surgical System is a master-slave robotic platform designed for endoscopic surgery, featuring flexible dual arms and a cognitive control system. 1.2. Intended Indications and Usage The EndoR Surgical System is an advanced endoscopic surgical robotic system designed to assist surgeons and endoscopists to perform endoscopic surgeries. This is a system intended to provide both visualization and therapeutic access to the adult gastrointestinal (GI) tract for endoscopic surgeries, aiming to improve visualization and potentially reduce procedure time and technical complexity. Comprehensive guidelines for the preparation and operation of the EndoR Surgical System are provided in the Instructions for Use (IFU). The IFU will be distributed to all investigators and reviewed during training prior to initiating any procedures. 1.3. Product Description The EndoR Surgical System consists of two parts: the patient side and the surgeon side as shown in Figure 1. On the patient side, four main components can be found: a processing unit, a robotic carrier, a driving unit, and an overtube system with instruments. On the surgeon side, three main components can be found: a master console, a surgical monitor, and an ergonomic surgeon chair. On the surgeon side, the master console is the surgeon's primary interface with the EndoR Surgical System. It features intuitive controls that allow the surgeon to manipulate the robotic instruments with high precision remotely. The console transmits real-time commands to the patient-side processing unit. The surgical monitor displays high-definition, real-time video feeds from the endoscopic camera and other imaging sources. It provides the surgeon with a clear and detailed view of the operative field, enabling accurate navigation and decision-making throughout the procedure. The ergonomic surgeon chair is designed to maximize operator comfort and minimize fatigue during lengthy procedures. It features adjustable support for posture and armrests for stability while operating the console. A foot pedal of the electrocautery machine is usually placed near the surgeon's chair to control the electrocautery action of the dissector manipulator. On the patient side, the processing unit serves as the central "brain" of the system. It receives commands from the surgeon's console, interprets input signals, and coordinates the actions of all robotic components. This unit integrates real-time data processing, safety algorithms, and system diagnostics to ensure precise and synchronized movements during surgery. The robotic carrier is a stable platform designed to securely position and support the endoscopic instruments at the patient's bedside. It provides the structural framework for mounting the driving unit and endoscopic overtube system and can be adjusted for optimal alignment with the patient's anatomy. The carrier provides three standard motions to enable fine adjustment of the orientation of the instrument: translation along the overtube axial axis, rotational motion along the overtube axial axis, and up-down and left-right motion. The driving unit contains the actuators and motors that physically control the motion of the instruments. It translates digital commands from the processing unit into mechanical actions, such as rotation, insertion, or articulation of the endoscopic tools. The flexible endoscopic overtube system is designed to guide and protect the endoscope and instruments as they are advanced into the patient's gastrointestinal tract. Integrated within the overtube are instruments capable of performing complex surgical tasks such as tissue dissection and retraction. The endoscopic overtube system enhances stability and precision during endoscopic procedures. The connection between the overtube and the driving unit incorporates two attachment mechanisms. The first is a rotary attachment mechanism, which allows the overtube to be connected axially, enabling the orientation to be selected prior to installing the instruments. This design addresses surgical scenarios where the treatment area is extensive and, with conventional endoscopes, would typically require repositioning the patient during the procedure. Instead, the rotary mechanism permits the overtube to rotate and lock securely at four distinct angles, optimizing the surgical posture of the manipulator without the need to move the patient. This feature streamlines the workflow and shortens overall procedure time by eliminating unnecessary setup steps. The second is a sliding attachment mechanism, which allows the overtube to be connected from the side of the driving unit. This mechanism is not used in normal operating procedures but is used only in emergency situations, for example when the overtube needs to be removed instantly from the patient. The active bending section of the endoscopic overtube is controlled by knots. Two bending directions are provided (pitch and yaw direction), and the bending angles of each direction can be locked by pulling the knot in the direction out of the driving unit. The endoscopic channel enables the use of an endoscopic camera within the system, offering a clear view of the surgical location. The decoupled motion between the camera and the instruments further enhances the field of view and visual stability.
- Findings From Pre-clinical Studies 2.1. Background of the Disease and Endoscopic Procedures Gastrointestinal cancers are common and significant causes of cancer death worldwide. GI cancers grow from the mucosal layer. If pre-malignant and early cancers are removed en bloc at an early stage before they spread to lymph nodes, survival rates can be improved. Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) were developed as minimally invasive, organ-sparing methods for removing pre-malignant and early gastrointestinal cancers. While EMR is suitable for smaller lesions, ESD is typically required for larger lesions. ESD offers the advantage of a higher rate of complete, single-piece resection, which is associated with a lower risk of local recurrence compared to EMR. However, ESD is a technically complex procedure with a higher risk of complications such as perforation and bleeding. Conventional ESD is performed using a flexible endoscope with a single instrument channel to access the gastrointestinal tract. This setup presents several challenges, including difficulty in maintaining the endoscope in a stable position, limited ability to provide effective tissue traction, and frequent intraprocedural bleeding. As a result, ESD demands a high level of technical skill from surgeons. 2.2. Summary of Pre-clinical Studies The EndoR Surgical System was developed to address these challenges, aiming to allow surgeons to operate two surgical instruments with enhanced dexterity and a broader range of motions. Both pre-clinical ex-vivo studies and in-vivo studies were conducted in the development of this surgical system. Six pre-clinical ex-vivo studies were conducted in porcine stomach between 2015 and 2023, and eleven pre-clinical in-vivo studies were conducted in live porcine models with the lesion sites at the stomach, rectum, and left colon between 2016 and 2024. These pre-clinical studies were conducted in LASEC-PWH, MISSC-PWH, and the Hybrid Operating Room of the Multi-Scale Medical Robotics Center (MRC).
- Pre-clinical (Ex-vivo) Study Six pre-clinical ex-vivo studies were conducted between 2015 and 2023, spanning from the initial development of the robotic arms to the fully functional robotic platform. All studies utilized porcine stomach specimens in a bench-top setup. II. Pre-clinical (In-vivo) Study Eleven pre-clinical in-vivo studies were conducted between 2016 and 2024. All studies were performed in live porcine models weighing between 30 and 55 kg. The surgical sites included the stomach, rectum, and left colon. All studies were conducted under the supervision of clinical experts and were administered in a registered pre-clinical laboratory. The porcine models were given analgesics for pain relief before procedures and were euthanized before the end of the study if they suffered any serious injury or showed signs of severe pain or distress. Oxygen saturation and heart rate were monitored throughout the studies, and the porcine models were sacrificed by overdose of anesthetic. Based on data from the ex-vivo and in-vivo experiments, two key conclusions can be drawn:
- After several training sessions, operator performance became more consistent and efficient. ii) The dissection rate increased as the dissection area grew, a phenomenon not observed in conventional procedures using a single endoscope and dissection tool.
- Potential Risks and Benefits From the results demonstrated in the pre-clinical studies, the EndoR Surgical System allows for greater dexterity and precision in manipulating instruments, which is particularly advantageous for larger lesions. This precision can lead to more effective dissection and reduced damage to surrounding tissues. This may also reduce the risk of complications associated with ESD. By minimizing trauma to adjacent structures, the likelihood of adverse events such as bleeding or perforation may be significantly lowered. Patients may experience faster recovery times, contributing to improved satisfaction and outcomes. As the risk of complications decreases, endoscopic procedures like ESD could become accessible to a broader patient population. While performing ESD is generally considered safe, it remains a technically demanding procedure even with the assistance of the surgical robotic system. The use of surgical robots introduces the risk of equipment malfunctions, which can lead to complications during the procedure. Additionally, any technical issues may result in delays, potentially compromising patient safety. The attending physicians will monitor and examine subjects as necessary and will work carefully to ensure subject safety. In the event of an adverse reaction, countermeasures will be taken as appropriate, and focus will be placed on ensuring subject safety while the cause of the reaction is investigated.
- Duration of the Study and Follow-up Period The total duration of this study is two years. The enrollment period is expected to be completed within approximately one year, involving six subjects. Upon discharge, follow-up visits of subjects for this study will take place at the fourth to sixth week, sixth to eighth month, and twelfth to fourteenth month as clinically indicated. All subjects enrolled in this study will also receive clinical follow-up and surveillance according to standard clinical protocols thereafter.
- Compliance This study will be conducted in compliance with the following guidelines and regulations:
- International Council for Harmonization (ICH) Guideline on Good Clinical Practice (ICH E6)
- Declaration of Helsinki
- ISO 14155:2011 - Clinical Investigation of Medical Devices for Human Subjects (Good Clinical Practice)
- All applicable local legal and regulatory requirements, as appropriate
- Study Population This study will recruit six adult patients with superficial colorectal lesions scheduled for endoscopic submucosal dissection (ESD).
Trial Objective and Purpose
- Objective The objective of this study is to assess the safety and performance of the EndoR Surgical System for the treatment of patients with colorectal malignant lesions. Technical success, clinical success, and any adverse events will be recorded.
- Purpose The purpose of this study is to evaluate the EndoR Surgical System in human subjects. The EndoR Surgical System is designed for endoscopic procedures in the gastrointestinal (GI) tract through the natural orifices of the human body, with the goal of establishing a reliable, minimally invasive system that enhances patient outcomes.
- Hypothesis The EndoR Surgical System is safe and efficacious for use in colonic endoscopic submucosal dissection.
- Conditions
- Colorectal Lesions
- Being tested
- EndoR Surgical System
- Keywords
- EndoR, ESD, Endoscopic Submucosal Dissection
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
EndoR Surgical SystemDevice
The EndoR Surgical System is a master-slave robotic platform designed for endoscopic surgery, featuring flexible dual arms and cognitive control system.
| Study group | Role | What they receive |
|---|---|---|
| EndoR System assisted ESD | Experimental | Recruited subjects will undergo robotic ESD under general anesthesia using EndoR Surgical System. Receives: Device: EndoR Surgical System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Rate of complete (R0) resection
Defined as en bloc, one-piece resection with histologically confirmed tumor-free lateral and vertical margins.
Unit of measure: % of procedures
Measured: 1 day
Secondary outcomes (32)
[Safety] Rate of intraoperative bleeding
Bleeding at resection site prolonging procedure but not requiring transfusion or surgical intervention.
Unit of measure: % of procedures
Measured: 1 day
[Safety] Rate of adjunctive procedures
Rate of adjunctive procedures, during study procedure required to control bleeding (e.g. clips or haemostatic agents).
Unit of measure: % of procedures
Measured: 1 day
[Safety] All-cause mortality
Death from any cause within 12 months following the index procedure. Unit of measure: % of patients
Measured: 12 months
[Safety] Rate of infection
Clinical sepsis with changes in inflammatory markers, as adjudicated by investigators.
Unit of measure: % of patients
Measured: 30 days
[Safety] Rate of Serious Adverse Events (SAEs)
Proportion of subjects experiencing any SAE during the index procedure, at discharge, or within 12 months.
Unit of measure: % of patients
Measured: 12 months
[Safety] Rate of SAEs - death
Death occurring within 12 months of index procedure. Unit of measure: % of patients
Measured: 12 months
[Safety] Rate of SAEs - serious deterioration in the health
Rate of serious deterioration in the health of the subject, users, or other persons as defined by one or more of the following:
- a life-threatening illness or injury, or ii. a permanent impairment of a body structure or a body function including chronic diseases, or iii. in-patient or prolonged hospitalization, or iv. medical or surgical intervention to prevent life-threatening illness or injury, or permanent impairment to a body structure or a body function.
Unit of measure: % of patients
Measured: 12 months
[Safety] Rate of SAEs - fetal complications
Proportion of subjects experiencing fetal distress, fetal death, congenital abnormality, or birth defect (including physical or mental impairment) following the index procedure.
Unit of measure: % of cases involving pregnancy
Measured: 12 months
[Performance] Technical success rate
En bloc, one-piece excision of the neoplasm irrespective of histopathology, without device-related SAE through 30 days.
Unit of measure: % of procedures
Measured: 30 days
[Performance] Duration of instrument calibration
Total time for calibration of the device (e.g., dissector/retractor). Unit of measure: minutes
Measured: 1 day
[Performance] Duration of resection
Time taken to complete neoplasm excision. Unit of measure: minutes
Measured: 1 day
[Performance] Total ESD procedure time
Time from start of submucosal injection to end of procedure. Unit of measure: minutes
Measured: 1 day
[Performance] Dissection rate
Rate at which the target tissue is dissected during ESD. Dissection rate = Resected lesion area / Dissection time Unit of measure: mm²/minute
Measured: 1 day
[Performance] Histological analysis of resected specimen
Pathological evaluation of resected specimen for completeness, margin status, and depth of invasion.
Unit of measure: categorical
Measured: 30 days
[Performance] Proportion of time the submucosa was visualized
Proportion of time submucosa visualized during procedure (SM ratio) Unit of measure: % of total procedure time
Measured: 1 day
[Performance] Number of additional submucosal injections required
Count of reinforcement injections used during procedure. Unit of measure: number per procedure
Measured: 1 day
[Performance] Length of hospital stay
Number of days from procedure to discharge. Unit of measure: days
Measured: up to discharge
[Performance] Rate of device deficiencies
Proportion of procedures affected by any device malfunction or use error. Unit of measure: % of procedures
Measured: 1 day
[Performance] NASA Task Load Index
NASA Task Load Index (NASA-TLX) score reflecting perceived workload during the procedure (range 0-100; higher = greater workload).
Unit of measure: score (0-100)
Measured: 1 day
[Performance] Overall rate of intraprocedural adverse events
Rate of all intra-procedural adverse event. Unit of measure: % of procedures
Measured: 1 day
[Performance] Rate of intraprocedural adverse events - partial thickness muscle damage
Partial-thickness muscle injury during procedure. Unit of measure: % of procedures
Measured: 1 day
[Performance] Rate of intraprocedural adverse events - full thickness perforation
Full-thickness perforation during procedure. Unit of measure: % of procedures
Measured: 1 day
[Performance] Rate of intraprocedural adverse events - hemorrhage
Major bleeding during the procedure requiring transfusion or causing >2 g/dL hemoglobin drop.
Unit of measure: % of procedures
Measured: 1 day
[Performance] Rate of intraprocedural adverse events - peritonitis
Inflammation of the peritoneum occurring intra-procedure. Unit of measure: % of procedures
Measured: 1 day
[Performance] Rate of other intra-procedural adverse events
Any other intra-procedure adverse events not categorized above. Unit of measure: % of procedures
Measured: 1 day
[Performance] Overall rate of postprocedural adverse events
Rate of all adverse events occurring after procedure. Unit of measure: % of patients
Measured: 30 days
[Performance] Rate of postprocedural adverse events - electrocoagulation syndrome
Abdominal pain with fever or leukocytosis following procedure. Unit of measure: % of patients
Measured: 30 days
[Performance] Rate of postprocedural adverse events - postoperative delayed bleeding
Bleeding after discharge requiring transfusion, intervention, or hemodynamic support.
Unit of measure: % of patients
Measured: 30 days
[Performance] Rate of postprocedural adverse events - post-procedure delayed perforation
Perforation occurring after completion of the index procedure. Unit of measure: % of patients
Measured: 30 days
[Performance] Rate of other post-procedural adverse events
Any other adverse events related to the endoscopic procedure. Unit of measure: % of patients
Measured: 30 days
[Performance] Colonoscopy findings at 6-8 months
Colonoscopic analysis at the 6-8th month postoperative to assess:
- Healing of operative site
- Presence of suspicious tissue for biopsy (with results of biopsy)
- Presence of a stricture Unit of measure: categorical (healed / abnormal / stricture)
Measured: 6-8 months post-procedure
[Performance] Colonoscopy findings at 12-14 months
Colonoscopic analysis at the 12-14th month postoperative to assess:
- Healing of operative site
- Presence of suspicious tissue for biopsy (with results of biopsy)
- Presence of a stricture Unit of measure: categorical (healed / abnormal / stricture)
Measured: 12-14 months post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted12 Feb 2026
- Study start1 Jan 2026
- Primary completion31 Dec 2027 (estimated)
- Study completion30 Jun 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (5)Papers the sponsor has linked to this study.
- Other trials for Colorectal LesionsStudies of the same condition, open and under way.
- More trials run by Chinese University of Hong KongThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 6 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Chinese University of Hong Kong
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Hon Chi Yip, Chinese University of Hong Kong
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07405203
- Sponsor's protocol ID
- CRE-2025.546
- Status last verified
- Feb 2026
- First submitted
- 4 Feb 2026
- Last updated
- 12 Feb 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Akahoshi K, Akahane H, Murata A, Akiba H, Oya M. Endoscopic submucosal dissection using a novel grasping type scissors forceps. Endoscopy. 2007 Dec;39(12):1103-5. doi: 10.1055/s-2007-966842.
PubMed 18072064Teoh AY, Chiu PW, Wong SK, Sung JJ, Lau JY, Ng EK. Difficulties and outcomes in starting endoscopic submucosal dissection. Surg Endosc. 2010 May;24(5):1049-54. doi: 10.1007/s00464-009-0724-8. Epub 2009 Nov 13.
PubMed 19911227Oka S, Tanaka S, Kaneko I, Mouri R, Hirata M, Kawamura T, Yoshihara M, Chayama K. Advantage of endoscopic submucosal dissection compared with EMR for early gastric cancer. Gastrointest Endosc. 2006 Dec;64(6):877-83. doi: 10.1016/j.gie.2006.03.932. Epub 2006 Sep 20.
PubMed 17140890ASGE TECHNOLOGY COMMITTEE; Kantsevoy SV, Adler DG, Conway JD, Diehl DL, Farraye FA, Kwon R, Mamula P, Rodriguez S, Shah RJ, Wong Kee Song LM, Tierney WM. Endoscopic mucosal resection and endoscopic submucosal dissection. Gastrointest Endosc. 2008 Jul;68(1):11-8. doi: 10.1016/j.gie.2008.01.037. No abstract available.
PubMed 18577472Ferlay J, Soerjomataram I, Dikshit R, Eser S, Mathers C, Rebelo M, Parkin DM, Forman D, Bray F. Cancer incidence and mortality worldwide: sources, methods and major patterns in GLOBOCAN 2012. Int J Cancer. 2015 Mar 1;136(5):E359-86. doi: 10.1002/ijc.29210. Epub 2014 Oct 9.
PubMed 25220842
Study at a glance
From the registry record, last updated by the sponsor on 12 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Single-Arm Pilot Study to Assess Safety and Performance of the EndoR Surgical System to Perform Endoscopic Submucosal Dissection (ESD) for the Treatment of Colorectal Lesions
- ClinicalTrials.gov ID
- NCT07405203
- Acronym / sponsor ID
- CRE-2025.546
- Conditions
- Colorectal Lesions
- Keywords
- EndoR, ESD, Endoscopic Submucosal Dissection
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 6 participants (estimated)
- Lead sponsor
- Chinese University of Hong KongUniversity, hospital or other
- Study start
- 1 Jan 2026 (actual)
- Primary completion
- 31 Dec 2027 (estimated)
- Study completion
- 30 Jun 2028 (estimated)
- First posted
- 12 Feb 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Gastrointestinal (GI) cancers are common and significant causes of cancer death worldwide. GI cancers grow from the mucosal layer. If pre-malignant and early cancers are removed en bloc at an early stage before they spread to lymph nodes, survival rates can be improved.
Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) were developed as minimally invasive, organ-sparing methods for removing pre-malignant and early GI cancers. While EMR is suitable for smaller lesions, ESD is typically required for larger lesions. ESD offers the advantage of a higher rate of complete, single-piece resection, which is associated with a lower risk of local recurrence compared to EMR. However, ESD is a technically complex procedure with a higher risk of complications, such as perforation and bleeding.
Conventional ESD is performed using a flexible endoscope with a single instrument channel to access the GI tract. This setup presents several challenges, including difficulty in maintaining the endoscope in a stable position, limited ability to provide effective tissue traction, and frequent intraprocedural bleeding. As a result, ESD demands a high level of technical skills from surgeons.
The EndoR Surgical System was developed to address these challenges, aiming to allow surgeons to operate two surgical instruments with enhanced dexterity and a broader range of motions. Both pre-clinical ex-vivo studies and in-vivo studies were conducted in the development of this surgical system.
Six pre-clinical ex-vivo studies were conducted in porcine stomach between 2015 and 2023 and eleven pre-clinical in-vivo studies were conducted in live porcine models with the lesion sites at stomach, rectum and left colon between 2016 and 2024. These pre-clinical studies were conducted in LASEC-PWH, MISSC-PWH and Hybrid Operating Room of Multi-Scale Medical Robotics Center (MRC) accordingly.
Based on data from the ex-vivo and in-vivo experiments, two key conclusions can be drawn:
- After several training sessions, the operator's performance became more consistent and efficient. ii) The dissection rate increased as the dissection area grew-a phenomenon not observed in conventional procedures using a single endoscope and dissection tool.
From the results demonstrated from the pre-clinical studies, the EndoR Surgical System allows for greater dexterity and precision in manipulating instruments, which is particularly advantageous for larger lesions. This precision can lead to more effective dissection and reduced damage to surrounding tissues. This may also reduce the risk of complications associated with ESD. By minimizing trauma to adjacent structures, the likelihood of adverse events, such as bleeding or perforation, may be significantly lowered. Patients may experience faster recovery times, contributing to improved patients' satisfaction and outcomes. As the risk of complications decreases, endoscopic procedures like ESD could become accessible to a broader patient population.
While performing ESD is generally considered safe, it still remains a technically demanding procedure with the assistance of the surgical robotic system. The use of surgical robots introduces the risk of equipment malfunctions, which can lead to complications during the procedure. Additionally, any technical issues may result in delays, potentially compromising patient safety.
The attending physicians will monitor and examine the subjects as necessary and appropriate and work carefully to ensure their safety. In the event of an adverse reaction, countermeasures will be taken as appropriate, and focus will be placed on ensuring the safety of the subjects while the cause of the reaction is investigated.
The objective of this study is to assess the safety and performance of the EndoR Surgical System for the treatment of patients with colorectal malignant lesions. Technical success, clinical success and any adverse events shall be recorded.
Detailed description
Background Information
- Purpose of the System 1.1. Device Name The EndoR Surgical System is a master-slave robotic platform designed for endoscopic surgery, featuring flexible dual arms and a cognitive control system. 1.2. Intended Indications and Usage The EndoR Surgical System is an advanced endoscopic surgical robotic system designed to assist surgeons and endoscopists to perform endoscopic surgeries. This is a system intended to provide both visualization and therapeutic access to the adult gastrointestinal (GI) tract for endoscopic surgeries, aiming to improve visualization and potentially reduce procedure time and technical complexity. Comprehensive guidelines for the preparation and operation of the EndoR Surgical System are provided in the Instructions for Use (IFU). The IFU will be distributed to all investigators and reviewed during training prior to initiating any procedures. 1.3. Product Description The EndoR Surgical System consists of two parts: the patient side and the surgeon side as shown in Figure 1. On the patient side, four main components can be found: a processing unit, a robotic carrier, a driving unit, and an overtube system with instruments. On the surgeon side, three main components can be found: a master console, a surgical monitor, and an ergonomic surgeon chair. On the surgeon side, the master console is the surgeon's primary interface with the EndoR Surgical System. It features intuitive controls that allow the surgeon to manipulate the robotic instruments with high precision remotely. The console transmits real-time commands to the patient-side processing unit. The surgical monitor displays high-definition, real-time video feeds from the endoscopic camera and other imaging sources. It provides the surgeon with a clear and detailed view of the operative field, enabling accurate navigation and decision-making throughout the procedure. The ergonomic surgeon chair is designed to maximize operator comfort and minimize fatigue during lengthy procedures. It features adjustable support for posture and armrests for stability while operating the console. A foot pedal of the electrocautery machine is usually placed near the surgeon's chair to control the electrocautery action of the dissector manipulator. On the patient side, the processing unit serves as the central "brain" of the system. It receives commands from the surgeon's console, interprets input signals, and coordinates the actions of all robotic components. This unit integrates real-time data processing, safety algorithms, and system diagnostics to ensure precise and synchronized movements during surgery. The robotic carrier is a stable platform designed to securely position and support the endoscopic instruments at the patient's bedside. It provides the structural framework for mounting the driving unit and endoscopic overtube system and can be adjusted for optimal alignment with the patient's anatomy. The carrier provides three standard motions to enable fine adjustment of the orientation of the instrument: translation along the overtube axial axis, rotational motion along the overtube axial axis, and up-down and left-right motion. The driving unit contains the actuators and motors that physically control the motion of the instruments. It translates digital commands from the processing unit into mechanical actions, such as rotation, insertion, or articulation of the endoscopic tools. The flexible endoscopic overtube system is designed to guide and protect the endoscope and instruments as they are advanced into the patient's gastrointestinal tract. Integrated within the overtube are instruments capable of performing complex surgical tasks such as tissue dissection and retraction. The endoscopic overtube system enhances stability and precision during endoscopic procedures. The connection between the overtube and the driving unit incorporates two attachment mechanisms. The first is a rotary attachment mechanism, which allows the overtube to be connected axially, enabling the orientation to be selected prior to installing the instruments. This design addresses surgical scenarios where the treatment area is extensive and, with conventional endoscopes, would typically require repositioning the patient during the procedure. Instead, the rotary mechanism permits the overtube to rotate and lock securely at four distinct angles, optimizing the surgical posture of the manipulator without the need to move the patient. This feature streamlines the workflow and shortens overall procedure time by eliminating unnecessary setup steps. The second is a sliding attachment mechanism, which allows the overtube to be connected from the side of the driving unit. This mechanism is not used in normal operating procedures but is used only in emergency situations, for example when the overtube needs to be removed instantly from the patient. The active bending section of the endoscopic overtube is controlled by knots. Two bending directions are provided (pitch and yaw direction), and the bending angles of each direction can be locked by pulling the knot in the direction out of the driving unit. The endoscopic channel enables the use of an endoscopic camera within the system, offering a clear view of the surgical location. The decoupled motion between the camera and the instruments further enhances the field of view and visual stability.
- Findings From Pre-clinical Studies 2.1. Background of the Disease and Endoscopic Procedures Gastrointestinal cancers are common and significant causes of cancer death worldwide. GI cancers grow from the mucosal layer. If pre-malignant and early cancers are removed en bloc at an early stage before they spread to lymph nodes, survival rates can be improved. Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) were developed as minimally invasive, organ-sparing methods for removing pre-malignant and early gastrointestinal cancers. While EMR is suitable for smaller lesions, ESD is typically required for larger lesions. ESD offers the advantage of a higher rate of complete, single-piece resection, which is associated with a lower risk of local recurrence compared to EMR. However, ESD is a technically complex procedure with a higher risk of complications such as perforation and bleeding. Conventional ESD is performed using a flexible endoscope with a single instrument channel to access the gastrointestinal tract. This setup presents several challenges, including difficulty in maintaining the endoscope in a stable position, limited ability to provide effective tissue traction, and frequent intraprocedural bleeding. As a result, ESD demands a high level of technical skill from surgeons. 2.2. Summary of Pre-clinical Studies The EndoR Surgical System was developed to address these challenges, aiming to allow surgeons to operate two surgical instruments with enhanced dexterity and a broader range of motions. Both pre-clinical ex-vivo studies and in-vivo studies were conducted in the development of this surgical system. Six pre-clinical ex-vivo studies were conducted in porcine stomach between 2015 and 2023, and eleven pre-clinical in-vivo studies were conducted in live porcine models with the lesion sites at the stomach, rectum, and left colon between 2016 and 2024. These pre-clinical studies were conducted in LASEC-PWH, MISSC-PWH, and the Hybrid Operating Room of the Multi-Scale Medical Robotics Center (MRC).
- Pre-clinical (Ex-vivo) Study Six pre-clinical ex-vivo studies were conducted between 2015 and 2023, spanning from the initial development of the robotic arms to the fully functional robotic platform. All studies utilized porcine stomach specimens in a bench-top setup. II. Pre-clinical (In-vivo) Study Eleven pre-clinical in-vivo studies were conducted between 2016 and 2024. All studies were performed in live porcine models weighing between 30 and 55 kg. The surgical sites included the stomach, rectum, and left colon. All studies were conducted under the supervision of clinical experts and were administered in a registered pre-clinical laboratory. The porcine models were given analgesics for pain relief before procedures and were euthanized before the end of the study if they suffered any serious injury or showed signs of severe pain or distress. Oxygen saturation and heart rate were monitored throughout the studies, and the porcine models were sacrificed by overdose of anesthetic. Based on data from the ex-vivo and in-vivo experiments, two key conclusions can be drawn:
- After several training sessions, operator performance became more consistent and efficient. ii) The dissection rate increased as the dissection area grew, a phenomenon not observed in conventional procedures using a single endoscope and dissection tool.
- Potential Risks and Benefits From the results demonstrated in the pre-clinical studies, the EndoR Surgical System allows for greater dexterity and precision in manipulating instruments, which is particularly advantageous for larger lesions. This precision can lead to more effective dissection and reduced damage to surrounding tissues. This may also reduce the risk of complications associated with ESD. By minimizing trauma to adjacent structures, the likelihood of adverse events such as bleeding or perforation may be significantly lowered. Patients may experience faster recovery times, contributing to improved satisfaction and outcomes. As the risk of complications decreases, endoscopic procedures like ESD could become accessible to a broader patient population. While performing ESD is generally considered safe, it remains a technically demanding procedure even with the assistance of the surgical robotic system. The use of surgical robots introduces the risk of equipment malfunctions, which can lead to complications during the procedure. Additionally, any technical issues may result in delays, potentially compromising patient safety. The attending physicians will monitor and examine subjects as necessary and will work carefully to ensure subject safety. In the event of an adverse reaction, countermeasures will be taken as appropriate, and focus will be placed on ensuring subject safety while the cause of the reaction is investigated.
- Duration of the Study and Follow-up Period The total duration of this study is two years. The enrollment period is expected to be completed within approximately one year, involving six subjects. Upon discharge, follow-up visits of subjects for this study will take place at the fourth to sixth week, sixth to eighth month, and twelfth to fourteenth month as clinically indicated. All subjects enrolled in this study will also receive clinical follow-up and surveillance according to standard clinical protocols thereafter.
- Compliance This study will be conducted in compliance with the following guidelines and regulations:
- International Council for Harmonization (ICH) Guideline on Good Clinical Practice (ICH E6)
- Declaration of Helsinki
- ISO 14155:2011 - Clinical Investigation of Medical Devices for Human Subjects (Good Clinical Practice)
- All applicable local legal and regulatory requirements, as appropriate
- Study Population This study will recruit six adult patients with superficial colorectal lesions scheduled for endoscopic submucosal dissection (ESD).
Trial Objective and Purpose
- Objective The objective of this study is to assess the safety and performance of the EndoR Surgical System for the treatment of patients with colorectal malignant lesions. Technical success, clinical success, and any adverse events will be recorded.
- Purpose The purpose of this study is to evaluate the EndoR Surgical System in human subjects. The EndoR Surgical System is designed for endoscopic procedures in the gastrointestinal (GI) tract through the natural orifices of the human body, with the goal of establishing a reliable, minimally invasive system that enhances patient outcomes.
- Hypothesis The EndoR Surgical System is safe and efficacious for use in colonic endoscopic submucosal dissection.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| EndoR System assisted ESD | Experimental | Device: EndoR Surgical SystemRecruited subjects will undergo robotic ESD under general anesthesia using EndoR Surgical System. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Aged between 18 and 85.
- Patient with superficial colorectal lesions, scheduled for endoscopic submucosal dissection (ESD). According to the European Society of Gastrointestinal Endoscopy (ESGE) and the Japan Gastroenterological
- Lesions for which en bloc resection with snare EMR would be difficult to apply; ii. Mucosal tumors with submucosal fibrosis; iii. Sporadic tumors in conditions of chronic inflammation; iv. Local residual or recurrent early carcinomas after endoscopic resection.
Key exclusion criteria (8 listed)
- No informed consent available.
- Carcinoma of colon or rectum with invasion to submucosa or beyond.
- Evidence of distant metastasis.
- Another active malignancy present.
- Pregnant.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| EndoR Surgical SystemThe EndoR Surgical System is a master-slave robotic platform designed for endoscopic surgery, featuring flexible dual arms and cognitive control system. | Device | EndoR System assisted ESD |
Primary outcome
Rate of complete (R0) resection
Time frame: 1 day
Defined as en bloc, one-piece resection with histologically confirmed tumor-free lateral and vertical margins. Unit of measure: % of procedures
32 secondary outcomes
[Safety] Rate of intraoperative bleeding
Time frame: 1 day
[Safety] Rate of adjunctive procedures
Time frame: 1 day
[Safety] All-cause mortality
Time frame: 12 months
[Safety] Rate of infection
Time frame: 30 days
[Safety] Rate of Serious Adverse Events (SAEs)
Time frame: 12 months
[Safety] Rate of SAEs - death
Time frame: 12 months
[Safety] Rate of SAEs - serious deterioration in the health
Time frame: 12 months
[Safety] Rate of SAEs - fetal complications
Time frame: 12 months
[Performance] Technical success rate
Time frame: 30 days
[Performance] Duration of instrument calibration
Time frame: 1 day
[Performance] Duration of resection
Time frame: 1 day
[Performance] Total ESD procedure time
Time frame: 1 day
[Performance] Dissection rate
Time frame: 1 day
[Performance] Histological analysis of resected specimen
Time frame: 30 days
[Performance] Proportion of time the submucosa was visualized
Time frame: 1 day
[Performance] Number of additional submucosal injections required
Time frame: 1 day
[Performance] Length of hospital stay
Time frame: up to discharge
[Performance] Rate of device deficiencies
Time frame: 1 day
[Performance] NASA Task Load Index
Time frame: 1 day
[Performance] Overall rate of intraprocedural adverse events
Time frame: 1 day
[Performance] Rate of intraprocedural adverse events - partial thickness muscle damage
Time frame: 1 day
[Performance] Rate of intraprocedural adverse events - full thickness perforation
Time frame: 1 day
[Performance] Rate of intraprocedural adverse events - hemorrhage
Time frame: 1 day
[Performance] Rate of intraprocedural adverse events - peritonitis
Time frame: 1 day
[Performance] Rate of other intra-procedural adverse events
Time frame: 1 day
[Performance] Overall rate of postprocedural adverse events
Time frame: 30 days
[Performance] Rate of postprocedural adverse events - electrocoagulation syndrome
Time frame: 30 days
[Performance] Rate of postprocedural adverse events - postoperative delayed bleeding
Time frame: 30 days
[Performance] Rate of postprocedural adverse events - post-procedure delayed perforation
Time frame: 30 days
[Performance] Rate of other post-procedural adverse events
Time frame: 30 days
[Performance] Colonoscopy findings at 6-8 months
Time frame: 6-8 months post-procedure
[Performance] Colonoscopy findings at 12-14 months
Time frame: 12-14 months post-procedure
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 12 Feb 2026.
- Background: PubMed 18072064Akahoshi K, Akahane H, Murata A, Akiba H, Oya M. Endoscopic submucosal dissection using a novel grasping type scissors forceps. Endoscopy. 2007 Dec;39(12):1103-5. doi: 10.1055/s-2007-966842.
- Background: PubMed 19911227Teoh AY, Chiu PW, Wong SK, Sung JJ, Lau JY, Ng EK. Difficulties and outcomes in starting endoscopic submucosal dissection. Surg Endosc. 2010 May;24(5):1049-54. doi: 10.1007/s00464-009-0724-8. Epub 2009 Nov 13.
- Background: PubMed 17140890Oka S, Tanaka S, Kaneko I, Mouri R, Hirata M, Kawamura T, Yoshihara M, Chayama K. Advantage of endoscopic submucosal dissection compared with EMR for early gastric cancer. Gastrointest Endosc. 2006 Dec;64(6):877-83. doi: 10.1016/j.gie.2006.03.932. Epub 2006 Sep 20.
- Background: PubMed 18577472ASGE TECHNOLOGY COMMITTEE; Kantsevoy SV, Adler DG, Conway JD, Diehl DL, Farraye FA, Kwon R, Mamula P, Rodriguez S, Shah RJ, Wong Kee Song LM, Tierney WM. Endoscopic mucosal resection and endoscopic submucosal dissection. Gastrointest Endosc. 2008 Jul;68(1):11-8. doi: 10.1016/j.gie.2008.01.037. No abstract available.
- Background: PubMed 25220842Ferlay J, Soerjomataram I, Dikshit R, Eser S, Mathers C, Rebelo M, Parkin DM, Forman D, Bray F. Cancer incidence and mortality worldwide: sources, methods and major patterns in GLOBOCAN 2012. Int J Cancer. 2015 Mar 1;136(5):E359-86. doi: 10.1002/ijc.29210. Epub 2014 Oct 9.
- Individual participant dataSharing planned: No
Related trials for Colorectal Lesions
RecruitingObservational study
Outcomes of Knife-Assisted Full-Thickness Resection for Rectal Lesions: A Multicenter Study
Colorectal Cancer
RecruitingObservational study
Characterization of Colorectal Dysplasic Lesions and Stratification of Their Evolving Risk in Inflammatory Bowel Disease Patients: a Prospective, Observational and Multicenter Study
Crohn Disease (CD), Colitis Ulcerative
Enrolling by invitation
Cold Snare Piecemeal Resection vs Cold Snare Endoscopic Mucosal Resection
Colon Polyp, Colon Adenoma
Recruiting
Screening Women With Prior HPV for Anal Neoplasia
HPV-related Lower Genital Tract Neoplasias, HPV-related Anal Neoplasias
Active, not recruitingObservational study
Microwave Ablation or Wedge Resection for the Treatment of Lung, Sarcoma and Colorectal Lesions, ALLUME Study
Lung Non-Small Cell Carcinoma, Metastatic Colorectal Carcinoma
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing EndoR Surgical System in people with Colorectal Lesions, run by Chinese University of Hong Kong at 1 site in Hong Kong.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 12 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Hong Kong. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Rate of complete (R0) resection (time frame: 1 day). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07405203, which also lists 5 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Feb 2026.