AzTrials
AzTrials

HemodyalysisAVFMONITOR POCNCT07318025

AVF-MONITOR POC Proof-of-concept Study

A study testing AVF MONITOR in people with Hemodyalysis, run by Mario Negri Institute for Pharmacological Research at 1 site in Italy.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

This is a proof-of-concept single-centre prospective longitudinal interventional study performed in AVF patients under HD treatment at the Nephrology and Dialysis Department of the ASST-Papa Giovanni XXIII (Bergamo, Italy), involving the recording of AVF sounds by the AVF-MONITOR wearable prototype device. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Hemodyalysis
What is being tested?
AVF MONITOR
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
6 participants
Where
1 siteItaly
Study dates
Mar 2026to Sep 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Provision of informed consent prior to any study specific procedures.
  • Female and/or male aged ≥ 18.
  • Patients undergoing HD with a mature and functioning native AVF.

Who cannot join

  • Patients with a history of complications related to the AVF in use.
  • Patients who use a graft or catheter to perform HD.
  • Patients with reduced life expectancy (less than 1 year).

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Italy1 site
  • ASST HPG23 - Unità di Nefrologia

    Bergamo, BG

    Simona Zerbi, M.D., +39035267111, szerbi@asst-pg23.it

    Simona Zerbi, M.D.

Other trials in Italy

About this study

Official title: AVF-MONITOR: a New Wearable Device for Vascular Access Monitoring in Hemodialysis Patients - Proof-of-concept Study

This is a proof-of-concept single-centre prospective longitudinal interventional study performed in AVF patients under HD treatment at the Nephrology and Dialysis Department of the ASST-Papa Giovanni XXIII (Bergamo, Italy), involving the recording of AVF sounds by the AVF-MONITOR wearable prototype device.

Participants will undergo a screening and enrollment visit, then follow-up visits for AVF sounds registration will be conducted once a week for all participants, prior to dialysis session, over a period of 8 weeks.

Read the detailed description

End-stage renal disease (ESRD) is an increasingly prevalent global health issue, closely linked to the aging population. The majority of individuals with ESRD requiring renal replacement therapy undergo hemodialysis (HD) treatment . A successful HD procedure requires a well-functioning vascular access (VA) to ensure a safe and durable connection between the patient's circulation and the artificial kidney. To date, VA dysfunction remains the leading cause of morbidity and hospitalization among HD patients, representing a major limitation of this treatment modality. The current recommended VA for hemodialysis is the native arteriovenous fistula (AVF), which is surgically created in the forearm by connecting a vein and an artery through an anastomosis. Although the AVF is considered the first-choice access, it is still associated with high rates of non-maturation and early failure, with up to 40% failing within the first year post-intervention, mainly due to vascular stenosis. Identifying patients at risk of AVF failure is crucial, yet current surveillance strategies remain inadequate. In practice, AVF function is rarely monitored using the gold standard Doppler ultrasound (US) after surgical creation and initiation of HD, unless nurses report significant cannulation difficulties. By that time, however, the AVF is often already occluded, requiring the urgent placement of a central venous catheter to continue HD, followed by surgical intervention to create a new AVF. Moreover, Doppler US is time-consuming and requires a dedicated nephrologist with specific imaging expertise. Furthermore, in smaller dialysis centres, the lack of access to a Doppler US machine further restricts effective surveillance.

Continuous monitoring of AVF function could enable early identification of reduced blood flow or stenosis development, allowing timely salvage intervention by interventional radiologists before the complete closure of the AVF.

Over the years, nurses and nephrologists got used to assess AVF by palpation and auscultation, qualitatively evaluating its vibration (thrill) and the sounds it emits using a stethoscope. A non-stenotic AVF typically produces a soft, continuous murmur: a strong sound during systole and a weaker one during diastole, both associated with laminar blood flow. In contrast, a malfunctioning AVF often lacks a palpable thrill and emits a systolic-only high-pitched, hissing sound caused by turbulent and disturbed blood flow. In more severe cases of stenosis, a distinct 'whistling' sound may be heard, indicating critical dysfunction or complete failure of the AVF.

Based on these clinical evidences, recent studies have revealed significant differences in the acoustic characteristics of AVF sounds, recorded with electronic stethoscopes, between functioning and non-functioning AVFs. The frequency spectra of these sounds show that patent AVFs are characterized by low-frequency sounds, whereas stenotic AVFs exhibit higher frequencies, reaching up to 700-800 Hz. Furthermore, it has been demonstrated that AVF sounds acquired with an electronic stethoscope can be used to extract key information about hemodynamic conditions, providing indications of complex flow dynamics and adequate blood volume for effective HD. These results suggest that sound analysis has significant potential to improve clinical AVF surveillance and enhance patient outcomes.

However, the monitoring technique involving the use of an electronic stethoscope requires expert personnel, as it demands numerous precautions during both sound recording (e.g., avoiding friction and excessive pressure) and analysis, which requires technical expertise. These factors limit the use of this technological solution to only a small subset of HD patients.

To overcome these limitations, a prototype wearable device called AVF-MONITOR has been designed which allows to record AVF sound, possibly enabling simple and continuous AVF surveillance. In the future, after adequate testing, AVF-MONITOR could be potentially used in a home setting, allowing patients to independently monitor their AVF function on a daily basis.

Conditions
Hemodyalysis
Being tested
AVF MONITOR
Keywords
arteriovenous fistula, hemodialysis, vascular access, monitoring, sound recording, proof-of-concept study, prototype device, vascular stenosis
Medical subject headings
Arteriovenous Fistula

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • AVF MONITORDevice

    Wearable non-invasive device consisting in an electronic platform that can acquire acoustic data by means of an analog microphone.

Study groups in NCT07318025
Study groupRoleWhat they receive
PatientsExperimentalPatients undergoing HD with a functioning native AVF
Receives: Device: AVF MONITOR

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. High-low peak ratio

    Correlation between the high-low peak ratio (HLPR) calculated from acoustic recordings obtained using the AVF-MONITOR device (in Hz) and the gold standard electronic stethoscope (in Hz).

    Measured: Once weekly for 8 weeks after the initial screening and enrollment visit

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Jan 2026
  2. Study startMar 2026 (estimated)
  3. Primary completionSep 2026 (estimated)
  4. Study completionSep 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
6 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07318025
Sponsor's protocol ID
AVF-MONITOR POC
Acronym
AVFMONITOR POC
Status last verified
Jan 2026
First submitted
19 Dec 2025
Last updated
14 Jan 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Poloni S, Soliveri L, Caroli A, Remuzzi A, Bozzetto M. The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis. Ann Biomed Eng. 2025 Jan;53(1):230-240. doi: 10.1007/s10439-024-03638-2. Epub 2024 Nov 1.

    PubMed 39485642
  • Poloni S, Condemi CG, Peracchi T, Caroli A, Remuzzi A, Bozzetto M. Leveraging Acoustic Analysis to Detect Arteriovenous Fistula Complications. Kidney360. 2025 Oct 1;6(10):1771-1779. doi: 10.34067/KID.0000000840. Epub 2025 Jun 10.

    PubMed 40493416
  • Roy-Chaudhury P, Arend L, Zhang J, Krishnamoorthy M, Wang Y, Banerjee R, Samaha A, Munda R. Neointimal hyperplasia in early arteriovenous fistula failure. Am J Kidney Dis. 2007 Nov;50(5):782-90. doi: 10.1053/j.ajkd.2007.07.019.

    PubMed 17954291
  • Bozzetto M, Poloni S, Caroli A, Curto D, D'Haeninck A, Vanommeslaeghe F, Gjorgjievski N, Remuzzi A. The use of AVF.SIM system for the surgical planning of arteriovenous fistulae in routine clinical practice. J Vasc Access. 2023 Sep;24(5):1061-1068. doi: 10.1177/11297298211062695. Epub 2022 Jan 6.

    PubMed 34986688
  • Caroli A, Manini S, Antiga L, Passera K, Ene-Iordache B, Rota S, Remuzzi G, Bode A, Leermakers J, van de Vosse FN, Vanholder R, Malovrh M, Tordoir J, Remuzzi A; ARCH project Consortium. Validation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients. Kidney Int. 2013 Dec;84(6):1237-45. doi: 10.1038/ki.2013.188. Epub 2013 May 29.

    PubMed 23715122
  • Al-Jaishi AA, Oliver MJ, Thomas SM, Lok CE, Zhang JC, Garg AX, Kosa SD, Quinn RR, Moist LM. Patency rates of the arteriovenous fistula for hemodialysis: a systematic review and meta-analysis. Am J Kidney Dis. 2014 Mar;63(3):464-78. doi: 10.1053/j.ajkd.2013.08.023. Epub 2013 Oct 30.

    PubMed 24183112

Questions about this trial

What is this clinical trial studying?

A study testing AVF MONITOR in people with Hemodyalysis, run by Mario Negri Institute for Pharmacological Research at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 14 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Michela Bozzetto (+3903545351, michela.bozzetto@marionegri.it), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

High-low peak ratio (time frame: Once weekly for 8 weeks after the initial screening and enrollment visit). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07318025, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jan 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in