HemodyalysisAVFMONITOR POCNCT07318025
AVF-MONITOR POC Proof-of-concept Study
A study testing AVF MONITOR in people with Hemodyalysis, run by Mario Negri Institute for Pharmacological Research at 1 site in Italy.
Trial summary
This is a proof-of-concept single-centre prospective longitudinal interventional study performed in AVF patients under HD treatment at the Nephrology and Dialysis Department of the ASST-Papa Giovanni XXIII (Bergamo, Italy), involving the recording of AVF sounds by the AVF-MONITOR wearable prototype device. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Hemodyalysis
- What is being tested?
- AVF MONITOR
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 6 participants
- Where
- 1 siteItaly
- Study dates
- Mar 2026to Sep 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Provision of informed consent prior to any study specific procedures.
- Female and/or male aged ≥ 18.
- Patients undergoing HD with a mature and functioning native AVF.
Who cannot join
- Patients with a history of complications related to the AVF in use.
- Patients who use a graft or catheter to perform HD.
- Patients with reduced life expectancy (less than 1 year).
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Italy1 site
ASST HPG23 - Unità di Nefrologia
Bergamo, BG
Simona Zerbi, M.D., +39035267111, szerbi@asst-pg23.it
Simona Zerbi, M.D.
About this study
Official title: AVF-MONITOR: a New Wearable Device for Vascular Access Monitoring in Hemodialysis Patients - Proof-of-concept Study
This is a proof-of-concept single-centre prospective longitudinal interventional study performed in AVF patients under HD treatment at the Nephrology and Dialysis Department of the ASST-Papa Giovanni XXIII (Bergamo, Italy), involving the recording of AVF sounds by the AVF-MONITOR wearable prototype device.
Participants will undergo a screening and enrollment visit, then follow-up visits for AVF sounds registration will be conducted once a week for all participants, prior to dialysis session, over a period of 8 weeks.
Read the detailed description
End-stage renal disease (ESRD) is an increasingly prevalent global health issue, closely linked to the aging population. The majority of individuals with ESRD requiring renal replacement therapy undergo hemodialysis (HD) treatment . A successful HD procedure requires a well-functioning vascular access (VA) to ensure a safe and durable connection between the patient's circulation and the artificial kidney. To date, VA dysfunction remains the leading cause of morbidity and hospitalization among HD patients, representing a major limitation of this treatment modality. The current recommended VA for hemodialysis is the native arteriovenous fistula (AVF), which is surgically created in the forearm by connecting a vein and an artery through an anastomosis. Although the AVF is considered the first-choice access, it is still associated with high rates of non-maturation and early failure, with up to 40% failing within the first year post-intervention, mainly due to vascular stenosis. Identifying patients at risk of AVF failure is crucial, yet current surveillance strategies remain inadequate. In practice, AVF function is rarely monitored using the gold standard Doppler ultrasound (US) after surgical creation and initiation of HD, unless nurses report significant cannulation difficulties. By that time, however, the AVF is often already occluded, requiring the urgent placement of a central venous catheter to continue HD, followed by surgical intervention to create a new AVF. Moreover, Doppler US is time-consuming and requires a dedicated nephrologist with specific imaging expertise. Furthermore, in smaller dialysis centres, the lack of access to a Doppler US machine further restricts effective surveillance.
Continuous monitoring of AVF function could enable early identification of reduced blood flow or stenosis development, allowing timely salvage intervention by interventional radiologists before the complete closure of the AVF.
Over the years, nurses and nephrologists got used to assess AVF by palpation and auscultation, qualitatively evaluating its vibration (thrill) and the sounds it emits using a stethoscope. A non-stenotic AVF typically produces a soft, continuous murmur: a strong sound during systole and a weaker one during diastole, both associated with laminar blood flow. In contrast, a malfunctioning AVF often lacks a palpable thrill and emits a systolic-only high-pitched, hissing sound caused by turbulent and disturbed blood flow. In more severe cases of stenosis, a distinct 'whistling' sound may be heard, indicating critical dysfunction or complete failure of the AVF.
Based on these clinical evidences, recent studies have revealed significant differences in the acoustic characteristics of AVF sounds, recorded with electronic stethoscopes, between functioning and non-functioning AVFs. The frequency spectra of these sounds show that patent AVFs are characterized by low-frequency sounds, whereas stenotic AVFs exhibit higher frequencies, reaching up to 700-800 Hz. Furthermore, it has been demonstrated that AVF sounds acquired with an electronic stethoscope can be used to extract key information about hemodynamic conditions, providing indications of complex flow dynamics and adequate blood volume for effective HD. These results suggest that sound analysis has significant potential to improve clinical AVF surveillance and enhance patient outcomes.
However, the monitoring technique involving the use of an electronic stethoscope requires expert personnel, as it demands numerous precautions during both sound recording (e.g., avoiding friction and excessive pressure) and analysis, which requires technical expertise. These factors limit the use of this technological solution to only a small subset of HD patients.
To overcome these limitations, a prototype wearable device called AVF-MONITOR has been designed which allows to record AVF sound, possibly enabling simple and continuous AVF surveillance. In the future, after adequate testing, AVF-MONITOR could be potentially used in a home setting, allowing patients to independently monitor their AVF function on a daily basis.
- Conditions
- Hemodyalysis
- Being tested
- AVF MONITOR
- Keywords
- arteriovenous fistula, hemodialysis, vascular access, monitoring, sound recording, proof-of-concept study, prototype device, vascular stenosis
- Medical subject headings
- Arteriovenous Fistula
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
AVF MONITORDevice
Wearable non-invasive device consisting in an electronic platform that can acquire acoustic data by means of an analog microphone.
| Study group | Role | What they receive |
|---|---|---|
| Patients | Experimental | Patients undergoing HD with a functioning native AVF Receives: Device: AVF MONITOR |
What is being measured
The primary outcome is the main question the study is designed to answer.
High-low peak ratio
Correlation between the high-low peak ratio (HLPR) calculated from acoustic recordings obtained using the AVF-MONITOR device (in Hz) and the gold standard electronic stethoscope (in Hz).
Measured: Once weekly for 8 weeks after the initial screening and enrollment visit
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted5 Jan 2026
- Study startMar 2026 (estimated)
- Primary completionSep 2026 (estimated)
- Study completionSep 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for HemodyalysisStudies of the same condition, open and under way.
- More trials run by Mario Negri Institute for Pharmacological ResearchThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 6 participants (estimated)
Sponsor and investigators
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Giuseppe Remuzzi, M.D., Study director, Istituto Di Ricerche Farmacologiche Mario Negri
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07318025
- Sponsor's protocol ID
- AVF-MONITOR POC
- Acronym
- AVFMONITOR POC
- Status last verified
- Jan 2026
- First submitted
- 19 Dec 2025
- Last updated
- 14 Jan 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Poloni S, Soliveri L, Caroli A, Remuzzi A, Bozzetto M. The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis. Ann Biomed Eng. 2025 Jan;53(1):230-240. doi: 10.1007/s10439-024-03638-2. Epub 2024 Nov 1.
PubMed 39485642Poloni S, Condemi CG, Peracchi T, Caroli A, Remuzzi A, Bozzetto M. Leveraging Acoustic Analysis to Detect Arteriovenous Fistula Complications. Kidney360. 2025 Oct 1;6(10):1771-1779. doi: 10.34067/KID.0000000840. Epub 2025 Jun 10.
PubMed 40493416Roy-Chaudhury P, Arend L, Zhang J, Krishnamoorthy M, Wang Y, Banerjee R, Samaha A, Munda R. Neointimal hyperplasia in early arteriovenous fistula failure. Am J Kidney Dis. 2007 Nov;50(5):782-90. doi: 10.1053/j.ajkd.2007.07.019.
PubMed 17954291Bozzetto M, Poloni S, Caroli A, Curto D, D'Haeninck A, Vanommeslaeghe F, Gjorgjievski N, Remuzzi A. The use of AVF.SIM system for the surgical planning of arteriovenous fistulae in routine clinical practice. J Vasc Access. 2023 Sep;24(5):1061-1068. doi: 10.1177/11297298211062695. Epub 2022 Jan 6.
PubMed 34986688Caroli A, Manini S, Antiga L, Passera K, Ene-Iordache B, Rota S, Remuzzi G, Bode A, Leermakers J, van de Vosse FN, Vanholder R, Malovrh M, Tordoir J, Remuzzi A; ARCH project Consortium. Validation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients. Kidney Int. 2013 Dec;84(6):1237-45. doi: 10.1038/ki.2013.188. Epub 2013 May 29.
PubMed 23715122Al-Jaishi AA, Oliver MJ, Thomas SM, Lok CE, Zhang JC, Garg AX, Kosa SD, Quinn RR, Moist LM. Patency rates of the arteriovenous fistula for hemodialysis: a systematic review and meta-analysis. Am J Kidney Dis. 2014 Mar;63(3):464-78. doi: 10.1053/j.ajkd.2013.08.023. Epub 2013 Oct 30.
PubMed 24183112
Study at a glance
From the registry record, last updated by the sponsor on 14 Jan 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- AVF-MONITOR: a New Wearable Device for Vascular Access Monitoring in Hemodialysis Patients - Proof-of-concept Study
- ClinicalTrials.gov ID
- NCT07318025
- Acronym / sponsor ID
- AVFMONITOR POC / AVF-MONITOR POC
- Conditions
- Hemodyalysis
- Keywords
- arteriovenous fistula, hemodialysis, vascular access, monitoring, sound recording, proof-of-concept study, prototype device, vascular stenosis
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 6 participants (estimated)
- Lead sponsor
- Mario Negri Institute for Pharmacological ResearchUniversity, hospital or other
- Study start
- Mar 2026 (estimated)
- Primary completion
- Sep 2026 (estimated)
- Study completion
- Sep 2026 (estimated)
- First posted
- 5 Jan 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a proof-of-concept single-centre prospective longitudinal interventional study performed in AVF patients under HD treatment at the Nephrology and Dialysis Department of the ASST-Papa Giovanni XXIII (Bergamo, Italy), involving the recording of AVF sounds by the AVF-MONITOR wearable prototype device.
Participants will undergo a screening and enrollment visit, then follow-up visits for AVF sounds registration will be conducted once a week for all participants, prior to dialysis session, over a period of 8 weeks.
Detailed description
End-stage renal disease (ESRD) is an increasingly prevalent global health issue, closely linked to the aging population. The majority of individuals with ESRD requiring renal replacement therapy undergo hemodialysis (HD) treatment . A successful HD procedure requires a well-functioning vascular access (VA) to ensure a safe and durable connection between the patient's circulation and the artificial kidney. To date, VA dysfunction remains the leading cause of morbidity and hospitalization among HD patients, representing a major limitation of this treatment modality. The current recommended VA for hemodialysis is the native arteriovenous fistula (AVF), which is surgically created in the forearm by connecting a vein and an artery through an anastomosis. Although the AVF is considered the first-choice access, it is still associated with high rates of non-maturation and early failure, with up to 40% failing within the first year post-intervention, mainly due to vascular stenosis. Identifying patients at risk of AVF failure is crucial, yet current surveillance strategies remain inadequate. In practice, AVF function is rarely monitored using the gold standard Doppler ultrasound (US) after surgical creation and initiation of HD, unless nurses report significant cannulation difficulties. By that time, however, the AVF is often already occluded, requiring the urgent placement of a central venous catheter to continue HD, followed by surgical intervention to create a new AVF. Moreover, Doppler US is time-consuming and requires a dedicated nephrologist with specific imaging expertise. Furthermore, in smaller dialysis centres, the lack of access to a Doppler US machine further restricts effective surveillance.
Continuous monitoring of AVF function could enable early identification of reduced blood flow or stenosis development, allowing timely salvage intervention by interventional radiologists before the complete closure of the AVF.
Over the years, nurses and nephrologists got used to assess AVF by palpation and auscultation, qualitatively evaluating its vibration (thrill) and the sounds it emits using a stethoscope. A non-stenotic AVF typically produces a soft, continuous murmur: a strong sound during systole and a weaker one during diastole, both associated with laminar blood flow. In contrast, a malfunctioning AVF often lacks a palpable thrill and emits a systolic-only high-pitched, hissing sound caused by turbulent and disturbed blood flow. In more severe cases of stenosis, a distinct 'whistling' sound may be heard, indicating critical dysfunction or complete failure of the AVF.
Based on these clinical evidences, recent studies have revealed significant differences in the acoustic characteristics of AVF sounds, recorded with electronic stethoscopes, between functioning and non-functioning AVFs. The frequency spectra of these sounds show that patent AVFs are characterized by low-frequency sounds, whereas stenotic AVFs exhibit higher frequencies, reaching up to 700-800 Hz. Furthermore, it has been demonstrated that AVF sounds acquired with an electronic stethoscope can be used to extract key information about hemodynamic conditions, providing indications of complex flow dynamics and adequate blood volume for effective HD. These results suggest that sound analysis has significant potential to improve clinical AVF surveillance and enhance patient outcomes.
However, the monitoring technique involving the use of an electronic stethoscope requires expert personnel, as it demands numerous precautions during both sound recording (e.g., avoiding friction and excessive pressure) and analysis, which requires technical expertise. These factors limit the use of this technological solution to only a small subset of HD patients.
To overcome these limitations, a prototype wearable device called AVF-MONITOR has been designed which allows to record AVF sound, possibly enabling simple and continuous AVF surveillance. In the future, after adequate testing, AVF-MONITOR could be potentially used in a home setting, allowing patients to independently monitor their AVF function on a daily basis.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Patients | Experimental | Device: AVF MONITORPatients undergoing HD with a functioning native AVF |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Provision of informed consent prior to any study specific procedures.
- Female and/or male aged ≥ 18.
- Patients undergoing HD with a mature and functioning native AVF.
Key exclusion criteria (3 listed)
- Patients with a history of complications related to the AVF in use.
- Patients who use a graft or catheter to perform HD.
- Patients with reduced life expectancy (less than 1 year).
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| AVF MONITORWearable non-invasive device consisting in an electronic platform that can acquire acoustic data by means of an analog microphone. | Device | Patients |
Primary outcome
High-low peak ratio
Time frame: Once weekly for 8 weeks after the initial screening and enrollment visit
Correlation between the high-low peak ratio (HLPR) calculated from acoustic recordings obtained using the AVF-MONITOR device (in Hz) and the gold standard electronic stethoscope (in Hz).
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Jan 2026.
- Background: PubMed 39485642Poloni S, Soliveri L, Caroli A, Remuzzi A, Bozzetto M. The Potential of Sound Analysis to Reveal Hemodynamic Conditions of Arteriovenous Fistulae for Hemodialysis. Ann Biomed Eng. 2025 Jan;53(1):230-240. doi: 10.1007/s10439-024-03638-2. Epub 2024 Nov 1.
- Background: PubMed 40493416Poloni S, Condemi CG, Peracchi T, Caroli A, Remuzzi A, Bozzetto M. Leveraging Acoustic Analysis to Detect Arteriovenous Fistula Complications. Kidney360. 2025 Oct 1;6(10):1771-1779. doi: 10.34067/KID.0000000840. Epub 2025 Jun 10.
- Background: PubMed 17954291Roy-Chaudhury P, Arend L, Zhang J, Krishnamoorthy M, Wang Y, Banerjee R, Samaha A, Munda R. Neointimal hyperplasia in early arteriovenous fistula failure. Am J Kidney Dis. 2007 Nov;50(5):782-90. doi: 10.1053/j.ajkd.2007.07.019.
- Background: PubMed 34986688Bozzetto M, Poloni S, Caroli A, Curto D, D'Haeninck A, Vanommeslaeghe F, Gjorgjievski N, Remuzzi A. The use of AVF.SIM system for the surgical planning of arteriovenous fistulae in routine clinical practice. J Vasc Access. 2023 Sep;24(5):1061-1068. doi: 10.1177/11297298211062695. Epub 2022 Jan 6.
- Background: PubMed 23715122Caroli A, Manini S, Antiga L, Passera K, Ene-Iordache B, Rota S, Remuzzi G, Bode A, Leermakers J, van de Vosse FN, Vanholder R, Malovrh M, Tordoir J, Remuzzi A; ARCH project Consortium. Validation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients. Kidney Int. 2013 Dec;84(6):1237-45. doi: 10.1038/ki.2013.188. Epub 2013 May 29.
- Background: PubMed 24183112Al-Jaishi AA, Oliver MJ, Thomas SM, Lok CE, Zhang JC, Garg AX, Kosa SD, Quinn RR, Moist LM. Patency rates of the arteriovenous fistula for hemodialysis: a systematic review and meta-analysis. Am J Kidney Dis. 2014 Mar;63(3):464-78. doi: 10.1053/j.ajkd.2013.08.023. Epub 2013 Oct 30.
- Individual participant dataSharing planned: No
Related trials for Hemodyalysis
Not yet recruiting
Estimation of the Prevalence of Microcirculatory Dysfunction in Uremic Cardiopathy Among Dialysis Patients
Hemodyalysis
RecruitingObservational study
Assessment of Mineral and Bone Disorders in Kidney Transplant Recipients
Hemodyalysis, Kidney Tansplant
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Giuseppe Remuzzi, M.D. study director
Istituto Di Ricerche Farmacologiche Mario Negri
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing AVF MONITOR in people with Hemodyalysis, run by Mario Negri Institute for Pharmacological Research at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 14 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Michela Bozzetto (+3903545351, michela.bozzetto@marionegri.it), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
High-low peak ratio (time frame: Once weekly for 8 weeks after the initial screening and enrollment visit). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07318025, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jan 2026.