Coronary DiseaseBIOMAG-IIINCT07258290
Safety and Clinical Performance of the Freesolve Resorbable Magnesium Scaffold (RMS) System in Subjects With Coronary Artery Lesions
A study testing Freesolve RMS and Xience DES in people with Coronary Disease and Heart Diseases, run by Teleflex at 3 sites in 2 countries.
Trial summary
The objective of this study is to assess the safety and efficacy of the Freesolve resorbable magnesium scaffold (RMS) in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to the Xience coronary drug-eluting stent (DES) system Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Coronary Disease, Heart Diseases, Cardiovascular Diseases
- What is being tested?
- Freesolve RMS and Xience DES
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 1,859 participants
- Where
- 3 sitesin 2 countries
- Study dates
- 11 Jun 2026to Jun 2033
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Clinical Inclusion Criteria:
- Subject is ≥ 18 years and ≤ 80 years of age
- Subject has provided written informed consent as approved by the Ethics Committee / Institutional Review Board (IRB) of the respective clinical site prior to the study related procedures
- Subject is eligible for PCI according to the applicable guidelines
- Subject is an acceptable candidate for coronary artery bypass surgery
- Subjects with stable or unstable angina pectoris, documented silent ischemia/abnormal physiologic testing or hemodynamically stable non-ST elevation myocardial infarction (NSTEMI) patients without angiographic evidence of thrombus at target lesion Note: STEMI patients may be eligible for the study for treatment of selected non-culprit lesions, if:
- Subject and target lesion(s) meet all inclusion and no exclusion criteria and consent occurs at least ≥ 72 hours after successful treatment of the culprit lesion(s) [lesion(s) causing the acute STEMI];
- Subject is hemodynamically stable with documented declining cardiac biomarkers;
- Target lesion(s) to be treated are not located in the culprit vessel(s) and are not culprit lesion(s)
- Subject is eligible for Dual Antiplatelet Therapy (DAPT) with aspirin plus either clopidogrel, prasugrel, ticagrelor or ticlopidine
- Documented left ventricular ejection fraction (LVEF) ≥ 30% within 6 months prior to or during the procedure (prior to randomization)
- Subject is willing and able to comply with protocol requirements, including completion of study visits for the duration of the study
Angiographic Inclusion Criteria:
- Subjects with a maximum of two single de novo target lesions each in separate native coronary arteries
- Target vessel must have a reference diameter between 2.5-4.2 mm by operator visual estimation, which may be assisted by Quantitative Coronary Angiography (QCA) / Intravascular Ultrasound (IVUS) / Optical Coherence Tomography (OCT)
- Target lesion(s) must be ≤ 36 mm in length by operator visual estimation, which may be assisted by QCA / IVUS / OCT, (or < 20 mm for target lesion(s) to be treated with a study device < 3.0 mm in diameter) and must be amenable to treatment with a single study device
- Target lesion stenosis ≥ 50% and < 100% by operator visual estimation, which may be assisted by QCA / IVUS / OCT. Target lesion stenosis < 70% by visual estimation, should have clinical justification for treatment as per local standards.
- Target lesion must have a Thrombolysis in Myocardial Infarction (TIMI) flow ≥ 1
Clinical Exclusion Criteria:
- Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study
- Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with STEMI < 72 hours prior to the index procedure Note: Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment
- Subject has undergone prior PCI within the target vessel during the last 12 months prior to the index procedure or prior PCI within a non-target vessel < 72 hours prior to the index procedure
- Subject is on dialysis or has impaired renal function (serum creatinine > 2.5 mg/dL or 221 µmol/L, determined within 7 days prior to the index procedure)
- Subject has a known allergy to contrast medium that cannot be adequately premedicated, or any known allergy to aspirin, P2Y12 inhibitors, both heparin and bivalirudin, sirolimus, everolimus (or similar limus drugs), poly L-lactide, the scaffold material (magnesium, aluminum, tantalum), or Xience stent material (cobalt, chromium, tungsten, nickel, methacrylic polymer, and fluoropolymer)
- Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted)
- Life expectancy less than 1 year
- Planned surgery or dental surgical procedure within 6 months after index procedure, unless DAPT can be maintained
- In the investigator's opinion subject will not be able to comply with the follow-up requirements
- Subjects under oral anticoagulation therapy (OAC) prior to index procedure unless DAPT + OAC (i.e., triple therapy) can be maintained for a minimum of 1 month
- Subject has had a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure
- Subject with active bleeding disorder, active coagulopathy, or any other reason, who is ineligible for DAPT
- Subject is currently participating or plans to participate in another study with an investigational device or an investigational drug
- Subject has known severe aortic or mitral valve stenosis/insufficiency or has previously undergone transcatheter aortic valve replacement (TAVR)
Angiographic Exclusion Criteria:
- Target vessel has been previously treated and the target lesion is within 5 mm proximal or distal to the previously treated lesion
- Left main coronary artery disease
- Target lesion is totally occluded (100% stenosis)
- Thrombus in target vessel
- Future planned staged PCI either in target or non-target vessel
- Ostial target lesion within the left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA) (within 5.0 mm of vessel origin)
- Target lesion involves a side branch ≥ 2.0 mm in diameter that requires a two-device strategy after pre-dilatation
- Target lesion is located in or supplied by an arterial or venous bypass graft
- Target lesion with excessive tortuosity proximal to or within the lesion based on visual estimation or heavily calcified target lesion which cannot be adequately pre-dilated by a non-compliant and/or cutting/scoring balloon as described in angiographic exclusion criteria 10
- Target lesion requires treatment with a device other than the non-compliant balloon and/or cutting/scoring balloon prior to scaffold/stent placement (including but not limited to atherectomy devices, intravascular lithotripsy, drug-coated balloons, etc.)
- Target vessel was treated with brachytherapy any time prior to the index procedure.
- Unsuccessful pre-dilatation, defined as residual stenosis > 20% (by visual estimation) and/or angiographic complications (e.g., distal embolization, side branch closure, flow-limiting dissections)
Trial locations and contacts
3 sites in 2 countries. Contact the study team or a site near you to ask about taking part.
3 sites in 2 countries
United States2 sites, 2 recruiting
- Recruiting
Charleston Area Medical Center
Charleston, West Virginia, 25304
- Recruiting
MedStar Washington Hospital Center
Washington D.C., District of Columbia, 20010
Latvia1 site, 1 recruiting
- Recruiting
Pauls Stradins Clinical University Hospital
Riga, LV-1002
About this study
Official title: Safety and Clinical Performance of the Drug Eluting Resorbable Coronary Magnesium Scaffold System (Freesolve) in the Treatment of Subjects With de Novo Lesions in Native Coronary Arteries
The objective of this study is to assess the safety and efficacy of the Freesolve resorbable magnesium scaffold (RMS) in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to the Xience coronary drug-eluting stent (DES) system
Read the detailed description
The BIOMAG-III clinical trial is a prospective, international, multi-center, single-blinded, randomized controlled, non-inferiority trial to compare the Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (Freesolve RMS) System with the Xience Everolimus Eluting Stent (Xience DES) System. with respect to Target Lesion Failure (TLF) rate at 12 months. Subjects will be randomized in a 2:1 fashion Freesolve to Xience. A total of up to 1859 subjects will be randomized at up to 120 total sites worldwide including North America, Europe, and Asia Pacific. Clinical follow-up will be conducted at 1, 6, and 12 months and at 2, 3, 4, and 5 years post-procedure.
- Conditions
- Coronary Disease, Heart Diseases, Cardiovascular Diseases, Arteriosclerosis, Arterial Occlusive Diseases, Vascular Diseases
- Being tested
- Freesolve RMS, Xience DES
- Keywords
- Resorbable Magnesium Scaffold, Sirolimus, RMS, Drug eluting absorbable metal scaffold
- Medical subject headings
- Coronary Disease, Heart Diseases, Cardiovascular Diseases, Arteriosclerosis, Arterial Occlusive Diseases, Vascular Diseases, Chest Pain, Pain
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Freesolve RMSDevice
Freesolve Sirolimus-Eluting Coronary Resorbable Magnesium Scaffold (RMS) System, a drug-eluting balloon-expandable resorbable scaffold
Xience DESDevice
Xience Everolimus Eluting Stent System
| Study group | Role | What they receive |
|---|---|---|
| Freesolve RMS | Experimental | Intervention with a Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (RMS) System Receives: Device: Freesolve RMS |
| Xience DES | Active comparator | Intervention with a Xience Everolimus Eluting Stent System Receives: Device: Xience DES |
What is being measured
The primary outcome is the main question the study is designed to answer.
Target Lesion Failure (TLF) rate at 12 months post-index procedure
The primary endpoint is Target Lesion Failure (TLF) at 12 months, a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven target lesion revascularization (TLR).
Measured: 12 months
Secondary outcomes (14)
Procedure success
Procedure success defined as achievement of < 30% final residual diameter stenosis [by Quantitative Coronary Angiography (QCA) or visual estimation] of the target lesion using the assigned study device only, without the occurrence of cardiac death, Q-wave or non-Q-wave MI, or repeat revascularization of the target lesion during the hospital stay
Measured: Hospital Discharge (6-24 hours post-index procedure)
Device Success
Device Success defined as a final residual diameter stenosis of < 30% by QCA or visual estimation, using the assigned device only with
- successful delivery of the device to the target lesion, and
- appropriate device deployment, and
- successful removal of the delivery system
Measured: Hospital Discharge (6-24 hours post-index procedure)
Target lesion failure (TLF)
TLF is defined as a composite of Cardiac Death, Target Vessel Q-wave or non-Q-wave myocardial infarction (MI), or clinically driven Target Lesion Revascularization (TLR)
Measured: Time Frame: 1, 6 months and 2, 3, 4 and 5 years post-index procedure
Target Vessel Failure (TVF)
Target Vessel Failure (TVF), a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven Target Vessel Revascularization (TVR)
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Cardiac death
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Cardiovascular death
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
All-cause mortality
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Target vessel MI in accordance with the primary endpoint definitions for periprocedural and non-periprocedural MI
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Any MI (including non-target vessel territory)
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Clinically driven TLR
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Clinically driven TVR
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Scaffold/stent thrombosis (definite, definite/probable, probable) according to Academic Research Consortium (ARC-2) criteria for acute, sub-acute, late, very late and cumulative scaffold/stent thrombosis
Measured: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Powered Secondary Endpoint 1: TLF from 1-5 Years
A powered secondary endpoint of cumulative TLF rates between 1 and 5 years post-procedure will be evaluated.
Measured: 1 to 5 years post-index procedure
Powered Secondary Endpoint 2: TLF at 12 Months in the Diabetic Population
A powered secondary endpoint of TLF at 12 months in the diabetic population will be evaluated.
Measured: 12 months post-index procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted2 Dec 2025
- Study start11 Jun 2026
- Primary completionJun 2029 (estimated)
- Study completionJun 2033 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 1,859 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Teleflex
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07258290
- Sponsor's protocol ID
- G230176
- Acronym
- BIOMAG-III
- Status last verified
- Nov 2025
- First submitted
- 20 Nov 2025
- Last updated
- 31 Aug 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No: No IPD sharing is planned at this time. This study evaluates an investigational device under an FDA IDE. The sponsor may consider sharing de-identified IPD under controlled access following completion of primary endpoint analysis and regulatory review. Summary results will be reported in scientific publications and public registries.
Study at a glance
From the registry record, last updated by the sponsor on 31 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Safety and Clinical Performance of the Drug Eluting Resorbable Coronary Magnesium Scaffold System (Freesolve) in the Treatment of Subjects With de Novo Lesions in Native Coronary Arteries
- ClinicalTrials.gov ID
- NCT07258290
- Acronym / sponsor ID
- BIOMAG-III / G230176
- Conditions
- Coronary Disease, Heart Diseases, Cardiovascular Diseases, Arteriosclerosis, Arterial Occlusive Diseases, Vascular Diseases
- Keywords
- Resorbable Magnesium Scaffold, Sirolimus, RMS, Drug eluting absorbable metal scaffold
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 1,859 participants (estimated)
- Lead sponsor
- TeleflexIndustry (pharma, biotech, devices)
- Study start
- 11 Jun 2026 (actual)
- Primary completion
- Jun 2029 (estimated)
- Study completion
- Jun 2033 (estimated)
- First posted
- 2 Dec 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The objective of this study is to assess the safety and efficacy of the Freesolve resorbable magnesium scaffold (RMS) in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to the Xience coronary drug-eluting stent (DES) system
Detailed description
The BIOMAG-III clinical trial is a prospective, international, multi-center, single-blinded, randomized controlled, non-inferiority trial to compare the Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (Freesolve RMS) System with the Xience Everolimus Eluting Stent (Xience DES) System. with respect to Target Lesion Failure (TLF) rate at 12 months. Subjects will be randomized in a 2:1 fashion Freesolve to Xience. A total of up to 1859 subjects will be randomized at up to 120 total sites worldwide including North America, Europe, and Asia Pacific. Clinical follow-up will be conducted at 1, 6, and 12 months and at 2, 3, 4, and 5 years post-procedure.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Freesolve RMS | Experimental | Device: Freesolve RMSIntervention with a Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (RMS) System |
| Xience DES | Active comparator | Device: Xience DESIntervention with a Xience Everolimus Eluting Stent System |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Freesolve RMSFreesolve Sirolimus-Eluting Coronary Resorbable Magnesium Scaffold (RMS) System, a drug-eluting balloon-expandable resorbable scaffold | Device | Freesolve RMS |
| Xience DESXience Everolimus Eluting Stent System | Device | Xience DES |
Primary outcome
Target Lesion Failure (TLF) rate at 12 months post-index procedure
Time frame: 12 months
The primary endpoint is Target Lesion Failure (TLF) at 12 months, a composite of Cardiac Death, Target Vessel Q-wave or non-Q wave MI, or clinically driven target lesion revascularization (TLR).
14 secondary outcomes
Procedure success
Time frame: Hospital Discharge (6-24 hours post-index procedure)
Device Success
Time frame: Hospital Discharge (6-24 hours post-index procedure)
Target lesion failure (TLF)
Time frame: Time Frame: 1, 6 months and 2, 3, 4 and 5 years post-index procedure
Target Vessel Failure (TVF)
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Cardiac death
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Cardiovascular death
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
All-cause mortality
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Target vessel MI in accordance with the primary endpoint definitions for periprocedural and non-periprocedural MI
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Any MI (including non-target vessel territory)
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Clinically driven TLR
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Clinically driven TVR
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Scaffold/stent thrombosis (definite, definite/probable, probable) according to Academic Research Consortium (ARC-2) criteria for acute, sub-acute, late, very late and cumulative scaffold/stent thrombosis
Time frame: 1, 6, 12 months and 2, 3, 4 and 5 years post-index procedure
Powered Secondary Endpoint 1: TLF from 1-5 Years
Time frame: 1 to 5 years post-index procedure
Powered Secondary Endpoint 2: TLF at 12 Months in the Diabetic Population
Time frame: 12 months post-index procedure
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 31 Aug 2026.
- Individual participant dataSharing planned: No. No IPD sharing is planned at this time. This study evaluates an investigational device under an FDA IDE. The sponsor may consider sharing de-identified IPD under controlled access following completion of primary endpoint analysis and regulatory review. Summary results will be reported in scientific publications and public registries.
Related trials for Coronary Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
RecruitingObservational study
AI-powered ECG Analysis Using Willem™ Software in High-risk Cardiac Patients (WILLEM)
Cardiomyopathies, Cardiac Arrest
RecruitingPhase 4
The Effects of Ferric Derisomaltose in Patients With Acute Heart Failure and Iron Deficiency on Exercise Capacity and Quality of Life(COREVIVE-HFrEF)
Heart Failure With Reduced Ejection Fraction, Iron Deficiency
Recruiting
Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
Aortic Stenosis Treated With TAVI, Aortic Diseases
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
3 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Freesolve RMS and Xience DES in people with Coronary Disease and Heart Diseases, run by Teleflex at 3 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 31 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in United States, Latvia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact BIOMAG-III Project Manager (1-866-246-6990, biomag_us@teleflex.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Target Lesion Failure (TLF) rate at 12 months post-index procedure (time frame: 12 months). It is what the study was designed to measure, not a finding.