AzTrials
AzTrials

CephalometryNCT07246018

Accuracy and Reliability of Artificial Intelligence Cephalometric Analysis Software Compared to Manual Tracing

An observational study of Cephalometry and Orthodontic, run by International Islamic University Malaysia at 1 site in Malaysia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study compares the accuracy and reliability of artificial intelligence (AI) software for analyzing dental X-rays to the traditional manual tracing method used by dentists. Lateral cephalometric radiographs are special X-rays of the head used in orthodontics (teeth straightening) to measure jawbone positions… Read more about this study

Who is it for?
Any age
Conditions the study is for
Cephalometry, Orthodontic, Cephalometric Analysis
What is being tested?
Manual Cephalometric Tracing and AI-Based Cephalometric Analysis (WeDoCeph Software)
How many people
40 participants
Where
1 siteMalaysia
Study dates
2 Jan 2023to 30 Jun 2023
How long will I take part?
6 Months
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: The study population consisted of radiographs from orthodontic patients at various stages of treatment, including both pretreatment (initial diagnostic) and post-treatment radiographs. All radiographs were high-quality digital or digitized lateral cephalograms suitable for landmark identification and measurement. Patients with surgical rigid fixations, orthodontic appliances visible on radiographs, or dental prostheses were excluded to ensure clear visualization of anatomical landmarks. Additionally, radiographs of very poor quality or from patients with diagnosed syndromes or craniofacial deformities were excluded to maintain consistency in anatomical structure assessment. The unit of analysis is the cephalometric radiograph rather than individual patients, as each radiograph represents a single diagnostic assessment.

Who may be able to join

  • Pretreatment/post-treatment lateral cephalometric radiographs
  • High-quality cephalograms with visible anatomical landmarks

Who cannot join

  • Patients with surgical rigid fixations, orthodontic appliances and dental prostheses visible on radiographs
  • Very poor quality/diagnostically unacceptable radiographs
  • Patients with syndromes or with craniofacial deformities

Trial locations and contacts

1 site in 1 country.

Malaysia1 site
  • Orthodontic Specialist Clinic, Kulliyyah of Dentistry

    Kuantan, Pahang, 25200

Other trials in Malaysia

About this study

Official title: The Accuracy and Reliability of Orthodontic Cephalometry Analysis Using Web-Based Artificial Intelligence Program

This study compares the accuracy and reliability of artificial intelligence (AI) software for analyzing dental X-rays to the traditional manual tracing method used by dentists.

Lateral cephalometric radiographs are special X-rays of the head used in orthodontics (teeth straightening) to measure jawbone positions, tooth angles, and facial proportions. Traditionally, orthodontists manually trace these X-rays using pencil and paper to identify key landmarks and make measurements. This manual method is time-consuming and can vary between different practitioners or even when the same practitioner measures twice.

Read more

AI-based software can automatically identify these landmarks and perform measurements instantly. This study examined 40 dental X-rays to determine if the AI software (WeDoCeph) is as accurate and more reliable than manual tracing.

Each X-ray was measured twice - once manually by a trained examiner and once by AI software - at two different times (4 weeks apart). The researchers compared 15 different measurements, including 8 angles and 7 distances, to assess accuracy and reliability.

Read the detailed description

Lateral cephalometric analysis is essential for orthodontic diagnosis and treatment planning. The traditional manual tracing method involves identifying anatomical landmarks on radiographs using pencil, ruler, and protractor, which is subjective, time-consuming, and prone to intra- and inter-observer variability.

This diagnostic accuracy study evaluated the WeDoCeph AI-based cephalometric analysis software against conventional manual tracing. The study used a comparative repeated-measures design where each radiograph was analysed by both methods at two time points (T₀ and T₁, separated by 4 weeks) to assess both accuracy and reliability.

Sample size calculation was based on 95% power and a 0.05 significance level, resulting in 40 lateral cephalometric radiographs. All measurements included angular parameters (SNA, SNB, ANB, FMPA, MMPA, UIA, LIA, IIA) and linear parameters (A-N perpendicular, POG-N perpendicular, ANS-Me, SN, UFH, MxPI, MnPI).

Paired T-Test will be employed as the statistical analysis method for comparisons and Intraclass Correlation Coefficient (ICC) for reliability assessment. The study aimed to determine whether AI-based cephalometric analysis provides sufficient accuracy and superior reliability for clinical application in orthodontic practice.

Being tested
Manual Cephalometric Tracing, AI-Based Cephalometric Analysis (WeDoCeph Software)

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Manual Cephalometric TracingDiagnostic test

    Conventional manual cephalometric analysis performed by trained examiner using traditional tracing technique. Lateral cephalometric radiographs are hand-traced in a darkened room using a view box for transillumination. A 25cm x 18cm radiographic film is used as the base, with a 21cm x 16cm matte acetate tracing paper taped over it. Hard and soft tissue cephalometric landmarks are manually identified and traced using a 0.3mm 2HB pencil. Angular measurements are obtained using a protractor, and linear measurements using a ruler. All 15 cephalometric measurements (8 angular: SNA, SNB, ANB, FMPA, MMPA, UIA, LIA, IIA; and 7 linear: A-N perpendicular, POG-N perpendicular, ANS-Me, SN, UFH, MxPI, MnPI) are calculated manually. Each radiograph is traced and analyzed twice at 4-week intervals by the same examiner to assess intra-examiner reliability.

  • AI-Based Cephalometric Analysis (WeDoCeph Software)Diagnostic test

    Automated cephalometric analysis using WeDoCeph artificial intelligence-based software. Digital lateral cephalometric radiographs are imported as high-quality JPEG images into the software platform. The AI system automatically identifies and traces cephalometric landmarks using deep learning algorithms, then instantly generates all measurements based on the predefined parameters. The same 15 cephalometric measurements obtained in manual tracing (8 angular: SNA, SNB, ANB, FMPA, MMPA, UIA, LIA, IIA; and 7 linear: A-N perpendicular, POG-N perpendicular, ANS-Me, SN, UFH, MxPI, MnPI) are automatically calculated by the software. Each radiograph is analyzed twice at 4-week intervals using the previously uploaded digital images to assess reproducibility and consistency of the AI system. No manual landmark identification or measurement calculation is required.

Study groups in NCT07246018
Study groupRoleWhat they receive
Orthodontic Patients with Lateral Cephalometric RadiographsLateral cephalometric radiographs from 40 orthodontic patients collected between January 2023 and June 2023 from the Orthodontic Specialist Clinic. Each radiograph was analyzed using both manual tracing and AI-based software (WeDoCeph) at two time points (initial and 4 weeks later)
Receives: Diagnostic Test: Manual Cephalometric Tracing; Diagnostic Test: AI-Based Cephalometric Analysis (WeDoCeph Software)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Intraclass Correlation Coefficient (ICC) for repeated manual measurements

    ICC calculated for all 15 cephalometric measurements (8 angular and 7 linear) performed manually at two time points to assess intra-examiner reliability

    Measured: Baseline (T₀) and 4 weeks later (T₁)

  2. Intraclass Correlation Coefficient (ICC) for repeated AI measurements

    ICC calculated for all 15 cephalometric measurements performed by WeDoCeph software at two time points to assess consistency

    Measured: Baseline (T₀) and 4 weeks later (T₁)

  3. Mean differences between manual and AI-based measurements at T₀

    Paired T-Test comparison of all 15 measurements between manual tracing and AI analysis at initial time point

    Measured: Baseline (T₀)

  4. Mean differences between manual and AI-based measurements at T₁

    Paired T-Test comparison of all 15 measurements between manual tracing and AI analysis at 4-week time point

    Measured: 4 weeks

Secondary outcomes (3)
  1. Angular Measurements

    Comparison of angular cephalometric measurements between methods

    Measured: Baseline (T₀) and 4 weeks (T₁)

  2. Linear Measurements

    Comparison of linear cephalometric measurements between methods

    Measured: Baseline (T₀) and 4 weeks (T₁)

  3. Inter-examiner Reliability

    10% of radiographs were analyzed by three examiners to ensure inter-examiner agreement

    Measured: During calibration phase

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Nov 2025
  2. Study start2 Jan 2023
  3. Primary completion30 Jun 2023
  4. Study completion30 Jun 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
40 participants (actual)
Target duration
6 Months
IDs, dates and publications
ClinicalTrials.gov ID
NCT07246018
Sponsor's protocol ID
IREC 2023-045
Other IDs
CHAIN 22-001-0001
Status last verified
Jan 2023
First submitted
14 Nov 2025
Last updated
24 Nov 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data will not be made publicly available to protect patient privacy and confidentiality. The study involves radiographic images and associated measurements from orthodontic patients. Even with de-identification, radiographic images may be potentially identifiable. Data sharing was not included in the original ethics approval and informed consent process. Aggregate summary data and statistical results are available in the published manuscript.

Publications

  • Alqahtani H. Evaluation of an online website-based platform for cephalometric analysis. J Stomatol Oral Maxillofac Surg. 2020 Feb;121(1):53-57. doi: 10.1016/j.jormas.2019.04.017. Epub 2019 May 3.

    PubMed 31059836
  • Kazimierczak W, Gawin G, Janiszewska-Olszowska J, Dyszkiewicz-Konwinska M, Nowicki P, Kazimierczak N, Serafin Z, Orhan K. Comparison of Three Commercially Available, AI-Driven Cephalometric Analysis Tools in Orthodontics. J Clin Med. 2024 Jun 26;13(13):3733. doi: 10.3390/jcm13133733.

    PubMed 38999299
  • Lee JH, Yu HJ, Kim MJ, Kim JW, Choi J. Automated cephalometric landmark detection with confidence regions using Bayesian convolutional neural networks. BMC Oral Health. 2020 Oct 7;20(1):270. doi: 10.1186/s12903-020-01256-7.

    PubMed 33028287

Questions about this trial

What is this clinical trial studying?

An observational study of Cephalometry and Orthodontic, run by International Islamic University Malaysia at 1 site in Malaysia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 24 Nov 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Malaysia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Intraclass Correlation Coefficient (ICC) for repeated manual measurements (time frame: Baseline (T₀) and 4 weeks later (T₁)). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07246018, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Nov 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in