HealthyPOROUS-BMDNCT07187518
Clinical Study to Estimate Bone Mineral Density With the POROUS Ultrasound Device
A study testing Measurements with the POROUS R4C ultrasound device at the midshaft tibia and DXA measurement of the hip and lumbar spine in people with Healthy and Osteopenia, run by POROUS GmbH at 2 sites in Germany.
Trial summary
Osteoporosis is a widespread medical condition among older people. It causes the bones to weaken and become more likely to break. Osteoporosis and bone fracture risk are currently evaluated by looking at clinical risk factors and measuring bone mineral density (BMD). Read more about this study
- Who is it for?
- Ages 21 to 55 yearsHealthy volunteers can take part
- Conditions the study is for
- Healthy, Osteopenia, Osteoporosis
- What is being tested?
- Measurements with the POROUS R4C ultrasound device at the midshaft tibia and DXA measurement of the hip and lumbar spine
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 350 participants
- Where
- 2 sitesGermany
- Study dates
- 14 Nov 2025to 3 Sep 2026
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 21 to 55 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- Female or male individuals aged 21 to and including 55 years.
- Written informed consent has been obtained.
Who cannot join
- Presence of diseases that rule out valid measurements with the DXA and POROUS R4C ultrasound devices (e.g., fractures or metal implants in the examined bones, paralysis of the lower extremities, severe bone abnormalities).
- Open wounds or skin infections at the measurement site of the POROUS R4C ultrasound device.
- Inability to undergo the investigations required by the Clinical Investigation Plan (CIP) or cognitive limitations that preclude understanding of the Participant Information Sheet and the Informed Consent Document.
- Pregnancy and breastfeeding
- Individual is in custody by order of an authority or a court of law.
- Close affiliation with an investigational site, e.g., employment at an investigational site, close relative of an investigator, or dependent person (e.g., student of the investigational site).
Trial locations and contacts
2 sites in 1 country.
Germany2 sites
Department of Endocrinology and Metabolism, Charité Universitätsmedizin Berlin, Campus Mitte
Berlin, 10117
Centre of Muscle and Bone Research (ZMK), Charité Universitätsmedizin Berlin, Campus Benjamin Franklin
Berlin, 12203
About this study
Official title: A Cross-sectional, Single-cohort, Bi-centre Clinical Investigation to Estimate Surrogate Bone Mineral Density (BMD) in Young and Middle-aged Men and Women Using Quantitative Ultrasound Imaging (POROUS)
Osteoporosis is a widespread medical condition among older people. It causes the bones to weaken and become more likely to break. Osteoporosis and bone fracture risk are currently evaluated by looking at clinical risk factors and measuring bone mineral density (BMD). The lower the BMD is, the higher the risk of osteoporotic fractures in the future. An X-ray device called DXA is the main tool used to diagnose osteoporosis and fracture risk clinically. DXA measures two-dimensional BMD in the hip and spine. However, DXA devices are often not readily available at the point of care.
The POROUS ultrasound device offers a different approach by measuring various properties of the outer layer of the bone in the lower leg. It has several advantages over DXA: (1) higher and three-dimensional image resolution; (2) the ability to measure bone properties without radiation; (3) portability, it is a mobile medical device; 4) lower operational costs.
Read more
For this clinical study, we will recruit men and women between the ages of 21 and 55. Most of these study participants will not have evident clinical risks for osteoporosis. The goal for including this age group is to estimate the range of BMD values for younger people before BMD declines with age. In a separate clinical study, we are recruiting older participants. The study is anticipated to last one year.
Our major research questions are:
- Can the POROUS ultrasound device estimate BMD?
- How does its performance compare to DXA?
- What is the safety of the new device?
The participants will:
- answer questions about their medical history.
- be measured for height and weight.
- be examined with the two devices, DXA and POROUS.
Read the detailed description
Medical background and current standard of care:
Osteoporosis is defined as a systemic skeletal disease characterized by low mineral bone mass and microarchitectural deterioration of bone tissue (Consensus Conference, 1994). This increased bone fragility is associated with susceptibility to fractures, which have substantial economic and societal burdens. Osteoporosis is routinely diagnosed through bone density assessments; however, there is a shortage of accurate means to characterize bone microstructure for diagnostic purposes. The POROUS R4C ultrasound device is capable of providing such information in detail.
The current standard of care (SoC) physical bone parameter for examining bone health is areal BMD (aBMD), typically measured by dual-energy X-ray absorptiometry (DXA) at the hip or spine. Scaling is given to score the patient's aBMD in comparison to a reference of a healthy bone. The resulting T Score compares the patient's aBMD to the peak aBMD of young adults of the same sex, while the Z score compares it to the average aBMD of the same age and sex. According to the operational WHO definition (1994), a T Score of -1.0 or above is considered normal, while scores between -1.0 and -2.5 indicate osteopenia, and scores of -2.5 or lower indicate osteoporosis.
The rationale for the clinical investigation:
Quantitative ultrasound (QUS) devices have several substantial advantages over X-ray-based technologies: a better safety profile (non-ionizing radiation), cost-efficiency, usability, and portability. These advantages can result in improved accessibility at point-of-care. The major challenge is, nonetheless, clinical performance. QUS devices that assess bone health have demonstrated varying performance in estimating surrogate aBMD values. aBMD estimation is calculated by empirical correlation with DXA reference measurements using a combination of ultrasound parameters and anthropometric information. We follow these clinical performance standards for aBMD estimation using the investigational POROUS R4C ultrasound device.
The investigational device:
The POROUS R4C is a non-invasive QUS device for measuring and quantifying microstructural, acoustic, and viscoelastic properties in cortical bone (e.g., in the tibia of the lower limb). The device can be used to acquire single-channel raw data in a pulse-echo mode and perform innovative signal processing and imaging techniques to determine physical bone biomarkers. Examples of physical bone biomarkers are cortical thickness and the speed of sound in the radial direction using refraction-corrected image reconstruction and frequency-dependent attenuation and pore-size distribution using spectral backscatter analysis. The measurement data are recorded by the acquisition software, and the post-processing analysis is done using separate algorithms. In pre-clinical and clinical studies (completed, ongoing, or planned), the effectiveness of spectral ultrasound backscatter analysis and refraction-corrected image reconstruction methods are being evaluated to assess bone quality, health, and biomechanical competence. In first-in-human pilot studies, the POROUS technology has demonstrated the feasibility of measuring cortical bone properties and estimating aBMD in smaller cohorts of participants.
The overall purpose of the clinical investigation:
In this confirmatory clinical investigation, data will be collected to characterize cortical bone properties and calculate surrogate aBMD values for young and middle-aged (21 to 55 years) men and women. In a separate confirmatory clinical investigation (POROUS-preFX, NCT06567054), data will be collected to characterize cortical properties and calculate surrogate aBMD values in older men and women (56 to 85 years). Together, the combined data will represent a broader range of estimated surrogate aBMD values and generate a POROUS T score for diagnostic purposes.
Clinical investigation design:
This is a cross-sectional, single-cohort, age- and sex-stratified study of participants aged 21 to 55 years. The rationale for selecting this age range is to gather data for this age group, while data from older participants are gathered in an independent clinical investigation (POROUS-preFX, NCT06567054).
Participants will be enrolled into different groups based on their age (consisting of five-year bands) and sex (males or females). All participants will undergo measurements using the investigational POROUS R4C ultrasound device and the comparator DXA device. Prior knowledge of aBMD values, whether measured by DXA or another type of bone densitometer, will not be recorded to avoid selection bias. The final analysis of study results will incorporate measured POROUS parameters (e.g., cortical thickness, cortical bone pore diameter distribution, cortical bone frequency-dependent ultrasound attenuation, cortical bone backscatter coefficient, speed of sound in the radial direction), anthropometric information (weight, height, BMI, sex), and age will be used to create a multivariate partial least squares (PLS) model to predict DXA-derived aBMD. This prediction model will be similar to the one described in the pilot studies (Armbrecht et al., JBMR Plus, 2021; Dehnen et al., Front Endocrinol, 2024). However, the formula will be re-developed based on the results of this study. The predictions will be made with DXA-derived aBMD values of the femur neck, total proximal femur, and lumbar spine collected in this study. Cross-calibration of DXA devices from different manufacturers will be done if necessary.
The participants will also receive a questionnaire regarding their medical history and any medications that may impact bone health.
Primary objective:
- To assess the performance of the POROUS R4C ultrasound device in estimating surrogate aBMD values (total femur).
Secondary objectives:
- To assess the performance of the POROUS R4C ultrasound device in estimating surrogate aBMD values (femoral neck and lumbar spine).
- To assess the safety of the POROUS R4C ultrasound device by monitoring adverse events affecting participants or healthcare professionals using the device.
Exploratory objectives:
- To generate T-score and Z-score scales (total femur, femoral neck, and lumbar spine) for the POROUS R4C ultrasound device and assess their performance.
- To collect data on cortical bone properties measured by POROUS R4C ultrasound device in young and middle-aged men and women.
- To assess the reproducibility of direct measurements by the POROUS R4C
Participants:
The clinical investigation will include 350 female and male participants. Prior knowledge of bone health or aBMD values will not be considered an enrolment criterion. All participants will undergo measurement using the investigational POROUS R4C ultrasound device at the midshaft tibia and a comparator DXA device at the total femur, femoral neck, and lumbar spine. The participants are stratified according to sex and age stratification into five-year bands:
- Age group 21-25, males/females = 25 per group, total = 50.
- Age group 26-30, males/females = 25 per group, total = 50.
- Age group 31-35, males/females = 25 per group, total = 50.
- Age group 36-40, males/females = 25 per group, total = 50.
- Age group 41-45, males/females = 25 per group, total = 50.
- Age group 46-50, males/females = 25 per group, total = 50.
- Age group 31-55, males/females = 25 per group, total = 50.
Screened and eligible individuals will be enrolled in the investigation until the necessary sample size for his/her corresponding group (based on age and sex) has been reached (see Table above). To avoid over-recruiting, once the necessary sample size for one group has been reached, no further individuals with matching age band or sex will be enrolled in the investigation.
Duration of the clinical investigation:
The planned overall clinical investigation is expected to last up to 12 months, from the first participant's enrolment until the last participant's clinical assessment. However, if the last participant's assessment is completed before the 12-month mark, the Sponsor may choose to conclude the investigation earlier.
Clinical procedures:
The following clinical procedures are performed during the investigation:
Screening:
- Inclusion/exclusion criteria
- Enrolment into corresponding age and sex groups.
- Informed consent
Clinical assessments:
- Measuring with the POROUS R4C ultrasound device at the central antero-medial tibia region
- Scanning with DXA (aBMD of the lumbar spine and proximal femur).
- Assessment of medical conditions and concomitant medication using a questionnaire.
- Recording of adverse events.
- Conditions
- Healthy, Osteopenia, Osteoporosis
- Being tested
- Measurements with the POROUS R4C ultrasound device at the midshaft tibia, DXA measurement of the hip and lumbar spine
- Keywords
- Osteoporosis, Osteopenia, Bone Tissue, Diagnostic Imaging, Ultrasound, Ultrasonography, Ultrasonic Diagnosis, DEXA Scan, DXA Scan, Dual X-Ray Absorptiometry, Bone Fractures, Osteoporotic Fractures, Hip Fractures, Spinal Fractures, Bone Mineral Density
- Medical subject headings
- Bone Diseases, Metabolic, Osteoporosis, Fractures, Bone, Osteoporotic Fractures, Hip Fractures, Spinal Fractures
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Measurements with the POROUS R4C ultrasound device at the midshaft tibiaDevice
The POROUS R4C ultrasound device measures the cortical bone of the midshaft tibia. Ultrasound gel is first applied onto the skin surface, covering the region of interest, followed by placing the ultrasound transducer with a medical ultrasound gel pad placed in front of it. At the marked position on the leg, four technical measurement readings are performed: 2x CortBS and 2x Multifocus, with repositioning the probe between individual measurements, the chronological order of which is not crucial. Scanning time for each measurement takes 1-2 minutes. Out of the four measurements, the two optimal measurements (one for CortBS and one for Multifocus) are selected by the device, based on pre-defined quality criteria.
DXA measurement of the hip and lumbar spineDevice
The following DXA measurements are to be performed: • Spine L1-4 • Hip left • Hip right (alternatively, if a valid measurement of the left hip is not possible) Scanning takes approximately 15 minutes. A maximum number of one repeat measurement is planned (e.g., hip or spine). Note: The DXA scan of the hip is performed on the same side of the body as the POROUS R4C ultrasound scan.
| Study group | Role | What they receive |
|---|---|---|
| BMD estimation in young and middle-aged men and women | Experimental | All participants are examined with the investigational device (POROUS R4C ultrasound device) and a comparator device (DXA). Receives: Device: Measurements with the POROUS R4C ultrasound device at the midshaft tibia; Device: DXA measurement of the hip and lumbar spine |
What is being measured
The primary outcome is the main question the study is designed to answer.
Primary Clinical Endpoint - POROUS
Assessment of the POROUS R4C ultrasound device in estimating surrogate aBMD values (total femur). The primary endpoint aims to obtain a statistically significant correlation between the surrogate POROUS-aBMD values and the respective DXA-aBMD values (total femur). Outcome measure: POROUS-aBMD (g/cm^2).
Measured: 12 months
Primary Clinical Endpoint - DXA
Outcome measure: DXA-aBMD values - total femur (g/cm^2)
Measured: 12 months
Secondary outcomes (3)
Secondary Clinical Endpoint - POROUS
Assessment of the POROUS R4C ultrasound device in estimating surrogate aBMD values (femoral neck and lumbar spine). The secondary endpoint aims to obtain a statistically significant correlation between the surrogate POROUS-aBMD values and the respective DXA-aBMD values (femoral neck and lumbar spine). Outcome measure: POROUS-aBMD (g/cm^2).
Measured: 12 months
Secondary Clinical Endpoint - DXA
Outcome measure: DXA-aBMD values - femoral neck and lumbar spine (g/cm^2)
Measured: 12 months
Safety Endpoint: Incidence of procedural/device-related adverse events
In order to establish that the POROUS R4C ultrasound device is safe with a minimal number of adverse events affecting the participants or the healthcare professionals using the device, the following safety endpoints are investigated: • Incidence of procedural/device-related adverse events caused by the o Absorbed energy o Probe/transducer heating o Irritation by ultrasound gel o Release of substances o Inappropriate hygiene measures. • Other (serious) adverse events.
Measured: 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Sep 2025
- Study start14 Nov 2025
- Primary completion3 Sep 2026
- Study completion3 Sep 2026
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for HealthyStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Comparative, single-cohort, interventional study model: investigational device vs. comparator device.
- Masking
- None (open label)
- Enrolment
- 350 participants (actual)
Sponsor and investigators
- Lead sponsor
- POROUS GmbH
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- German Federal Ministry of Education and Research
- Responsible party
- Sponsor
- Investigators
- Gabriele Armbrecht, MD, PhD, Principal investigator, Charite University, Berlin, Germany
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07187518
- Sponsor's protocol ID
- R4C-BMD-01
- Other IDs
- 13GW0807
- Acronym
- POROUS-BMD
- Status last verified
- Sep 2026
- First submitted
- 15 Sep 2025
- Last updated
- 18 Sep 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Dehnen C, Galindo A, Hoff P, Palme O, Maurer L, Raum K, Wiebe E. Quantitative ultrasound imaging reveals distinct fracture-associated differences in tibial intracortical pore morphology and viscoelastic properties in aged individuals with and without diabetes mellitus - an exploratory study. Front Endocrinol (Lausanne). 2024 Dec 16;15:1474546. doi: 10.3389/fendo.2024.1474546. eCollection 2024.
PubMed 39736865Armbrecht G, Nguyen Minh H, Massmann J, Raum K. Pore-Size Distribution and Frequency-Dependent Attenuation in Human Cortical Tibia Bone Discriminate Fragility Fractures in Postmenopausal Women With Low Bone Mineral Density. JBMR Plus. 2021 Sep 2;5(11):e10536. doi: 10.1002/jbm4.10536. eCollection 2021 Nov.
PubMed 34761144
Study at a glance
From the registry record, last updated by the sponsor on 18 Sep 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Cross-sectional, Single-cohort, Bi-centre Clinical Investigation to Estimate Surrogate Bone Mineral Density (BMD) in Young and Middle-aged Men and Women Using Quantitative Ultrasound Imaging (POROUS)
- ClinicalTrials.gov ID
- NCT07187518
- Acronym / sponsor ID
- POROUS-BMD / R4C-BMD-01
- Conditions
- Healthy, Osteopenia, Osteoporosis
- Keywords
- Osteoporosis, Osteopenia, Bone Tissue, Diagnostic Imaging, Ultrasound, Ultrasonography, Ultrasonic Diagnosis, DEXA Scan
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 350 participants (actual)
- Lead sponsor
- POROUS GmbHIndustry (pharma, biotech, devices)
- Collaborators
- German Federal Ministry of Education and Research
- Study start
- 14 Nov 2025 (actual)
- Primary completion
- 3 Sep 2026 (actual)
- Study completion
- 3 Sep 2026 (actual)
- First posted
- 23 Sep 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Osteoporosis is a widespread medical condition among older people. It causes the bones to weaken and become more likely to break. Osteoporosis and bone fracture risk are currently evaluated by looking at clinical risk factors and measuring bone mineral density (BMD). The lower the BMD is, the higher the risk of osteoporotic fractures in the future. An X-ray device called DXA is the main tool used to diagnose osteoporosis and fracture risk clinically. DXA measures two-dimensional BMD in the hip and spine. However, DXA devices are often not readily available at the point of care.
The POROUS ultrasound device offers a different approach by measuring various properties of the outer layer of the bone in the lower leg. It has several advantages over DXA: (1) higher and three-dimensional image resolution; (2) the ability to measure bone properties without radiation; (3) portability, it is a mobile medical device; 4) lower operational costs.
For this clinical study, we will recruit men and women between the ages of 21 and 55. Most of these study participants will not have evident clinical risks for osteoporosis. The goal for including this age group is to estimate the range of BMD values for younger people before BMD declines with age. In a separate clinical study, we are recruiting older participants. The study is anticipated to last one year.
Our major research questions are:
- Can the POROUS ultrasound device estimate BMD?
- How does its performance compare to DXA?
- What is the safety of the new device?
The participants will:
- answer questions about their medical history.
- be measured for height and weight.
- be examined with the two devices, DXA and POROUS.
Detailed description
Medical background and current standard of care:
Osteoporosis is defined as a systemic skeletal disease characterized by low mineral bone mass and microarchitectural deterioration of bone tissue (Consensus Conference, 1994). This increased bone fragility is associated with susceptibility to fractures, which have substantial economic and societal burdens. Osteoporosis is routinely diagnosed through bone density assessments; however, there is a shortage of accurate means to characterize bone microstructure for diagnostic purposes. The POROUS R4C ultrasound device is capable of providing such information in detail.
The current standard of care (SoC) physical bone parameter for examining bone health is areal BMD (aBMD), typically measured by dual-energy X-ray absorptiometry (DXA) at the hip or spine. Scaling is given to score the patient's aBMD in comparison to a reference of a healthy bone. The resulting T Score compares the patient's aBMD to the peak aBMD of young adults of the same sex, while the Z score compares it to the average aBMD of the same age and sex. According to the operational WHO definition (1994), a T Score of -1.0 or above is considered normal, while scores between -1.0 and -2.5 indicate osteopenia, and scores of -2.5 or lower indicate osteoporosis.
The rationale for the clinical investigation:
Quantitative ultrasound (QUS) devices have several substantial advantages over X-ray-based technologies: a better safety profile (non-ionizing radiation), cost-efficiency, usability, and portability. These advantages can result in improved accessibility at point-of-care. The major challenge is, nonetheless, clinical performance. QUS devices that assess bone health have demonstrated varying performance in estimating surrogate aBMD values. aBMD estimation is calculated by empirical correlation with DXA reference measurements using a combination of ultrasound parameters and anthropometric information. We follow these clinical performance standards for aBMD estimation using the investigational POROUS R4C ultrasound device.
The investigational device:
The POROUS R4C is a non-invasive QUS device for measuring and quantifying microstructural, acoustic, and viscoelastic properties in cortical bone (e.g., in the tibia of the lower limb). The device can be used to acquire single-channel raw data in a pulse-echo mode and perform innovative signal processing and imaging techniques to determine physical bone biomarkers. Examples of physical bone biomarkers are cortical thickness and the speed of sound in the radial direction using refraction-corrected image reconstruction and frequency-dependent attenuation and pore-size distribution using spectral backscatter analysis. The measurement data are recorded by the acquisition software, and the post-processing analysis is done using separate algorithms. In pre-clinical and clinical studies (completed, ongoing, or planned), the effectiveness of spectral ultrasound backscatter analysis and refraction-corrected image reconstruction methods are being evaluated to assess bone quality, health, and biomechanical competence. In first-in-human pilot studies, the POROUS technology has demonstrated the feasibility of measuring cortical bone properties and estimating aBMD in smaller cohorts of participants.
The overall purpose of the clinical investigation:
In this confirmatory clinical investigation, data will be collected to characterize cortical bone properties and calculate surrogate aBMD values for young and middle-aged (21 to 55 years) men and women. In a separate confirmatory clinical investigation (POROUS-preFX, NCT06567054), data will be collected to characterize cortical properties and calculate surrogate aBMD values in older men and women (56 to 85 years). Together, the combined data will represent a broader range of estimated surrogate aBMD values and generate a POROUS T score for diagnostic purposes.
Clinical investigation design:
This is a cross-sectional, single-cohort, age- and sex-stratified study of participants aged 21 to 55 years. The rationale for selecting this age range is to gather data for this age group, while data from older participants are gathered in an independent clinical investigation (POROUS-preFX, NCT06567054).
Participants will be enrolled into different groups based on their age (consisting of five-year bands) and sex (males or females). All participants will undergo measurements using the investigational POROUS R4C ultrasound device and the comparator DXA device. Prior knowledge of aBMD values, whether measured by DXA or another type of bone densitometer, will not be recorded to avoid selection bias. The final analysis of study results will incorporate measured POROUS parameters (e.g., cortical thickness, cortical bone pore diameter distribution, cortical bone frequency-dependent ultrasound attenuation, cortical bone backscatter coefficient, speed of sound in the radial direction), anthropometric information (weight, height, BMI, sex), and age will be used to create a multivariate partial least squares (PLS) model to predict DXA-derived aBMD. This prediction model will be similar to the one described in the pilot studies (Armbrecht et al., JBMR Plus, 2021; Dehnen et al., Front Endocrinol, 2024). However, the formula will be re-developed based on the results of this study. The predictions will be made with DXA-derived aBMD values of the femur neck, total proximal femur, and lumbar spine collected in this study. Cross-calibration of DXA devices from different manufacturers will be done if necessary.
The participants will also receive a questionnaire regarding their medical history and any medications that may impact bone health.
Primary objective:
- To assess the performance of the POROUS R4C ultrasound device in estimating surrogate aBMD values (total femur).
Secondary objectives:
- To assess the performance of the POROUS R4C ultrasound device in estimating surrogate aBMD values (femoral neck and lumbar spine).
- To assess the safety of the POROUS R4C ultrasound device by monitoring adverse events affecting participants or healthcare professionals using the device.
Exploratory objectives:
- To generate T-score and Z-score scales (total femur, femoral neck, and lumbar spine) for the POROUS R4C ultrasound device and assess their performance.
- To collect data on cortical bone properties measured by POROUS R4C ultrasound device in young and middle-aged men and women.
- To assess the reproducibility of direct measurements by the POROUS R4C
Participants:
The clinical investigation will include 350 female and male participants. Prior knowledge of bone health or aBMD values will not be considered an enrolment criterion. All participants will undergo measurement using the investigational POROUS R4C ultrasound device at the midshaft tibia and a comparator DXA device at the total femur, femoral neck, and lumbar spine. The participants are stratified according to sex and age stratification into five-year bands:
- Age group 21-25, males/females = 25 per group, total = 50.
- Age group 26-30, males/females = 25 per group, total = 50.
- Age group 31-35, males/females = 25 per group, total = 50.
- Age group 36-40, males/females = 25 per group, total = 50.
- Age group 41-45, males/females = 25 per group, total = 50.
- Age group 46-50, males/females = 25 per group, total = 50.
- Age group 31-55, males/females = 25 per group, total = 50.
Screened and eligible individuals will be enrolled in the investigation until the necessary sample size for his/her corresponding group (based on age and sex) has been reached (see Table above). To avoid over-recruiting, once the necessary sample size for one group has been reached, no further individuals with matching age band or sex will be enrolled in the investigation.
Duration of the clinical investigation:
The planned overall clinical investigation is expected to last up to 12 months, from the first participant's enrolment until the last participant's clinical assessment. However, if the last participant's assessment is completed before the 12-month mark, the Sponsor may choose to conclude the investigation earlier.
Clinical procedures:
The following clinical procedures are performed during the investigation:
Screening:
- Inclusion/exclusion criteria
- Enrolment into corresponding age and sex groups.
- Informed consent
Clinical assessments:
- Measuring with the POROUS R4C ultrasound device at the central antero-medial tibia region
- Scanning with DXA (aBMD of the lumbar spine and proximal femur).
- Assessment of medical conditions and concomitant medication using a questionnaire.
- Recording of adverse events.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Comparative, single-cohort, interventional study model: investigational device vs. comparator device.
| Arm | Type | Receives |
|---|---|---|
| BMD estimation in young and middle-aged men and women | Experimental | Device: Measurements with the POROUS R4C ultrasound device at the midshaft tibia, Device: DXA measurement of the hip and lumbar spineAll participants are examined with the investigational device (POROUS R4C ultrasound device) and a comparator device (DXA). |
Who may qualify
- Ages
- 21 to 55 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (2 listed)
- Female or male individuals aged 21 to and including 55 years.
- Written informed consent has been obtained.
Key exclusion criteria (6 listed)
- Presence of diseases that rule out valid measurements with the DXA and POROUS R4C ultrasound devices (e.g., fractures or metal implants in the examined bones, paralysis of the lower extremities, severe bone abnormalities).
- Open wounds or skin infections at the measurement site of the POROUS R4C ultrasound device.
- Inability to undergo the investigations required by the Clinical Investigation Plan (CIP) or cognitive limitations that preclude understanding of the Participant Information Sheet and the Informed Consent Document.
- Pregnancy and breastfeeding
- Individual is in custody by order of an authority or a court of law.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Measurements with the POROUS R4C ultrasound device at the midshaft tibiaThe POROUS R4C ultrasound device measures the cortical bone of the midshaft tibia. Ultrasound gel is first applied onto the skin surface, covering the region of interest, followed by placing the ultrasound transducer with a medical ultrasound gel pad placed in front of it. At the marked position on the leg, four technical measurement readings are performed: 2x CortBS and 2x Multifocus, with repositioning the probe between individual measurements, the chronological order of which is not crucial. Scanning time for each measurement takes 1-2 minutes. Out of the four measurements, the two optimal measurements (one for CortBS and one for Multifocus) are selected by the device, based on pre-defined quality criteria. | Device | BMD estimation in young and middle-aged men and women |
| DXA measurement of the hip and lumbar spineThe following DXA measurements are to be performed: • Spine L1-4 • Hip left • Hip right (alternatively, if a valid measurement of the left hip is not possible) Scanning takes approximately 15 minutes. A maximum number of one repeat measurement is planned (e.g., hip or spine). Note: The DXA scan of the hip is performed on the same side of the body as the POROUS R4C ultrasound scan. | Device | BMD estimation in young and middle-aged men and women |
Primary outcome
Primary Clinical Endpoint - POROUS
Time frame: 12 months
Assessment of the POROUS R4C ultrasound device in estimating surrogate aBMD values (total femur). The primary endpoint aims to obtain a statistically significant correlation between the surrogate POROUS-aBMD values and the respective DXA-aBMD values (total femur). Outcome measure: POROUS-aBMD (g/cm^2).
Primary Clinical Endpoint - DXA
Time frame: 12 months
Outcome measure: DXA-aBMD values - total femur (g/cm^2)
3 secondary outcomes
Secondary Clinical Endpoint - POROUS
Time frame: 12 months
Secondary Clinical Endpoint - DXA
Time frame: 12 months
Safety Endpoint: Incidence of procedural/device-related adverse events
Time frame: 12 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 18 Sep 2026.
- Background: PubMed 39736865Dehnen C, Galindo A, Hoff P, Palme O, Maurer L, Raum K, Wiebe E. Quantitative ultrasound imaging reveals distinct fracture-associated differences in tibial intracortical pore morphology and viscoelastic properties in aged individuals with and without diabetes mellitus - an exploratory study. Front Endocrinol (Lausanne). 2024 Dec 16;15:1474546. doi: 10.3389/fendo.2024.1474546. eCollection 2024.
- Background: PubMed 34761144Armbrecht G, Nguyen Minh H, Massmann J, Raum K. Pore-Size Distribution and Frequency-Dependent Attenuation in Human Cortical Tibia Bone Discriminate Fragility Fractures in Postmenopausal Women With Low Bone Mineral Density. JBMR Plus. 2021 Sep 2;5(11):e10536. doi: 10.1002/jbm4.10536. eCollection 2021 Nov.
- Individual participant dataSharing planned: No
Related trials for Healthy
Recruiting
THE EFFECTS OF GAME-BASED EXERCISE PROGRAMS
Physical Activity, Body Image
Not yet recruitingPhase 1
A Phase I Study of GLR2053 Tablets in Chinese Healthy Adult Participants
Atopic Dermatitis
Recruiting
Colon-delivered Riboflavin and Gut Microbiota Composition
Microbiome Dysbiosis, Gut Health
Not yet recruiting
Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)
Healthy Volunteers - Male and Female
RecruitingPhase 1
First-in-Human Trial to Assess REGN20423 in Healthy Adult Participants and Adult Participants With Atopic Dermatitis
Healthy Volunteer, Atopic Dermatitis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Gabriele Armbrecht, MD, PhD principal investigator
Charite University, Berlin, Germany
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Measurements with the POROUS R4C ultrasound device at the midshaft tibia and DXA measurement of the hip and lumbar spine in people with Healthy and Osteopenia, run by POROUS GmbH at 2 sites in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 18 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Primary Clinical Endpoint - POROUS (time frame: 12 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07187518, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Sep 2026.