Flabby RidgeNCT07108322
Digital Versus Conventional Impression in Edentulous Patients With Flabby Ridge.
A study testing Intraoral scanning in people with Flabby Ridge and Edentulous Alveolar Ridge, run by Delta University for Science and Technology at 1 site in Egypt.
Trial summary
The main goal of complete denture prosthodontics is to restore function, comfort, and aesthetics by replacing missing teeth and supporting structures. Flabby ridges, defined as mobile soft tissue on the alveolar ridge, pose challenges in creating stable dentures, as these tissues can displace under occlusal forces… Read more about this study
- Who is it for?
- Ages 50 to 75 years
- Conditions the study is for
- Flabby Ridge, Edentulous Alveolar Ridge
- What is being tested?
- Intraoral scanning
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 26 participants
- Where
- 1 siteEgypt
- Study dates
- 30 Mar 2023to 25 Jun 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 50 to 75 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Completely edentulous patients with maxillary flabby ridge
- Absence of infectious diseases
- Systemic good health (ASA-1/ASA-2)
- Age between 50 and 75 years
- Willingness to cooperate throughout the data collection process.
Who cannot join
- Presence of any remaining teeth
- Inability to comprehend the study's objectives and procedures
- ridge defect or lesion
- Postoperative scarring on the ridge
- Limitations in mouth opening.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Clinical Evaluation of Digital Versus Conventional Impression in Edentulous Patients With Flabby Ridge. A Randomized Controlled Clinical Trial
The main goal of complete denture prosthodontics is to restore function, comfort, and aesthetics by replacing missing teeth and supporting structures. Flabby ridges, defined as mobile soft tissue on the alveolar ridge, pose challenges in creating stable dentures, as these tissues can displace under occlusal forces, compromising retention and support. Special impression techniques are necessary to manage flabby ridges effectively One widely accepted method is the window technique, which uses double spacers and window in the flabby tissue area. However, this technique is technically complex. This RCT aims to evaluate whether intraoral scanning (IOS) provides an alternative to the window technique for recording maxillary flabby ridges.
The hypothesis was that IOS will demonstrate superior clinical results in terms of both Retention and Patient satisfaction compared to the conventional window technique impression (WTI).
Read the detailed description
Participants and setting A total of 26 participants who met all pre-defined inclusion criteria were consecutively enrolled in the study. All eligible patients presenting to the outpatient clinic at the Department of Prosthodontics, Delta University for Science and Technology, during the defined recruitment period were screened for inclusion.
Design The study utilized a crossover design, where participants were randomly assigned to receive complete dentures fabricated by using two different techniques for complete denture fabrication: Group I dentures were fabricated using the conventional window technique impression and Group II denture were fabricated using Digital impression technique. A new complete denture was delivered for each participant after 6 months, with those initially receiving Group I dentures transitioning to Group II dentures, and vice versa.
Randomization The randomization sequence was generated by a statistician using a computer-generated list of random numbers at a 1:1 allocation ratio, independent of the study's clinical team. A non-clinical assistant, who was not involved in patient recruitment or assessment, prepared the opaque, sequentially numbered, sealed envelopes and was responsible for their safekeeping in a locked cabinet. The Principal Investigator (D.E.) was responsible for screening and enrolling eligible participants. Assignment was performed by an independent dental assistant immediately prior to implementing the assigned impression technique by opening the next sequential envelope, thus ensuring adequate allocation concealment.
Interventions For Group I dentures, Window Technique Impression was employed to make the final impression, and the sequence of steps was as follows: The primary alginate impression of the edentulous maxilla was made with stock edentulous trays. Anterior maxillary flabby tissue was palpated and identified intraorally using large ball burnisher and outlined with an indelible pencil. The impression was repositioned in the patient's mouth and the markings made with an indelible pencil were transferred onto the impression surface. The impression was then poured using Type III dental stone, and one sheet of modeling wax was adapted as a spacer.
Border molding of the custom trays were made using tracing compound to capture functional extension. Then the custom tray was opened in the area of flabby tissues guided by the indelible pencil marks on the primary cast. Zinc oxide eugenol paste was loaded onto the tray to record the non-flabby tissues, ensuring detailed and stable impressions of these areas. A light coat of impression plaster was applied on the flabby ridge area using a small brush through the window area. Because the window exposes the flabby tissue, plaster captures its detail without compressing or displacing it, thereby preventing dislodgement of the denture during function and improving stability. The window technique impression was then scanned using a desktop extra-oral scanner. The scanner is equipped with four 5 MP cameras and Blue LED Multi-line technology, achieving an accuracy of 5 μm (ISO) / 8 μm. Prior to analysis, artifacts such as air bubbles and voids on the palatal surface of the WTI models were digitally removed to fabricate a 3D-printed model.
For Group II dentures, a digital impression of maxillary arch was made using an IOS to obtain the test files. Specialized soft tissue scan retractor was constructed with a resilient yet sufficiently rigid framework to fit into the vestibular area, allowing unobstructed movement of the scan head which is essential for obtaining precise intraoral data without soft tissue interference.16 Before scanning, a meticulous cleansing of the edentulous ridge was performed, followed by the removal of any residual saliva.
The scanning process for the maxillary arch started at the ridge's crest on one side and proceeded along the residual ridge until reaching the canine-incisor region. At this point, a zig-zag scanning pattern was performed to capture both the crest and the anterior palatal slope. The pathway then continued in a straight line along the ridge's crest to the other side. Subsequently, the scanner head was turned to capture the buccal aspect, moving in a straight line to the opposite buccal side. Scanning then covered the palatal incline of the tuberosity and advanced anteriorly along the posterior palatal incline until it reached the previously scanned anterior palatal slope. Finally, scanning continued in a backward direction across to the opposite side, ensuring complete coverage of the entire palatal region. The systematic scanning pathway used for all cases is important for the creation of accurate digital models that form the basis of manufactured prosthesis.
Diagram for the scanning pathway employed The resultant STL files of the scan of the window technique impression and the IOS of the maxillary arch were exported to a RapidShape D30 2016 3D-printer to produce 3D-printed models of the maxillary arch. The 3D-printed models were then duplicated by enclosing the models within a mold box ensuring it is positioned securely. Silicone molding material was mixed and poured into the box completely encasing the 3D-models until the silicone was cured. The 3D-printed cast was carefully removed from the silicone mold. Type III dental stone was mixed and poured into the silicone mold ensuring it filled all fine details and allowed to harden completely.
3D-printed cast duplicated into stone cast For both Groups, the final impression of the mandibular arch was made using border molding with green stick compound and Zn oxide and eugenol final impression material. All the conventional steps of complete denture construction then proceeded. . After the initial wax-up, the denture was verified in the patient's mouth before being processed using the compression molding technique with conventional heat-cured acrylic resin. The dentures for both groups (Conventional and Digital) were fabricated by a single, experienced dental technician. The technician was not blinded to the impression type but was instructed to use identical materials and processing techniques for the final dentures. The IOS operator (D.E.) had extensive prior experience before the trial commenced, thereby minimizing the impact of the learning curve on the results. A single operator performed all scans to reduce inter-operator variability.
On the day of denture delivery, the complete denture was checked for fit, borders, extensions and occlusion. Group I dentures were delivered to the patients. After 6 months of functional denture use and a washout period of 48 hours, Group II dentures were delivered.
Outcomes The primary endpoint of this crossover trial is the difference between the two techniques (Digital vs. Conventional) in OHRQoL as measured by the OHIP-EDENT-19 questionnaire at T0, T3 and T6. The secondary endpoint is the difference in maxillary denture retention at the same time points.
Each patient was asked to fill a questionnaire at T0 and T3, T6. OHIP-EDENT-19 was used to assess the OHRQoL. We used the Arabic version of OHIP-EDENT-19, whose psychometric properties in completely edentulous older adults have been validated. The profile consisted of 19 questions, each with a score of 0 to 4 (impaired) on the Likert scale The denture retention was measured at T0, T3, and T6 by a digital force gauge device, which measures tension or compression force (pull/push) to values up to 980 N. The snap loop of the device engaged a screw that was fixed to the geometric center of the denture bases with self-curing acrylic resin to avoid heat-induced distortion of the denture base, thus maintaining the integrity of the base adaptation. The geometric center is typically located by marking the midline of the maxillary cast, drawn from the center of the incisive papilla extending posteriorly to the midpoint of a line connecting the two hamular notches. The midpoint on this midline represents the geometric center of the maxillary arch. This point is used as a stable and balanced reference for placing attachments or screws.
The rigor of the outcome measurement for denture retention was ensured by following a standardized, quantifiable methodology utilizing a digital force gauge. Retention was evaluated by performing five consecutive pulls at each designated time point. For each pull, the peak dislodging force (the maximum resistance recorded before complete displacement) was registered by the gauge. A rest interval of 60 seconds was enforced between each pull, allowing for soft tissue recovery and the re-establishment of the crucial salivary film required for reliable physical retention measurement. The retention force was applied to a custom-fabricated attachment loop on the denture and pulled by the force gauge in a vertical direction, directly opposite to the denture's path of insertion. To eliminate kinetic or inertial errors, the force was applied at a constant, slow rate of approximately 50 mm/minute until dislodgement. Finally, the reported retention value for each time point was calculated as the mean (average) of the peak forces recorded from the five consecutive pulls, which is a common practice to minimize measurement variability and ensure the final reading is highly representative of the prosthetic retention. The device was used within its manufacturer-recommended calibration cycle to ensure accurate measurement. The instrument was newly calibrated prior to the start of the trial.
A single, calibrated examiner performed all measurements; thus eliminating inter-examiner variability. The intra-examiner reliability was assessed prior to the study using the Intra-class Correlation Coefficient (ICC), which showed high reliability (ICC > 0.90).
Statistics A statistical analysis plan was performed. Comparison between groups was made using paired t-test, while comparison between different time points was performed by using Repeated Measures ANOVA test followed by Tukey's Post Hoc test. The significant level was set to be at P ≤ 0.05.
- Conditions
- Flabby Ridge, Edentulous Alveolar Ridge
- Being tested
- Intraoral scanning
- Keywords
- Flabby ridge, Edentulous, Maxillary, digital scanning
- Medical subject headings
- Mouth, Edentulous
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Intraoral scanningOther
Adigital impression with intraoral scanning
| Study group | Role | What they receive |
|---|---|---|
| Edentulous maxillary arch with flabby ridge | Other | Conventional impression followed by intraoral scanning Receives: Other: Intraoral scanning |
What is being measured
The primary outcome is the main question the study is designed to answer.
patient satisfaction
A questionnaire will be provided to score Oral Health Related Quality of Life . The scoring system used a Likert scale where a lower score indicates a better perceived quality of life, as the minimum possible score is 0 and the maximum is 76 (higher score indicating more impairment).
Measured: Baseline, 3 months and 6 months
Secondary outcomes (1)
Retention
The denture retention was measured by a digital force gauge device, which measures tension or compression force (pull/push) to values up to 980 N.
Measured: Baseline, 3 months and 6 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Aug 2025
- Study start30 Mar 2023
- Primary completion29 Apr 2025
- Study completion25 Jun 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Flabby RidgeStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Health services research
- Allocation
- Not applicable
- Intervention model
- Sequential
- Masking
- None (open label)
- Enrolment
- 26 participants (actual)
Sponsor and investigators
- Lead sponsor
- Delta University for Science and Technology
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Dina M. ElAwady, PHD, Principal investigator, Associate Professor of Prosthodontics
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07108322
- Sponsor's protocol ID
- FODMRC-2023-00111
- Status last verified
- Jul 2025
- First submitted
- 4 Aug 2025
- Last updated
- 15 Dec 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: Till the article is published
Publications
Elawady DM, Abdel-Moneim AY, Ibrahim WI, Matta S. Clinical evaluation of digital versus conventional impression in edentulous patients with flabby ridges: a randomized controlled clinical trial. BMC Oral Health. 2026 Jan 12;26(1):187. doi: 10.1186/s12903-025-07524-8.
PubMed 41527085
Study at a glance
From the registry record, last updated by the sponsor on 15 Dec 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Evaluation of Digital Versus Conventional Impression in Edentulous Patients With Flabby Ridge. A Randomized Controlled Clinical Trial
- ClinicalTrials.gov ID
- NCT07108322
- Acronym / sponsor ID
- FODMRC-2023-00111
- Conditions
- Flabby Ridge, Edentulous Alveolar Ridge
- Keywords
- Flabby ridge, Edentulous, Maxillary, digital scanning
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 26 participants (actual)
- Lead sponsor
- Delta University for Science and TechnologyUniversity, hospital or other
- Study start
- 30 Mar 2023 (actual)
- Primary completion
- 29 Apr 2025 (actual)
- Study completion
- 25 Jun 2025 (actual)
- First posted
- 7 Aug 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The main goal of complete denture prosthodontics is to restore function, comfort, and aesthetics by replacing missing teeth and supporting structures. Flabby ridges, defined as mobile soft tissue on the alveolar ridge, pose challenges in creating stable dentures, as these tissues can displace under occlusal forces, compromising retention and support. Special impression techniques are necessary to manage flabby ridges effectively One widely accepted method is the window technique, which uses double spacers and window in the flabby tissue area. However, this technique is technically complex. This RCT aims to evaluate whether intraoral scanning (IOS) provides an alternative to the window technique for recording maxillary flabby ridges.
The hypothesis was that IOS will demonstrate superior clinical results in terms of both Retention and Patient satisfaction compared to the conventional window technique impression (WTI).
Detailed description
Participants and setting A total of 26 participants who met all pre-defined inclusion criteria were consecutively enrolled in the study. All eligible patients presenting to the outpatient clinic at the Department of Prosthodontics, Delta University for Science and Technology, during the defined recruitment period were screened for inclusion.
Design The study utilized a crossover design, where participants were randomly assigned to receive complete dentures fabricated by using two different techniques for complete denture fabrication: Group I dentures were fabricated using the conventional window technique impression and Group II denture were fabricated using Digital impression technique. A new complete denture was delivered for each participant after 6 months, with those initially receiving Group I dentures transitioning to Group II dentures, and vice versa.
Randomization The randomization sequence was generated by a statistician using a computer-generated list of random numbers at a 1:1 allocation ratio, independent of the study's clinical team. A non-clinical assistant, who was not involved in patient recruitment or assessment, prepared the opaque, sequentially numbered, sealed envelopes and was responsible for their safekeeping in a locked cabinet. The Principal Investigator (D.E.) was responsible for screening and enrolling eligible participants. Assignment was performed by an independent dental assistant immediately prior to implementing the assigned impression technique by opening the next sequential envelope, thus ensuring adequate allocation concealment.
Interventions For Group I dentures, Window Technique Impression was employed to make the final impression, and the sequence of steps was as follows: The primary alginate impression of the edentulous maxilla was made with stock edentulous trays. Anterior maxillary flabby tissue was palpated and identified intraorally using large ball burnisher and outlined with an indelible pencil. The impression was repositioned in the patient's mouth and the markings made with an indelible pencil were transferred onto the impression surface. The impression was then poured using Type III dental stone, and one sheet of modeling wax was adapted as a spacer.
Border molding of the custom trays were made using tracing compound to capture functional extension. Then the custom tray was opened in the area of flabby tissues guided by the indelible pencil marks on the primary cast. Zinc oxide eugenol paste was loaded onto the tray to record the non-flabby tissues, ensuring detailed and stable impressions of these areas. A light coat of impression plaster was applied on the flabby ridge area using a small brush through the window area. Because the window exposes the flabby tissue, plaster captures its detail without compressing or displacing it, thereby preventing dislodgement of the denture during function and improving stability. The window technique impression was then scanned using a desktop extra-oral scanner. The scanner is equipped with four 5 MP cameras and Blue LED Multi-line technology, achieving an accuracy of 5 μm (ISO) / 8 μm. Prior to analysis, artifacts such as air bubbles and voids on the palatal surface of the WTI models were digitally removed to fabricate a 3D-printed model.
For Group II dentures, a digital impression of maxillary arch was made using an IOS to obtain the test files. Specialized soft tissue scan retractor was constructed with a resilient yet sufficiently rigid framework to fit into the vestibular area, allowing unobstructed movement of the scan head which is essential for obtaining precise intraoral data without soft tissue interference.16 Before scanning, a meticulous cleansing of the edentulous ridge was performed, followed by the removal of any residual saliva.
The scanning process for the maxillary arch started at the ridge's crest on one side and proceeded along the residual ridge until reaching the canine-incisor region. At this point, a zig-zag scanning pattern was performed to capture both the crest and the anterior palatal slope. The pathway then continued in a straight line along the ridge's crest to the other side. Subsequently, the scanner head was turned to capture the buccal aspect, moving in a straight line to the opposite buccal side. Scanning then covered the palatal incline of the tuberosity and advanced anteriorly along the posterior palatal incline until it reached the previously scanned anterior palatal slope. Finally, scanning continued in a backward direction across to the opposite side, ensuring complete coverage of the entire palatal region. The systematic scanning pathway used for all cases is important for the creation of accurate digital models that form the basis of manufactured prosthesis.
Diagram for the scanning pathway employed The resultant STL files of the scan of the window technique impression and the IOS of the maxillary arch were exported to a RapidShape D30 2016 3D-printer to produce 3D-printed models of the maxillary arch. The 3D-printed models were then duplicated by enclosing the models within a mold box ensuring it is positioned securely. Silicone molding material was mixed and poured into the box completely encasing the 3D-models until the silicone was cured. The 3D-printed cast was carefully removed from the silicone mold. Type III dental stone was mixed and poured into the silicone mold ensuring it filled all fine details and allowed to harden completely.
3D-printed cast duplicated into stone cast For both Groups, the final impression of the mandibular arch was made using border molding with green stick compound and Zn oxide and eugenol final impression material. All the conventional steps of complete denture construction then proceeded. . After the initial wax-up, the denture was verified in the patient's mouth before being processed using the compression molding technique with conventional heat-cured acrylic resin. The dentures for both groups (Conventional and Digital) were fabricated by a single, experienced dental technician. The technician was not blinded to the impression type but was instructed to use identical materials and processing techniques for the final dentures. The IOS operator (D.E.) had extensive prior experience before the trial commenced, thereby minimizing the impact of the learning curve on the results. A single operator performed all scans to reduce inter-operator variability.
On the day of denture delivery, the complete denture was checked for fit, borders, extensions and occlusion. Group I dentures were delivered to the patients. After 6 months of functional denture use and a washout period of 48 hours, Group II dentures were delivered.
Outcomes The primary endpoint of this crossover trial is the difference between the two techniques (Digital vs. Conventional) in OHRQoL as measured by the OHIP-EDENT-19 questionnaire at T0, T3 and T6. The secondary endpoint is the difference in maxillary denture retention at the same time points.
Each patient was asked to fill a questionnaire at T0 and T3, T6. OHIP-EDENT-19 was used to assess the OHRQoL. We used the Arabic version of OHIP-EDENT-19, whose psychometric properties in completely edentulous older adults have been validated. The profile consisted of 19 questions, each with a score of 0 to 4 (impaired) on the Likert scale The denture retention was measured at T0, T3, and T6 by a digital force gauge device, which measures tension or compression force (pull/push) to values up to 980 N. The snap loop of the device engaged a screw that was fixed to the geometric center of the denture bases with self-curing acrylic resin to avoid heat-induced distortion of the denture base, thus maintaining the integrity of the base adaptation. The geometric center is typically located by marking the midline of the maxillary cast, drawn from the center of the incisive papilla extending posteriorly to the midpoint of a line connecting the two hamular notches. The midpoint on this midline represents the geometric center of the maxillary arch. This point is used as a stable and balanced reference for placing attachments or screws.
The rigor of the outcome measurement for denture retention was ensured by following a standardized, quantifiable methodology utilizing a digital force gauge. Retention was evaluated by performing five consecutive pulls at each designated time point. For each pull, the peak dislodging force (the maximum resistance recorded before complete displacement) was registered by the gauge. A rest interval of 60 seconds was enforced between each pull, allowing for soft tissue recovery and the re-establishment of the crucial salivary film required for reliable physical retention measurement. The retention force was applied to a custom-fabricated attachment loop on the denture and pulled by the force gauge in a vertical direction, directly opposite to the denture's path of insertion. To eliminate kinetic or inertial errors, the force was applied at a constant, slow rate of approximately 50 mm/minute until dislodgement. Finally, the reported retention value for each time point was calculated as the mean (average) of the peak forces recorded from the five consecutive pulls, which is a common practice to minimize measurement variability and ensure the final reading is highly representative of the prosthetic retention. The device was used within its manufacturer-recommended calibration cycle to ensure accurate measurement. The instrument was newly calibrated prior to the start of the trial.
A single, calibrated examiner performed all measurements; thus eliminating inter-examiner variability. The intra-examiner reliability was assessed prior to the study using the Intra-class Correlation Coefficient (ICC), which showed high reliability (ICC > 0.90).
Statistics A statistical analysis plan was performed. Comparison between groups was made using paired t-test, while comparison between different time points was performed by using Repeated Measures ANOVA test followed by Tukey's Post Hoc test. The significant level was set to be at P ≤ 0.05.
Study design
- Primary purpose
- Health services research
- Allocation
- Not applicable
- Intervention model
- Sequential
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Edentulous maxillary arch with flabby ridge | Other | Other: Intraoral scanningConventional impression followed by intraoral scanning |
Who may qualify
- Ages
- 50 to 75 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Completely edentulous patients with maxillary flabby ridge
- Absence of infectious diseases
- Systemic good health (ASA-1/ASA-2)
- Age between 50 and 75 years
- Willingness to cooperate throughout the data collection process.
Key exclusion criteria (5 listed)
- Presence of any remaining teeth
- Inability to comprehend the study's objectives and procedures
- ridge defect or lesion
- Postoperative scarring on the ridge
- Limitations in mouth opening.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Intraoral scanningAdigital impression with intraoral scanning | Other | Edentulous maxillary arch with flabby ridge |
Primary outcome
patient satisfaction
Time frame: Baseline, 3 months and 6 months
A questionnaire will be provided to score Oral Health Related Quality of Life . The scoring system used a Likert scale where a lower score indicates a better perceived quality of life, as the minimum possible score is 0 and the maximum is 76 (higher score indicating more impairment).
1 secondary outcome
Retention
Time frame: Baseline, 3 months and 6 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Dec 2025.
- Derived from this study: PubMed 41527085Elawady DM, Abdel-Moneim AY, Ibrahim WI, Matta S. Clinical evaluation of digital versus conventional impression in edentulous patients with flabby ridges: a randomized controlled clinical trial. BMC Oral Health. 2026 Jan 12;26(1):187. doi: 10.1186/s12903-025-07524-8.
- Individual participant dataSharing planned: No. Till the article is published
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Dina M. ElAwady, PHD principal investigator
Associate Professor of Prosthodontics
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Intraoral scanning in people with Flabby Ridge and Edentulous Alveolar Ridge, run by Delta University for Science and Technology at 1 site in Egypt.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 15 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
patient satisfaction (time frame: Baseline, 3 months and 6 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07108322, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Dec 2025.