Partially Edentulous JawNCT07061418
3D Evaluation of Free-handed-Countersink Guided and Fully Guided Implant Surgery in Partially Edentulous Patients
A study testing Dental Implant in people with Partially Edentulous Jaw and Accuracy of Dental Implant Placement, run by Islamic University of Caza, Gaza, Palestine at 1 site in Palestinian Territories.
Trial summary
This clinical trial with a quasi-experimental design investigates the accuracy of dental implant placement using three different surgical approaches: free-handed countersink guided, fully-guided, and traditional freehand techniques in partially edentulous patients. Read more about this study
- Who is it for?
- Ages 18 to 53 years
- Conditions the study is for
- Partially Edentulous Jaw, Accuracy of Dental Implant Placement, Implant Deviation and Positioning Errors
- What is being tested?
- Dental Implant
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 1 sitePalestinian Territories
- Study dates
- 23 Feb 2023to 25 May 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 53 years
- All sexes
- No healthy volunteers
- Adult
Who may be able to join
- Partially dentate adults with at least 6 remaining teeth
- The anticipated presence of sufficient bone volume allowing for implant placement with no simultaneous bone grafting
- Extractions within 2 months of welding.
- Want the missing tooth to be replaced by an implant
- Adequate related attached mucosa was found
- Mouth opening ≥ 40 mm
- Good oral hygiene
- Good general health
Who cannot join
- Heavy smoking
- Physical or psychiatric disorders preventing the implant treatment.
- Previous radiotherapy of the head-neck region
- Younger than 18 years
Trial locations and contacts
1 site in 1 country.
Palestinian Territories1 site
Al-Azhar University
Gaza, Gaza Strip, 00970
About this study
Official title: 3D Evaluation the Accuracy of Free-Handed-Countersink Guided and Fully-Guided Implant Surgery in Partially Edentulous Patients: A Clinical Trial With Quasi-experimental Study
This clinical trial with a quasi-experimental design investigates the accuracy of dental implant placement using three different surgical approaches: free-handed countersink guided, fully-guided, and traditional freehand techniques in partially edentulous patients. Dental implant therapy not only requires successful osseointegration but also a precise three-dimensional placement to ensure functional and esthetic outcomes. Accurate implant positioning is vital to prevent complications and ensure long-term stability. The evolution of digital technology has led to the development of computer-assisted implant surgery, enhancing surgical precision and minimizing the chances of deviation from planned positions.
In this study, implants were placed in the same patients on both sides of the jaw using two techniques for comparison - one side received a free-handed countersink guided implant, while the other used a fully-guided surgical guide. Patients included in this research were partially dentate adults with adequate oral health, bone volume, and no systemic conditions or habits that could interfere with healing. Pre-operative and post-operative cone-beam computed tomography (CBCT) scans were used to evaluate the positional accuracy of the implants.
Read more
The three-dimensional evaluation method utilized Blue Sky Plan 4 and 3D Slicer software to superimpose and analyze implant placements. Parameters such as angular deviation, crestal global deviation, apical global deviation, vertical linear deviation, lateral linear deviation, apical vertical deviation, apical lateral deviation, and distances from anatomical structures like the inferior alveolar nerve and the maxillary sinus were measured to assess placement accuracy. Measurements were taken using automatic image registration and STL superimposition of planned versus actual implant locations.
Data collected was analyzed using SPSS software. Both descriptive and inferential statistical analyses were conducted. The results aimed to determine the accuracy differences between countersink-guided and fully-guided implant techniques. The findings of this study contribute to evidence-based clinical decisions in implant dentistry by exploring if countersink-guided approaches offer comparable accuracy to fully-guided methods, thus supporting safer and more effective dental implant procedures in clinical practice.
Read the detailed description
This clinical trial with a quasi-experimental study design explores the comparative accuracy of dental implant placement using three different surgical protocols in partially edentulous patients: free-handed countersink guided, fully-guided, and traditional freehand methods. The precision of implant positioning plays a pivotal role in the long-term success and aesthetics of dental implant therapy. Although osseointegration is fundamental, optimal functional and esthetic outcomes are contingent upon the precise three-dimensional positioning of the implant within the jawbone. The rationale behind this study stems from the clinical observation that improper implant placement can result in technical and biological complications, leading to treatment failure or compromised prosthetic outcomes.
The advent of digital imaging and surgical planning has revolutionized implant dentistry. Traditional radiographic stents and manual implant placement methods have been increasingly replaced by static computer-assisted implant surgery (s-CAIS), allowing for improved preoperative visualization and enhanced implant positioning accuracy. In the digital workflow, combining intraoral scans with cone-beam computed tomography (CBCT) enables clinicians to plan implant positions based on bone quality, soft tissue contours, and the spatial relationship with adjacent teeth or anatomical landmarks.
Despite these advancements, there remains a lack of clinical evidence on the performance of countersink guided protocols specifically. Countersink guided placement involves using drills designed to widen the crestal cortical bone, especially in cases of dense bone, facilitating a passive fit of the implant at the neck. This approach is typically categorized under the freehand technique but is believed to offer enhanced stability during insertion. Fully-guided surgery, in contrast, utilizes a prefabricated guide that controls each step of the drilling and implant placement process, theoretically minimizing deviation.
The study involved the recruitment of partially dentate adults who fulfilled strict inclusion criteria such as having at least six remaining teeth, good oral hygiene, sufficient bone volume for implant placement without the need for grafting, and the ability to maintain mouth opening of at least 40 mm. Patients with parafunctional habits, heavy smoking, psychiatric or systemic conditions that contraindicate implant surgery, a history of radiotherapy in the head and neck region, or younger than 18 years of age were excluded.
Each patient received two implants-one placed with the countersink guided freehand method, and the other placed using a fully-guided surgical protocol. Both procedures were performed by the same surgeon using a parallel surgical kit (Dentsply®, MIS, M4, Germany), ensuring consistency in technique and instrumentation. The implants were placed on the same day and with identical preoperative planning to eliminate inter-operator and time-related variability.
To evaluate the accuracy of implant placement, preoperative CBCT scans were taken to plan the implant location, followed by postoperative CBCT scans after implant insertion. Digital planning and analysis were conducted using Blue Sky Plan 4 software and the 3D Slicer platform. Postoperative CBCT data was processed and segmented to extract the STL file of the actual implant placement. These files were then superimposed onto the original preoperative plan using point-based automatic registration. More than twenty anatomical and reference points were marked to ensure a precise overlay, enabling a direct comparison of the actual and planned implant positions in three-dimensional space.
The primary outcome of interest was angular deviation-the angle formed between the axis of the planned implant and the axis of the inserted implant. Secondary outcomes included several linear deviations: crestal global deviation (distance between the coronal ends of the planned and placed implants), apical global deviation (distance between apical endpoints), vertical linear deviation (vertical displacement measured at the implant hexagon), lateral linear deviation (horizontal displacement along the implant axis), apical vertical deviation, and apical lateral deviation. Additionally, two anatomical safety measures were assessed: the distance from the implant to the inferior alveolar nerve in the mandible and to the maxillary sinus in the upper jaw.
These parameters were visualized and measured within the Blue Sky Plan 4 software. Measurement techniques adhered to rigorous digital protocols ensuring minimal human error and high reproducibility. The implant planned position was displayed in red, and the actual implant placement was marked in yellow, allowing for straightforward differentiation and measurement. Each deviation type was clearly outlined and labeled, enabling comprehensive analysis.
Once the measurements were collected, data entry and statistical analysis were conducted using SPSS version 22. Descriptive statistics summarized demographic and clinical characteristics of the sample. Central tendency measures provided insights into the distribution of deviation parameters. Inferential statistics included Independent t-tests for comparing mean deviation values between the countersink guided and fully-guided groups. When normality assumptions were not met, non-parametric equivalents were employed. Chi-square and Fisher's exact tests were applied for categorical variable comparisons. A 95% confidence interval was considered, with a p-value of less than 0.05 interpreted as statistically significant.
The primary objective was to determine whether the countersink guided technique demonstrated comparable accuracy to the fully-guided method. Accurate implant placement is critical not only for esthetic alignment and prosthetic function but also to prevent inadvertent injury to vital anatomical structures. Understanding whether a simpler countersink-guided approach can yield similar outcomes to more resource-intensive fully-guided surgery can have significant implications for clinical decision-making, cost-effectiveness, and treatment accessibility.
The findings of this study are expected to bridge the current knowledge gap by offering clinically derived data that supports or refutes the relative precision of countersink guided surgery. If the countersink technique proves nearly as accurate as fully-guided surgery, it may emerge as a reliable alternative in clinical scenarios where digital planning or guide fabrication is not feasible or practical. Conversely, significant deviations could reinforce the superiority of fully-guided approaches, especially in anatomically sensitive or esthetically demanding cases.
Ultimately, the goal of this research is to contribute to the evolving field of implantology by evaluating emerging surgical techniques through a robust, clinically relevant framework. This study offers valuable insights into surgical accuracy in implant dentistry and highlights the importance of precise preoperative planning, technique selection, and the integration of digital technologies to enhance patient outcomes and safety.
- Conditions
- Partially Edentulous Jaw, Accuracy of Dental Implant Placement, Implant Deviation and Positioning Errors, Proximity to Anatomical Structures
- Being tested
- Dental Implant
- Keywords
- Countersink guided, Quasi experimental study, fully guided, Accuracy, Partially edentulous
- Medical subject headings
- Jaw, Edentulous, Partially
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Dental ImplantOther
Dental implants were placed to volunteers in need of implantation in mandible, maxilla or both
| Study group | Role | What they receive |
|---|---|---|
| Freehand immediate implant placement | Experimental | Not described Receives: Other: Dental Implant |
| Surgery guide implant placement | Active comparator | Not described Receives: Other: Dental Implant |
What is being measured
The primary outcome is the main question the study is designed to answer.
Angular deviation
The primary outcome was angular deviation defined as the angle closed by the principal axis of the planned implant and the principal axis of the inserted implant in degrees.
Measured: 3 months
Secondary outcomes (8)
Crestal global deviation
Crestal Global Deviation: A 3D measurement of the difference between planned and actual implant positions at the bone crest. It reflects overall placement accuracy. Lower values indicate better precision.
Measured: 3 months
Apical global deviation
Apical Global Deviation: A 3D measurement of the discrepancy between planned and actual implant positions at the apex. It indicates overall accuracy at the implant tip. Lower values reflect more precise placement.
Measured: 3 months
Coronal Center Deviation
The linear distance (in millimeters) between the center of the coronal end of the planned and actual implants. It measures horizontal placement accuracy at the implant's entry point.
Measured: 3 months
Apical Endpoint Deviation and Vertical Deviation
The apical endpoint deviation measures the distance (in mm) between the tips of the planned and inserted implants. Vertical deviation refers to the difference in height between these apical points. Both assess accuracy of depth and angular positioning.
Measured: 3 months
Hexagonal Lateral Deviation
The lateral linear deviation is measured as the distance (in mm) between a perpendicular line on the planned implant's hexagon and a parallel line on the actual implant's hexagon. It reflects horizontal rotational or positional deviation
Measured: 3 months
Apical Lateral Deviation
The distance (in mm) between a vertical line along the planned implant's long axis and a parallel line through the apex of the actual implant. It reflects horizontal deviation at the apical end.
Measured: 3 months
Long Axis Lateral Deviation
The distance (in mm) between a vertical line along the long axis of the planned implant and a parallel line along the actual implant's long axis. It measures overall lateral shift of implant placement. Two anatomical parameters were also assessed alongside this measurement.
Measured: 3 months
Anatomical Safety Distances (IAN and MS)
These measurements assess the distances (in mm) from the implant apex to the inferior alveolar nerve (IAN) in the mandible and the maxillary sinus (MS) in the maxilla. They ensure safe implant placement relative to critical anatomical structures.
Measured: 3 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Jul 2025
- Study start23 Feb 2023
- Primary completion25 May 2023
- Study completion25 May 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Partially Edentulous JawStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 15 participants (actual)
Sponsor and investigators
- Lead sponsor
- Islamic University of Caza, Gaza, Palestine
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Tayseer Afifi, Islamic University of Caza, Gaza, Palestine
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07061418
- Sponsor's protocol ID
- PHRC/HC/1242/23
- Status last verified
- Jul 2025
- First submitted
- 23 Jun 2025
- Last updated
- 11 Jul 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Bell CK, Sahl EF, Kim YJ, Rice DD. Accuracy of Implants Placed with Surgical Guides: Thermoplastic Versus 3D Printed. Int J Periodontics Restorative Dent. 2018 Jan/Feb;38(1):113-119. doi: 10.11607/prd.3254.
PubMed 29240212De Angelis F, Papi P, Mencio F, Rosella D, Di Carlo S, Pompa G. Implant survival and success rates in patients with risk factors: results from a long-term retrospective study with a 10 to 18 years follow-up. Eur Rev Med Pharmacol Sci. 2017 Feb;21(3):433-437.
PubMed 28239830Derks J, Hakansson J, Wennstrom JL, Tomasi C, Larsson M, Berglundh T. Effectiveness of implant therapy analyzed in a Swedish population: early and late implant loss. J Dent Res. 2015 Mar;94(3 Suppl):44S-51S. doi: 10.1177/0022034514563077. Epub 2014 Dec 11.
PubMed 25503901Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018 Jun;45(6):721-732. doi: 10.1111/jcpe.12897. Epub 2018 May 10.
PubMed 29608793
Study at a glance
From the registry record, last updated by the sponsor on 11 Jul 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- 3D Evaluation the Accuracy of Free-Handed-Countersink Guided and Fully-Guided Implant Surgery in Partially Edentulous Patients: A Clinical Trial With Quasi-experimental Study
- ClinicalTrials.gov ID
- NCT07061418
- Acronym / sponsor ID
- PHRC/HC/1242/23
- Conditions
- Partially Edentulous Jaw, Accuracy of Dental Implant Placement, Implant Deviation and Positioning Errors, Proximity to Anatomical Structures
- Keywords
- Countersink guided, Quasi experimental study, fully guided, Accuracy, Partially edentulous
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 15 participants (actual)
- Lead sponsor
- Islamic University of Caza, Gaza, PalestineUniversity, hospital or other
- Study start
- 23 Feb 2023 (actual)
- Primary completion
- 25 May 2023 (actual)
- Study completion
- 25 May 2023 (actual)
- First posted
- 11 Jul 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This clinical trial with a quasi-experimental design investigates the accuracy of dental implant placement using three different surgical approaches: free-handed countersink guided, fully-guided, and traditional freehand techniques in partially edentulous patients. Dental implant therapy not only requires successful osseointegration but also a precise three-dimensional placement to ensure functional and esthetic outcomes. Accurate implant positioning is vital to prevent complications and ensure long-term stability. The evolution of digital technology has led to the development of computer-assisted implant surgery, enhancing surgical precision and minimizing the chances of deviation from planned positions.
In this study, implants were placed in the same patients on both sides of the jaw using two techniques for comparison - one side received a free-handed countersink guided implant, while the other used a fully-guided surgical guide. Patients included in this research were partially dentate adults with adequate oral health, bone volume, and no systemic conditions or habits that could interfere with healing. Pre-operative and post-operative cone-beam computed tomography (CBCT) scans were used to evaluate the positional accuracy of the implants.
The three-dimensional evaluation method utilized Blue Sky Plan 4 and 3D Slicer software to superimpose and analyze implant placements. Parameters such as angular deviation, crestal global deviation, apical global deviation, vertical linear deviation, lateral linear deviation, apical vertical deviation, apical lateral deviation, and distances from anatomical structures like the inferior alveolar nerve and the maxillary sinus were measured to assess placement accuracy. Measurements were taken using automatic image registration and STL superimposition of planned versus actual implant locations.
Data collected was analyzed using SPSS software. Both descriptive and inferential statistical analyses were conducted. The results aimed to determine the accuracy differences between countersink-guided and fully-guided implant techniques. The findings of this study contribute to evidence-based clinical decisions in implant dentistry by exploring if countersink-guided approaches offer comparable accuracy to fully-guided methods, thus supporting safer and more effective dental implant procedures in clinical practice.
Detailed description
This clinical trial with a quasi-experimental study design explores the comparative accuracy of dental implant placement using three different surgical protocols in partially edentulous patients: free-handed countersink guided, fully-guided, and traditional freehand methods. The precision of implant positioning plays a pivotal role in the long-term success and aesthetics of dental implant therapy. Although osseointegration is fundamental, optimal functional and esthetic outcomes are contingent upon the precise three-dimensional positioning of the implant within the jawbone. The rationale behind this study stems from the clinical observation that improper implant placement can result in technical and biological complications, leading to treatment failure or compromised prosthetic outcomes.
The advent of digital imaging and surgical planning has revolutionized implant dentistry. Traditional radiographic stents and manual implant placement methods have been increasingly replaced by static computer-assisted implant surgery (s-CAIS), allowing for improved preoperative visualization and enhanced implant positioning accuracy. In the digital workflow, combining intraoral scans with cone-beam computed tomography (CBCT) enables clinicians to plan implant positions based on bone quality, soft tissue contours, and the spatial relationship with adjacent teeth or anatomical landmarks.
Despite these advancements, there remains a lack of clinical evidence on the performance of countersink guided protocols specifically. Countersink guided placement involves using drills designed to widen the crestal cortical bone, especially in cases of dense bone, facilitating a passive fit of the implant at the neck. This approach is typically categorized under the freehand technique but is believed to offer enhanced stability during insertion. Fully-guided surgery, in contrast, utilizes a prefabricated guide that controls each step of the drilling and implant placement process, theoretically minimizing deviation.
The study involved the recruitment of partially dentate adults who fulfilled strict inclusion criteria such as having at least six remaining teeth, good oral hygiene, sufficient bone volume for implant placement without the need for grafting, and the ability to maintain mouth opening of at least 40 mm. Patients with parafunctional habits, heavy smoking, psychiatric or systemic conditions that contraindicate implant surgery, a history of radiotherapy in the head and neck region, or younger than 18 years of age were excluded.
Each patient received two implants-one placed with the countersink guided freehand method, and the other placed using a fully-guided surgical protocol. Both procedures were performed by the same surgeon using a parallel surgical kit (Dentsply®, MIS, M4, Germany), ensuring consistency in technique and instrumentation. The implants were placed on the same day and with identical preoperative planning to eliminate inter-operator and time-related variability.
To evaluate the accuracy of implant placement, preoperative CBCT scans were taken to plan the implant location, followed by postoperative CBCT scans after implant insertion. Digital planning and analysis were conducted using Blue Sky Plan 4 software and the 3D Slicer platform. Postoperative CBCT data was processed and segmented to extract the STL file of the actual implant placement. These files were then superimposed onto the original preoperative plan using point-based automatic registration. More than twenty anatomical and reference points were marked to ensure a precise overlay, enabling a direct comparison of the actual and planned implant positions in three-dimensional space.
The primary outcome of interest was angular deviation-the angle formed between the axis of the planned implant and the axis of the inserted implant. Secondary outcomes included several linear deviations: crestal global deviation (distance between the coronal ends of the planned and placed implants), apical global deviation (distance between apical endpoints), vertical linear deviation (vertical displacement measured at the implant hexagon), lateral linear deviation (horizontal displacement along the implant axis), apical vertical deviation, and apical lateral deviation. Additionally, two anatomical safety measures were assessed: the distance from the implant to the inferior alveolar nerve in the mandible and to the maxillary sinus in the upper jaw.
These parameters were visualized and measured within the Blue Sky Plan 4 software. Measurement techniques adhered to rigorous digital protocols ensuring minimal human error and high reproducibility. The implant planned position was displayed in red, and the actual implant placement was marked in yellow, allowing for straightforward differentiation and measurement. Each deviation type was clearly outlined and labeled, enabling comprehensive analysis.
Once the measurements were collected, data entry and statistical analysis were conducted using SPSS version 22. Descriptive statistics summarized demographic and clinical characteristics of the sample. Central tendency measures provided insights into the distribution of deviation parameters. Inferential statistics included Independent t-tests for comparing mean deviation values between the countersink guided and fully-guided groups. When normality assumptions were not met, non-parametric equivalents were employed. Chi-square and Fisher's exact tests were applied for categorical variable comparisons. A 95% confidence interval was considered, with a p-value of less than 0.05 interpreted as statistically significant.
The primary objective was to determine whether the countersink guided technique demonstrated comparable accuracy to the fully-guided method. Accurate implant placement is critical not only for esthetic alignment and prosthetic function but also to prevent inadvertent injury to vital anatomical structures. Understanding whether a simpler countersink-guided approach can yield similar outcomes to more resource-intensive fully-guided surgery can have significant implications for clinical decision-making, cost-effectiveness, and treatment accessibility.
The findings of this study are expected to bridge the current knowledge gap by offering clinically derived data that supports or refutes the relative precision of countersink guided surgery. If the countersink technique proves nearly as accurate as fully-guided surgery, it may emerge as a reliable alternative in clinical scenarios where digital planning or guide fabrication is not feasible or practical. Conversely, significant deviations could reinforce the superiority of fully-guided approaches, especially in anatomically sensitive or esthetically demanding cases.
Ultimately, the goal of this research is to contribute to the evolving field of implantology by evaluating emerging surgical techniques through a robust, clinically relevant framework. This study offers valuable insights into surgical accuracy in implant dentistry and highlights the importance of precise preoperative planning, technique selection, and the integration of digital technologies to enhance patient outcomes and safety.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Freehand immediate implant placement | Experimental | Other: Dental Implant |
| Surgery guide implant placement | Active comparator | Other: Dental Implant |
Who may qualify
- Ages
- 18 to 53 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (8 listed)
- Partially dentate adults with at least 6 remaining teeth
Key exclusion criteria (4 listed)
- Heavy smoking
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Dental ImplantDental implants were placed to volunteers in need of implantation in mandible, maxilla or both | Other | Freehand immediate implant placement, Surgery guide implant placement |
Primary outcome
Angular deviation
Time frame: 3 months
The primary outcome was angular deviation defined as the angle closed by the principal axis of the planned implant and the principal axis of the inserted implant in degrees.
8 secondary outcomes
Crestal global deviation
Time frame: 3 months
Apical global deviation
Time frame: 3 months
Coronal Center Deviation
Time frame: 3 months
Apical Endpoint Deviation and Vertical Deviation
Time frame: 3 months
Hexagonal Lateral Deviation
Time frame: 3 months
Apical Lateral Deviation
Time frame: 3 months
Long Axis Lateral Deviation
Time frame: 3 months
Anatomical Safety Distances (IAN and MS)
Time frame: 3 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 11 Jul 2025.
- Results publication: PubMed 29240212Bell CK, Sahl EF, Kim YJ, Rice DD. Accuracy of Implants Placed with Surgical Guides: Thermoplastic Versus 3D Printed. Int J Periodontics Restorative Dent. 2018 Jan/Feb;38(1):113-119. doi: 10.11607/prd.3254.
- Results publication: PubMed 28239830De Angelis F, Papi P, Mencio F, Rosella D, Di Carlo S, Pompa G. Implant survival and success rates in patients with risk factors: results from a long-term retrospective study with a 10 to 18 years follow-up. Eur Rev Med Pharmacol Sci. 2017 Feb;21(3):433-437.
- Results publication: PubMed 25503901Derks J, Hakansson J, Wennstrom JL, Tomasi C, Larsson M, Berglundh T. Effectiveness of implant therapy analyzed in a Swedish population: early and late implant loss. J Dent Res. 2015 Mar;94(3 Suppl):44S-51S. doi: 10.1177/0022034514563077. Epub 2014 Dec 11.
- Results publication: PubMed 29608793Younes F, Cosyn J, De Bruyckere T, Cleymaet R, Bouckaert E, Eghbali A. A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients. J Clin Periodontol. 2018 Jun;45(6):721-732. doi: 10.1111/jcpe.12897. Epub 2018 May 10.
- Individual participant dataSharing planned: No
Related trials for Partially Edentulous Jaw
Active, not recruiting
L-PRF Block vs Composite Graft for Horizontal Ridge Augmentation
Alveolar Ridge Resorption After Extraction, Alveolar Bone Loss
Not yet recruitingObservational study
Digital and Conventional Clasp-retained Partial Dentures (DIGICLASP)
Partial Edentulism
Active, not recruiting
Multicenter Study to Evaluate the Clinical Outcome of PrimeTaper EV Implant in Single Tooth Restorations
Jaw, Edentulous, Partially
Recruiting
Clinical and Radiographic Evaluation of UV-Treated Dental Implants With or Without Melatonin in the Upper Posterior Jaw
Jaw, Edentulous, Partially, Bone Resorption
Active, not recruiting
A Clinical Study on Acuris™ - Conometric Concept for Single Tooth Restoration
Jaw, Edentulous, Partially
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Dental Implant in people with Partially Edentulous Jaw and Accuracy of Dental Implant Placement, run by Islamic University of Caza, Gaza, Palestine at 1 site in Palestinian Territories.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 11 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Palestinian Territories. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Angular deviation (time frame: 3 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07061418, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Jul 2025.