Primary Percutaneous Coronary InterventionNCT06914089

Thin Versus Thicker Strut Thickness Stents in Primary Percutaneous Intervention

A study testing The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edges in people with Primary Percutaneous Coronary Intervention, run by Assiut University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

1. To evaluate clinical safety of the device in terms of Deaths, any stroke and Myocardial Infarction up to 1 year in both study groups to prove non inferiority of biomime stent 2. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
What is being tested?
The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edges
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
146 participants
Where
1 siteEgypt
Study dates
1 Oct 2020to 30 Sep 2023
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • •All patients with ST-segment elevation myocardial infarction and diagnosed according to the last guidelines.

Who cannot join

  • Left ventricular ejection fraction ≤30%.
  • Killip class III or IV at presentation.
  • Extreme vessel tortuosity or lesion angulation (˂45˚).
  • Severe calcification proximal to or within the target lesion.
  • Bifurcation lesions with side branch diameter >2 mm.
  • Mechanical complication of STEMI.
  • Severe comorbidity such as malignancy

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Assiut

    Asyut, Alsabeel, 71515

Other trials in Egypt

About this study

Official title: Short and Long-term Outcomes of Biodegradable Coated Stent (Biomime Versus Ultimaster) Deployed in STEMI Patients Undergoing Primary Percutaneous Intervention

  1. To evaluate clinical safety of the device in terms of Deaths, any stroke and Myocardial Infarction up to 1 year in both study groups to prove non inferiority of biomime stent
  2. To evaluate presence of Target lesion and target vessel revascularization in in both study groups prove non inferiority of biomime stent
  3. To evaluate target vessel non-target lesion revasularization in both study groups prove non inferiority of biomime stent
Read the detailed description
  • Drug-eluting stents (DES) represent a key advance in percutaneous coronary interventions (PCI) owing to their ability to inhibit neointimal proliferation, which lowers the need for repeat revascularisation However, older-generation DES have been shown to increase the risk of late restenosis and stent thrombosis. Efforts to reduce these risks include improvements in stent platforms, polymer carriers, and drug selection. Thinner struts reduce vessel wall injury, decrease inflammation and promote fast endothelialisation.The second-generation thin-strut DES have been shown to reduce the risk of restenosis, stent thrombosis and myocardial infarction (MI) or possibly death when compared with older-generation DES or bare metal stents. Moreover, the newer generation of biodegradable polymer stents has the potential to reduce the inflammatory reaction of the arterial wall and minimise the risk of late restenosis and thrombus formation More recently, ultra-thin (<70 μm) DES have been shown to improve outcomes further compared with second-generation DES.The BioMime™ (Meril Life Sciences Pvt. Ltd., Vapi, India) is an ultra-thin sirolimus-eluting coronary stent (SES) with an established preliminary safety and efficacy record in the previous meriT-1, meriT-2, meriT-3 and meriT-4 trials in treating single de novo and complex lesions.The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edges which lead to Lesser Edge Dissections during expansion and Adequate Side Branch Access, coated with biocompatible and bioabsorbable polymers, PLLA (poly-L-lactic acid) and PLGA (poly-lactic-co-glycolic acid) for Faster Healing
Being tested
The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edges
Keywords
primary percutaneous coronary intervention, ultrathin stents

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edgesDevice

    testing its safety and efficacy at long term follow up after primary percutaneous intervention

Study groups in NCT06914089
Study groupRoleWhat they receive
bio mime armActive comparatorultrathin stent arm
Receives: Device: The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edges
Ultimaster armActive comparatorThe Ultimaster® (Terumo CorporationTokyo, Japan) consists of the Kaname stent platform, abluminally coated with poly D,L-lactic acid-polycaprolactone (PDLLA-PCL) as a carrier of the immunosuppressant drug sirolimus (3.9 μg/mm stent length). The purpose of the gradient coating is to reduce potential cracking and delamination of the polymer. The drug release profile allows an initial stronger release immediately following stent implantation. Then the drug is released continuously until the polymer bioabsorption is completed within three to four months. For a stent size of 3.0×15 mm, the median maximum concentration (Cmax) was 36.8 pg/mL (range between 22.9 and 41.5 pg/mL), according to the previously published detailed information on the pharmacokinetic profile
Receives: Device: The BioMime is an ultra-thin strut (65 µm) SES that uses a cobalt-chromium platform with a unique hybrid design of open cells in the mid segment and closed cells at the edges

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Target vessel failure

    Target vessel failure (TVF): defined as cardiac death that cannot be clearly attributed to a vessel other than the target vessel, target vessel MI, and clinically driven target vessel revascularization

    Measured: From enrollment and followed up for one year

  2. MACE

    Major adverse cardiac events (MACE) as a composite of cardiac death, any MI and clinically driven target vessel revascularization (CD-TVR)

    Measured: From enrollment and followed up for one year

  3. Late lumen Loss

    Late lumen loss: the difference between the minimal luminal diameter (MLD) after stent implantation and after at least 9 months post procedure

    Measured: From enrollment and followed up for one year

Secondary outcomes (3)
  1. Device-oriented composite end points

    Device-oriented composite end points (DOCE): Defined as Cardiovascular death, MI (not clearly attributable to a non-target vessel) and TLR (clinically driven)

    Measured: From enrollment and followed up for one year

  2. Patient-oriented composite end points

    Patient-oriented composite end points (POCE): Defined as all-cause mortality, any stroke, Any MI (includes non-target vessel territory) and Any revascularization

    Measured: From enrollment and followed up for one year

  3. stent thrombosis

    Definite stent thrombosis: The presence of a thrombus that originates in the stent or in the segment 5 mm proximal or distal to the stent or in a side branch originating from the stented segment and the presence of at least one of the following criteria:

    1. Acute onset of ischemic symptoms at rest B) New electrocardiographic changes suggestive of acute ischemia C) Typical rise and fall in cardiac biomarkers (refer to definition of spontaneous myocardial infarction).

    Probable stent thrombosis Regardless of the time after the index procedure, any myocardial infarction that is related to documented acute ischemia in the territory of the implanted stent without angiographic confirmation of stent/scaffold thrombosis and in the absence of any other obvious cause.

    Timing of ST (duration after stent implantation) Acute: 0-24 h \& Sub-acute >24 h-30 d \& Late >30 d-1 y \& Very late >1 y

    Measured: From enrollment and followed up for one year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Apr 2025
  2. Study start1 Oct 2020
  3. Primary completion30 Sep 2022
  4. Study completion30 Sep 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
146 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06914089
Sponsor's protocol ID
Thin strut stents
Status last verified
Mar 2025
First submitted
31 Mar 2025
Last updated
8 Apr 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Valdes-Chavarri M, Kedev S, Neskovic AN, Moris de la Tassa C, Zivkovic M, Trillo Nouche R, Vazquez Gonzalez N, Bartorelli AL, Antoniucci D, Tamburino C, Colombo A, Abizaid AA, McFadden E, Garcia-Garcia HM, Milasinovic D, Stankovic G. Randomised evaluation of a novel biodegradable polymer-based sirolimus-eluting stent in ST-segment elevation myocardial infarction: the MASTER study. EuroIntervention. 2019 Apr 5;14(18):e1836-e1842. doi: 10.4244/EIJ-D-17-01087.

    PubMed 29957593
  • Bangalore S, Toklu B, Patel N, Feit F, Stone GW. Newer-Generation Ultrathin Strut Drug-Eluting Stents Versus Older Second-Generation Thicker Strut Drug-Eluting Stents for Coronary Artery Disease. Circulation. 2018 Nov 13;138(20):2216-2226. doi: 10.1161/CIRCULATIONAHA.118.034456.

    PubMed 29945934
  • Poder TG, Erraji J, Coulibaly LP, Koffi K. Percutaneous coronary intervention with second-generation drug-eluting stent versus bare-metal stent: Systematic review and cost-benefit analysis. PLoS One. 2017 May 12;12(5):e0177476. doi: 10.1371/journal.pone.0177476. eCollection 2017.

    PubMed 28498849
  • Abizaid A, Kedev S, Kedhi E, Talwar S, Erglis A, Hlinomaz O, Masotti M, Fath-Ordoubadi F, Lemos PA, Milewski K, Botelho R, Costa R, Bangalore S. Randomised comparison of a biodegradable polymer ultra-thin sirolimus-eluting stent versus a durable polymer everolimus-eluting stent in patients with de novo native coronary artery lesions: the meriT-V trial. EuroIntervention. 2018 Dec 7;14(11):e1207-e1214. doi: 10.4244/EIJ-D-18-00762.

    PubMed 30222120