ObesityES-LCCE-UDFMNCT06862479
Luso-Cor Stent Compared to Other Endoscopic Techniques for Management of Fistulas and Anastomotic Dehiscences(ES-LCCE-UDFM)
An observational study of Obesity and Obesity, Morbid, run by Unidade Local de Saúde Santa Maria at 1 site in Portugal.
Trial summary
The global prevalence of obesity has prompted an increase in bariatric surgery, which is the only management strategy that provides long-term weight loss and improvement of obesity-related diseases. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Obesity, Obesity, Morbid, Esophageal Cancer
- What is being tested?
- Endoscopic management of fistulas with stents or vacum therapy
- Type of treatment
- Surgery or procedure
- How many people
- 180 participants
- Where
- 1 sitePortugal
- Study dates
- 1 Jan 2025to 1 Jan 2030
- How long will I take part?
- 1 Year
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients who develop fistulas or anastomotic dehiscences after oncologic surgery on the stomach or esophagus or after bariatric surgery.
Who may be able to join
- Patients undergoing endoscopic management of fistulas after bariatric surgery or dehiscences of esophago-jejunal or gastro-jejunal anastomosis after esophageal or gastric oncologic surgery will be included in the study.
Who cannot join
- Pregnancy
- Age < 18years
- Inability to give informed consent.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Portugal1 site
Serviço de Gastrenterologia e Hepatologia, Unidade Local de Saúde Santa Maria
Lisbon, Lisbon District, 1649-035
About this study
Official title: Efficacy and Safety of the Luso-Cor Esophageal Stent Compared to Other Endoscopic Techniques in the Management of Fistulas and Anastomotic Dehiscences After Upper Digestive Tract Surgery (ES-LCCE-UDFM)
The global prevalence of obesity has prompted an increase in bariatric surgery, which is the only management strategy that provides long-term weight loss and improvement of obesity-related diseases. Bariatric surgeries include sleeve gastrectomy(SG), Roux-en-Y gastric bypass(RYGB),and laparoscopically adjustable gastric banding(LAGB). The incidence of adverse events depends on the type of bariatric surgery performed, with serious adverse events occurring in approximately 4% and mortality in 0.1% patients. The incidence of fistulas after SG varies between 0.2% to 2.5% and between 1% and 4.9% in patients who have undergone an RYGB. The incidence of strictures after SG is approximately 0.35%. Older, more obese, and male patients with multiple comorbidities related to obesity are at increased risk for the development of fistulas and mortality following bariatric surgery. Additionally, surgery after LAGB increases the risk of adverse events.
This study will compare the efficacy and safety of the Luso-Cor esophageal stent versus conventional covered metallic stents versus endoscopic vacuum therapy in the management of fistulas and anastomotic dehiscences after oncologic or bariatric surgery on the stomach and esophagus.
Read the detailed description
The morbidity and mortality related to adverse events increases with surgical re-exploration at the site of a fistula orifice. For this reason, management of fistulas after bariatric surgery has shifted from a surgical to a primarily endoscopic approach, primarily with covered metallic stents, with fistula closure success rates between 75% and 100%. However, a primarily endoscopic approach is demanding in terms of resource use, and the high incidence of stent migration often requires multiple reinterventions - both endoscopically and surgically.
The Luso-Cor esophageal stent was designed to take into account altered anatomy after bariatric surgery and to overcome strictures in the gastric tube, which can be concomitantly present in patients with fistulas following SG. A pilot study involving 15 patients with fistulas after sleeve gastrectomy managed with the Luso-Cor esophageal stent showed a 100% rate of fistula closure, low rate of adverse events with only one episode of stent dysfunction.
A recent meta-analysis suggested that endoscopic vacuum therapy (EVT) was associated with a 21% increase in successful fistula closure compared to self expanding metallic stents (RD 0.21, CI 0.10-0.32; P = 0.0003), a 12% reduction in mortality compared to stenting (RD 0.12, CI 0.03-0.21; P = 0.006) and an average reduction of 14.22 days in duration of treatment (CI 8.38-20.07; P < 0.00001). Additionally, EVT was associated with a 24% reduction in adverse events (RD 0.24, CI 0.13-0.35; P = 0.0001. There were no statistical differences between the studied therapies regarding the length of hospital stay.
Therefore, this study aims to evaluate and compare the success of the novel Luso-Cor esophageal stent in the exclusion of fistulas, reinterventions, stent-related adverse events, duration of hospitalization and its efficacy in the management of fistulas after SG compared to other stents or EVT.
Hypothesis of the study The novel concept of esophageal anchoring of a specially designed long stent may be useful in management of fistulas after gastric surgery with high success rate and minimal morbidity compared to conventionally available esophageal or bariatric surgery stents and EVT.
Objectives of the study
To evaluate and compare the performance of the Luso-Cor oesophageal stent with other stents or EVT in management of fistulas after bariatric and oncologic surgery on the upper digestive tract with regard to:
- Technical success defined as successful deployment of the stent at the desired location and exclusion of the fistula orifice.
- Clinical efficacy defined as successful closure of the fistula orifice after stent removal.
- Safety - Early and late adverse events related to stent placement.
- Duration of hospitalization
- Number of endoscopic procedures required till fistula closure
- Mortality
Inclusion criteria Patients undergoing endoscopic management of fistulas after bariatric surgery or dehiscences of esophago-jejunal, esophago-gastric or gastro-jejunal anastomosis after esophageal or gastric oncologic surgery will be included in the study.
Exclusion criteria
- Pregnancy
- Age < 18years
- Inability to give informed consent.
Type of study: Prospective observational multicentre study.
Materials and methods Conventional covered metallic and bariatric surgery stents and EVT will be used as per standard of care.
Design features of the Luso-Cor esophageal stent: This is a specifically designed stent to manage fistulas after sleeve gastrectomy, Roux-en-Y gastric bypass and esophago-jejunal anastomotic dehiscences after total gastrectomy. This metallic stent measuring 24 cm in length is covered with silicone and has three sections: 1) A proximal flared portion with diameters of 30, 34 and 36 mm measuring 6 cm in length; 2) Middle narrow portion with a fixed diameter of 20 mm measuring 16 cm in length; and 3) Distal flared portion with a fixed diameter of 30 mm measuring 2 cm in length.
Esophageal anchoring, is achieved through the larger diameter of the proximal flared portion compared to conventional stents and a 5 mm uncovered portion located 1 cm below the proximal edge of the stent. The remainder of the stent is covered with a thin silicone coating. This contrasts with the conventional partially covered metallic esophageal stents which usually have at least 1 cm of uncovered portions near the proximal and distal edges.
There are two zones within the middle narrowed portion of the stent which allow articulation of the stent on itself up to 90º. This allows the stent to adapt to altered anatomy and peristaltic activity of the foregut. The distal flared portion of the stent is designed to be placed in the gastric antrum or in the proximal jejunum, to avoid peri-stent reflux of enteric fluid.
Radio-opaque markers are placed at the proximal and distal edge of the stent and at the junction of the proximal flared portion with the middle narrow portion, unlike conventional metallic esophageal where the radio-opaque markers are placed at the stent edges and in the middle.
Stent placement: Placement of the stent is done by over the wire technique and ideally with X-ray imaging control. It can also be done with endoscopic control by the bedside in emergencies. The distal edge of the stent should be placed at least 2 cm proximal to the pylorus and the proximal flared portion should be placed in the distal esophagus, at least 2 cm above the esophago-gastric junction or esophago-jejunal anastomosis. During stent delivery, after verifying opening of the distal flare of the stent near the pylorus, the endoscopist should focus on the radio-opaque markers in the proximal portion of the stent which are separated by 6 cm so that the proximal flare is liberated in the distal third of the esophagus.
Due to the usually smaller diameter of the esophagus in women, we recommend the use of the Luso-Cor esophageal stent with proximal flare of 30 mm diameter in women and 34 and 36 mm diameters in men. However, the endoscopist should choose the ideal diameter based on the endoscopic assessment of the esophageal lumen diameter prior to stent placement.
After deployment, the stent should be kept in place for at least 4 weeks and up to a maximum of 12 weeks. An oral contrast study should be done 48 to 72 hoursafter stent deployment to confirm effective exclusion of fistula orifice after which oral dietary intake may be commenced. All patients should receive proton pump inhibitors (PPIs) twice a day with a recommendation for head elevation in the supine position to decrease reflux esophagitis.
Stent Removal: Stent removal is easy compared to conventional stents. It requires ablation of the mucosal ingrowth in the 5mm uncovered portion near the proximal edge of the stent with argon plasma 50W/1L, followed by scraping of the tissue with a cap applied at the tip of the endoscope and capture of the drawstring at the proximal edge of the stent with a rat tooth forceps.
Clinical data and management strategy of patients with fistulas or anastomotic dehiscences:
The type of stent used or option for use of EVT as first line endoscopic option will be at the discretion of the endoscopist.
The Luso-Cor esophageal stent was approved for clinical use in Portugal in 2016 by regulatory authorities (INFARMED).
After diagnosis of fistulas, whenever required, patients should undergo surgical peritoneal toillete either by laparotomy or laparoscopy with placement of abdominal drains.
Informed consent for endoscopic procedures to manage fistulas or anastomotic dehiscences will be obtained from all patients.
The location and size of the fistula orifice will be determined and the presence of concomitant stricture of the gastric tube noted endoscopically.
Fistulas will be considered as acute if endoscopy was performed within one month of surgery and chronic if performed >1 month after surgery.
Whenever possible, the fistula orifice will be closed with either through the scope clips(TTSCs) or the over the scope clips(OTSCs). Small fistula orifices measuring <5 mm will be initially managed with either TTSCs or OTSCs.
The Luso-Cor esophageal stent may be used as the first option in patients with fistula orifices >5 mm either alone or in combination with OTSCs or TTSCs, in those patients who have fistula persistence after initial application of TTSCs or OTSCs or in those with concomitant stricture in the gastric tube detected endoscopically.
Gastroesophageal reflux disease after stent placement will be managed with double dose PPI and sucralfate 1g up to 4 times a day.
Definitions Technical success will be defined as correct placement and coaptation of the stent at the previously planned location under fluoroscopic imaging with radio-opaque markers with effective exclusion of fistula orifice.
Clinical efficacy will be defined as closure of the fistula orifice after Luso-Cor esophageal stent removal. Definitive closure of the fistula orifice should be confirmed by contrast injection during endoscopy and / or oral contrast study after Luso-Cor esophageal stent removal.
A secondary endpoint of clinical efficacy will be the effectiveness of the Luso-Cor esophageal stent or other stents in managing fistulas in the gastric tube after vertical gastrectomy.
Stent related adverse events will be defined as early (within 1 week of stent placement) and late (> 1 week after stent placement) and include stent migration, perforation, hemorrhage, stent fracture and mortality.
Primary outcome for this study will be closure of the fistula orifice after stent removal. Secondary outcomes will be effectiveness of the stent in managing strictures in the gastric tube, stent-related adverse events, number of endoscopies, motives for endoscopic reinterventions and the number of stents used, duration of hospitalization and fistula or stent-related mortality.
Simple fistulas will be defined as fistulas communicating between a hollow organ and the peritoneum or pleura (Gastro-pleural or gastro-peritoneal).
Complex fistulas will be defined as fistulas communicating between two hollow organs (Gastro-bronquial) or between a hollow organ and the skin (Gastro-cutaneous) or those with sub-divisions and multiple trajectories in continuity with a fistula orifice.
All procedures will be performed in accordance with the ethical standards of the institution and with the 1964 Helsinki declaration.
Statistical Analysis Qualitative data will be presented as percentages and quantitative data as median (Min-Max). Factors at baseline predicting technical success, clinical success, clinical efficacy and development of adverse events will be evaluated using the Logistic regression analysis.
Qualitative data will be compared with the Chi-square test and quantitative data will be compared with the Student´s t test or Mann-Whitney test if the distribution is normal or non-normal.
Multivariate analysis will take into account all factors at baseline associated with the outcomes measured (p<0,1) and will be performed using the backward stepwise regression.
A p value <0,05 will be considered statistically significant. Data will be analyzed using IBM SPSS 21 (SPSS Inc., Chicago, IL, USA).
- Conditions
- Obesity, Obesity, Morbid, Esophageal Cancer, Esophageal Neoplasms, Gastric Cancer, Gastric Adenocarcinoma
- Being tested
- Endoscopic management of fistulas with stents or vacum therapy
- Keywords
- Fistulas, Anastomotic dehiscences, Endoscopic management, Stents, Endoscopic vacuum therapy
- Medical subject headings
- Obesity, Obesity, Morbid, Esophageal Neoplasms, Stomach Neoplasms, Fistula, Anastomotic Leak
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Endoscopic management of fistulas with stents or vacum therapyProcedure or surgery
A prospective registry of patients who develop fistulas after oncologic surgery on the stomach or esophagus as well as those after bariatric surgery and managed endoscopically with stents or endoscopic vacuum therapy will be evaluated to assess and compare the efficacy and safety of the Luso-Cor versus conventional partially or fully covered metallic stents or bariatric stents or endoscopic vacuum therapy.
| Study group | Role | What they receive |
|---|---|---|
| Fistulas after oncologic or bariatric surgery on the stomach or esophagus | Patients who develop fistulas after oncologic surgery on the stomach or esophagus or those patients who develop fistulas after bariatric surgery (Vertical or sleeve gastrectomy or gastric bypass) managed endoscopically with endoscopic vacuum therapy group. Receives: Procedure: Endoscopic management of fistulas with stents or vacum therapy |
What is being measured
The primary outcome is the main question the study is designed to answer.
Compare the efficacy of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery in terms of fistula closure.
To evaluate and compare the performance of the Luso-Cor oesophageal stent with other stents or EVT in management of fistulas after bariatric and oncologic surgery on the upper digestive tract with regard to fistula closure rate expressed as percentage
Measured: 36 months for recruitment of 180 patients.
Compare the safety of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery in terms of rate of adverse events
To evaluate and compare the safety of the Luso-Cor oesophageal stent with other stents or EVT in management of fistulas after bariatric and oncologic surgery on the upper digestive tract with regard to early and late adverse event rate expressed as percentage.
Measured: 36 months for recruitment of 180 patients.
Secondary outcomes (4)
Compare the technical success of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery
Technical success is defined as successful deployment of the stent at the desired location and exclusion of the fistula orifice and will be expressed as percentage.
Measured: 36 months for recruitment of 180 patients.
Compare duration of hospitalization in patients developing fistulas after oncologic surgery on the stomach and esophagus or bariatric surgery managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy.
Compare the duration of hospitalization in patients who developed fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in weeks expressed as median (min-max).
Measured: 36 months for recruitment of 180 patients.
Compare the number of endoscopies till fistula closure in patients managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy who developed fistulas after oncologic surgery on the stomach and esophagus or bariatric surgery.
Compare the number of endoscopic procedures required till fistula closure in patients managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy who developed fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery expressed as median (min - max)
Measured: 36 months for recruitment of 180 patients.
Compare the mortality in patients who developed fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery, managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy.
Compare the mortality in patients who developed fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery, managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy expressed as a percentage.
Measured: 36 months for recruitment of 180 patients.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Mar 2025
- Study start1 Jan 2025
- Primary completion1 Jan 2028 (estimated)
- Study completion1 Jan 2030 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (17)Papers the sponsor has linked to this study.
- Other trials for ObesityStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Other
- Time perspective
- Prospective
- Enrolment
- 180 participants (estimated)
- Target duration
- 1 Year
Sponsor and investigators
- Lead sponsor
- Unidade Local de Saúde Santa Maria
- Sponsor type
- Other government
- Responsible party
- Principal investigator, Carlos Noronha Ferreira, Unidade Local de Saúde Santa Maria
- Investigators
- Carlos Noronha Ferreira, MD, MSc, PhD, Principal investigator, Serviço de Gastrenterologia e Hepatologia, Unidade Local de Saúde Santa Maria
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06862479
- Sponsor's protocol ID
- 001
- Acronym
- ES-LCCE-UDFM
- Status last verified
- May 2026
- First submitted
- 18 Feb 2025
- Last updated
- 6 May 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: This is an investigator driven study which aims to evaluate and compare efficacy of the Luso-Cor esophageal stent versus conventional covered stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery
Publications
do Monte Junior ES, de Moura DTH, Ribeiro IB, Hathorn KE, Farias GFA, Turiani CV, Medeiros FS, Bernardo WM, de Moura EGH. Endoscopic vacuum therapy versus endoscopic stenting for upper gastrointestinal transmural defects: Systematic review and meta-analysis. Dig Endosc. 2021 Sep;33(6):892-902. doi: 10.1111/den.13813. Epub 2020 Oct 28.
PubMed 33300634Clinical Efficacy and Safety of a Novel Stent for Fistula Management Following Sleeve Gastrectomy Noronha Ferreira, Carlos et al. Techniques and Innovations in Gastrointestinal Endoscopy, Volume 26, Issue 1, 12 - 20
Eisendrath P, Cremer M, Himpens J, Cadiere GB, Le Moine O, Deviere J. Endotherapy including temporary stenting of fistulas of the upper gastrointestinal tract after laparoscopic bariatric surgery. Endoscopy. 2007 Jul;39(7):625-30. doi: 10.1055/s-2007-966533.
PubMed 17611917Kanters AE, Shubeck SP, Varban OA, Dimick JB, Telem DA. Incidence and Efficacy of Stent Placement in Leak Management After Bariatric Surgery: An MBSAQIP Analysis. Ann Surg. 2020 Jan;271(1):134-139. doi: 10.1097/SLA.0000000000003023.
PubMed 30247333Swinnen J, Eisendrath P, Rigaux J, Kahegeshe L, Lemmers A, Le Moine O, Deviere J. Self-expandable metal stents for the treatment of benign upper GI leaks and perforations. Gastrointest Endosc. 2011 May;73(5):890-9. doi: 10.1016/j.gie.2010.12.019.
PubMed 21521563Bege T, Emungania O, Vitton V, Ah-Soune P, Nocca D, Noel P, Bradjanian S, Berdah SV, Brunet C, Grimaud JC, Barthet M. An endoscopic strategy for management of anastomotic complications from bariatric surgery: a prospective study. Gastrointest Endosc. 2011 Feb;73(2):238-44. doi: 10.1016/j.gie.2010.10.010.
PubMed 21295637Eubanks S, Edwards CA, Fearing NM, Ramaswamy A, de la Torre RA, Thaler KJ, Miedema BW, Scott JS. Use of endoscopic stents to treat anastomotic complications after bariatric surgery. J Am Coll Surg. 2008 May;206(5):935-8; discussion 938-9. doi: 10.1016/j.jamcollsurg.2008.02.016.
PubMed 18471727Puli SR, Spofford IS, Thompson CC. Use of self-expandable stents in the treatment of bariatric surgery leaks: a systematic review and meta-analysis. Gastrointest Endosc. 2012 Feb;75(2):287-93. doi: 10.1016/j.gie.2011.09.010. Epub 2011 Nov 1.
PubMed 22047699Fernandez AZ Jr, DeMaria EJ, Tichansky DS, Kellum JM, Wolfe LG, Meador J, Sugerman HJ. Experience with over 3,000 open and laparoscopic bariatric procedures: multivariate analysis of factors related to leak and resultant mortality. Surg Endosc. 2004 Feb;18(2):193-7. doi: 10.1007/s00464-003-8926-y. Epub 2003 Dec 29.
PubMed 14691697van Wezenbeek MR, de Milliano MM, Nienhuijs SW, Friederich P, Gilissen LP. A Specifically Designed Stent for Anastomotic Leaks after Bariatric Surgery: Experiences in a Tertiary Referral Hospital. Obes Surg. 2016 Aug;26(8):1875-80. doi: 10.1007/s11695-015-2027-6.
PubMed 26699374Ballesta C, Berindoague R, Cabrera M, Palau M, Gonzales M. Management of anastomotic leaks after laparoscopic Roux-en-Y gastric bypass. Obes Surg. 2008 Jun;18(6):623-30. doi: 10.1007/s11695-007-9297-6. Epub 2008 Apr 8.
PubMed 18392906Rosenthal RJ; International Sleeve Gastrectomy Expert Panel; Diaz AA, Arvidsson D, Baker RS, Basso N, Bellanger D, Boza C, El Mourad H, France M, Gagner M, Galvao-Neto M, Higa KD, Himpens J, Hutchinson CM, Jacobs M, Jorgensen JO, Jossart G, Lakdawala M, Nguyen NT, Nocca D, Prager G, Pomp A, Ramos AC, Rosenthal RJ, Shah S, Vix M, Wittgrove A, Zundel N. International Sleeve Gastrectomy Expert Panel Consensus Statement: best practice guidelines based on experience of >12,000 cases. Surg Obes Relat Dis. 2012 Jan-Feb;8(1):8-19. doi: 10.1016/j.soard.2011.10.019. Epub 2011 Nov 10.
PubMed 22248433Longitudinal Assessment of Bariatric Surgery (LABS) Consortium; Flum DR, Belle SH, King WC, Wahed AS, Berk P, Chapman W, Pories W, Courcoulas A, McCloskey C, Mitchell J, Patterson E, Pomp A, Staten MA, Yanovski SZ, Thirlby R, Wolfe B. Perioperative safety in the longitudinal assessment of bariatric surgery. N Engl J Med. 2009 Jul 30;361(5):445-54. doi: 10.1056/NEJMoa0901836.
PubMed 19641201American Society for Metabolic and Bariatric Surgery Clinical Issues Committee. American Society for Metabolic and Bariatric Surgery position statement on global bariatric healthcare. Surg Obes Relat Dis. 2011 Nov-Dec;7(6):669-71. doi: 10.1016/j.soard.2011.08.009. Epub 2011 Aug 27. No abstract available.
PubMed 21955741Sjostrom L, Lindroos AK, Peltonen M, Torgerson J, Bouchard C, Carlsson B, Dahlgren S, Larsson B, Narbro K, Sjostrom CD, Sullivan M, Wedel H; Swedish Obese Subjects Study Scientific Group. Lifestyle, diabetes, and cardiovascular risk factors 10 years after bariatric surgery. N Engl J Med. 2004 Dec 23;351(26):2683-93. doi: 10.1056/NEJMoa035622.
PubMed 15616203
Study at a glance
From the registry record, last updated by the sponsor on 6 May 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Efficacy and Safety of the Luso-Cor Esophageal Stent Compared to Other Endoscopic Techniques in the Management of Fistulas and Anastomotic Dehiscences After Upper Digestive Tract Surgery (ES-LCCE-UDFM)
- ClinicalTrials.gov ID
- NCT06862479
- Acronym / sponsor ID
- ES-LCCE-UDFM / 001
- Conditions
- Obesity, Obesity, Morbid, Esophageal Cancer, Esophageal Neoplasms, Gastric Cancer, Gastric Adenocarcinoma
- Keywords
- Fistulas, Anastomotic dehiscences, Endoscopic management, Stents, Endoscopic vacuum therapy
- Study type
- Observational
- Recruitment status
- Enrolling by invitation
- Enrolment
- 180 participants (estimated)
- Lead sponsor
- Unidade Local de Saúde Santa MariaOther government
- Study start
- 1 Jan 2025 (actual)
- Primary completion
- 1 Jan 2028 (estimated)
- Study completion
- 1 Jan 2030 (estimated)
- First posted
- 6 Mar 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The global prevalence of obesity has prompted an increase in bariatric surgery, which is the only management strategy that provides long-term weight loss and improvement of obesity-related diseases. Bariatric surgeries include sleeve gastrectomy(SG), Roux-en-Y gastric bypass(RYGB),and laparoscopically adjustable gastric banding(LAGB). The incidence of adverse events depends on the type of bariatric surgery performed, with serious adverse events occurring in approximately 4% and mortality in 0.1% patients. The incidence of fistulas after SG varies between 0.2% to 2.5% and between 1% and 4.9% in patients who have undergone an RYGB. The incidence of strictures after SG is approximately 0.35%. Older, more obese, and male patients with multiple comorbidities related to obesity are at increased risk for the development of fistulas and mortality following bariatric surgery. Additionally, surgery after LAGB increases the risk of adverse events.
This study will compare the efficacy and safety of the Luso-Cor esophageal stent versus conventional covered metallic stents versus endoscopic vacuum therapy in the management of fistulas and anastomotic dehiscences after oncologic or bariatric surgery on the stomach and esophagus.
Detailed description
The morbidity and mortality related to adverse events increases with surgical re-exploration at the site of a fistula orifice. For this reason, management of fistulas after bariatric surgery has shifted from a surgical to a primarily endoscopic approach, primarily with covered metallic stents, with fistula closure success rates between 75% and 100%. However, a primarily endoscopic approach is demanding in terms of resource use, and the high incidence of stent migration often requires multiple reinterventions - both endoscopically and surgically.
The Luso-Cor esophageal stent was designed to take into account altered anatomy after bariatric surgery and to overcome strictures in the gastric tube, which can be concomitantly present in patients with fistulas following SG. A pilot study involving 15 patients with fistulas after sleeve gastrectomy managed with the Luso-Cor esophageal stent showed a 100% rate of fistula closure, low rate of adverse events with only one episode of stent dysfunction.
A recent meta-analysis suggested that endoscopic vacuum therapy (EVT) was associated with a 21% increase in successful fistula closure compared to self expanding metallic stents (RD 0.21, CI 0.10-0.32; P = 0.0003), a 12% reduction in mortality compared to stenting (RD 0.12, CI 0.03-0.21; P = 0.006) and an average reduction of 14.22 days in duration of treatment (CI 8.38-20.07; P < 0.00001). Additionally, EVT was associated with a 24% reduction in adverse events (RD 0.24, CI 0.13-0.35; P = 0.0001. There were no statistical differences between the studied therapies regarding the length of hospital stay.
Therefore, this study aims to evaluate and compare the success of the novel Luso-Cor esophageal stent in the exclusion of fistulas, reinterventions, stent-related adverse events, duration of hospitalization and its efficacy in the management of fistulas after SG compared to other stents or EVT.
Hypothesis of the study The novel concept of esophageal anchoring of a specially designed long stent may be useful in management of fistulas after gastric surgery with high success rate and minimal morbidity compared to conventionally available esophageal or bariatric surgery stents and EVT.
Objectives of the study
To evaluate and compare the performance of the Luso-Cor oesophageal stent with other stents or EVT in management of fistulas after bariatric and oncologic surgery on the upper digestive tract with regard to:
- Technical success defined as successful deployment of the stent at the desired location and exclusion of the fistula orifice.
- Clinical efficacy defined as successful closure of the fistula orifice after stent removal.
- Safety - Early and late adverse events related to stent placement.
- Duration of hospitalization
- Number of endoscopic procedures required till fistula closure
- Mortality
Inclusion criteria Patients undergoing endoscopic management of fistulas after bariatric surgery or dehiscences of esophago-jejunal, esophago-gastric or gastro-jejunal anastomosis after esophageal or gastric oncologic surgery will be included in the study.
Exclusion criteria
- Pregnancy
- Age < 18years
- Inability to give informed consent.
Type of study: Prospective observational multicentre study.
Materials and methods Conventional covered metallic and bariatric surgery stents and EVT will be used as per standard of care.
Design features of the Luso-Cor esophageal stent: This is a specifically designed stent to manage fistulas after sleeve gastrectomy, Roux-en-Y gastric bypass and esophago-jejunal anastomotic dehiscences after total gastrectomy. This metallic stent measuring 24 cm in length is covered with silicone and has three sections: 1) A proximal flared portion with diameters of 30, 34 and 36 mm measuring 6 cm in length; 2) Middle narrow portion with a fixed diameter of 20 mm measuring 16 cm in length; and 3) Distal flared portion with a fixed diameter of 30 mm measuring 2 cm in length.
Esophageal anchoring, is achieved through the larger diameter of the proximal flared portion compared to conventional stents and a 5 mm uncovered portion located 1 cm below the proximal edge of the stent. The remainder of the stent is covered with a thin silicone coating. This contrasts with the conventional partially covered metallic esophageal stents which usually have at least 1 cm of uncovered portions near the proximal and distal edges.
There are two zones within the middle narrowed portion of the stent which allow articulation of the stent on itself up to 90º. This allows the stent to adapt to altered anatomy and peristaltic activity of the foregut. The distal flared portion of the stent is designed to be placed in the gastric antrum or in the proximal jejunum, to avoid peri-stent reflux of enteric fluid.
Radio-opaque markers are placed at the proximal and distal edge of the stent and at the junction of the proximal flared portion with the middle narrow portion, unlike conventional metallic esophageal where the radio-opaque markers are placed at the stent edges and in the middle.
Stent placement: Placement of the stent is done by over the wire technique and ideally with X-ray imaging control. It can also be done with endoscopic control by the bedside in emergencies. The distal edge of the stent should be placed at least 2 cm proximal to the pylorus and the proximal flared portion should be placed in the distal esophagus, at least 2 cm above the esophago-gastric junction or esophago-jejunal anastomosis. During stent delivery, after verifying opening of the distal flare of the stent near the pylorus, the endoscopist should focus on the radio-opaque markers in the proximal portion of the stent which are separated by 6 cm so that the proximal flare is liberated in the distal third of the esophagus.
Due to the usually smaller diameter of the esophagus in women, we recommend the use of the Luso-Cor esophageal stent with proximal flare of 30 mm diameter in women and 34 and 36 mm diameters in men. However, the endoscopist should choose the ideal diameter based on the endoscopic assessment of the esophageal lumen diameter prior to stent placement.
After deployment, the stent should be kept in place for at least 4 weeks and up to a maximum of 12 weeks. An oral contrast study should be done 48 to 72 hoursafter stent deployment to confirm effective exclusion of fistula orifice after which oral dietary intake may be commenced. All patients should receive proton pump inhibitors (PPIs) twice a day with a recommendation for head elevation in the supine position to decrease reflux esophagitis.
Stent Removal: Stent removal is easy compared to conventional stents. It requires ablation of the mucosal ingrowth in the 5mm uncovered portion near the proximal edge of the stent with argon plasma 50W/1L, followed by scraping of the tissue with a cap applied at the tip of the endoscope and capture of the drawstring at the proximal edge of the stent with a rat tooth forceps.
Clinical data and management strategy of patients with fistulas or anastomotic dehiscences:
The type of stent used or option for use of EVT as first line endoscopic option will be at the discretion of the endoscopist.
The Luso-Cor esophageal stent was approved for clinical use in Portugal in 2016 by regulatory authorities (INFARMED).
After diagnosis of fistulas, whenever required, patients should undergo surgical peritoneal toillete either by laparotomy or laparoscopy with placement of abdominal drains.
Informed consent for endoscopic procedures to manage fistulas or anastomotic dehiscences will be obtained from all patients.
The location and size of the fistula orifice will be determined and the presence of concomitant stricture of the gastric tube noted endoscopically.
Fistulas will be considered as acute if endoscopy was performed within one month of surgery and chronic if performed >1 month after surgery.
Whenever possible, the fistula orifice will be closed with either through the scope clips(TTSCs) or the over the scope clips(OTSCs). Small fistula orifices measuring <5 mm will be initially managed with either TTSCs or OTSCs.
The Luso-Cor esophageal stent may be used as the first option in patients with fistula orifices >5 mm either alone or in combination with OTSCs or TTSCs, in those patients who have fistula persistence after initial application of TTSCs or OTSCs or in those with concomitant stricture in the gastric tube detected endoscopically.
Gastroesophageal reflux disease after stent placement will be managed with double dose PPI and sucralfate 1g up to 4 times a day.
Definitions Technical success will be defined as correct placement and coaptation of the stent at the previously planned location under fluoroscopic imaging with radio-opaque markers with effective exclusion of fistula orifice.
Clinical efficacy will be defined as closure of the fistula orifice after Luso-Cor esophageal stent removal. Definitive closure of the fistula orifice should be confirmed by contrast injection during endoscopy and / or oral contrast study after Luso-Cor esophageal stent removal.
A secondary endpoint of clinical efficacy will be the effectiveness of the Luso-Cor esophageal stent or other stents in managing fistulas in the gastric tube after vertical gastrectomy.
Stent related adverse events will be defined as early (within 1 week of stent placement) and late (> 1 week after stent placement) and include stent migration, perforation, hemorrhage, stent fracture and mortality.
Primary outcome for this study will be closure of the fistula orifice after stent removal. Secondary outcomes will be effectiveness of the stent in managing strictures in the gastric tube, stent-related adverse events, number of endoscopies, motives for endoscopic reinterventions and the number of stents used, duration of hospitalization and fistula or stent-related mortality.
Simple fistulas will be defined as fistulas communicating between a hollow organ and the peritoneum or pleura (Gastro-pleural or gastro-peritoneal).
Complex fistulas will be defined as fistulas communicating between two hollow organs (Gastro-bronquial) or between a hollow organ and the skin (Gastro-cutaneous) or those with sub-divisions and multiple trajectories in continuity with a fistula orifice.
All procedures will be performed in accordance with the ethical standards of the institution and with the 1964 Helsinki declaration.
Statistical Analysis Qualitative data will be presented as percentages and quantitative data as median (Min-Max). Factors at baseline predicting technical success, clinical success, clinical efficacy and development of adverse events will be evaluated using the Logistic regression analysis.
Qualitative data will be compared with the Chi-square test and quantitative data will be compared with the Student´s t test or Mann-Whitney test if the distribution is normal or non-normal.
Multivariate analysis will take into account all factors at baseline associated with the outcomes measured (p<0,1) and will be performed using the backward stepwise regression.
A p value <0,05 will be considered statistically significant. Data will be analyzed using IBM SPSS 21 (SPSS Inc., Chicago, IL, USA).
Study design
- Observational model
- Other
- Time perspective
- Prospective
- Target follow-up
- 1 Year
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Fistulas after oncologic or bariatric surgery on the stomach or esophagus | – | Procedure: Endoscopic management of fistulas with stents or vacum therapyPatients who develop fistulas after oncologic surgery on the stomach or esophagus or those patients who develop fistulas after bariatric surgery (Vertical or sleeve gastrectomy or gastric bypass) managed endoscopically with endoscopic vacuum therapy group. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients who develop fistulas or anastomotic dehiscences after oncologic surgery on the stomach or esophagus or after bariatric surgery.
Key inclusion criteria (1 listed)
- Patients undergoing endoscopic management of fistulas after bariatric surgery or dehiscences of esophago-jejunal or gastro-jejunal anastomosis after esophageal or gastric oncologic surgery will be included in the study.
Key exclusion criteria (3 listed)
- Pregnancy
- Age < 18years
- Inability to give informed consent.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Endoscopic management of fistulas with stents or vacum therapyA prospective registry of patients who develop fistulas after oncologic surgery on the stomach or esophagus as well as those after bariatric surgery and managed endoscopically with stents or endoscopic vacuum therapy will be evaluated to assess and compare the efficacy and safety of the Luso-Cor versus conventional partially or fully covered metallic stents or bariatric stents or endoscopic vacuum therapy. | Procedure or surgery | Fistulas after oncologic or bariatric surgery on the stomach or esophagus |
Primary outcome
Compare the efficacy of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery in terms of fistula closure.
Time frame: 36 months for recruitment of 180 patients.
To evaluate and compare the performance of the Luso-Cor oesophageal stent with other stents or EVT in management of fistulas after bariatric and oncologic surgery on the upper digestive tract with regard to fistula closure rate expressed as percentage
Compare the safety of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery in terms of rate of adverse events
Time frame: 36 months for recruitment of 180 patients.
To evaluate and compare the safety of the Luso-Cor oesophageal stent with other stents or EVT in management of fistulas after bariatric and oncologic surgery on the upper digestive tract with regard to early and late adverse event rate expressed as percentage.
4 secondary outcomes
Compare the technical success of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery
Time frame: 36 months for recruitment of 180 patients.
Compare duration of hospitalization in patients developing fistulas after oncologic surgery on the stomach and esophagus or bariatric surgery managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy.
Time frame: 36 months for recruitment of 180 patients.
Compare the number of endoscopies till fistula closure in patients managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy who developed fistulas after oncologic surgery on the stomach and esophagus or bariatric surgery.
Time frame: 36 months for recruitment of 180 patients.
Compare the mortality in patients who developed fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery, managed with the Luso-Cor versus conventional stents versus endoscopic vacuum therapy.
Time frame: 36 months for recruitment of 180 patients.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 May 2026.
- Background: PubMed 33300634do Monte Junior ES, de Moura DTH, Ribeiro IB, Hathorn KE, Farias GFA, Turiani CV, Medeiros FS, Bernardo WM, de Moura EGH. Endoscopic vacuum therapy versus endoscopic stenting for upper gastrointestinal transmural defects: Systematic review and meta-analysis. Dig Endosc. 2021 Sep;33(6):892-902. doi: 10.1111/den.13813. Epub 2020 Oct 28.
- BackgroundClinical Efficacy and Safety of a Novel Stent for Fistula Management Following Sleeve Gastrectomy Noronha Ferreira, Carlos et al. Techniques and Innovations in Gastrointestinal Endoscopy, Volume 26, Issue 1, 12 - 20
- Background: PubMed 17611917Eisendrath P, Cremer M, Himpens J, Cadiere GB, Le Moine O, Deviere J. Endotherapy including temporary stenting of fistulas of the upper gastrointestinal tract after laparoscopic bariatric surgery. Endoscopy. 2007 Jul;39(7):625-30. doi: 10.1055/s-2007-966533.
- Background: PubMed 30247333Kanters AE, Shubeck SP, Varban OA, Dimick JB, Telem DA. Incidence and Efficacy of Stent Placement in Leak Management After Bariatric Surgery: An MBSAQIP Analysis. Ann Surg. 2020 Jan;271(1):134-139. doi: 10.1097/SLA.0000000000003023.
- Background: PubMed 21521563Swinnen J, Eisendrath P, Rigaux J, Kahegeshe L, Lemmers A, Le Moine O, Deviere J. Self-expandable metal stents for the treatment of benign upper GI leaks and perforations. Gastrointest Endosc. 2011 May;73(5):890-9. doi: 10.1016/j.gie.2010.12.019.
- Background: PubMed 21295637Bege T, Emungania O, Vitton V, Ah-Soune P, Nocca D, Noel P, Bradjanian S, Berdah SV, Brunet C, Grimaud JC, Barthet M. An endoscopic strategy for management of anastomotic complications from bariatric surgery: a prospective study. Gastrointest Endosc. 2011 Feb;73(2):238-44. doi: 10.1016/j.gie.2010.10.010.
- Background: PubMed 18471727Eubanks S, Edwards CA, Fearing NM, Ramaswamy A, de la Torre RA, Thaler KJ, Miedema BW, Scott JS. Use of endoscopic stents to treat anastomotic complications after bariatric surgery. J Am Coll Surg. 2008 May;206(5):935-8; discussion 938-9. doi: 10.1016/j.jamcollsurg.2008.02.016.
- Background: PubMed 22047699Puli SR, Spofford IS, Thompson CC. Use of self-expandable stents in the treatment of bariatric surgery leaks: a systematic review and meta-analysis. Gastrointest Endosc. 2012 Feb;75(2):287-93. doi: 10.1016/j.gie.2011.09.010. Epub 2011 Nov 1.
- Background: PubMed 14691697Fernandez AZ Jr, DeMaria EJ, Tichansky DS, Kellum JM, Wolfe LG, Meador J, Sugerman HJ. Experience with over 3,000 open and laparoscopic bariatric procedures: multivariate analysis of factors related to leak and resultant mortality. Surg Endosc. 2004 Feb;18(2):193-7. doi: 10.1007/s00464-003-8926-y. Epub 2003 Dec 29.
- Background: PubMed 26699374van Wezenbeek MR, de Milliano MM, Nienhuijs SW, Friederich P, Gilissen LP. A Specifically Designed Stent for Anastomotic Leaks after Bariatric Surgery: Experiences in a Tertiary Referral Hospital. Obes Surg. 2016 Aug;26(8):1875-80. doi: 10.1007/s11695-015-2027-6.
- Background: PubMed 18392906Ballesta C, Berindoague R, Cabrera M, Palau M, Gonzales M. Management of anastomotic leaks after laparoscopic Roux-en-Y gastric bypass. Obes Surg. 2008 Jun;18(6):623-30. doi: 10.1007/s11695-007-9297-6. Epub 2008 Apr 8.
- Background: PubMed 22248433Rosenthal RJ; International Sleeve Gastrectomy Expert Panel; Diaz AA, Arvidsson D, Baker RS, Basso N, Bellanger D, Boza C, El Mourad H, France M, Gagner M, Galvao-Neto M, Higa KD, Himpens J, Hutchinson CM, Jacobs M, Jorgensen JO, Jossart G, Lakdawala M, Nguyen NT, Nocca D, Prager G, Pomp A, Ramos AC, Rosenthal RJ, Shah S, Vix M, Wittgrove A, Zundel N. International Sleeve Gastrectomy Expert Panel Consensus Statement: best practice guidelines based on experience of >12,000 cases. Surg Obes Relat Dis. 2012 Jan-Feb;8(1):8-19. doi: 10.1016/j.soard.2011.10.019. Epub 2011 Nov 10.
- Individual participant dataSharing planned: No. This is an investigator driven study which aims to evaluate and compare efficacy of the Luso-Cor esophageal stent versus conventional covered stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery
Related trials for Obesity
RecruitingObservational study
Early Tracking of Childhood Health Determinants (ETCHED) Study
Diabetes Mellitus, Obesity
Active, not recruiting
Effect of the Thrive AI Health App on Lifestyle Behaviors and Quality of Life
Diabetes Type 2, Overweight or Obesity
Not yet recruitingPhase 3
SYNCHRONIZE®-START- A Study to Test Whether Survodutide Helps People Living With Overweight or Obesity Who do Not Have Diabetes to Lose Weight
Obesity
Not yet recruitingObservational study
Assessing the Impact of Perceptions of Unpredictability on Objective Measures of Food Consumption and Metabolism
Healthy Volunteer, Obestity
Not yet recruitingPhase 1/2
Investigating the Effects of 24 Hour LEAP2 Infusion in Individuals With Overweight and Obesity
Obesity & Overweight
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Carlos Noronha Ferreira, MD, MSc, PhD principal investigator
Serviço de Gastrenterologia e Hepatologia, Unidade Local de Saúde Santa Maria
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Obesity and Obesity, Morbid, run by Unidade Local de Saúde Santa Maria at 1 site in Portugal.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: enrolling by invitation, as of the sponsor's last update on 6 May 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Portugal. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Compare the efficacy of the Luso-Cor versus conventional stents versus endoscopic vacuum therapy in the management of fistulas after oncologic surgery on the stomach and esophagus and bariatric surgery in terms of fistula closure. (time frame: 36 months for recruitment of 180 patients.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06862479, which also lists 17 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 May 2026.