AzTrials
AzTrials

Bone ScanIATOS2NCT06782438

Evaluation of an Artificial Intelligence Algorithm Reducing Noise on Fast Whole-body Bone Tomoscintigraphy Acquisitions Recorded by a 360 Degree Cadmium-Zinc-Tellurid Camera

An observational study of Bone Scan, run by Central Hospital, Nancy, France at 1 site in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Recently, artificial intelligence algorithms reducing noise by deep learning have been developed with application to SPECT and PET images. Many studies have reported the possibility of reducing the recording time in bone scintigraphy by applying artificial intelligence algorithms reducing noise Read more about this study

Who is it for?
Ages 18 to 99 years
Conditions the study is for
Bone Scan
What is being tested?
artificial intelligence algorithm
How many people
20 participants
Where
1 siteFrance
Study dates
27 Feb 2025to 30 Mar 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients who had a whole-body thee dimensions bone scan for rheumatological or oncological indications and non opposed to th use of their data

Who may be able to join

  • Patients who had a whole-body thee dimensions bone scan for rheumatological or oncological indications.

Who cannot join

  • Patients opposed to the use of their data

Trial locations and contacts

1 site in 1 country.

France1 site
  • Nuclear Medicine Department

    Vandœuvre-lès-Nancy, 54511

Other trials in France

About this study

Recently, artificial intelligence algorithms reducing noise by deep learning have been developed with application to SPECT and PET images.

Many studies have reported the possibility of reducing the recording time in bone scintigraphy by applying artificial intelligence algorithms reducing noise

Read the detailed description

Only two studies compared images denoised by a Deep Learning algorithm to those denoised by conventional filters (Gaussian and median filters). The first study was conducted only on patients, without phantom analysis and without taking into account the size of the lesions. The second study included an analysis on phantom and patients, but with application to planar images rather than to SPECT images that are increasingly used today

The hypothesis of our study conducted on phantom and patients is that an artificial intelligence algorithm reducing noise could replace the conventional filters usually used in bone SPECT for the denoising of scintigraphic images.

Conditions
Bone Scan
Being tested
artificial intelligence algorithm

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • artificial intelligence algorithmOther

    to apply an artificial intelligence algorithm to treat the imaging

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. To compare imaging treated by the intelligence artificial algorithm with imaging treated with the traditionnal filter artificial algorithm

    Quantification value on imaging measured with intelligence artificial algorithm compared with quantification value measured with conventional filter

    Measured: one day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Jan 2025
  2. Study start27 Feb 2025
  3. Primary completion15 Mar 2025
  4. Study completion30 Mar 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Retrospective
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06782438
Sponsor's protocol ID
2024PI241
Acronym
IATOS2
Status last verified
Jun 2026
First submitted
7 Jan 2025
Last updated
25 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Bahloul A, Rajadhas F, Doyen M, Lamash Y, Roth N, Roch V, Marie PY, Imbert L. A deep-learning noise reduction algorithm outperforms the spatial filters previously required for bone SPECT on a high-speed whole-body 360 degrees CZT-camera. EJNMMI Res. 2025 Dec 31;16(1):19. doi: 10.1186/s13550-025-01344-1.

    PubMed 41474536

Questions about this trial

What is this clinical trial studying?

An observational study of Bone Scan, run by Central Hospital, Nancy, France at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 25 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

To compare imaging treated by the intelligence artificial algorithm with imaging treated with the traditionnal filter artificial algorithm (time frame: one day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06782438, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jun 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in