Cognitive ImpairmentAmyloid RPINCT06757569
Radialis PET Imager for the Assessment of Neuritic Amyloid Plaque Burden
A study testing PET in people with Cognitive Impairment, run by University Health Network, Toronto at 1 site in Canada.
Trial summary
The standard or usual workup for cognitive impairment, including Alzheimer's Disease, may include brain amyloid PET with PET/CT or PET/MR imaging. Amyloid PET is the standard imaging that was requested for you by your referring physician. This imaging can visualize your brain. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Cognitive Impairment
- What is being tested?
- PET
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 160 participants
- Where
- 1 siteCanada
- Study dates
- 6 Dec 2024to 31 Dec 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age ≥18 years
- Patients with cognitive impairment undergoing the standard of care brain 18F-Florbetaben PET imaging.
- Patients who can remain still for an additional scan of approximately 30-45 minutes.
- -
Who cannot join
- 1. Inability to provide informed consent. 2. Contraindication for PET examination as per institutional safety guidelines, including but not limited to pregnancy or inability to remain still for PET examination.
- -
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Canada1 site, 1 recruiting
- Recruiting
University Health Network, Toronto
Toronto, Ontario, M5G 2M9
Ur Metser, 416-946-4501 ext. 4394, ur.metser@uhn.ca
Noosha Yazdani, 416-946-4501 ext. 5927, noosha.yazdani@uhn.ca
About this study
The standard or usual workup for cognitive impairment, including Alzheimer's Disease, may include brain amyloid PET with PET/CT or PET/MR imaging. Amyloid PET is the standard imaging that was requested for you by your referring physician. This imaging can visualize your brain.
With the development of new therapies for Alzheimer's disease which require amyloid PET imaging, there will be a significant increase in the number of PET scans needed to provide care to all patients. There are likely not enough PET scanners in Canada to meet this demand. Therefore, we are searching for comparable alternatives. One of the imaging devices that was introduced in the clinic is the Radialis PET imager (or RPI). Health Canada, the regulatory body that oversees the use of devices in Canada, has not approved the sale or use of the Radialis PET imager. Health Canada has allowed the Radialis PET imager to be used in this study. We would like to see whether the images obtained for the brain are comparable to those obtained from a PET/CT or PET/MRI scanner. It is a new type of PET imaging device for patients undergoing a PET scan and has been used in Canada for research. RPI is experimental, meaning that this PET scan is not used routinely in patients' care.
Read more
In comparison to the standard PET devices, RPI is smaller and mobile, meaning it can be moved around easily for use. Also, it can be installed in imaging centers at a lower cost. These advantages make RPI an interesting alternative to the standard PET. However, the performance of this new imaging device has not been tested in Amyloid PET imaging in particular.
As you may know, in a PET scan, we inject a radioactive material (called tracer) which can circulate in your body and visualize specific areas in your body. In amyloid PET we inject an amyloid tracer that goes to the brain and lights up certain regions of the brain.
RPI was previously tested for other PET tracers and was shown to be comparable to standard PET devices. Thus, by changing the PET material (to Amyloid), we are pursuing the same aim: comparison of RPI with standard PET devices and see whether it can provide comparable images of the brain.
Read the detailed description
Background Information and Scientific Rationale
It is estimated that more 1.3 million people in Canada live with mild cognitive impairment, and more than a quarter of a million people in Canada live with mild dementia. The most common form of dementia is Alzheimer's disease, implicated in approximately two-thirds of cases (1, 2). The proportion of the population living with dementia is expected to increase in the coming decades, due to the increase in life span, aging of the population, and the prevalence of dementia in those over age 75. By 2050, the incidence of dementia may triple, impacting millions of Canadians, their families, the health care system and the economy (3).
Current consensus guidelines recommend cholinesterase inhibitors for the symptomatic treatment of dementia caused by Alzheimer's disease, which may slightly delay cognitive decline, and memantine for the symptomatic treatment of moderate-to-severe cases (4). On July 6, 2023, the FDA granted full approval for lecanemab, the first disease-modifying drug for Alzheimer's disease. Lecanemab is a human monoclonal antibody that targets amyloid-β soluble protofibrils and oligomers with high affinity and has low affinity against amyloid-β monomers and insoluble fibrils. According to the amyloid hypothesis, soluble and insoluble amyloid-β peptides trigger a cascade that impairs neurons and synapses in the brain, leading to cognitive decline (5). In the Clarity AD randomized phase III trial, patients aged 50-90 with clinical and biomarker evidence of mild cognitive impairment caused by Alzheimer's disease, including PET or CSF analysis demonstrating amyloid burden and MR brain excluding alternative causes, those receiving lecanemab had statistically significantly greater reductions in brain amyloid burden than with placebo (difference, -59.1 centiloids; 95% CI, -62.6 to -55.6) and lower rates of cognitive decline on the Clinical Dementia Rating - Sum of Boxes (CDR-SB) and other measures of cognition. Amyloid-related imaging abnormalities with edema or effusions (ARIA-E) were reported in 12.6% of those receiving the drug (6).
Enabling access to disease-modifying medications for Alzheimer's disease in Canada poses multiple challenges to provincial and territorial healthcare systems. To determine eligibility for therapy, and to assess efficacy, patients would need to undergo PET to assess neuritic amyloid plaque burden. Across many jurisdictions, including in Canada, there is limited PET/CT scanner capacity. With competitive and expanding indications in oncology, the introduction of new oncology tracers (PSMA, SSTR-peptide tracers) and high-volume non-oncology indications such as PET myocardial perfusion imaging (82Rb PET), there is little capacity to perform amyloid PET imaging (7). Furthermore, tracer availability is currently limited. Without an increase in scanner and tracer availability, these may result in a significant barrier to the clinical rollout of disease-modifying drugs in Canada.
Organ-based PET technology, such as positron emission mammography, has been evaluated for a few decades. Recently, an organ-targeted Radialis PET Imager (RPI), using two planar detector heads mounted on a movable gantry was developed using hardware improvements to increase sensitivity and noise equivalent count rate (NECR) performance across a clinically useful activity range, down to low-dose activities at 1/10th of a standard dose (8, 9). The RPI system has undergone extensive validation in laboratory settings, utilizing a comprehensive set of standardized experiments outlined in the National Electrical Manufacturers Association (NEMA) NU-4 standards. These experiments serve to objectively compare the performance of the RPI with that of other organ-targeted PET and whole-body (WB) PET/CT systems available on the market or in clinical trials. NEMA tests have demonstrated an in-plane spatial resolution of 2.3 ± 0.1 mm, which is comparable to the best-in-class organ-targeted PET scanners. Additionally, the RPI system achieves a peak sensitivity of 3.5% and an average system sensitivity of 2.4%, surpassing the sensitivity of all available PET scanners. In terms of NECR, the peak NECR of 5,400 cps/MBq of the RPI is much larger than that of any WB or organ-targeted systems. The detectability of small objects was demonstrated using Micro hotspot phantom images, where micro hotspot phantom sources were visualized down to 1.35 mm diameter rods, simulating the detectability of very small objects and lesions.
The combination of the highest count rate capability, peak slice sensitivity, peak absolute slice sensitivity, and high spatial resolution of the RPI suggests superior overall efficiency in activity detection compared to any other PET technology. The first clinical evaluation of the RPI was for the detection of breast cancer with 18F-FDG in comparison with digital full-field mammography, magnetic resonance imaging (MRI), and WB PET images. Published results from clinical trials confirmed an improved resolution and detectability of small lesions compared to WB-PET and demonstrated the capability to identify false-negative X-ray findings and characterize false-positive MRI findings (for RPI, the false-positive rate was only 16% vs the 62% observed for MRI), even at up to a 10-fold dose reduction in comparison with standard FDG doses (i.e., at 37 MBq or 1 mCi) (9). Overall, if validated against standard of care PET/CT, a mobile, organ-based PET camera with high sensitivity detectors using lower injected tracer dose for the detection of neuritic beta-amyloid plaques could increase the availability of amyloid brain PET imaging in Canada and other jurisdictions and decrease associated costs. The purpose of this study is to evaluate the feasibility of using the Radialis PET Imager for the detection of amyloid plaque burden using PET amyloid tracer (18F-Florbetaben).
Hypothesis Phase I: Radialis PET Imaging (RPI) of the brain using amyloid PET tracer (18F-Florbetaben) is feasible.
Phase II: RPI can provide comparable diagnostic accuracy to the current standard of care 18F-Florbetaben PET.
Objectives Primary Objective To assess the feasibility of amyloid brain PET imaging using RPI To determine whether qualitative 18F-Florbetaben PET images obtained with RPI are diagnostically equivalent to those obtained with a standard-of-care PET scanner (PET/CT or PET/MR).
Secondary Objectives To determine whether lower doses of amyloid tracer can result in diagnostic RPI examinations.
To determine optimal dose and acquisition time for RPI.
To compare quantitative parameters:
Standardised Uptake Value ratio (SUVr) obtained by commercially available software (Hermes - BRASS):
SUVr= (SUV_VOI)/(SUV_(reference region) )
Where for a decay corrected administered activity concentration A_con^VOI the SUV in a given VOI will be calculated as follows:
SUV_VOI= (A_con^VOI)/(A_con^adm )
Mean SUVr and the voxel-wise standard deviation (SD) will be calculated for each assessed region in each subject. To assess tracer uptake agreement between images, the coefficient of variation (CV=SD/mean) will be calculated and compared between acquisition methods (10).
Signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) will be calculated for 8 standardized samples (VOIs) in 3 brain regions: cerebellum (2 samples), brain stem, cerebrum (4 samples), as follows:
SNR(VOI)= (Mean(VOI))/(SD(VOI))
CNR= (Mean(GM)-Mean(WM))/(SD(WM))
STUDY DESIGN 1 Overview A single-arm prospective trial with 2 phases
Phase I - Optimization of brain PET imaging technique and data reconstruction methods.
For this purpose, up to 10 patients will be recruited. Patients who are already scheduled for a clinical 18F-Florbetaben PET/CT or PET/MRI as per the current clinical indication in Ontario (PET scans and tracer are funded by the PET program, Cancer Care Ontario) will be screened and contacted for recruitment. The scheduled scans will be obtained and read clinically as per the standard of care.
After completing the clinical scan, consenting patients will be scanned on the RPI camera (within three hours). No additional tracer will be injected. No additional radiation exposure will be applied. The injection dose and time from injection to RPI will be recorded (for calculation of dose correction). Data will be stored and reconstructed from a 3D dataset in 3 planes (coronal, sagittal and axial). RPI attenuation correction will be atlas-based.
RPI imaging technique will be assessed for patient comfort and compliance, to ensure scanning fields result in complete coverage of the region of interest, to determine minimal and optimal scan time for maximizing image quality, and to validate the reconstruction and attenuation correction methods used. Imaging quality on original PET and the RPI acquisition will be assessed quantitatively: including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and coefficient of variation (CV) and qualitatively by independent review of 2 reviewers with image quality scored on a 4-point scale (4= excellent; 3 = good/ satisfactory; 2= suboptimal; 1 = nondiagnostic).
Finally, images will be reconstructed from list mode to simulate 10%, 25%, 50%, 75%, and 100% of the injected dose and assessed qualitatively and diagnostically. When all data has been obtained, the reconstructed datasets will be presented to 2 readers in random order. The minimal dose for which a diagnostic exam can be obtained will be determined.
Once the image acquisition technique is optimized and reconstruction of data is validated, the second phase of the study will commence.
Phase II - Validation of RPI against PET (PET/CT or PET/MR) for amyloid PET imaging
- Diagnostic performance For this purpose, 150 patients will be assessed using the finalized imaging protocol developed in Phase I. Each scan will be read as per standard protocol. In brief, each of the 4 assessed regions, the lateral temporal lobe, frontal cortex, posterior cingulate/ precuneus and parietal cortex, will be assessed and scored as per the Regional Cortical Tracer Uptake (RCTU) scoring system, as follows: score 1 - negative; score 2- moderate; score 3- significant tracer uptake. A scan with RCTU score of 1 in each of the 4 brain regions receives a β-amyloid Plaque Load (BAPL) score of 1 indicating no significant β-amyloid plaque load. A scan with RCTU score of 2 in at least one brain region and no score of 3 in any region will receive a BAPL score of 2, indicating moderate β-amyloid plaque load. Finally, a scan with RCTU score of 3 in at least one of the brain regions will receive a BAPL score of 3, indicating significant β-amyloid plaque load. The same criteria will be used to assess each dataset - PET and RPI. To minimize bias, the scans will be read in batches of 5 patients, with the PET and RPI datasets shuffled and randomly presented to the reviewer. Each scan will be interpreted independently by 2 reviewers, with a final consensus read on each imaging modality (PET and RPI), if needed. If no consensus is achieved, a third arbitrator read will be obtained from a further independent reviewer. The concordance (inter-modality agreement) between PET and RPI on a regional level and overall patient level will be assessed.
- Feasibility of Dose Reduction To determine the clinical feasibility of using reduced-dose RPI examinations, the minimal injected dose, as determined by phase I, will be assessed independently quantitatively and qualitatively (RCTU = regional cortical tracer uptake; BAPL = brain β-amyloid plaque load where BAPL 1 = negative, BAPL 2 \& 3 = positive) and compared to the full-dose exam.
2 Sample size Phase I: 10 patients Phase II: 150 patients
Noninferiority sample size justification for matched samples:
For alpha =0.05; power (1-beta) = 0.95; assuming the technical success of 98.5% for each modality (PET and RPI) for a noninferiority limit of 5%, there would need to be 128 patients assessed with each test. Allowing for approximately 15% incomplete datasets (patients not completing imaging and/or nondiagnostic reference standard), sample size = 150 patients.
3 STUDY ENROLLMENT AND WITHDRAWAL 3.1 Inclusion Criteria 3.1.1. Age ≥18 years 3.1.2. Patients with cognitive impairment undergoing the standard of care brain 18F-Florbetaben PET imaging.
3.1.3. Patients who can remain still for an additional scan of approximately 30-45 minutes.
3.2 Exclusion Criteria 3.2.1. Inability to provide informed consent. 3.2.2. Contraindication for PET examination as per institutional safety guidelines, including but not limited to pregnancy or inability to remain still for PET examination.
- Conditions
- Cognitive Impairment
- Being tested
- PET
- Keywords
- Amyloid, PET, Alzheimer's disease
- Medical subject headings
- Cognitive Dysfunction, Alzheimer Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
PETDevice
Feasibility assessment of using the Radialis PET Imager for the detection of amyloid plaque burden using PET amyloid tracer.
| Study group | Role | What they receive |
|---|---|---|
| Single arm, observational | Other | Single arm, observational Receives: Device: PET |
What is being measured
The primary outcome is the main question the study is designed to answer.
feasibility of amyloid brain PET imaging using RPI
Number of diagnostic exams performed with RPI compared to standard PET.
Measured: 2 years
Secondary outcomes (3)
Qualitative assessment
To determine whether qualitative 18F-Florbetaben PET images obtained with RPI are diagnostically equivalent to those obtained with a standard-of-care PET scanner (PET/CT or PET/MR).
Measured: 2 years
Tracer Dose
To determine the optimal dose of the amyloid tracer that can result in diagnostic RPI examination.
Measured: 2 years
Acquisition Time
To determine the optimal acquisition time for RPI that can result in diagnostic RPI examination.
Measured: 2 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted3 Jan 2025
- Study start6 Dec 2024
- Primary completion31 Dec 2026 (estimated)
- Study completion31 Dec 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Cognitive ImpairmentStudies of the same condition, open and under way.
- More trials run by University Health Network, TorontoThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Single arm cohort study
- Masking
- None (open label)
- Enrolment
- 160 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University Health Network, Toronto
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Ur Metser, University Health Network, Toronto
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06757569
- Sponsor's protocol ID
- 24-5482
- Acronym
- Amyloid RPI
- Status last verified
- Jan 2026
- First submitted
- 15 Dec 2024
- Last updated
- 3 Feb 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 3 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Radialis PET Imager for the Assessment of Neuritic Amyloid Plaque Burden
- ClinicalTrials.gov ID
- NCT06757569
- Acronym / sponsor ID
- Amyloid RPI / 24-5482
- Conditions
- Cognitive Impairment
- Keywords
- Amyloid, PET, Alzheimer's disease
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 160 participants (estimated)
- Lead sponsor
- University Health Network, TorontoUniversity, hospital or other
- Study start
- 6 Dec 2024 (actual)
- Primary completion
- 31 Dec 2026 (estimated)
- Study completion
- 31 Dec 2026 (estimated)
- First posted
- 3 Jan 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The standard or usual workup for cognitive impairment, including Alzheimer's Disease, may include brain amyloid PET with PET/CT or PET/MR imaging. Amyloid PET is the standard imaging that was requested for you by your referring physician. This imaging can visualize your brain.
With the development of new therapies for Alzheimer's disease which require amyloid PET imaging, there will be a significant increase in the number of PET scans needed to provide care to all patients. There are likely not enough PET scanners in Canada to meet this demand. Therefore, we are searching for comparable alternatives. One of the imaging devices that was introduced in the clinic is the Radialis PET imager (or RPI). Health Canada, the regulatory body that oversees the use of devices in Canada, has not approved the sale or use of the Radialis PET imager. Health Canada has allowed the Radialis PET imager to be used in this study. We would like to see whether the images obtained for the brain are comparable to those obtained from a PET/CT or PET/MRI scanner. It is a new type of PET imaging device for patients undergoing a PET scan and has been used in Canada for research. RPI is experimental, meaning that this PET scan is not used routinely in patients' care.
In comparison to the standard PET devices, RPI is smaller and mobile, meaning it can be moved around easily for use. Also, it can be installed in imaging centers at a lower cost. These advantages make RPI an interesting alternative to the standard PET. However, the performance of this new imaging device has not been tested in Amyloid PET imaging in particular.
As you may know, in a PET scan, we inject a radioactive material (called tracer) which can circulate in your body and visualize specific areas in your body. In amyloid PET we inject an amyloid tracer that goes to the brain and lights up certain regions of the brain.
RPI was previously tested for other PET tracers and was shown to be comparable to standard PET devices. Thus, by changing the PET material (to Amyloid), we are pursuing the same aim: comparison of RPI with standard PET devices and see whether it can provide comparable images of the brain.
Detailed description
Background Information and Scientific Rationale
It is estimated that more 1.3 million people in Canada live with mild cognitive impairment, and more than a quarter of a million people in Canada live with mild dementia. The most common form of dementia is Alzheimer's disease, implicated in approximately two-thirds of cases (1, 2). The proportion of the population living with dementia is expected to increase in the coming decades, due to the increase in life span, aging of the population, and the prevalence of dementia in those over age 75. By 2050, the incidence of dementia may triple, impacting millions of Canadians, their families, the health care system and the economy (3).
Current consensus guidelines recommend cholinesterase inhibitors for the symptomatic treatment of dementia caused by Alzheimer's disease, which may slightly delay cognitive decline, and memantine for the symptomatic treatment of moderate-to-severe cases (4). On July 6, 2023, the FDA granted full approval for lecanemab, the first disease-modifying drug for Alzheimer's disease. Lecanemab is a human monoclonal antibody that targets amyloid-β soluble protofibrils and oligomers with high affinity and has low affinity against amyloid-β monomers and insoluble fibrils. According to the amyloid hypothesis, soluble and insoluble amyloid-β peptides trigger a cascade that impairs neurons and synapses in the brain, leading to cognitive decline (5). In the Clarity AD randomized phase III trial, patients aged 50-90 with clinical and biomarker evidence of mild cognitive impairment caused by Alzheimer's disease, including PET or CSF analysis demonstrating amyloid burden and MR brain excluding alternative causes, those receiving lecanemab had statistically significantly greater reductions in brain amyloid burden than with placebo (difference, -59.1 centiloids; 95% CI, -62.6 to -55.6) and lower rates of cognitive decline on the Clinical Dementia Rating - Sum of Boxes (CDR-SB) and other measures of cognition. Amyloid-related imaging abnormalities with edema or effusions (ARIA-E) were reported in 12.6% of those receiving the drug (6).
Enabling access to disease-modifying medications for Alzheimer's disease in Canada poses multiple challenges to provincial and territorial healthcare systems. To determine eligibility for therapy, and to assess efficacy, patients would need to undergo PET to assess neuritic amyloid plaque burden. Across many jurisdictions, including in Canada, there is limited PET/CT scanner capacity. With competitive and expanding indications in oncology, the introduction of new oncology tracers (PSMA, SSTR-peptide tracers) and high-volume non-oncology indications such as PET myocardial perfusion imaging (82Rb PET), there is little capacity to perform amyloid PET imaging (7). Furthermore, tracer availability is currently limited. Without an increase in scanner and tracer availability, these may result in a significant barrier to the clinical rollout of disease-modifying drugs in Canada.
Organ-based PET technology, such as positron emission mammography, has been evaluated for a few decades. Recently, an organ-targeted Radialis PET Imager (RPI), using two planar detector heads mounted on a movable gantry was developed using hardware improvements to increase sensitivity and noise equivalent count rate (NECR) performance across a clinically useful activity range, down to low-dose activities at 1/10th of a standard dose (8, 9). The RPI system has undergone extensive validation in laboratory settings, utilizing a comprehensive set of standardized experiments outlined in the National Electrical Manufacturers Association (NEMA) NU-4 standards. These experiments serve to objectively compare the performance of the RPI with that of other organ-targeted PET and whole-body (WB) PET/CT systems available on the market or in clinical trials. NEMA tests have demonstrated an in-plane spatial resolution of 2.3 ± 0.1 mm, which is comparable to the best-in-class organ-targeted PET scanners. Additionally, the RPI system achieves a peak sensitivity of 3.5% and an average system sensitivity of 2.4%, surpassing the sensitivity of all available PET scanners. In terms of NECR, the peak NECR of 5,400 cps/MBq of the RPI is much larger than that of any WB or organ-targeted systems. The detectability of small objects was demonstrated using Micro hotspot phantom images, where micro hotspot phantom sources were visualized down to 1.35 mm diameter rods, simulating the detectability of very small objects and lesions.
The combination of the highest count rate capability, peak slice sensitivity, peak absolute slice sensitivity, and high spatial resolution of the RPI suggests superior overall efficiency in activity detection compared to any other PET technology. The first clinical evaluation of the RPI was for the detection of breast cancer with 18F-FDG in comparison with digital full-field mammography, magnetic resonance imaging (MRI), and WB PET images. Published results from clinical trials confirmed an improved resolution and detectability of small lesions compared to WB-PET and demonstrated the capability to identify false-negative X-ray findings and characterize false-positive MRI findings (for RPI, the false-positive rate was only 16% vs the 62% observed for MRI), even at up to a 10-fold dose reduction in comparison with standard FDG doses (i.e., at 37 MBq or 1 mCi) (9). Overall, if validated against standard of care PET/CT, a mobile, organ-based PET camera with high sensitivity detectors using lower injected tracer dose for the detection of neuritic beta-amyloid plaques could increase the availability of amyloid brain PET imaging in Canada and other jurisdictions and decrease associated costs. The purpose of this study is to evaluate the feasibility of using the Radialis PET Imager for the detection of amyloid plaque burden using PET amyloid tracer (18F-Florbetaben).
Hypothesis Phase I: Radialis PET Imaging (RPI) of the brain using amyloid PET tracer (18F-Florbetaben) is feasible.
Phase II: RPI can provide comparable diagnostic accuracy to the current standard of care 18F-Florbetaben PET.
Objectives Primary Objective To assess the feasibility of amyloid brain PET imaging using RPI To determine whether qualitative 18F-Florbetaben PET images obtained with RPI are diagnostically equivalent to those obtained with a standard-of-care PET scanner (PET/CT or PET/MR).
Secondary Objectives To determine whether lower doses of amyloid tracer can result in diagnostic RPI examinations.
To determine optimal dose and acquisition time for RPI.
To compare quantitative parameters:
Standardised Uptake Value ratio (SUVr) obtained by commercially available software (Hermes - BRASS):
SUVr= (SUV_VOI)/(SUV_(reference region) )
Where for a decay corrected administered activity concentration A_con^VOI the SUV in a given VOI will be calculated as follows:
SUV_VOI= (A_con^VOI)/(A_con^adm )
Mean SUVr and the voxel-wise standard deviation (SD) will be calculated for each assessed region in each subject. To assess tracer uptake agreement between images, the coefficient of variation (CV=SD/mean) will be calculated and compared between acquisition methods (10).
Signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) will be calculated for 8 standardized samples (VOIs) in 3 brain regions: cerebellum (2 samples), brain stem, cerebrum (4 samples), as follows:
SNR(VOI)= (Mean(VOI))/(SD(VOI))
CNR= (Mean(GM)-Mean(WM))/(SD(WM))
STUDY DESIGN 1 Overview A single-arm prospective trial with 2 phases
Phase I - Optimization of brain PET imaging technique and data reconstruction methods.
For this purpose, up to 10 patients will be recruited. Patients who are already scheduled for a clinical 18F-Florbetaben PET/CT or PET/MRI as per the current clinical indication in Ontario (PET scans and tracer are funded by the PET program, Cancer Care Ontario) will be screened and contacted for recruitment. The scheduled scans will be obtained and read clinically as per the standard of care.
After completing the clinical scan, consenting patients will be scanned on the RPI camera (within three hours). No additional tracer will be injected. No additional radiation exposure will be applied. The injection dose and time from injection to RPI will be recorded (for calculation of dose correction). Data will be stored and reconstructed from a 3D dataset in 3 planes (coronal, sagittal and axial). RPI attenuation correction will be atlas-based.
RPI imaging technique will be assessed for patient comfort and compliance, to ensure scanning fields result in complete coverage of the region of interest, to determine minimal and optimal scan time for maximizing image quality, and to validate the reconstruction and attenuation correction methods used. Imaging quality on original PET and the RPI acquisition will be assessed quantitatively: including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and coefficient of variation (CV) and qualitatively by independent review of 2 reviewers with image quality scored on a 4-point scale (4= excellent; 3 = good/ satisfactory; 2= suboptimal; 1 = nondiagnostic).
Finally, images will be reconstructed from list mode to simulate 10%, 25%, 50%, 75%, and 100% of the injected dose and assessed qualitatively and diagnostically. When all data has been obtained, the reconstructed datasets will be presented to 2 readers in random order. The minimal dose for which a diagnostic exam can be obtained will be determined.
Once the image acquisition technique is optimized and reconstruction of data is validated, the second phase of the study will commence.
Phase II - Validation of RPI against PET (PET/CT or PET/MR) for amyloid PET imaging
- Diagnostic performance For this purpose, 150 patients will be assessed using the finalized imaging protocol developed in Phase I. Each scan will be read as per standard protocol. In brief, each of the 4 assessed regions, the lateral temporal lobe, frontal cortex, posterior cingulate/ precuneus and parietal cortex, will be assessed and scored as per the Regional Cortical Tracer Uptake (RCTU) scoring system, as follows: score 1 - negative; score 2- moderate; score 3- significant tracer uptake. A scan with RCTU score of 1 in each of the 4 brain regions receives a β-amyloid Plaque Load (BAPL) score of 1 indicating no significant β-amyloid plaque load. A scan with RCTU score of 2 in at least one brain region and no score of 3 in any region will receive a BAPL score of 2, indicating moderate β-amyloid plaque load. Finally, a scan with RCTU score of 3 in at least one of the brain regions will receive a BAPL score of 3, indicating significant β-amyloid plaque load. The same criteria will be used to assess each dataset - PET and RPI. To minimize bias, the scans will be read in batches of 5 patients, with the PET and RPI datasets shuffled and randomly presented to the reviewer. Each scan will be interpreted independently by 2 reviewers, with a final consensus read on each imaging modality (PET and RPI), if needed. If no consensus is achieved, a third arbitrator read will be obtained from a further independent reviewer. The concordance (inter-modality agreement) between PET and RPI on a regional level and overall patient level will be assessed.
- Feasibility of Dose Reduction To determine the clinical feasibility of using reduced-dose RPI examinations, the minimal injected dose, as determined by phase I, will be assessed independently quantitatively and qualitatively (RCTU = regional cortical tracer uptake; BAPL = brain β-amyloid plaque load where BAPL 1 = negative, BAPL 2 \& 3 = positive) and compared to the full-dose exam.
2 Sample size Phase I: 10 patients Phase II: 150 patients
Noninferiority sample size justification for matched samples:
For alpha =0.05; power (1-beta) = 0.95; assuming the technical success of 98.5% for each modality (PET and RPI) for a noninferiority limit of 5%, there would need to be 128 patients assessed with each test. Allowing for approximately 15% incomplete datasets (patients not completing imaging and/or nondiagnostic reference standard), sample size = 150 patients.
3 STUDY ENROLLMENT AND WITHDRAWAL 3.1 Inclusion Criteria 3.1.1. Age ≥18 years 3.1.2. Patients with cognitive impairment undergoing the standard of care brain 18F-Florbetaben PET imaging.
3.1.3. Patients who can remain still for an additional scan of approximately 30-45 minutes.
3.2 Exclusion Criteria 3.2.1. Inability to provide informed consent. 3.2.2. Contraindication for PET examination as per institutional safety guidelines, including but not limited to pregnancy or inability to remain still for PET examination.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Single arm cohort study
| Arm | Type | Receives |
|---|---|---|
| Single arm, observational | Other | Device: PETSingle arm, observational |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Age ≥18 years
- Patients with cognitive impairment undergoing the standard of care brain 18F-Florbetaben PET imaging.
- Patients who can remain still for an additional scan of approximately 30-45 minutes.
- -
Key exclusion criteria (2 listed)
- 1. Inability to provide informed consent. 2. Contraindication for PET examination as per institutional safety guidelines, including but not limited to pregnancy or inability to remain still for PET examination.
- -
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| PETFeasibility assessment of using the Radialis PET Imager for the detection of amyloid plaque burden using PET amyloid tracer. | Device | Single arm, observational |
Primary outcome
feasibility of amyloid brain PET imaging using RPI
Time frame: 2 years
Number of diagnostic exams performed with RPI compared to standard PET.
3 secondary outcomes
Qualitative assessment
Time frame: 2 years
Tracer Dose
Time frame: 2 years
Acquisition Time
Time frame: 2 years
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 3 Feb 2026.
- Individual participant dataSharing planned: Undecided
Related trials for Cognitive Impairment
Recruiting
Early Motor-Cognitive Integrative Training on Cognitive and Motor Performance in Patients With Aneurysmal Subarachnoid Hemorrhage
Subarachnoid Aneurysm Hemorrhage
Recruiting
HEARS-NPS: Addressing Hearing Loss as a Common Unmet Contributor of Neuropsychiatric Symptoms
Alzheimer Disease, Dementia
RecruitingObservational study
Locus Coeruleus and CCHS (Congenital Central Hypoventilation Syndrome)
Ondine Syndrome (Congenital Central Hypoventilation Syndrome)
RecruitingPhase 1
PET Imaging of Phosphodiesterase-4 (PDE4) in Volunteers With Alzheimer Disease (AD) or Mild Cognitive Impairment (MCI)
Alzheimer s Disease, Mild Cognitive Impairment
RecruitingObservational study
Community-based Screening for Alzheimer's Disease
Alzheimer's Disease(AD), Mild Cognitive Impairment (MCI)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing PET in people with Cognitive Impairment, run by University Health Network, Toronto at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 3 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Ur Metser (416-946-4501 ext. 4394, ur.metser@uhn.ca), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
feasibility of amyloid brain PET imaging using RPI (time frame: 2 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Feb 2026.