Pediatric Positive End Expiratory Pressure (PEEP) Titration Using Electrical Impedence Tomography (EIT)

A study testing Electrical Impedance Tomography positive end-expiratory pressure titration in people with Pediatric Acute Respiratory Distress Syndrome, run by Children's Hospital Los Angeles at 1 site in United States.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this clinical trial is to perform a PEEP titration protocol and use EIT to identify the optimal PEEP at which lung overdistention and collapse are most effectively balanced. Read more about this study

Who is it for?
Ages 0 to 18 years
What is being tested?
Electrical Impedance Tomography positive end-expiratory pressure titration
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteUnited States
Study dates
10 Dec 2024to 1 Jul 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 0 to 18 years
  • All sexes
  • No healthy volunteers
  • Child, Adult

Who may be able to join

  • Any person who is less than 18 years of age
  • is on invasive mechanical ventilation
  • is not spontaneously breathing
  • meets PARDS criteria

Who cannot join

  • Contraindication to the use of EIT
  • Hemodynamic instability
  • Contraindications to hypercapnia
  • patients with uncuffed endotracheal or tracheostomy tubes
  • diagnosis of pneumothorax or bronchopleural fistula
  • non-conventional ventilation
Show all 11Show fewer
  • any patient on extra-corporeal membrane oxygenation (ECMO) support
  • less than 1 week post-operatively from cardiac surgery
  • the following cardiac diagnoses: Glenn or Fontan physiology, significant right to left shunt
  • Corrected Gestational Age < 37 weeks
  • pregnancy

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Hayden Leeds, MD contact

3233617939

hleeds@chla.usc.edu

Anoopindar Bhalla, MD contact

323-361-7939

abhalla@chla.usc.edu

United States1 site, 1 recruiting
  • Children's Hospital Los Angeles

    Los Angeles, California, 90027

    Hayden Leeds

    Recruiting

Other trials in United States

About this study

Official title: Assessing Optimal Positive End-expiratory Pressure (PEEP) Using Electrical Impedance Tomography (EIT) During a PEEP Titration Protocol in Mechanically Ventilated Children with Pediatric Acute Respiratory Distress Syndrome (PARDS)

The goal of this clinical trial is to perform a PEEP titration protocol and use EIT to identify the optimal PEEP at which lung overdistention and collapse are most effectively balanced. The primary and secondary aims of the study are as follows:

Identify the difference between the optimal PEEP recommended by EIT metrics and the current guideline recommended approach to identifying optimal PEEP in PARDS. There will be a statistically significant difference in the recommended optimal PEEP identified using the EIT PEEP titration tool and that of the PEEP/FiO2 grid recommendations.

Read more

Determine the difference in physiologic metrics between EIT optimal PEEP and the PEEP/FiO2 recommended PEEP.

Participants will undergoing EIT monitoring while being subjected to PEEP titration protocol.

Being tested
Electrical Impedance Tomography positive end-expiratory pressure titration
Keywords
positive end-expiratory pressure, Electrical Impedance Tomography, respiratory distress
Medical subject headings
Dyspnea

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electrical Impedance Tomography positive end-expiratory pressure titrationDevice

    A PEEP titration will occur for the patient with the PEEP increased by 2 cm H2O every 2 minutes until a maximum PEEP of 20 or three steps (+ 6 cm H2O) above the set clinical PEEP. The PEEP will then be decreased by 2 cmH2O every 2 minutes until a minimum PEEP of 6 cmH2O or three steps (- 6 cm H2O) below their clinical PEEP.

Study groups in NCT06684119
Study groupRoleWhat they receive
Electrical Impedance Tomography positive end-expiratory pressureExperimentalPatients will be monitored using Electrical Impedance Tomography and the positive end-expiratory pressure titration tool as their positive end-expiratory pressure is adjusted according to a step wise positive end-expiratory pressure titration protocol.
Receives: Device: Electrical Impedance Tomography positive end-expiratory pressure titration

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The absolute difference between the electrical impedence tomography (EIT) recommended PEEP and the PEEP recommended by the PEEP/fraction of inspired oxygen (FiO2) grid.

    Collected using electrical impedence tomography (EIT). The EIT device provides the percentages of alveolar overdistention and collapse at each PEEP level. The best PEEP by EIT is defined as the PEEP level above the intersection of curves representing relative alveolar overdistention and collapse.

    Measured: Day 1

Secondary outcomes (7)
  1. Lung recruitability, as measured by electrical impedence tomography, and its association with difference in optimal PEEP recommended by electrical impedence tomography versus the PEEP/FiO2 grid

    Recruitability will be defined as the absolute reduction in the percentage of collapse when comparing the highest and lowest PEEP achieved, as measured by electrical impedence tomography.

    Measured: Day 1

  2. Difference in systolic impendence, as a surrogate for cardiac output, using electrical impedence tomography at various PEEP levels

    Using the electrical impedence tomography pulsatility filter/tool, a difference in systolic impendence, attributed to the cardiac cycle, can be calculated. This will be used as a surrogate for stroke volume and will be compared across PEEP levels.

    Measured: Day 1

  3. Change in static compliance across different PEEP levels during a PEEP titration

    Static compliance is defined as the change in volume divided by the change in pressure during an inspiratory hold (when airflow is zero). It reflects the elastic properties of the lung and chest wall.

    Measured: Day 1

  4. Change in driving pressure across different PEEP levels during a PEEP titration

    Driving pressure is the difference between the plateau pressure (the pressure measured during an inspiratory hold, when airflow is zero) and the positive end-expiratory pressure (PEEP). It represents the pressure that actually distends the alveoli during mechanical ventilation.

    Measured: Day 1

  5. Change in plateau pressure across different PEEP levels during a PEEP titration

    Plateau pressure is the pressure measured during an inspiratory hold maneuver, which occurs when the ventilator temporarily halts airflow at the end of the inspiratory phase. This allows the pressure in the alveoli to stabilize, providing a true reflection of the pressure needed to distend the lungs, without the effects of airflow resistance.

    Measured: Day 1

  6. Change in dead space, as measured by volumetric capnography, across different PEEP levels during a PEEP titration

    For patients who consent to the optional placement of a volumetric capnography device, dead space will be continuously measured using volumetric capnography by measuring the volume of carbon dioxide (CO2) exhaled with each breath (VeCO2) and calculating the CO2 ventilatory equivalent (minute ventilation/VCO2). Airway dead space can be obtained with each breath.

    Measured: Day 1

  7. Change in transplural pressure, as measured by esophageal manometry, across different PEEP levels during a PEEP titration

    For patients who consent to the optional component of having an esophageal balloon catheter placed, esophageal manometry will be used to measure transplural pressure. The difference between the pressure in the alveoli (intrapulmonary pressure) and the pressure in the pleural space (intrapleural pressure). It reflects the pressure required to expand the lungs and is crucial for understanding lung mechanics. This will be obtained using esophageal manometry with inspiratory and expiratory holds at each PEEP titration level.

    Measured: Day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Nov 2024
  2. Study start10 Dec 2024
  3. Primary completion1 Jan 2027 (estimated)
  4. Study completion1 Jul 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06684119
Sponsor's protocol ID
CHLA-24-00295
Status last verified
Dec 2024
First submitted
8 Nov 2024
Last updated
7 Feb 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Electrical Impedance Tomography positive end-expiratory pressure titration in people with Pediatric Acute Respiratory Distress Syndrome, run by Children's Hospital Los Angeles at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 7 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Hayden Leeds, MD (3233617939, hleeds@chla.usc.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The absolute difference between the electrical impedence tomography (EIT) recommended PEEP and the PEEP recommended by the PEEP/fraction of inspired oxygen (FiO2) grid. (time frame: Day 1). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Feb 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in