Airway ObstructionNCT06609499
Evaluation of Airway Adjuncts for Intubation in Entrapped Patients With Difficult Airway Access
A study testing Flexible-tip Bougie and Gum-elastic Bougie in people with Airway Obstruction, run by Uniwersytet Radomski im. Kazimierza Pułaskiego at 1 site in Poland.
Trial summary
The aim of this clinical trial is to evaluate two airway adjuncts for intubation in a simulated condition of an entrapped trauma patient with simultaneous cervical spine immobilisation. All the studied devices are evaluated by fully-qualified and experienced paramedics (both male and female). Read more about this study
- Who is it for?
- Ages 25 to 55 years
- Conditions the study is for
- Airway Obstruction
- What is being tested?
- Flexible-tip Bougie and Gum-elastic Bougie
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 50 participants
- Where
- 1 sitePoland
- Study dates
- 15 Mar 2025to 31 May 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 25 to 55 years
- All sexes
- No healthy volunteers
- Adult
Who may be able to join
- fully-qualified paramedics
- at least four years of practice after finishing paramedic training
- active (working) paramedics
Who cannot join
- paramedics in training
- retired paramedics
- lack of written informed consent
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Standard Gum Elastic Bougie Versus Flexible-tip Bougie: Evaluation of Airway Adjuncts for Intubation in Entrapped Patients With Difficult Airway Access - a Randomised, Controlled Trial
The aim of this clinical trial is to evaluate two airway adjuncts for intubation in a simulated condition of an entrapped trauma patient with simultaneous cervical spine immobilisation. All the studied devices are evaluated by fully-qualified and experienced paramedics (both male and female). The main questions it aims to answer are:
Which device requires the shortest time required to achieve a successful intubation and ventilation? What is the first attempt success rate of the studied devices? Which device is the easiest to use and the most user-friendly? Study participants will evaluate two different airway adjuncts for intubation in a restricted access to the entrapped trauma patient's airway. The maximum number of insertion attempts is limited to three per device.
Read the detailed description
A written informed consent will be obtained from all study participants. Only qualified paramedics will participate in the study. Their experience varies between four and eight years of practice after completion of paramedic training. All study participants had never used the flexible-tip bougie but had a routine intubation experience with the standard gum elastic bougie (more than 40 intubations previously performed).
A 10-minute lecture will be delivered before the start of the study. It will explain how to use the STIG. Following the lecture all participants will be able to familiarise themselves with the equipment and practice for 30 minutes. A skill station will be set up containing an intubation manikin AT Kelly Torso (Laerdal Medical AS, Stavanger, Norway). A reduced movement of the cervical spine will be achieved by application of a Patriot® cervical collar (Össur hf., Reykjavik, Iceland). After completion of the initial practice the intubation manikin with the cervical collar on wall be placed on and secured to the driver's seat of a FIAT Bravo car (FIAT S.p.A., Turin, Italy). The car will then be positioned on its left side and secured in place by firemen from a local fire brigade. The access to the manikin will only allowed from the front i.e. through the opening created after removal of the windscreen. A single digit number will be allocated to each of the two studied devices i.e. 1 for the flexible-tip bougie and 2 for the standard gum elastic bougie (SUMI Sp. z o.o., Sp. K., Sulejówek, Poland). Each study participant will be asked to randomly give a number (either 1 or 2) and will then be given the corresponding tracheal tube introducer to use. The maximum number of intubation attempts is limited to three per device. The time required to intubate and successfully ventilate (Ti) the manikin will be recorded. It will be measured using a stopwatch of a mobile phone (Apple Inc., Cupertino, California, USA). Efficacy of intubation and the ease of use by the operator will also be assessed. The latter will be measured using an 11-point numerical rating scale (NRS) where 0 corresponds to a very difficult to use device and 10 indicates an easy to use and user-friendly introducer. Size 7.5 tracheal tube (SUMI Sp. z o.o., Sp. K., Sulejówek, Poland) will be utilised in the study. A manual resuscitator (Ambu A/S, Ballerup, Denmark) will be used for ventilation and will be readily available to the paramedics. The standard Macintosh-blade laryngoscope (New Waseem Trading Co., Sialkot, Pakistan) will be utilised for direct laryngoscopy. Size three blade will be used. The study participants will perform all intubations with each of the two tracheal tube introducers. A failed intubation will be defined as an attempt during which the trachea cannot be intubated or an attempt that lasts longer than 120 seconds. Only those who failed to intubate will be allowed another attempt. All the obtained data will be analysed using Microsoft Office Excel 2021 spreadsheet (Microsoft Corporation, Redmond, WA, USA) and GraphPad Prism (GraphPad Software, Boston, MA, USA). The Kolmogorov-Smirnov test will be utilised to determine whether the analysed variables matches the characteristics of a normal distribution. A paired Student t-test and the Wilcoxon signed-rank test will be used for data analysis. Based on our previous unpublished pilot study and assuming that the overall success rate of intubation in patients with a difficult airway will be 90% (α =0.05, 2-sided, β =0.1), 46 participants are required. The final adjusted sample size, allowing a drop-out rate of about 10%, will be 50 and this is the final number of participants enrolled into the study. A p value of less than 0.05 (p<0.05) is considered statistically significant.
- Conditions
- Airway Obstruction
- Being tested
- Flexible-tip Bougie, Gum-elastic Bougie
- Keywords
- tracheal intubation, trauma, entrapped patients,, introducer, flexible-tip bougie
- Medical subject headings
- Airway Obstruction, Wounds and Injuries
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Flexible-tip BougieDevice
The device is used for intubation and then the manikin is ventilated
Gum-elastic BougieDevice
The device is used for intubation and then the manikin is ventilated
| Study group | Role | What they receive |
|---|---|---|
| Flexible-tip Bougie Group | Experimental | Paramedics using the flexible-tip bougie (the STIG) Receives: Device: Flexible-tip Bougie |
| Gum-elastic bougie Group | Active comparator | Paramedics using the gum-elastic bougie Receives: Device: Gum-elastic Bougie |
What is being measured
The primary outcome is the main question the study is designed to answer.
Successful intubation time
The time required to intubate and successfully ventilate the manikin
Measured: From the date of randomization until the date of documented completion, assessed up to four months
Secondary outcomes (2)
First attempt success rate of intubation
The efficacy of evaluated airway adjuncts
Measured: From the date of randomization until the date of documented completion, assessed up to four months
The ease of use and user-friendliness
Device evaluation using the numerical rating scale (NRS). It is an 11-point scale where 0 corresponds to a very difficult to use device and 10 indicates an easy to use and user-friendly device.
Measured: From the date of randomization until the date of documented completion, assessed up to four months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted24 Sep 2024
- Study start15 Mar 2025
- Primary completion1 May 2025
- Study completion31 May 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Airway ObstructionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 50 participants (actual)
Sponsor and investigators
- Lead sponsor
- Uniwersytet Radomski im. Kazimierza Pułaskiego
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Dawid J Aleksandrowicz, PhD, Principal investigator, University of Radom
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06609499
- Sponsor's protocol ID
- 04/2024
- Status last verified
- Aug 2025
- First submitted
- 20 Sep 2024
- Last updated
- 5 Sep 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 5 Sep 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Standard Gum Elastic Bougie Versus Flexible-tip Bougie: Evaluation of Airway Adjuncts for Intubation in Entrapped Patients With Difficult Airway Access - a Randomised, Controlled Trial
- ClinicalTrials.gov ID
- NCT06609499
- Acronym / sponsor ID
- 04/2024
- Conditions
- Airway Obstruction
- Keywords
- tracheal intubation, trauma, entrapped patients,, introducer, flexible-tip bougie
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 50 participants (actual)
- Lead sponsor
- Uniwersytet Radomski im. Kazimierza PułaskiegoUniversity, hospital or other
- Study start
- 15 Mar 2025 (actual)
- Primary completion
- 1 May 2025 (actual)
- Study completion
- 31 May 2025 (actual)
- First posted
- 24 Sep 2024 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of this clinical trial is to evaluate two airway adjuncts for intubation in a simulated condition of an entrapped trauma patient with simultaneous cervical spine immobilisation. All the studied devices are evaluated by fully-qualified and experienced paramedics (both male and female). The main questions it aims to answer are:
Which device requires the shortest time required to achieve a successful intubation and ventilation? What is the first attempt success rate of the studied devices? Which device is the easiest to use and the most user-friendly? Study participants will evaluate two different airway adjuncts for intubation in a restricted access to the entrapped trauma patient's airway. The maximum number of insertion attempts is limited to three per device.
Detailed description
A written informed consent will be obtained from all study participants. Only qualified paramedics will participate in the study. Their experience varies between four and eight years of practice after completion of paramedic training. All study participants had never used the flexible-tip bougie but had a routine intubation experience with the standard gum elastic bougie (more than 40 intubations previously performed).
A 10-minute lecture will be delivered before the start of the study. It will explain how to use the STIG. Following the lecture all participants will be able to familiarise themselves with the equipment and practice for 30 minutes. A skill station will be set up containing an intubation manikin AT Kelly Torso (Laerdal Medical AS, Stavanger, Norway). A reduced movement of the cervical spine will be achieved by application of a Patriot® cervical collar (Össur hf., Reykjavik, Iceland). After completion of the initial practice the intubation manikin with the cervical collar on wall be placed on and secured to the driver's seat of a FIAT Bravo car (FIAT S.p.A., Turin, Italy). The car will then be positioned on its left side and secured in place by firemen from a local fire brigade. The access to the manikin will only allowed from the front i.e. through the opening created after removal of the windscreen. A single digit number will be allocated to each of the two studied devices i.e. 1 for the flexible-tip bougie and 2 for the standard gum elastic bougie (SUMI Sp. z o.o., Sp. K., Sulejówek, Poland). Each study participant will be asked to randomly give a number (either 1 or 2) and will then be given the corresponding tracheal tube introducer to use. The maximum number of intubation attempts is limited to three per device. The time required to intubate and successfully ventilate (Ti) the manikin will be recorded. It will be measured using a stopwatch of a mobile phone (Apple Inc., Cupertino, California, USA). Efficacy of intubation and the ease of use by the operator will also be assessed. The latter will be measured using an 11-point numerical rating scale (NRS) where 0 corresponds to a very difficult to use device and 10 indicates an easy to use and user-friendly introducer. Size 7.5 tracheal tube (SUMI Sp. z o.o., Sp. K., Sulejówek, Poland) will be utilised in the study. A manual resuscitator (Ambu A/S, Ballerup, Denmark) will be used for ventilation and will be readily available to the paramedics. The standard Macintosh-blade laryngoscope (New Waseem Trading Co., Sialkot, Pakistan) will be utilised for direct laryngoscopy. Size three blade will be used. The study participants will perform all intubations with each of the two tracheal tube introducers. A failed intubation will be defined as an attempt during which the trachea cannot be intubated or an attempt that lasts longer than 120 seconds. Only those who failed to intubate will be allowed another attempt. All the obtained data will be analysed using Microsoft Office Excel 2021 spreadsheet (Microsoft Corporation, Redmond, WA, USA) and GraphPad Prism (GraphPad Software, Boston, MA, USA). The Kolmogorov-Smirnov test will be utilised to determine whether the analysed variables matches the characteristics of a normal distribution. A paired Student t-test and the Wilcoxon signed-rank test will be used for data analysis. Based on our previous unpublished pilot study and assuming that the overall success rate of intubation in patients with a difficult airway will be 90% (α =0.05, 2-sided, β =0.1), 46 participants are required. The final adjusted sample size, allowing a drop-out rate of about 10%, will be 50 and this is the final number of participants enrolled into the study. A p value of less than 0.05 (p<0.05) is considered statistically significant.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Flexible-tip Bougie Group | Experimental | Device: Flexible-tip BougieParamedics using the flexible-tip bougie (the STIG) |
| Gum-elastic bougie Group | Active comparator | Device: Gum-elastic BougieParamedics using the gum-elastic bougie |
Who may qualify
- Ages
- 25 to 55 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (3 listed)
- fully-qualified paramedics
- at least four years of practice after finishing paramedic training
- active (working) paramedics
Key exclusion criteria (3 listed)
- paramedics in training
- retired paramedics
- lack of written informed consent
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Flexible-tip BougieThe device is used for intubation and then the manikin is ventilated | Device | Flexible-tip Bougie Group |
| Gum-elastic BougieThe device is used for intubation and then the manikin is ventilated | Device | Gum-elastic bougie Group |
Primary outcome
Successful intubation time
Time frame: From the date of randomization until the date of documented completion, assessed up to four months
The time required to intubate and successfully ventilate the manikin
2 secondary outcomes
First attempt success rate of intubation
Time frame: From the date of randomization until the date of documented completion, assessed up to four months
The ease of use and user-friendliness
Time frame: From the date of randomization until the date of documented completion, assessed up to four months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Sep 2025.
- Individual participant dataSharing planned: No
Related trials for Airway Obstruction
RecruitingPhase 2
A Study to Learn About the Study Medicine Called PF-07275315 in People With Moderate-To-Severe Asthma
Asthma
Active, not recruitingObservational study
A Prospective Study Comparing VivAer to Alternative Surgical Procedures to Treat Nasal Airway Obstruction in Patients With Nasal Valve Dysfunction.
Nasal Airway Obstruction
Recruiting
Measuring Nasal Airway Changes After VivAer Treatment Using AI Analysis
Nasal Airway Obstruction
Enrolling by invitationObservational study
Difficult Airway Management in Oncology: An International Delphi Consensus Study (DAMO)
Neoplasms, Airway Obstruction Upper
RecruitingObservational study
Evaluation of Foreign Body Airway Obstruction Interventions Among Young Children: A Prospective Cohort Study
Choking
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Dawid J Aleksandrowicz, PhD principal investigator
University of Radom
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Flexible-tip Bougie and Gum-elastic Bougie in people with Airway Obstruction, run by Uniwersytet Radomski im. Kazimierza Pułaskiego at 1 site in Poland.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 5 Sep 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Poland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Successful intubation time (time frame: From the date of randomization until the date of documented completion, assessed up to four months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Sep 2025; AzTrials last refreshed its copy on 8 Nov 2026.