AzTrials
AzTrials

Implant PlacementNCT06571968

Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible

A study testing fully guided stent and semiguided stent in people with Implant Placement, run by Mansoura University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Thirty-six completely edentulous healthy patients received four mandibular implants and were randomly divided into the following groups: (A) The implants were installed by fully guided stereolithographic stent (n = 18), and (B) The implants were installed by semi-guided stereolithographic stent. (n = 18). Read more about this study

Who is it for?
Ages 58 to 68 yearsHealthy volunteers can take part
Conditions the study is for
Implant Placement
What is being tested?
fully guided stent and semiguided stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
36 participants
Where
1 siteEgypt
Study dates
14 May 2023to 2 Feb 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 58 to 68 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • All patient wearing maxillary conventional denture.
  • All patients had temporary mandibular overdenture supported by vertically inserted 4-implant at least six months ago.
  • They were healthy, free from any systemic diseases relating to bone resorption such as uncontrolled diabetics or osteoporosis. This was achieved through medical history and clinical examination by physician.
  • All patients are of angel's class I maxillo-mandibular relationships.

Who cannot join

  • Patients had head and neck radiotherapy, patients with bleeding disorders or hepatic patients.
  • Patients with metabolic disorders as diabetes mellitus, osteoporosis and hepatic disorders that might affect osseointegration.
  • Long term immunosuppress and corticosteroid drug therapy.
  • Patient with abnormal habits as clenching and bruxism.
  • Smoking patient.
  • Patient with problems in TMJ

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Marwa Aboelez

    Al Mansurah

Other trials in Egypt

About this study

Official title: Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible by Using Fully Versus Semi Guided Prototyped Surgical Stent

Thirty-six completely edentulous healthy patients received four mandibular implants and were randomly divided into the following groups: (A) The implants were installed by fully guided stereolithographic stent (n = 18), and (B) The implants were installed by semi-guided stereolithographic stent. (n = 18). The accuracy analysis was performed by one experienced process engineer (DB). Cone beam computed tomography was performed before and after the surgical procedure to plan the virtual implant position and fabricate the surgical guide, as well as to determine implant position deviations. Both CBCT scans were superimposed, and the software compared preoperative linear and angular virtual measurements of planned implants with real measurements of the placed implants.

Read the detailed description

Objectives: Current study aimed to assess the accuracy of fully- guided implant placement in completely lower edentulous patients compared to the semi-guided protocol.

Materials and Methods: Thirty-six completely edentulous healthy patients received four mandibular implants and were randomly divided into the following groups: (A) The implants were installed by fully guided stereolithographic stent (n = 18), and (B) The implants were installed by semi-guided stereolithographic stent. (n = 18). The accuracy analysis was performed by one experienced process engineer (DB). Cone beam computed tomography was performed before and after the surgical procedure to plan the virtual implant position and fabricate the surgical guide, as well as to determine implant position deviations. Both CBCT scans were superimposed, and the software compared preoperative linear and angular virtual measurements of planned implants with real measurements of the placed implants. Measurements and analysis of results were performed by means of a software tool used during virtual planning (P3Dental; Protótipos).

Being tested
fully guided stent, semiguided stent
Keywords
Fully-guided surgical stent, semi-guided surgical stent, accuracy analysis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • fully guided stentDevice

    All surgical procedures with drills were done through the stent., the implant was picked up from the implant holder and then installed, still with the surgical guide in situ, by using the ratchet and ratchet connector at a motor speed of 20 rpm, followed by cover screw placement without the need for sutures.

  • semiguided stentDevice

    The first osteotomy was performed with the surgical guide in situ using a 1.95 mm pilot-drill. Successive color coded implant drills were used to prepare implant osteotomies. When using each twist drill, a removable sleeve having a diameter to coincide with the drill and inserted into the sleeve of the surgical guide.

    The stereo lithographic guide template was removed and the receptor sites were irrigated with saline solution then the final drill of the implant system 3.5 mm diameter was used to finalize the osteotomy. The implant was gripped with the placement aid, released from the implant holder by 1/4 turn and manually inserted into the prepared implant site using a finger placement tool or hand ratchet. A torque of 45 N cm should not be exceeded during insertion procedure and cover screws were screwed over it.

Study groups in NCT06571968
Study groupRoleWhat they receive
fully guided surgical techniqueOtherThe guides were designed with metal sleeves for guided drilling and guided implant placement and additional guide sleeves for the stabilization of the template by fixation screws.The implant width and length were selected for each patient according to previous 3d cone beam, and the drills of this kit were 11 mm longer than conventional drills. The surgery was performed without flap elevation. The guide was seated and fixed by means of 2-mm cortical screws in the buccal region after using of the corresponding drills.
Receives: Device: fully guided stent
semi guided surgical techniqueOtherThe guides were designed with metal sleeves for guided drilling and guided implant placement and additional guide sleeves for the stabilization of the template by fixation screws.The implant width and length were selected for each patient according to previous 3d cone beam, and the drills of this kit were 11 mm longer than conventional drills.The surgery was performed without flap elevation. The stent was removed before the final drilling
Receives: Device: semiguided stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Radio graphic evaluation (Angular deviation)

    For both groups, postoperative CBCT scan was performed after implant placement. The same parameters of preoperative CBCT were followed according to the patient's position, image acquisition, and use of the same apparatus. This scan was performed with the same dental prosthesis as that used for the initial preoperative CBCT scanning, equipped with the gutta percha references, for superimposition of the images. The previously fabricated occlusal registration was used to align the prosthesis. Both CBCT scans were superimposed, and the software compared preoperative horizontal (Mesiodistal and buccolingual), vertical and angular virtual measurements of planned implants with real measurements of the placed implants.

    Measured: one year

Secondary outcomes (1)
  1. Radio graphic evaluation (linear deviation)

    For both groups, postoperative CBCT scan was performed after implant placement. The same parameters of preoperative CBCT were followed according to the patient's position, image acquisition, and use of the same apparatus. This scan was performed with the same dental prosthesis as that used for the initial preoperative CBCT scanning, equipped with the gutta percha references, for superimposition of the images. The previously fabricated occlusal registration was used to align the prosthesis. Both CBCT scans were superimposed, and the software compared preoperative horizontal (Mesiodistal and buccolingual) measurements of planned implants with real measurements of the placed implants.

    Measured: one year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Aug 2024
  2. Study start14 May 2023
  3. Primary completion3 Jan 2024
  4. Study completion2 Feb 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Model description
randomized controlled clinical trial
Masking
Single blind
Who is masked
Investigator
Enrolment
36 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06571968
Sponsor's protocol ID
M05010322
Status last verified
Jul 2024
First submitted
8 Aug 2024
Last updated
1 May 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: statistical analysis plan

Publications

  • Malpartida-Carrillo V, Tinedo-Lopez PL, Ortiz-Culca F, Guerrero ME, Amaya-Pajares SP. Techniques for retrievability and for registering screw access holes in cement-retained implant-supported prostheses: A scoping review of the literature. J Prosthet Dent. 2020 Mar;123(3):427-433. doi: 10.1016/j.prosdent.2019.03.011. Epub 2019 Jul 12.

    PubMed 31307803

Questions about this trial

What is this clinical trial studying?

A study testing fully guided stent and semiguided stent in people with Implant Placement, run by Mansoura University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 May 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Radio graphic evaluation (Angular deviation) (time frame: one year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06571968, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 May 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in