AzTrials
AzTrials

Breast CancerEMBLEDDA-MMGNCT06428799

Evaluation of Carebot AI MMG Medical Device for Breast Lesion Detection and Density Assessment

An observational study of Breast Cancer and Breast Tumor Benign, run by Carebot s.r.o. at 3 sites in Czechia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Comparison of accuracy of clinician and DLAD image evaluation (Carebot AI MMG v2.2) 1. Comparison of the Accuracy of Density Assessment by Clinician and DLAD (DENS) 2. Comparison of Accuracy of Lesion Assessment by Clinician and DLAD (MASS, CLASS) Read more about this study

Who is it for?
Ages 18 years and older, women only
Conditions the study is for
Breast Cancer, Breast Tumor Benign
What is being tested?
Carebot AI MMG
Type of treatment
Medical device
How many people
122 participants
Where
3 sitesCzechia
Study dates
14 Jan 2022to 24 Apr 2024
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Women only
  • Adult, Older adult

Study population: A total of 122 mammography studies (488 images, the so-called "test data") were obtained from the reference sites for the evaluation by radiologists and the Carebot AI MMG v2.2. The target sites used different mammography X-ray machines: Site 1 and Site 2 used the Senographe Essential mammography machine from GE HealthCare to image patients, and Site 3 used the Selenia Dimensions mammography machine from Hologic and the MAMMOMAT Revelation mammography machine from Siemens Healthineers.

Who may be able to join

  • The medical device is intended for use in women over 18 years of age who are indicated for screening mammography using digital mammography.

Who cannot join

  • The medical device cannot be used in patients with breast implants.
  • The medical device cannot be used in male breast examination.
  • The medical device cannot be used in patients under 18 years of age.

Trial locations and contacts

3 sites in 1 country.

Czechia3 sites
  • EUC Mamocentrum Brno

    Brno, 60200

  • Masaryk Memorial Cancer Institute

    Brno, 60200

  • Hospital Šumperk

    Šumperk, 78701

Other trials in Czechia

About this study

Official title: Evaluation of Carebot AI MMG Medical Device for Detection and Radiographic Assessment of Breast Lesions and Quantitative Analysis of Breast Density: A Multicentric, Multi-Reader Study

Comparison of accuracy of clinician and DLAD image evaluation (Carebot AI MMG v2.2)

  1. Comparison of the Accuracy of Density Assessment by Clinician and DLAD (DENS)
  2. Comparison of Accuracy of Lesion Assessment by Clinician and DLAD (MASS, CLASS)
Read the detailed description

The mammography studies were acquired from three independent sites: Site 1 (EUC Mamocentrum Brno) and Site 2 (Hospital Šumperk, a.s.) specialise in routine screening mammography, and Site 3 (Masaryk Memorial Cancer Institute) is a comprehensive oncology facility primarily dedicated to diagnostic mammography, i.e. performing additional examinations in case of a suspicious finding (recall).

The ground truth was obtained by consensus of two board-certified radiologists with expertise in radiology and diagnostic methods, and 13 and 27 years of experience with mammography image interpretation, respectively.

For comparative analysis, a team of five independent radiologists with clinical experience in interpreting mammography images was established. Three of the clinicians were junior (2, 2, and 4 years of experience, respectively) without board-certification; two physicians were senior (7 and 8 years of experience, respectively), board-certified.

Being tested
Carebot AI MMG
Medical subject headings
Breast Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Carebot AI MMGDevice

    Carebot AI MMG is a software solution that utilizes artificial intelligence methods, specifically deep learning and computer vision algorithms, to evaluate and localize suspicious regions of potential lesions during the interpretation of digital breast x-rays as part of standard mammography screening procedures. The Carebot AI MMG medical device is not intended for use in diagnostic mammography. The Carebot AI MMG is intended for use in women over the age of 18.

    The predictive outputs of the Carebot AI MMG medical device are intended to aid decision-making in screening clinical practice, always in conjunction with other relevant patient information and based on the professional judgment of the examining clinician. The Carebot AI MMG is specifically designed to provide a supporting layer of analysis that helps in evaluating or prioritizing mammography images with additional patient information and the professional judgment of the examining physician.

Study groups in NCT06428799
Study groupRoleWhat they receive
Retrospective collection of DICOM patient files for Site 1A total of 60 mammographic studies were retrospectively collected from Site 1 (EUC Mamocentrum Brno). The acquisition of mammography studies from Site 1 was enabled by the contract for the transfer of mammography images for medical research purposes, signed on 14 January 2022.
Receives: Device: Carebot AI MMG
Retrospective collection of DICOM patient files for Site 2A total of 28 mammographic studies were retrospectively collected from Site 2 (Hospital Šumperk, a.s.). The acquisition of mammography studies from Institution 2 was enabled by the contract for the transfer of mammography images for medical research purposes, signed on 31 January 2023.
Receives: Device: Carebot AI MMG
Retrospective collection of DICOM patient files for Site 3A total of 34 mammographic studies were retrospectively collected from Site 3 (Masaryk Memorial Cancer Institute). The acquisition of mammography studies from Institution 3 was enabled by the amendment to the contract for the transfer of X-ray images for medical research purposes, signed on 21 February 2023, which follows the contract for the transfer of X-ray images for medical research purposes, signed on 3 January 2022.
Receives: Device: Carebot AI MMG

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Performance Test

    A multicenter, multi-reader, retrospective study was designed to validate the clinical efficacy of the proposed Carebot AI MMG (also referred to as "DLAD"). Using a non-certified medical device, a test set of retrospectively collected mammography studies in standard projections (CC and MLO). The performance of the DLAD was evaluated against the ground truth for individual indications (breast density evaluation, breast lesion detection) using Accuracy.

    Measured: 2024

Secondary outcomes (2)
  1. Comparison of Accuracy of Clinician and DLAD Image Evaluation (Carebot AI MMG v2.2) in Breast Density Assessment

    Carebot AI MMG v2.2 classified mammography studies according to the ACR BI-RADS 5th edition, i.e. breast tissue density assessment into A/B/C/D classes. The performance of the Carebot AI MMG device was assessed relative to the ground truth and then compared with the performance of five independent radiologists with varying levels of experience (RAD 1-RAD 5). A rigorous statistical analysis was used in the BI-RADS breast density classification to evaluate the performance of each method - the proposed Carebot AI MMG v2.2 medical device and the compared radiologists in the multi-reader study. The analysis focused on key metrics including Accuracy, F1 Score (Macro-Averaged), Precision (Macro-Averaged), Recall (Macro-Averaged) and Cohen's Kappa (κ) to assess the strength of agreement. Given that all scans were evaluated by all radiologists in the comparison, a bootstrapping method that involves resampling the test data 1000 times.

    Measured: 2024

  2. Comparison of Accuracy of Clinician and DLAD Image Evaluation (Carebot AI MMG v2.2) in Breast Lesion Detection

    The medical device (DLAD, Carebot AI MMG v2.2) analyzed mammography studies in standard projections (CC and MLO) and classified the presence of lesions ("present" x "absent") at the mammography study level. DLAD performance was assessed relative to the ground truth and then compared to the performance of five independent radiologists with varying levels of experience (RAD 1-RAD 5). The investigators quantified the performance of diagnostic tests based on Sensitivity, Specificity and Balanced Accuracy. The investigators further assessed the statistical significance of differences between DLAD and individual radiologists using appropriate statistical tests. To determine the reliability of the metrics examined, the investigators calculated 95% confidence intervals using Wilson scores. To evaluate the statistical significance of differences in Sensitivity and Specificity between DLAD and individual radiologists, the investigators applied McNemar's test with a continuity correction.

    Measured: 2024

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 May 2024
  2. Study start14 Jan 2022
  3. Primary completion24 Apr 2024
  4. Study completion24 Apr 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Retrospective
Enrolment
122 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06428799
Sponsor's protocol ID
CB-MMG-01-MC
Acronym
EMBLEDDA-MMG
Status last verified
Mar 2026
First submitted
7 May 2024
Last updated
18 Mar 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

An observational study of Breast Cancer and Breast Tumor Benign, run by Carebot s.r.o. at 3 sites in Czechia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Czechia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Performance Test (time frame: 2024). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Mar 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in