AzTrials
AzTrials

Airway ManagementNCT06261619

Superiority Trial Between Sotair® Device Attached to Manual Resuscitator Versus Ventilation Alone

A study testing Adult Sotair Device in people with Airway Management and Respiration, Artificial, run by Rhode Island Hospital at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Effective respiratory ventilation is achieved by moving the right amount of air to and out of the lungs while keeping the pressures at a safe level. A disposable safety device, Adult Sotair®, was created to improve manual ventilation delivery. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Airway Management, Respiration, Artificial
What is being tested?
Adult Sotair Device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteUnited States
Study dates
9 May 2024to 18 Mar 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult patients who are scheduled for non-emergency surgery with general anesthesia (w/artificial airway) at Rhode Island Hospital.
  • American Society Of Anesthesiologists Physical Status 1 and 2

Who cannot join

  • American Society of Anesthesiologists Physical Status >3 (e.g. respiratory disease)
  • Oropharyngeal or facial pathology

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Rhode Island Hospital

    Providence, Rhode Island, 02903

Other trials in United States

About this study

Official title: A Comparative Trial Between Sotair® Device Attached to Manual Resuscitator Versus Manual Ventilation Alone in Patients Undergoing Non-emergent Surgery With General Anesthesia: A Prospective Randomized Cross-over Clinical Trial

Effective respiratory ventilation is achieved by moving the right amount of air to and out of the lungs while keeping the pressures at a safe level. A disposable safety device, Adult Sotair®, was created to improve manual ventilation delivery. In this superiority study, the investigators will perform two-group cross over randomized design to test the superiority of the Adult Sotair® device compared to manual ventilation alone.

Read the detailed description

Poor manual ventilation technique is a well-documented problem which occurs irrespective of a provider's qualifications or experience. A disposable safety device, Adult Sotair®, was created to improve manual ventilation delivery among providers. The device is attached to a manual resuscitator and employs a flow limiting valve mechanism to minimize excessive pressure in the airway system without venting air by capping peak flow rates at 55 L/min. For an average adult with normal lung compliance and resistance, this corresponds to a maximum airway pressure of approximately 20 cmH2O which minimizes air entry into the stomach. In this superiority study (margin 7.5 cm H20), the investigators will use a two-group cross over randomized design to test the superiority of the Adult Sotair® device compared to manual ventilation alone with respect to airway pressure.

Being tested
Adult Sotair Device
Keywords
Mechanical Ventilation, General Anesthesia, Bag Mask Ventilation, Adult Sotair Device
Medical subject headings
Respiratory Aspiration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Adult Sotair DeviceDevice

    Also called Sotair, SafeBVM

    Adult Sotair® device employs a flow limiting valve mechanism.

Study groups in NCT06261619
Study groupRoleWhat they receive
Bag mask ventilation with Adult Sotair deviceActive comparatorThe anesthesia provider will manually bag ventilate with the Adult Sotair® device for 3 minutes with an average respiratory rate of 12 breaths per minute with a deep breath every 30 seconds.
Receives: Device: Adult Sotair Device
Bag mask ventilationNo interventionThe anesthesia provider will manually bag ventilate for 3 minutes with an average respiratory rate of 12 breaths per minute with a deep breath every 30 seconds.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Peak airway pressure

    Mean of the maximum peak airway pressures expressed in cm H2O

    Measured: Recorded every thirty seconds for a total duration of 3 minutes for each arm of the study

Secondary outcomes (2)
  1. Tidal volume

    The amount of air that moves to or out of the lungs with each respiratory cycle. Measured in mL. Mean of the maximum tidal volumes every 30 seconds.

    Measured: Recorded every thirty seconds for a total duration of 3 minutes for each arm of the study

  2. Airflow

    Represents the volume of air moved per unit of time during inspiration and expiration. Measured (L/min)

    Measured: Recorded every thirty seconds for a total duration of 3 minutes for each arm of the study

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Feb 2024
  2. Study start9 May 2024
  3. Primary completion18 Mar 2025
  4. Study completion18 Mar 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Crossover
Model description
Study Design: A superiority trial; a single two-group cross over randomized trial.
Masking
Single blind
Who is masked
Participant
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06261619
Sponsor's protocol ID
2079951
Status last verified
Jul 2026
First submitted
7 Feb 2024
Last updated
21 Jul 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Yes: The IPD that underlie the results in a publication will be shared with other researchers.

Publications

  • Fogarty M, Kuck K, Orr J, Sakata D. A comparison of controlled ventilation with a noninvasive ventilator versus traditional mask ventilation. J Clin Monit Comput. 2020 Aug;34(4):771-777. doi: 10.1007/s10877-019-00365-1. Epub 2019 Jul 23.

    PubMed 31338661
  • von Goedecke A, Bowden K, Wenzel V, Keller C, Gabrielli A. Effects of decreasing inspiratory times during simulated bag-valve-mask ventilation. Resuscitation. 2005 Mar;64(3):321-5. doi: 10.1016/j.resuscitation.2004.09.003.

    PubMed 15733761
  • Culbreth RE, Gardenhire DS. Manual bag valve mask ventilation performance among respiratory therapists. Heart Lung. 2021 May-Jun;50(3):471-475. doi: 10.1016/j.hrtlng.2020.10.012. Epub 2020 Nov 1.

    PubMed 33138977

Questions about this trial

What is this clinical trial studying?

A study testing Adult Sotair Device in people with Airway Management and Respiration, Artificial, run by Rhode Island Hospital at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 21 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Peak airway pressure (time frame: Recorded every thirty seconds for a total duration of 3 minutes for each arm of the study). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06261619, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Jul 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in