Educational Problems3D-printedNCT06091644
The Performance of AirAngel® Videolaryngoscope
A study testing AirAngel® 3D printed videolaryngoscope in people with Educational Problems and Financial Hardship, run by Acibadem University at 1 site in Turkey (Türkiye).
Trial summary
Video laryngoscopy (VL) have certain advantages over other techniques, such as better glottic imaging, higher intubation success in individuals with difficult airways, less force required for intubation, less cervical spine movement, and better image capturing overall. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Educational Problems, Financial Hardship
- What is being tested?
- AirAngel® 3D printed videolaryngoscope
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 126 participants
- Where
- 1 siteTurkey (Türkiye)
- Study dates
- 1 Nov 2020to 28 Feb 2022
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Being senior medical students Not having received endotracheal intubation training
Who cannot join
- Refusal to participate in the study
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Comparison of AirAngel® vs Storz® Videolaryngoscope and Macintosh® Laryngoscope for Endotracheal Intubation Training: Prospective Randomized Crossover Study
Video laryngoscopy (VL) have certain advantages over other techniques, such as better glottic imaging, higher intubation success in individuals with difficult airways, less force required for intubation, less cervical spine movement, and better image capturing overall. Some experts have recently suggested that the VL should be accepted and used as the standard technique for imaging in all emergency intubations, not just difficult intubations. However, VL is often not accessible in low-income countries because of its high costs. Additionally, hospitals may not be able to reach the devices even if they can cover the cost in cases where the demand is excessive.
Three dimensional (3D) printing is the technology of producing objects in 3D from an existing or designed digital file. This rapidly developing technology is already used in many areas of daily life and has also been widely used in medical applications. 3D printers produce many expensive medical materials and devices at lower costs, enable personalized modeling (implants and prostheses), tissue cultures, and surgical planning, and can also be used as educational material. One of these applications is 3D-printed VL (3D-PVL), which has become prominent in pandemic conditions. A 3D-PVL can be obtained for only 6-30 United States dollars (USD) compared to a VL that costs thousands of US dollars.
Moreover, a study comparing 3D-PVL with standard VL in difficult airway management for experienced practitioners demonstrated comparable success rates in both devices. Furthermore, the VL created by modifying a Macintosh® laryngoscope (MCL) with an endoscope camera was reported superior to the standard MCL and comparable to the standard VL in the hands of experienced users. However, the literature presented no study that evaluated the efficiency of 3D-PVLs in inexperienced practitioners. Herein, our study aimed to investigate the effectiveness of 3D-PVLs in acquiring endotracheal intubation (ETI) skills in senior medical school students who are inexperienced users and compare 3D-PVL with standard MCL and VL.
Read the detailed description
Materials The globally accessible AirAngel® 5.5-mm standard adult laryngoscope model was chosen as the 3D-PVL blade model. AirAngel® is a 3D-PVL model produced with 3D printing technology, the digital file of which has been opened to public access by its designers, which has a hyper-angulated blade and allows transferring the images to devices such as a phone, computer, or tablet with an integrated endoscope camera. The AirAngel® 3D 5.5-mm standard adult laryngoscope model was printed with 3D printer at Acibadem Mehmet Ali Aydinlar University Incubation Center in 80% density and as five layers from polylactic acid (PLA) material. The indentation at the end of the printed laryngoscope was suitable for integrating a 5.5-mm diameter camera (endoscope). The PLA material used in printing costs approximately 6 USD.
We mounted a 5.5-mm diameter, light-emitting diode (LED)-illuminated, International Protection Code (IP)67-certified, and water-resistant endoscope camera with a resolution of 640 × 480 pixels equipped with a 1/9 inch complementary metal oxide semiconductor sensor and 1-m long universal serial bus (USB) connection to the printed laryngoscope for approximately 9 USD. The created 3D-PVL was connected to a smart phone compatible with USB On-The-Go, which is a feature that allows the phone to be used as a host allowing the use of other USB devices, with a 6.67-inch in-plane switching liquid crystal display with a resolution of 1080 × 2400 full high definition+ pixels. A smart phone-supported 3D-PVL was obtained in this way.
A standard MCL and Storz® VL (SVL) monitor was selected as the DL and VL devices to be compared with 3D-PVL, respectively. A size 3 Macintosh blade, which is the most commonly used in adults and compatible with 3D-PVL dimensions and design, was preferred for both MCL and SVL.
The tongue of the manikin was fully inflated with 10 mL of air when the manikin was being used as a difficult airway manikin (DAM), and the cervical spine screw was fully tightened to reduce head extension. No modifications were made when the manikin was used as a normal airway manikin (NAM). An endotracheal tube (ETT) with a standard 7.5-mm inner diameter was chosen. The stylet was placed in the ETT before the intervention. A new ETT and stylet were used in each intervention. Additionally, the ETTs were lubricated before each intervention.
Participants The study participant consisted of senior students enrolled in Acibadem Mehmet Ali Aydinlar University Faculty of Medicine. The study was conducted at the Center of Advanced Simulation and Education (CASE) laboratory. The senior medical school students (SMSS) were invited via e-mail by the medical education coordination office of the university from November 2020 to January 2022. SMSS were invited four times in total, twice in each academic year. Informed consent and study plan were shared within the invitation e-mail. The e-mail stated that this study would not be graded, it would not have any effect on school success, participation is not compulsory, and they can participate in the study by making an appointment with CASE at any time during the academic year.
The sample size was calculated using the G*Power Software® version 3.1.9.2 as follows based on the statistical comparison conducted according to the referenced publication. Type-1 error and power of the test were chosen as 5% and 95%, respectively. Consequently, the targeted sample size was calculated as 126 considering randomization. The applications received after a sufficient number of students applied to the study were rejected, and no more students were recruited.
SMSS routinely participate in the standardized airway training module during sixth-grade medical school education. ETI training is given with both standard MCL and VL in this module. Thus, users who received standardized training were the SMSS included in the study. Additionally, participants were asked about any experience in intubating a patient and none had any experience. A 30-min training video was prepared that indicated the differences between DL and VL, introduced DAMs and NAMs, and demonstrated ETI practices. All participants were required to watch this training video before the intervention.
Randomization Each ETI attempt could enhance the participant's experience in the next attempt. Hence, the order of use of ETI devices was randomized to avoid experience-based bias. Six subgroups were needed to determine the order in which the SMSS would use the devices based on a permutation of three because three ETI devices were planned to be used in total. Accordingly, participants were randomized into six groups using the Random Team Generator. Each group included 21 participants.
Study Protocol Six experiment stations were set up. Each table was ensured to have one airway manikin. NAMs were used in the first three stations, and DAMs were used in the subsequent three. The interventions were to be conducted by the participants using NAMs first, followed by DAMs in the predetermined randomization order. Participants were assisted by an experienced assistant researcher in ETI during their attempts to extend the ETT, who also check the intubation accuracy with a bag valve mask (BVM) at the end of the intervention.
Each participant was given 3 min before each intervention to be prepared for the device and manikin. It was aimed that the participants would not feel pressed for time and would not attempt to intubate quickly. To this end, 1 min was given to complete the intubation attempt. The intervention was started as the participant said, "I am ready," and the assistant researcher vented the ETT with the BVM as the participant said, "I am done," after he/she was sure that he/she had placed the ETT. The intubation time was assessed as the time elapsed between placing the laryngoscope in the mouth and the ventilation of the lungs or stomach. The intubation attempt was terminated although it was not completed yet and considered unsuccessful when the intubation time was over 1 min. Accurate ETT placement was evaluated by visual confirmation of the swelling of the lungs on the manikin. The intubation attempt was considered unsuccessful if the manikin's stomach was filled with air. Conversely, the intubation attempt was considered successful if one or both lungs were filled with air.
An unsuccessful intubation attempt is considered a failure of three or more intubation attempts by an experienced user, or the failure of the patient to maintain an airway when a permanent airway is required immediately. Conservative airway management maneuvers should be limited to 2-3 min because irreversible cerebral anoxia occurs within minutes. The maximum recommended duration of an intubation attempt is 30 s although with no precise definition of an unsuccessful intubation attempt in the literature. Intubation should continue after the patient is ventilated with BVM if the intubation period exceeds 30 s. Hence, intubation attempts that lasted longer than 30 s were considered unsuccessful, although the participants were given 1 min to complete the intubation. Thus, only the intubation attempts that lasted ≤30 s, in which the ETT was accurately placed in the trachea, and the lungs were ventilated were considered successful. The rate of successful intubation attempts was calculated based on the intubation attempts deemed successful according to the said criteria.
The participants were asked to evaluate the ease of use of the device with a 5-point (from very easy to very difficult) Likert-type scale and to what extent they could view the vocal cords during the intervention according to the Cormack-Lehane classification, which was provided to the SMSS with visual material in the form a Likert-type scale, after each intubation attempt. Thus, intubation times, ease of use scores, Cormack-Lehane grades, rates of accurate placement of ETT, and rates of successful intubation attempts were measured at the end of each intubation attempt with DAM or NAM using any of the three laryngoscopy devices.
- Conditions
- Educational Problems, Financial Hardship
- Being tested
- AirAngel® 3D printed videolaryngoscope
- Keywords
- Videolaryngoscope, 3-D printing, 3-Dimensional Printing
- Medical subject headings
- Financial Stress
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
AirAngel® 3D printed videolaryngoscopeDevice
Also called Storz® videolaryngoscope and, Macintosh® laryngoscope
This is a mannequin study that aims to compare a videolaryngoscope produced with 3D printing with a Storz videolaryngoscope and a Macintosh direct laryngoscope in the hands of inexperienced users in terms of ease of use, glottic imaging and intubation success.
| Study group | Role | What they receive |
|---|---|---|
| Evaluation of device performances in normal and difficult airway management | Other | Each endotracheal intubation (ETI) attempt could enhance the participant's experience in the next attempt. Hence, the order of use of ETI devices was randomized to avoid experience-based bias. Six subgroups were needed to determine the order in which the SMSS would use the devices based on a permutation of three because three ETI devices were planned to be used in total. Accordingly, participants were randomized into six groups using the Random Team Generator.
Six experiment stations were set up. Normal airway manikins (NAMs) were used in the first three stations, and difficult airway manikins (DAMs) were used in the subsequent three. The interventions were to be conducted by the participants using NAMs first, followed by DAMs in the predetermined randomization order. Participants were assisted by an experienced assistant researcher in ETI during their attempts to extend the ETT, who also check the intubation accuracy with a bag valve mask (BVM) at the end of the intervention. Receives: Device: AirAngel® 3D printed videolaryngoscope |
What is being measured
The primary outcome is the main question the study is designed to answer.
Effectiveness of 3D printed videolaryngoscope
It is a mannequin study that aims to compare a videolaryngoscope produced with 3D printing with a Storz videolaryngoscope and a Macintosh direct laryngoscope in the hands of inexperienced users in terms of intubation success. Accurate ETT placement was evaluated by visual confirmation of the swelling of the lungs on the manikin. The intubation attempt was considered unsuccessful if the manikin's stomach was filled with air. Conversely, the intubation attempt was considered successful if one or both lungs were filled with air. An unsuccessful intubation attempt is considered a failure of three or more intubation attempts by an experienced user, or the failure of the patient to maintain an airway when a permanent airway is required immediately.
Measured: Two years
Secondary outcomes (1)
The effectiveness of using a 3D printed videolaryngoscope during endotracheal intubation training.
Access to VLs is restricted due to their high cost, and we investigated whether a 3D printed videolaryngoscope could be used instead of these devices in intubation training. The participants were asked to evaluate the ease of use of the device with a 5-point (from very easy to very difficult) Likert-type scale and to what extent they could view the vocal cords during the intervention according to the Cormack-Lehane classification, which was provided to the SMSS with visual material in the form a Likert-type scale, after each intubation attempt.
Measured: Two years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted19 Oct 2023
- Study start1 Nov 2020
- Primary completion31 Jan 2022
- Study completion28 Feb 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Educational ProblemsStudies of the same condition, open and under way.
- More trials run by Acibadem UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 126 participants (actual)
Sponsor and investigators
- Lead sponsor
- Acibadem University
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Kamil Kayayurt, Ass Prof, Principal investigator, Acibadem University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06091644
- Sponsor's protocol ID
- ATADEK, 2020-25/22
- Acronym
- 3D-printed
- Status last verified
- Oct 2023
- First submitted
- 10 Oct 2023
- Last updated
- 19 Oct 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Pieters BMA, Maas EHA, Knape JTA, van Zundert AAJ. Videolaryngoscopy vs. direct laryngoscopy use by experienced anaesthetists in patients with known difficult airways: a systematic review and meta-analysis. Anaesthesia. 2017 Dec;72(12):1532-1541. doi: 10.1111/anae.14057. Epub 2017 Sep 22.
PubMed 28940354Maruyama K, Yamada T, Kawakami R, Hara K. Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study. Br J Anaesth. 2008 Oct;101(4):563-7. doi: 10.1093/bja/aen207. Epub 2008 Jul 25.
PubMed 18660500Zaouter C, Calderon J, Hemmerling TM. Videolaryngoscopy as a new standard of care. Br J Anaesth. 2015 Feb;114(2):181-3. doi: 10.1093/bja/aeu266. Epub 2014 Aug 23. No abstract available.
PubMed 25150988Lambert CT, John SC, John AV. Development and performance testing of the low-cost, 3D-printed, smartphone-compatible 'Tansen Videolaryngoscope' vs. Pentax-AWS videolaryngoscope vs. direct Macintosh laryngoscope: A manikin study. Eur J Anaesthesiol. 2020 Nov;37(11):992-998. doi: 10.1097/EJA.0000000000001264.
PubMed 32675700Cook TM, Kelly FE. A national survey of videolaryngoscopy in the United Kingdom. Br J Anaesth. 2017 Apr 1;118(4):593-600. doi: 10.1093/bja/aex052.
PubMed 28403414Coles-Black J, Chao I, Chuen J. Three-dimensional printing in medicine. Med J Aust. 2017 Aug 7;207(3):102-103. doi: 10.5694/mja16.01073. No abstract available.
PubMed 28764624
Study at a glance
From the registry record, last updated by the sponsor on 19 Oct 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison of AirAngel® vs Storz® Videolaryngoscope and Macintosh® Laryngoscope for Endotracheal Intubation Training: Prospective Randomized Crossover Study
- ClinicalTrials.gov ID
- NCT06091644
- Acronym / sponsor ID
- 3D-printed / ATADEK, 2020-25/22
- Conditions
- Educational Problems, Financial Hardship
- Keywords
- Videolaryngoscope, 3-D printing, 3-Dimensional Printing
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 126 participants (actual)
- Lead sponsor
- Acibadem UniversityUniversity, hospital or other
- Study start
- 1 Nov 2020 (actual)
- Primary completion
- 31 Jan 2022 (actual)
- Study completion
- 28 Feb 2022 (actual)
- First posted
- 19 Oct 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Video laryngoscopy (VL) have certain advantages over other techniques, such as better glottic imaging, higher intubation success in individuals with difficult airways, less force required for intubation, less cervical spine movement, and better image capturing overall. Some experts have recently suggested that the VL should be accepted and used as the standard technique for imaging in all emergency intubations, not just difficult intubations. However, VL is often not accessible in low-income countries because of its high costs. Additionally, hospitals may not be able to reach the devices even if they can cover the cost in cases where the demand is excessive.
Three dimensional (3D) printing is the technology of producing objects in 3D from an existing or designed digital file. This rapidly developing technology is already used in many areas of daily life and has also been widely used in medical applications. 3D printers produce many expensive medical materials and devices at lower costs, enable personalized modeling (implants and prostheses), tissue cultures, and surgical planning, and can also be used as educational material. One of these applications is 3D-printed VL (3D-PVL), which has become prominent in pandemic conditions. A 3D-PVL can be obtained for only 6-30 United States dollars (USD) compared to a VL that costs thousands of US dollars.
Moreover, a study comparing 3D-PVL with standard VL in difficult airway management for experienced practitioners demonstrated comparable success rates in both devices. Furthermore, the VL created by modifying a Macintosh® laryngoscope (MCL) with an endoscope camera was reported superior to the standard MCL and comparable to the standard VL in the hands of experienced users. However, the literature presented no study that evaluated the efficiency of 3D-PVLs in inexperienced practitioners. Herein, our study aimed to investigate the effectiveness of 3D-PVLs in acquiring endotracheal intubation (ETI) skills in senior medical school students who are inexperienced users and compare 3D-PVL with standard MCL and VL.
Detailed description
Materials The globally accessible AirAngel® 5.5-mm standard adult laryngoscope model was chosen as the 3D-PVL blade model. AirAngel® is a 3D-PVL model produced with 3D printing technology, the digital file of which has been opened to public access by its designers, which has a hyper-angulated blade and allows transferring the images to devices such as a phone, computer, or tablet with an integrated endoscope camera. The AirAngel® 3D 5.5-mm standard adult laryngoscope model was printed with 3D printer at Acibadem Mehmet Ali Aydinlar University Incubation Center in 80% density and as five layers from polylactic acid (PLA) material. The indentation at the end of the printed laryngoscope was suitable for integrating a 5.5-mm diameter camera (endoscope). The PLA material used in printing costs approximately 6 USD.
We mounted a 5.5-mm diameter, light-emitting diode (LED)-illuminated, International Protection Code (IP)67-certified, and water-resistant endoscope camera with a resolution of 640 × 480 pixels equipped with a 1/9 inch complementary metal oxide semiconductor sensor and 1-m long universal serial bus (USB) connection to the printed laryngoscope for approximately 9 USD. The created 3D-PVL was connected to a smart phone compatible with USB On-The-Go, which is a feature that allows the phone to be used as a host allowing the use of other USB devices, with a 6.67-inch in-plane switching liquid crystal display with a resolution of 1080 × 2400 full high definition+ pixels. A smart phone-supported 3D-PVL was obtained in this way.
A standard MCL and Storz® VL (SVL) monitor was selected as the DL and VL devices to be compared with 3D-PVL, respectively. A size 3 Macintosh blade, which is the most commonly used in adults and compatible with 3D-PVL dimensions and design, was preferred for both MCL and SVL.
The tongue of the manikin was fully inflated with 10 mL of air when the manikin was being used as a difficult airway manikin (DAM), and the cervical spine screw was fully tightened to reduce head extension. No modifications were made when the manikin was used as a normal airway manikin (NAM). An endotracheal tube (ETT) with a standard 7.5-mm inner diameter was chosen. The stylet was placed in the ETT before the intervention. A new ETT and stylet were used in each intervention. Additionally, the ETTs were lubricated before each intervention.
Participants The study participant consisted of senior students enrolled in Acibadem Mehmet Ali Aydinlar University Faculty of Medicine. The study was conducted at the Center of Advanced Simulation and Education (CASE) laboratory. The senior medical school students (SMSS) were invited via e-mail by the medical education coordination office of the university from November 2020 to January 2022. SMSS were invited four times in total, twice in each academic year. Informed consent and study plan were shared within the invitation e-mail. The e-mail stated that this study would not be graded, it would not have any effect on school success, participation is not compulsory, and they can participate in the study by making an appointment with CASE at any time during the academic year.
The sample size was calculated using the G*Power Software® version 3.1.9.2 as follows based on the statistical comparison conducted according to the referenced publication. Type-1 error and power of the test were chosen as 5% and 95%, respectively. Consequently, the targeted sample size was calculated as 126 considering randomization. The applications received after a sufficient number of students applied to the study were rejected, and no more students were recruited.
SMSS routinely participate in the standardized airway training module during sixth-grade medical school education. ETI training is given with both standard MCL and VL in this module. Thus, users who received standardized training were the SMSS included in the study. Additionally, participants were asked about any experience in intubating a patient and none had any experience. A 30-min training video was prepared that indicated the differences between DL and VL, introduced DAMs and NAMs, and demonstrated ETI practices. All participants were required to watch this training video before the intervention.
Randomization Each ETI attempt could enhance the participant's experience in the next attempt. Hence, the order of use of ETI devices was randomized to avoid experience-based bias. Six subgroups were needed to determine the order in which the SMSS would use the devices based on a permutation of three because three ETI devices were planned to be used in total. Accordingly, participants were randomized into six groups using the Random Team Generator. Each group included 21 participants.
Study Protocol Six experiment stations were set up. Each table was ensured to have one airway manikin. NAMs were used in the first three stations, and DAMs were used in the subsequent three. The interventions were to be conducted by the participants using NAMs first, followed by DAMs in the predetermined randomization order. Participants were assisted by an experienced assistant researcher in ETI during their attempts to extend the ETT, who also check the intubation accuracy with a bag valve mask (BVM) at the end of the intervention.
Each participant was given 3 min before each intervention to be prepared for the device and manikin. It was aimed that the participants would not feel pressed for time and would not attempt to intubate quickly. To this end, 1 min was given to complete the intubation attempt. The intervention was started as the participant said, "I am ready," and the assistant researcher vented the ETT with the BVM as the participant said, "I am done," after he/she was sure that he/she had placed the ETT. The intubation time was assessed as the time elapsed between placing the laryngoscope in the mouth and the ventilation of the lungs or stomach. The intubation attempt was terminated although it was not completed yet and considered unsuccessful when the intubation time was over 1 min. Accurate ETT placement was evaluated by visual confirmation of the swelling of the lungs on the manikin. The intubation attempt was considered unsuccessful if the manikin's stomach was filled with air. Conversely, the intubation attempt was considered successful if one or both lungs were filled with air.
An unsuccessful intubation attempt is considered a failure of three or more intubation attempts by an experienced user, or the failure of the patient to maintain an airway when a permanent airway is required immediately. Conservative airway management maneuvers should be limited to 2-3 min because irreversible cerebral anoxia occurs within minutes. The maximum recommended duration of an intubation attempt is 30 s although with no precise definition of an unsuccessful intubation attempt in the literature. Intubation should continue after the patient is ventilated with BVM if the intubation period exceeds 30 s. Hence, intubation attempts that lasted longer than 30 s were considered unsuccessful, although the participants were given 1 min to complete the intubation. Thus, only the intubation attempts that lasted ≤30 s, in which the ETT was accurately placed in the trachea, and the lungs were ventilated were considered successful. The rate of successful intubation attempts was calculated based on the intubation attempts deemed successful according to the said criteria.
The participants were asked to evaluate the ease of use of the device with a 5-point (from very easy to very difficult) Likert-type scale and to what extent they could view the vocal cords during the intervention according to the Cormack-Lehane classification, which was provided to the SMSS with visual material in the form a Likert-type scale, after each intubation attempt. Thus, intubation times, ease of use scores, Cormack-Lehane grades, rates of accurate placement of ETT, and rates of successful intubation attempts were measured at the end of each intubation attempt with DAM or NAM using any of the three laryngoscopy devices.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Evaluation of device performances in normal and difficult airway management | Other | Device: AirAngel® 3D printed videolaryngoscopeEach endotracheal intubation (ETI) attempt could enhance the participant's experience in the next attempt. Hence, the order of use of ETI devices was randomized to avoid experience-based bias. Six subgroups were needed to determine the order in which the SMSS would use the devices based on a permutation of three because three ETI devices were planned to be used in total. Accordingly, participants were randomized into six groups using the Random Team Generator. Six experiment stations were set up. Normal airway manikins (NAMs) were used in the first three stations, and difficult airway manikins (DAMs) were used in the subsequent three. The interventions were to be conducted by the participants using NAMs first, followed by DAMs in the predetermined randomization order. Participants were assisted by an experienced assistant researcher in ETI during their attempts to extend the ETT, who also check the intubation accuracy with a bag valve mask (BVM) at the end of the intervention. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Being senior medical students Not having received endotracheal intubation training
Key exclusion criteria (1 listed)
- Refusal to participate in the study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| AirAngel® 3D printed videolaryngoscopeAlso: Storz® videolaryngoscope and, Macintosh® laryngoscopeThis is a mannequin study that aims to compare a videolaryngoscope produced with 3D printing with a Storz videolaryngoscope and a Macintosh direct laryngoscope in the hands of inexperienced users in terms of ease of use, glottic imaging and intubation success. | Device | Evaluation of device performances in normal and difficult airway management |
Primary outcome
Effectiveness of 3D printed videolaryngoscope
Time frame: Two years
It is a mannequin study that aims to compare a videolaryngoscope produced with 3D printing with a Storz videolaryngoscope and a Macintosh direct laryngoscope in the hands of inexperienced users in terms of intubation success. Accurate ETT placement was evaluated by visual confirmation of the swelling of the lungs on the manikin. The intubation attempt was considered unsuccessful if the manikin's stomach was filled with air. Conversely, the intubation attempt was considered successful if one or both lungs were filled with air. An unsuccessful intubation attempt is considered a failure of three or more intubation attempts by an experienced user, or the failure of the patient to maintain an airway when a permanent airway is required immediately.
1 secondary outcome
The effectiveness of using a 3D printed videolaryngoscope during endotracheal intubation training.
Time frame: Two years
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Oct 2023.
- Background: PubMed 28940354Pieters BMA, Maas EHA, Knape JTA, van Zundert AAJ. Videolaryngoscopy vs. direct laryngoscopy use by experienced anaesthetists in patients with known difficult airways: a systematic review and meta-analysis. Anaesthesia. 2017 Dec;72(12):1532-1541. doi: 10.1111/anae.14057. Epub 2017 Sep 22.
- Background: PubMed 18660500Maruyama K, Yamada T, Kawakami R, Hara K. Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study. Br J Anaesth. 2008 Oct;101(4):563-7. doi: 10.1093/bja/aen207. Epub 2008 Jul 25.
- Background: PubMed 25150988Zaouter C, Calderon J, Hemmerling TM. Videolaryngoscopy as a new standard of care. Br J Anaesth. 2015 Feb;114(2):181-3. doi: 10.1093/bja/aeu266. Epub 2014 Aug 23. No abstract available.
- Background: PubMed 32675700Lambert CT, John SC, John AV. Development and performance testing of the low-cost, 3D-printed, smartphone-compatible 'Tansen Videolaryngoscope' vs. Pentax-AWS videolaryngoscope vs. direct Macintosh laryngoscope: A manikin study. Eur J Anaesthesiol. 2020 Nov;37(11):992-998. doi: 10.1097/EJA.0000000000001264.
- Background: PubMed 28403414Cook TM, Kelly FE. A national survey of videolaryngoscopy in the United Kingdom. Br J Anaesth. 2017 Apr 1;118(4):593-600. doi: 10.1093/bja/aex052.
- Background: PubMed 28764624Coles-Black J, Chao I, Chuen J. Three-dimensional printing in medicine. Med J Aust. 2017 Aug 7;207(3):102-103. doi: 10.5694/mja16.01073. No abstract available.
- Individual participant dataSharing planned: No
Related trials for Educational Problems
Not yet recruiting
Standardized Educational Videos of Laparoscopic Gynecological Surgeries
Educational Problems, Surgery
Active, not recruiting
Impact of Surgical Coaching on Resident ObGyn Laparoscopic Skills
Educational Problems
Not yet recruiting
Evaluation of a Couple-based Psycho-socio-educational Intervention Using WeChat/WhatsApp on Dyadic Psychological and Sleep Outcomes
Sleep Problems, Psychological
Active, not recruiting
Fostering Healthy Futures for Teens: An RCT
Child Abuse, Child Neglect
Recruiting
Health Equity and Rural Education (HERE!) Clinical Trial
Behavioral Symptoms, Community Health Workers
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Kamil Kayayurt, Ass Prof principal investigator
Acibadem University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing AirAngel® 3D printed videolaryngoscope in people with Educational Problems and Financial Hardship, run by Acibadem University at 1 site in Turkey (Türkiye).
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Oct 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Effectiveness of 3D printed videolaryngoscope (time frame: Two years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06091644, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Oct 2023.