Atrial FibrillationOmny-IRENCT05971693

A Study For Treatment of Paroxysmal Atrial Fibrillation (PAF) With the OMNYPULSE Catheter and the TRUPULSE Generator

A study testing OMNYPULSE Bi-Directional Catheter with TRUPULSE Generator in people with Atrial Fibrillation, run by Biosense Webster, Inc. at 13 sites in 8 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record

Search all trials

Trial summary

The purpose of this study is to demonstrate safety and effectiveness of the ablation system (OMNYPULSE Bi-directional catheter and TRUPULSE generator) when used for isolation of the atrial pulmonary veins (PVs) in treatment of participants with paroxysmal atrial fibrillation (PAF). Read more about this study

Who is it for?
Ages 18 to 75 years
Conditions the study is for
Atrial Fibrillation
What is being tested?
OMNYPULSE Bi-Directional Catheter with TRUPULSE Generator
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
188 participants
Where
13 sitesin 8 countries
Study dates
12 Sep 2023to 5 Sep 2025
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Diagnosed with Symptomatic paroxysmal atrial fibrillation (PAF) defined as as atrial fibrillation (AF) that terminates spontaneously or with intervention within 7 days of onset. This PAF is considered to be symptomatic if symptoms related to AF are experienced by the participant
  • Selected for AF ablation procedure by pulmonary vein isolation (PVI)
  • Willing and capable of providing consent
  • Able and willing to comply with all pre-, post- and follow-up testing and requirements

Who cannot join

  • Previously known AF secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause (example, documented obstructive sleep apnea, acute alcohol toxicity, morbid obesity [body mass index greater than {>} 40 kilograms per meter square {kg/m^2}]), renal insufficiency (with an estimated creatinine clearance less than (<) 30 milliliters per minute per 1.73 meter square [mL/min/1.73 m^2])
  • Previous left atrium (LA) ablation or surgery
  • Participants known to require ablation outside the PV region (example, atrioventricular reentrant tachycardia, atrioventricular nodal re-entry tachycardia, atrial tachycardia, ventricular tachycardia and Wolff-Parkinson-White)
  • Previously diagnosed with persistent AF (> 7 days in duration)
  • Severe dilatation of the left atrium (LA) (left anterior descending artery [LAD] >50 millimeter [mm] antero-posterior diameter in case of transthoracic echocardiography [TTE])
  • Presence of LA thrombus
Show all 33Show fewer
  • Severely compromised left ventricular ejection fraction (left ventricular ejection fraction [LVEF] <40 percentage [%])
  • Uncontrolled heart failure or New York Heart Association (NYHA) Class III or IV
  • History of blood clotting, bleeding abnormalities or contraindication to anticoagulation (heparin, warfarin, or dabigatran)
  • History of a documented thromboembolic event (including transient ischemic attack [TIA]) within the past 6 months
  • Previous percutaneous coronary intervention (PCI) / myocardial infarction (MI) within the past 2 months
  • Previous coronary artery bypass grafting (CABG) in conjunction with valvular surgery, cardiac surgery (example, ventriculotomy, atriotomy) or valvular cardiac (surgical or percutaneous) procedure
  • Unstable angina pectoris within the past 6 months
  • Anticipated cardiac transplantation, cardiac surgery, or other major surgery within the next 12 months
  • Significant pulmonary disease (example, restrictive pulmonary disease, constrictive or chronic obstructive pulmonary disease) or any other disease or malfunction of the lungs or respiratory system that produces severe chronic symptoms
  • Known significant pulmonary vein (PV) anomaly that in the opinion of the investigator would preclude enrollment in this study
  • Prior diagnosis of pulmonary vein stenosis
  • Pre-existing hemi diaphragmatic paralysis
  • Acute illness, active systemic infection, or sepsis
  • Presence of intracardiac thrombus, myxoma, tumor, interatrial baffle or patch or other abnormality that precludes catheter introduction or manipulation
  • Severe mitral regurgitation
  • Presence of implanted pacemaker or implantable cardioverter-defibrillator (ICD) or other implanted metal cardiac device that may interfere with the pulsed electric field energy
  • Presence of a condition that precludes vascular access (such as Inferior Vena Cava [IVC] filter)
  • Significant congenital anomaly or a medical problem that in the opinion of the investigator would preclude enrollment in this study
  • Categorized as vulnerable population and requires special treatment with respect to safeguards of well-being
  • Current enrollment in an investigational study evaluating another device or drug
  • Women who are pregnant (as evidenced by pregnancy test if pre-menopausal), lactating, or who are of child-bearing age and plan on becoming pregnant during the course of the clinical investigation
  • Life expectancy less than 12 months
  • Presenting contra-indications for the devices used in the study, as indicated in the respective Instructions For Use (IFU)
  • Known contraindication for magnetic resonance imaging (MRI) such as use of contrast agents due to advanced renal disease, claustrophobia etcetra. (at principle investigator [PI] discretion)
  • Presence of iron-containing metal fragments in the body
  • Known unresolved pre-existing neurological deficit
  • Known uncontrolled significant gastroesophageal reflux disease (GERD)

Trial locations and contacts

13 sites in 8 countries.

13 sites in 8 countries

Belgium4 sites
  • AZORG campus Aalst Moorselbaan

    Aalst, 9300

  • AZ Sint-Jan

    Bruges, 8000

  • Ziekenhuis Oost-Limburg

    Genk, 3600

  • Jessa Ziekenhuis - Campus Virga Jesse

    Hasselt, 3500

Other trials in Belgium

Canada2 sites
  • Montreal Heart Institute

    Montreal, Quebec, H1T 1C8

  • McGill University Health Centre

    Montreal, Quebec, H3G 1A4

Other trials in Canada

Czechia2 sites
  • IKEM

    Prague, 140 21

  • Nemocnice na Homolce

    Prague, 150 30 District 5

Other trials in Czechia

Croatia1 site
  • KBC Split

    Split, 21000

Other trials in Croatia

Germany1 site
  • MVZ CCB Frankfurt und Main Taunus GbR

    Frankfurt a.M., 60431

Other trials in Germany

Italy1 site
  • Generale Regionale F. Miulli

    Acquaviva delle Fonti, 70021

Other trials in Italy

Lithuania1 site
  • Vilnius University Hospital Santariskiu Klinikos

    Vilnius, 08661

Other trials in Lithuania

Netherlands1 site
  • Maastricht UMC

    Maastricht, 6229 HX

Other trials in Netherlands

About this study

Official title: Safety and Effectiveness Evaluation of the OMNYPULSE Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF)

The purpose of this study is to demonstrate safety and effectiveness of the ablation system (OMNYPULSE Bi-directional catheter and TRUPULSE generator) when used for isolation of the atrial pulmonary veins (PVs) in treatment of participants with paroxysmal atrial fibrillation (PAF).

Being tested
OMNYPULSE Bi-Directional Catheter with TRUPULSE Generator
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • OMNYPULSE Bi-Directional Catheter with TRUPULSE GeneratorDevice

    Participants will undergo catheter ablation with the PF ablation system consisting of the TRUPULSE generator (delivers PF energy through the study catheter) and the OMNYPULSE bi-directional catheter (indicated for use in catheter-based cardiac electrophysiological mapping [stimulating and recording] and, when used with a Generator, for cardiac ablation).

Study groups in NCT05971693
Study groupRoleWhat they receive
OMNYPULSE Bi-Directional Catheter with TRUPULSE GeneratorExperimentalParticipants with symptomatic paroxysmal atrial fibrillation (PAF) will undergo the ablation procedure with OMNYPULSE bi-directional catheter used in combination with the TRUPULSE generator for pulmonary vein isolation (PVI).
Receives: Device: OMNYPULSE Bi-Directional Catheter with TRUPULSE Generator

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Percentage of Participants With Primary Adverse Events (PAEs)

    Percentage of participants with PAEs was reported. PAEs (within seven [7] days of the index ablation procedure) included the following adverse events atrio-esophageal fistula, pulmonary vein stenosis, device or procedure related death, (up to 90 days post-procedure), phrenic nerve paralysis (permanent), cardiac tamponade/perforation (up to 30 days post-procedure), stroke/cerebrovascular accident (CVA), major vascular access complication, major bleeding, thromboembolism, myocardial infarction, transient ischemic attack (TIA), pericarditis, heart block, pulmonary edema (respiratory insufficiency), and vagal nerve injury/gastroparesis.

    Measured: 90 days post catheter insertion on Day 0

  2. Percentage of Participants With Acute Effectiveness Success

    Percentage of participants with acute effectiveness success were reported. Procedural success was defined as electrical isolation of clinically relevant targeted pulmonary veins (PV; confirmed by entrance block) after adenosine/isoproterenol challenge at the end of the index ablation procedure.

    Measured: Immediately post-procedure on Day 0 (post catheter insertion)

Secondary outcomes (1)
  1. Percentage of Participants With Freedom From Combined Documented (Symptomatic and Asymptomatic) Atrial Arrhythmia Episodes and Acute Procedural Failure

    Percentage of participants with freedom from combined documented (symptomatic and asymptomatic) atrial arrhythmia episodes and acute procedural failure were reported. Effectiveness success was defined as freedom from documented (symptomatic and asymptomatic) atrial arrhythmia (atrial fibrillation, atrial tachycardia or atrial flutter [AFL] of unknown origin [all AFL except those Cavotricuspid Isthmus (CTI) dependent AFL as confirmed by 12-lead electrocardiogram or entrainment maneuvers in an EP study]) episodes based on electrocardiographic data (greater than or equal to [>=] 30 seconds on arrhythmia monitoring device) during the effectiveness evaluation period (Day 91 to Day 365) on or off antiarrhythmic therapy. Acute procedural failure: failure to achieve entrance block with the study device in any of the clinically relevant targeted pulmonary veins (PVs). Kaplan-Meier (KM) estimate was used.

    Measured: From Day 0 to Day 365 post catheter insertion on Day 0

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Aug 2023
  2. Study start12 Sep 2023
  3. Primary completion10 Dec 2024
  4. Study completion5 Sep 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
188 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05971693
Sponsor's protocol ID
BWI202201
Other IDs
BWI202201
Acronym
Omny-IRE
Status last verified
Sep 2026
First submitted
25 Jul 2023
Last updated
29 Sep 2026
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Yes: The data sharing policy of the Janssen Pharmaceutical Companies of Johnson and Johnson is available at www.janssen.com/clinical-trials/transparency. As noted on this site, requests for access to the study data can be submitted through Yale Open Data Access (YODA) project site at yoda.yale.edu

Publications

  • Duytschaever M, Grimaldi M, De Potter T, Verma A, Macle L, Kautzner J, Linz D, Anic A, Van Herendael H, Rackauskas G, Neuzil P, Chun J, Schmidt B, Knecht S, Almorad A, Berte B, Reddy VY, Vijgen J. PVI With CF-Sensing Large-Tip Focal PFA Catheter With 3D Mapping for Paroxysmal AF: Omny-IRE 3-Month Results. JACC Clin Electrophysiol. 2025 Aug;11(8):1769-1782. doi: 10.1016/j.jacep.2025.04.008. Epub 2025 Apr 25.

    PubMed 40340298

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in