Fluid OverloadNCT05906355
Primary Clinical Evaluation of Wearable Filtrating Artificial Kidney Device for On-site Medical Rescue
A study testing the wearable filtrating artificial Kidney Device and traditional hemodialysis machine in people with Fluid Overload, run by Chinese PLA General Hospital at 1 site in China.
Trial summary
Fluid overload is a common feature of diseases such as heart failure and kidney injury, which can lead to pulmonary edema or even death if not treated in time. In order to rapidly relieve fluid overload in patients, a wearable filtrating artificial kidney device was developed. Read more about this study
- Who is it for?
- Ages 18 to 70 yearsHealthy volunteers can take part
- Conditions the study is for
- Fluid Overload
- What is being tested?
- the wearable filtrating artificial Kidney Device and traditional hemodialysis machine
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 12 participants
- Where
- 1 siteChina
- Study dates
- 25 Jun 2023to 31 Dec 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 70 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- 1.18 years ≤ age ≤ 70 years, regardless of gender. 2.Patients with fluid overload requiring ultrafiltration therapy. 3.The patient voluntarily participates and has obtained written informed consent signed by the patient or authorized delegate.
Who cannot join
- Mechanical failure of the ultrafiltration access.
- Presence of an active infection.
- Known HIV positivity.
- Poor compliance and inability to follow the regimen.
- Other serious medical conditions such as active, or previously treated residual malignancy or systemic infection, cirrhosis, anemia (Hb<70g/L), intractable hypertension, etc.
- History of alcohol and drug abuse (defined as the use of illegal drugs)
- Pregnancy or breastfeeding, women of childbearing age who do not agree to use effective contraception for the duration of the trial
- Any other condition that, in the opinion of the investigator, prevents the patient from enrolling in the trial.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: A Prospective, Cross-over, Controlled Primary Clinical Evaluation of the Precision, Security, and Operability of Wearable Filtrating Artificial Kidney Device for On-site Medical Rescue
Fluid overload is a common feature of diseases such as heart failure and kidney injury, which can lead to pulmonary edema or even death if not treated in time. In order to rapidly relieve fluid overload in patients, a wearable filtrating artificial kidney device was developed. The purpose of this study is to evaluation of the precision, security, and operability of wearable filtrating artificial kidney device for on-site medical rescue.
Read the detailed description
Background:Fluid overload into the tissue spaces of the body can lead to damage to multiple organs, mainly the heart, kidneys, lungs, and gastrointestinal system. Fluid overload can diminish myocardial function, induce maladaptive myocardial remodeling, and decrease coronary vascular reactivity, increasing the risk of myocardial ischemia. Increased interstitial fluid decreases renal capillary blood flow, leading to renal ischemia and acute renal failure. In the lungs, excess extravascular water impairs gas exchange, decreases pulmonary compliance, and significantly increases morbidity and mortality. Fluid overload can also lead to impaired liver function and prolonged wound healing, as well as being a risk factor for intra-abdominal hypertension, and edema of the intestinal wall can lead to decreased absorption, intestinal distention, and even intestinal obstruction.A wearable filtrating artificial kidney device has been developed to address volume overload in patients, and it has been evaluated for biosafety and animal testing, and third-party testing has been completed for device performance as required by Q/WLS 10101-2020. This study proposes to conduct human trials to evaluate its performance.
Methods: This is a prospective controlled study involving patients with fluid overload requiring ultrafiltration therapy. Inclusion criteria: 1. 18 years ≤ age ≤ 70 years, regardless of gender; 2. Patients with fluid overload requiring ultrafiltration therapy; 3. Patients voluntarily participated and obtained written informed consent signed by the patient or authorized delegate. Exclusion criteria: 1. Mechanical failure of the ultrafiltration access; 2. Presence of active infection; 3. Known HIV positivity; 4. Poor compliance with the regimen; 5. Other serious diseases, such as active or previously treated residual malignancy or systemic infection, cirrhosis, anemia (Hb < 70 g/L), and intractable hypertension. 6. History of alcohol and drug abuse (meaning use of illicit drugs); 7. Women of childbearing age who are pregnant or breastfeeding and do not agree to use effective contraception during the trial; 8. Any other condition that, in the opinion of the investigator, prevents the patient from participating in the trial.Primary Outcome Measure:(1)Precision of ultrafiltration:Ultrafiltration volume precision, ultrafiltration speed precision;(2).Security:Pressure alarm (times), bubble monitoring (times), sound and light alarm (times) and other machine indicators;patients' complaints of improvement, tolerance, comfort, etc.(3).Operability:Human-machine interaction, friendly interface, battery life, overall mass, main volume, portable features, etc.SPSS is applied for statistical analysis, and continuous variables are expressed as mean±standard deviation, and non-continuous variables are expressed as percentages. Comparisons between the two data are made by independent t-test or χ2 test, and P<0.05 is statistically significant.
- Conditions
- Fluid Overload
- Being tested
- the wearable filtrating artificial Kidney Device, traditional hemodialysis machine
- Keywords
- Wearable, Artificial Kidney Device, Fluid Overload
- Medical subject headings
- Edema
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
the wearable filtrating artificial Kidney DeviceDevice
the wearable filtrating artificial kidney device rapidly for rapid relief of fluid overload in patients
traditional hemodialysis machineDevice
the hemodialysis machine currently used in clinical practice to reduce fluid overload in patients
| Study group | Role | What they receive |
|---|---|---|
| Group A(wearable filtrating artificial Kidney+traditional hemodialysis) | Experimental | Group A was isolated ultrafiltration with wearable filtrating artificial Kidney Device first, and then with traditional hemodialysis machine. Receives: Device: the wearable filtrating artificial Kidney Device; Device: traditional hemodialysis machine |
| Group B(traditional hemodialysis+wearable filtrating artificial Kidney) | Experimental | Group B was isolated ultrafiltration with traditional dialysis machine first, and then with wearable filtrating artificial Kidney Device. Receives: Device: the wearable filtrating artificial Kidney Device; Device: traditional hemodialysis machine |
What is being measured
The primary outcome is the main question the study is designed to answer.
ultrafiltration volume of device
Compare the ultrafiltration volume of wearable filtrating artificial Kidney and traditional hemodialysis machine
Measured: 4 hours
ultrafiltration speed of device
Compare the ultrafiltration speed of wearable filtrating artificial Kidney and traditional hemodialysis machine
Measured: 4 hours
Secondary outcomes (7)
incidence of alarms of device
Compare the incidence of alarms of wearable filtrating artificial Kidney and traditional hemodialysis machine
Measured: 4 hours
arterial pressure displayed by the device
Compare the arterial pressure displayed by wearable filtrating artificial Kidney and traditional hemodialysis machine
Measured: 4 hours
venous pressure displayed by the device
Compare the venous pressure displayed by wearable filtrating artificial Kidney and traditional hemodialysis machine
Measured: 4 hours
patient satisfaction with the device
Survey question asking for qualitative description of satisfaction
Measured: 4 hours
nurse satisfaction with the device
Survey question asking for qualitative description of satisfaction
Measured: 4 hours
weight of device
The weight of device is measured in kg
Measured: before hemodialysis
volume of device
The volume of device is measured in Length x width x height
Measured: before hemodialysis
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Jun 2023
- Study start25 Jun 2023 (estimated)
- Primary completion31 Oct 2025 (estimated)
- Study completion31 Dec 2025 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Fluid OverloadStudies of the same condition, open and under way.
- More trials run by Chinese PLA General HospitalThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Enrolment
- 12 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Chinese PLA General Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Jianhui Zhou, Chinese PLA General Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05906355
- Sponsor's protocol ID
- S2022-120-01
- Status last verified
- Jun 2023
- First submitted
- 31 Jan 2023
- Last updated
- 15 Jun 2023
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 15 Jun 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective, Cross-over, Controlled Primary Clinical Evaluation of the Precision, Security, and Operability of Wearable Filtrating Artificial Kidney Device for On-site Medical Rescue
- ClinicalTrials.gov ID
- NCT05906355
- Acronym / sponsor ID
- S2022-120-01
- Conditions
- Fluid Overload
- Keywords
- Wearable, Artificial Kidney Device, Fluid Overload
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 12 participants (estimated)
- Lead sponsor
- Chinese PLA General HospitalUniversity, hospital or other
- Study start
- 25 Jun 2023 (estimated)
- Primary completion
- 31 Oct 2025 (estimated)
- Study completion
- 31 Dec 2025 (estimated)
- First posted
- 15 Jun 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Fluid overload is a common feature of diseases such as heart failure and kidney injury, which can lead to pulmonary edema or even death if not treated in time. In order to rapidly relieve fluid overload in patients, a wearable filtrating artificial kidney device was developed. The purpose of this study is to evaluation of the precision, security, and operability of wearable filtrating artificial kidney device for on-site medical rescue.
Detailed description
Background:Fluid overload into the tissue spaces of the body can lead to damage to multiple organs, mainly the heart, kidneys, lungs, and gastrointestinal system. Fluid overload can diminish myocardial function, induce maladaptive myocardial remodeling, and decrease coronary vascular reactivity, increasing the risk of myocardial ischemia. Increased interstitial fluid decreases renal capillary blood flow, leading to renal ischemia and acute renal failure. In the lungs, excess extravascular water impairs gas exchange, decreases pulmonary compliance, and significantly increases morbidity and mortality. Fluid overload can also lead to impaired liver function and prolonged wound healing, as well as being a risk factor for intra-abdominal hypertension, and edema of the intestinal wall can lead to decreased absorption, intestinal distention, and even intestinal obstruction.A wearable filtrating artificial kidney device has been developed to address volume overload in patients, and it has been evaluated for biosafety and animal testing, and third-party testing has been completed for device performance as required by Q/WLS 10101-2020. This study proposes to conduct human trials to evaluate its performance.
Methods: This is a prospective controlled study involving patients with fluid overload requiring ultrafiltration therapy. Inclusion criteria: 1. 18 years ≤ age ≤ 70 years, regardless of gender; 2. Patients with fluid overload requiring ultrafiltration therapy; 3. Patients voluntarily participated and obtained written informed consent signed by the patient or authorized delegate. Exclusion criteria: 1. Mechanical failure of the ultrafiltration access; 2. Presence of active infection; 3. Known HIV positivity; 4. Poor compliance with the regimen; 5. Other serious diseases, such as active or previously treated residual malignancy or systemic infection, cirrhosis, anemia (Hb < 70 g/L), and intractable hypertension. 6. History of alcohol and drug abuse (meaning use of illicit drugs); 7. Women of childbearing age who are pregnant or breastfeeding and do not agree to use effective contraception during the trial; 8. Any other condition that, in the opinion of the investigator, prevents the patient from participating in the trial.Primary Outcome Measure:(1)Precision of ultrafiltration:Ultrafiltration volume precision, ultrafiltration speed precision;(2).Security:Pressure alarm (times), bubble monitoring (times), sound and light alarm (times) and other machine indicators;patients' complaints of improvement, tolerance, comfort, etc.(3).Operability:Human-machine interaction, friendly interface, battery life, overall mass, main volume, portable features, etc.SPSS is applied for statistical analysis, and continuous variables are expressed as mean±standard deviation, and non-continuous variables are expressed as percentages. Comparisons between the two data are made by independent t-test or χ2 test, and P<0.05 is statistically significant.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Group A(wearable filtrating artificial Kidney+traditional hemodialysis) | Experimental | Device: the wearable filtrating artificial Kidney Device, Device: traditional hemodialysis machineGroup A was isolated ultrafiltration with wearable filtrating artificial Kidney Device first, and then with traditional hemodialysis machine. |
| Group B(traditional hemodialysis+wearable filtrating artificial Kidney) | Experimental | Device: the wearable filtrating artificial Kidney Device, Device: traditional hemodialysis machineGroup B was isolated ultrafiltration with traditional dialysis machine first, and then with wearable filtrating artificial Kidney Device. |
Who may qualify
- Ages
- 18 to 70 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- 1.18 years ≤ age ≤ 70 years, regardless of gender. 2.Patients with fluid overload requiring ultrafiltration therapy. 3.The patient voluntarily participates and has obtained written informed consent signed by the patient or authorized delegate.
Key exclusion criteria (8 listed)
- Mechanical failure of the ultrafiltration access.
- Presence of an active infection.
- Known HIV positivity.
- Poor compliance and inability to follow the regimen.
- Other serious medical conditions such as active, or previously treated residual malignancy or systemic infection, cirrhosis, anemia (Hb<70g/L), intractable hypertension, etc.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| the wearable filtrating artificial Kidney Devicethe wearable filtrating artificial kidney device rapidly for rapid relief of fluid overload in patients | Device | Group A(wearable filtrating artificial Kidney+traditional hemodialysis), Group B(traditional hemodialysis+wearable filtrating artificial Kidney) |
| traditional hemodialysis machinethe hemodialysis machine currently used in clinical practice to reduce fluid overload in patients | Device | Group A(wearable filtrating artificial Kidney+traditional hemodialysis), Group B(traditional hemodialysis+wearable filtrating artificial Kidney) |
Primary outcome
ultrafiltration volume of device
Time frame: 4 hours
Compare the ultrafiltration volume of wearable filtrating artificial Kidney and traditional hemodialysis machine
ultrafiltration speed of device
Time frame: 4 hours
Compare the ultrafiltration speed of wearable filtrating artificial Kidney and traditional hemodialysis machine
7 secondary outcomes
incidence of alarms of device
Time frame: 4 hours
arterial pressure displayed by the device
Time frame: 4 hours
venous pressure displayed by the device
Time frame: 4 hours
patient satisfaction with the device
Time frame: 4 hours
nurse satisfaction with the device
Time frame: 4 hours
weight of device
Time frame: before hemodialysis
volume of device
Time frame: before hemodialysis
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Jun 2023.
Related trials for Fluid Overload
Recruiting
Early Deresuscitation Strategy Driven by Tissue Perfusion in Renal Replacement Therapy in Patients With Acute Renal Failure
Acute Kidney Injury, Fluid Overload
Recruiting
Reducing Fluid Overload in Heart Failure Patients Using a Non-invasive, Renal Independent System
Chronic Heart Failure, CKD Stage 3
Not yet recruitingPhase 4
Capital Offload-Shock
Hypervolemia, Cardiogenic Shock
Recruiting
Dry Weight Reduction Intervention Via Extra Ultrafiltration
Fluid Accumulation, Blood Pressure Management
Not yet recruiting
Bioimpedance and Multiparametric Ultrasound-Guided Fluid Management After Kidney Transplantation
Kidney Transplantation, Delayed Graft Function
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing the wearable filtrating artificial Kidney Device and traditional hemodialysis machine in people with Fluid Overload, run by Chinese PLA General Hospital at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 15 Jun 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Yang Qiaoqiao, doctor (18754800176, connie_az@163.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
ultrafiltration volume of device (time frame: 4 hours). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jun 2023.