Diseases of Mitral and Aortic ValvesNCT05895487
Study on Efficacy, Safety and Durability of the UniLine Prosthesis in the Treatment of Aortic and Mitral Valve Disease
An observational study of Diseases of Mitral and Aortic Valves and Rheumatic Disorders of Mitral and Aortic Valves, run by Closed Joint-Stock Company NeoCor at 1 site in Russia.
Trial summary
Acquired heart diseases continue to remain one of the most common causes of cardiac mortality and morbidity. In the Russian Federation, open surgery treatment of acquired valvular heart diseases (AVHD) is performed in more than 40 regions by specialists from 92 healthcare organizations. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Diseases of Mitral and Aortic Valves, Rheumatic Disorders of Mitral and Aortic Valves, Other Congenital Malformations of Aortic and Mitral Valves
- How many people
- 2,000 participants
- Where
- 1 siteRussia
- Study dates
- 1 Nov 2022to 1 May 2026
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients aged 18 years and older who underwent isolated mitral or aortic valve replacement.
Who may be able to join
- Patients of both sexes aged 18 years and older who underwent isolated mitral or aortic valve replacement using the "UniLine" bioprosthesis
- No prior heart valve replacement
Who cannot join
- The presence of a mechanical or biological prosthesis in another position
- Prior valve repair
- Aortic aneurysm repair (ascending aorta)
- Resection of a left ventricular aneurysm
- Patients with active cancer and patients with history of cancer
Trial locations and contacts
1 site in 1 country.
Russia1 site, 1 recruiting
- Recruiting
Federal State Budgetary Scientific Institution "Research Institute for Complex Issues of Cardiovascilar Diseases"
Kemerovo, 650002
Olga Kuzmina, MD, PhD, +7 (3842) 644240, kuzmok@kemcardio.ru
About this study
Official title: Multicentered Observational Cohort Study on the Efficacy, Safety and Durability of the "UniLine" Epoxy-treated Prosthesis Made With Xenopericardium in the Treatment of Isolated Aortic and Mitral Valve Disease (UniLine RetroFit)
Acquired heart diseases continue to remain one of the most common causes of cardiac mortality and morbidity. In the Russian Federation, open surgery treatment of acquired valvular heart diseases (AVHD) is performed in more than 40 regions by specialists from 92 healthcare organizations.
Treating aortic or mitral valve disease using the "UniLine" biological prosthesis is expected to improve survival rates. Supposedly, in vivo the "UniLine" biological prosthesis will show optimal hemodynamic characteristics and high resistance to structural valve degeneration and infectious damage, thus lowering the risk of dysfunction. Moreover, the risk of repeated intervention due to dysfunction of the "UniLine" bioprosthesis should not exceed the risk of the primary implantation. Supposedly, in the case of dysfunction of "UniLine" bioprosthesis it would be possible to perform repeated replacement using valve-in-valve technique.
Read more
The aim of the study is to assess the effectiveness, safety, durability of the "UniLine" epoxy-treated prosthesis and the long-term outcome of the treatment of isolated mitral and aortic valve diseases using this prosthesis.
In accordance with the objectives and hypothesis, the following data will be analyzed: actuarial and linear survival rates (general and cardiac), non-lethal prosthesis-associated complications, prosthetic dysfunction and repeated interventions.
Moreover, in vivo hemodynamic parameters of the prosthesis will be assessed: the area of the effective opening surface, peak and mean gradient of pressure and blood flow velocity.
The study will be conducted at the Research Institute of Complex Issues of Cardiovascular Diseases. Study protocol received sponsorship approval and approval by Local Ethics Committee of the Research Institute and Research Coordinating Committee. The study will enroll patients who underwent isolated mitral or aortic valve replacement; transthoracic echocardiography will be conducted in all patients available for in-person visit.
Read the detailed description
Acquired heart diseases continue to remain one of the most common causes of cardiac mortality and morbidity. In Russia, heart valve diseases account for 7 to 25% of all cardiovascular diseases, moreover, they rank third as the cause of heart failure. Prosthetic heart valves commonly used as an effective treatment of acquired valvular heart diseases (AVHD). In the Russian Federation, open surgery treatment of AVHD is performed in more than 40 regions by specialists from 92 healthcare organizations. Surgeries on heart valves, being high-tech care, most effectively prolong the life of patients. Timely treatment of the disease allows 75-95% of patients to return to an active lifestyle and work. The purpose of surgical interventions is to increase life expectancy and to improve the quality of life, which can be achieved via adequate changes in intracardiac hemodynamics and reverse remodeling in the postoperative period.
Bioprosthetic heart valves, unlike most mechanical valves, are characterized by high thromboresistance, optimal (similar to native) hemodynamics parameters and quietness; they improve the quality of life of patients and do not require anticoagulant therapy in the long-term postoperative period. Moreover, bioprosthetic valve dysfunction develops slowly (within a few months or years), meaning that there is time for further examination and preoperative preparation, and a patient's life can be saved.
The "UniLine" bioprosthesis is designed for mitral or aortic valve replacement. This medical device has been used in clinical practice since 2008. Manufacturing of the "UniLine" bioprosthesis involves novel and innovative technologies, including high-precision thickness measurement and laser cutting for the leaflets, which prevents the unfolding of collagen structure along the edge of the cut, and ensures maximum uniformity of the material used, preventing the development of fatigue-induced changes. Unique modeling of leaflets provides complete coaptation. Anticalcification treatment with aminophosphonates contributes to a significant decrease in calcium-binding capacity, which helps to reduce the risk of dysfunction. The absence of synthetic components in the bioprosthesis should reduce the likelihood of endocarditis. Xenopericardium is preserved by using the epoxide compound (diglycidyl ether of ethylene glycol) under low pressure. Each "UniLine" bioprosthesis is subject to mandatory preclinical hydrodynamic assessment in accordance with the National Standards of the Russian Federation (GOST 26997-2003 and GOST 52999-2008). The "UniLine" atrioventricular biological prosthesis is manufactured in standard sizes 26, 28, 30 and 32, the "UniLine" aortic biological prosthesis is manufactured in standard sizes 21, 23, 25.
Treating aortic or mitral valve disease using the "UniLine" biological prosthesis is expected to improve survival rates. Supposedly, in vivo the "UniLine" biological prosthesis will show optimal hemodynamic characteristics and high resistance to structural valve degeneration and infectious damage, thus lowering the risk of dysfunction. Moreover, the risk of repeated intervention due to dysfunction of the "UniLine" bioprosthesis should not exceed the risk of the primary implantation. Supposedly, in the case of dysfunction of "UniLine" bioprosthesis it would be possible to perform repeated replacement using valve-in-valve technique.
The aim of the study is to assess the effectiveness, safety, durability of the "UniLine" epoxy-treated prosthesis and the long-term outcome of the treatment of isolated mitral and aortic valve diseases using this prosthesis.
In accordance with the objectives and hypothesis, the following data will be analyzed: actuarial and linear survival rates (general and cardiac), non-lethal prosthesis-associated complications, prosthetic dysfunction and repeated interventions.
Moreover, in vivo hemodynamic parameters of the prosthesis will be assessed: the area of the effective opening surface, peak and mean gradient of pressure and blood flow velocity.
The study will be conducted at the Research Institute of Complex Issues of Cardiovascular Diseases. Study protocol received sponsorship approval and approval by Ethics Committee of the Research Institute and Research Coordinating Committee. The study will enroll 2000 patients who underwent isolated mitral or aortic valve replacement; transthoracic echocardiography will be conducted in all patients available for in-person visit.
- Conditions
- Diseases of Mitral and Aortic Valves, Rheumatic Disorders of Mitral and Aortic Valves, Other Congenital Malformations of Aortic and Mitral Valves, Valvular Heart Disease (Aortic and Mitral Valves), Mitral Valve Insufficiency and Aortic Valve Insufficiency
- Keywords
- acquired heart diseases, mitral valve, aortic valve, prosthetic heart valves, bioprosthetic valves "UniLine", bioprosthetic valve dysfunction
- Medical subject headings
- Heart Valve Diseases, Mitral Valve Insufficiency, Aortic Valve Insufficiency
What is being measured
The primary outcome is the main question the study is designed to answer.
Long-term safety and durability of the "UniLine" epoxy-treated prosthesis made with xenopericardium in the treatment of isolated mitral and aortic valve diseases
Long-term safety of the "UniLine" epoxy-treated prosthesis made with xenopericardium in the treatment of isolated mitral and aortic valve diseases will be evaluated by the frequency of complications associated with the valve.
Device safety is defined as the absence of severe adverse events associated with the device or procedure, assessed by the following clinical phenomena:
- Death
- Severe complications of the heart
- Life-threatening bleeding
- Any bioprosthesis-related dysfunction, migration, thrombosis or other complication requiring an open-heart surgery or repeated intervention.
- Myocardial infarction (or ACS) or progression of a chronic form of ischemia requiring percutaneous coronary intervention or coronary artery bypass grafting
- Access site complications
- Stroke
Measured: Up to 12 years from the moment of implantation
The long-term durability of the bioprosthesis will be evaluated by assessing the hemodynamic characteristics of the bioprosthetic valve (data obtained by echocardiography).
- Peak and mean gradient on the atrioventricular bioprosthesis (as provided by manufacturer manufacturer).
- The effective orifice area of the bioprosthesis (as provided by manufacturer manufacturer).
Measured: Up to 12 years from the moment of implantation
Secondary outcomes (5)
Frequency of adverse events
Frequency of adverse events
Measured: Up to 12 years from the moment of implantation
Frequency of severe adverse events
Frequency of severe adverse events
Measured: Up to 12 years from the moment of implantation
Frequency of adverse events associated with the device
Frequency of adverse events associated with the device
Measured: Up to 12 years from the moment of implantation
Frequency of adverse events associated with the procedure
Frequency of adverse events associated with the procedure
Measured: Up to 12 years from the moment of implantation
The absence of all-cause mortality
The absence of all-cause mortality
Measured: Up to 12 years from the moment of implantation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Jun 2023
- Study start1 Nov 2022
- Primary completion1 Oct 2025 (estimated)
- Study completion1 May 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Diseases of Mitral and Aortic ValvesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Retrospective
- Enrolment
- 2,000 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Closed Joint-Stock Company NeoCor
- Sponsor type
- University, hospital or other
- Collaborators
- CT Medical Limited Liability Company, Research Institute for Complex Problems of Cardiovascular Diseases, Russia
- Responsible party
- Sponsor
- Investigators
- Alexander Bogachev-Prokofiev, MD, PhD, Principal investigator, National Medical Research Center named after Academician E.N. MeshalkinAlexey Evtushenko, MD, PhD, Principal investigator, Research Institute for Complex Issues of Cardiovascular Diseases
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05895487
- Sponsor's protocol ID
- UL RF - 01
- Status last verified
- Sep 2024
- First submitted
- 19 May 2023
- Last updated
- 26 Sep 2024
- Results posted
- No
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 26 Sep 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Multicentered Observational Cohort Study on the Efficacy, Safety and Durability of the "UniLine" Epoxy-treated Prosthesis Made With Xenopericardium in the Treatment of Isolated Aortic and Mitral Valve Disease (UniLine RetroFit)
- ClinicalTrials.gov ID
- NCT05895487
- Acronym / sponsor ID
- UL RF - 01
- Conditions
- Diseases of Mitral and Aortic Valves, Rheumatic Disorders of Mitral and Aortic Valves, Other Congenital Malformations of Aortic and Mitral Valves, Valvular Heart Disease (Aortic and Mitral Valves), Mitral Valve Insufficiency and Aortic Valve Insufficiency
- Keywords
- acquired heart diseases, mitral valve, aortic valve, prosthetic heart valves, bioprosthetic valves "UniLine", bioprosthetic valve dysfunction
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 2,000 participants (estimated)
- Lead sponsor
- Closed Joint-Stock Company NeoCorUniversity, hospital or other
- Collaborators
- CT Medical Limited Liability Company, Research Institute for Complex Problems of Cardiovascular Diseases, Russia
- Study start
- 1 Nov 2022 (actual)
- Primary completion
- 1 Oct 2025 (estimated)
- Study completion
- 1 May 2026 (estimated)
- First posted
- 8 Jun 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Acquired heart diseases continue to remain one of the most common causes of cardiac mortality and morbidity. In the Russian Federation, open surgery treatment of acquired valvular heart diseases (AVHD) is performed in more than 40 regions by specialists from 92 healthcare organizations.
Treating aortic or mitral valve disease using the "UniLine" biological prosthesis is expected to improve survival rates. Supposedly, in vivo the "UniLine" biological prosthesis will show optimal hemodynamic characteristics and high resistance to structural valve degeneration and infectious damage, thus lowering the risk of dysfunction. Moreover, the risk of repeated intervention due to dysfunction of the "UniLine" bioprosthesis should not exceed the risk of the primary implantation. Supposedly, in the case of dysfunction of "UniLine" bioprosthesis it would be possible to perform repeated replacement using valve-in-valve technique.
The aim of the study is to assess the effectiveness, safety, durability of the "UniLine" epoxy-treated prosthesis and the long-term outcome of the treatment of isolated mitral and aortic valve diseases using this prosthesis.
In accordance with the objectives and hypothesis, the following data will be analyzed: actuarial and linear survival rates (general and cardiac), non-lethal prosthesis-associated complications, prosthetic dysfunction and repeated interventions.
Moreover, in vivo hemodynamic parameters of the prosthesis will be assessed: the area of the effective opening surface, peak and mean gradient of pressure and blood flow velocity.
The study will be conducted at the Research Institute of Complex Issues of Cardiovascular Diseases. Study protocol received sponsorship approval and approval by Local Ethics Committee of the Research Institute and Research Coordinating Committee. The study will enroll patients who underwent isolated mitral or aortic valve replacement; transthoracic echocardiography will be conducted in all patients available for in-person visit.
Detailed description
Acquired heart diseases continue to remain one of the most common causes of cardiac mortality and morbidity. In Russia, heart valve diseases account for 7 to 25% of all cardiovascular diseases, moreover, they rank third as the cause of heart failure. Prosthetic heart valves commonly used as an effective treatment of acquired valvular heart diseases (AVHD). In the Russian Federation, open surgery treatment of AVHD is performed in more than 40 regions by specialists from 92 healthcare organizations. Surgeries on heart valves, being high-tech care, most effectively prolong the life of patients. Timely treatment of the disease allows 75-95% of patients to return to an active lifestyle and work. The purpose of surgical interventions is to increase life expectancy and to improve the quality of life, which can be achieved via adequate changes in intracardiac hemodynamics and reverse remodeling in the postoperative period.
Bioprosthetic heart valves, unlike most mechanical valves, are characterized by high thromboresistance, optimal (similar to native) hemodynamics parameters and quietness; they improve the quality of life of patients and do not require anticoagulant therapy in the long-term postoperative period. Moreover, bioprosthetic valve dysfunction develops slowly (within a few months or years), meaning that there is time for further examination and preoperative preparation, and a patient's life can be saved.
The "UniLine" bioprosthesis is designed for mitral or aortic valve replacement. This medical device has been used in clinical practice since 2008. Manufacturing of the "UniLine" bioprosthesis involves novel and innovative technologies, including high-precision thickness measurement and laser cutting for the leaflets, which prevents the unfolding of collagen structure along the edge of the cut, and ensures maximum uniformity of the material used, preventing the development of fatigue-induced changes. Unique modeling of leaflets provides complete coaptation. Anticalcification treatment with aminophosphonates contributes to a significant decrease in calcium-binding capacity, which helps to reduce the risk of dysfunction. The absence of synthetic components in the bioprosthesis should reduce the likelihood of endocarditis. Xenopericardium is preserved by using the epoxide compound (diglycidyl ether of ethylene glycol) under low pressure. Each "UniLine" bioprosthesis is subject to mandatory preclinical hydrodynamic assessment in accordance with the National Standards of the Russian Federation (GOST 26997-2003 and GOST 52999-2008). The "UniLine" atrioventricular biological prosthesis is manufactured in standard sizes 26, 28, 30 and 32, the "UniLine" aortic biological prosthesis is manufactured in standard sizes 21, 23, 25.
Treating aortic or mitral valve disease using the "UniLine" biological prosthesis is expected to improve survival rates. Supposedly, in vivo the "UniLine" biological prosthesis will show optimal hemodynamic characteristics and high resistance to structural valve degeneration and infectious damage, thus lowering the risk of dysfunction. Moreover, the risk of repeated intervention due to dysfunction of the "UniLine" bioprosthesis should not exceed the risk of the primary implantation. Supposedly, in the case of dysfunction of "UniLine" bioprosthesis it would be possible to perform repeated replacement using valve-in-valve technique.
The aim of the study is to assess the effectiveness, safety, durability of the "UniLine" epoxy-treated prosthesis and the long-term outcome of the treatment of isolated mitral and aortic valve diseases using this prosthesis.
In accordance with the objectives and hypothesis, the following data will be analyzed: actuarial and linear survival rates (general and cardiac), non-lethal prosthesis-associated complications, prosthetic dysfunction and repeated interventions.
Moreover, in vivo hemodynamic parameters of the prosthesis will be assessed: the area of the effective opening surface, peak and mean gradient of pressure and blood flow velocity.
The study will be conducted at the Research Institute of Complex Issues of Cardiovascular Diseases. Study protocol received sponsorship approval and approval by Ethics Committee of the Research Institute and Research Coordinating Committee. The study will enroll 2000 patients who underwent isolated mitral or aortic valve replacement; transthoracic echocardiography will be conducted in all patients available for in-person visit.
Study design
- Observational model
- Cohort
- Time perspective
- Retrospective
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients aged 18 years and older who underwent isolated mitral or aortic valve replacement.
Key inclusion criteria (2 listed)
- Patients of both sexes aged 18 years and older who underwent isolated mitral or aortic valve replacement using the "UniLine" bioprosthesis
- No prior heart valve replacement
Key exclusion criteria (5 listed)
- The presence of a mechanical or biological prosthesis in another position
- Prior valve repair
- Aortic aneurysm repair (ascending aorta)
- Resection of a left ventricular aneurysm
- Patients with active cancer and patients with history of cancer
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Long-term safety and durability of the "UniLine" epoxy-treated prosthesis made with xenopericardium in the treatment of isolated mitral and aortic valve diseases
Time frame: Up to 12 years from the moment of implantation
Long-term safety of the "UniLine" epoxy-treated prosthesis made with xenopericardium in the treatment of isolated mitral and aortic valve diseases will be evaluated by the frequency of complications associated with the valve. Device safety is defined as the absence of severe adverse events associated with the device or procedure, assessed by the following clinical phenomena: 1. Death 2. Severe complications of the heart 3. Life-threatening bleeding 4. Any bioprosthesis-related dysfunction, migration, thrombosis or other complication requiring an open-heart surgery or repeated intervention. 5. Myocardial infarction (or ACS) or progression of a chronic form of ischemia requiring percutaneous coronary intervention or coronary artery bypass grafting 6. Access site complications 7. Stroke
The long-term durability of the bioprosthesis will be evaluated by assessing the hemodynamic characteristics of the bioprosthetic valve (data obtained by echocardiography).
Time frame: Up to 12 years from the moment of implantation
1. Peak and mean gradient on the atrioventricular bioprosthesis (as provided by manufacturer manufacturer). 2. The effective orifice area of the bioprosthesis (as provided by manufacturer manufacturer).
5 secondary outcomes
Frequency of adverse events
Time frame: Up to 12 years from the moment of implantation
Frequency of severe adverse events
Time frame: Up to 12 years from the moment of implantation
Frequency of adverse events associated with the device
Time frame: Up to 12 years from the moment of implantation
Frequency of adverse events associated with the procedure
Time frame: Up to 12 years from the moment of implantation
The absence of all-cause mortality
Time frame: Up to 12 years from the moment of implantation
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 26 Sep 2024.
Related trials for Diseases of Mitral and Aortic Valves
Not yet recruiting
Importance of Point-of-Care Ultrasound for Early Detection of Valvular and Cardiac Diseases (IMPROVE)
Valvular Heart Disease Patients, Aortic Stenosis
RecruitingObservational study
Korea VHD Echo Study: Surveillance of Aortic, Mitral & Tricuspid Patients - Insights From Real-world Practice
Heart Valve Diseases, Aortic Valve Stenosis
Active, not recruitingObservational study
Expanded Studies on the SCAPIS Stockholm Reexamination Cohort
Coronary Artery Disease, Arterial Stiffness, Blood Pressure
RecruitingObservational study
Assessment of Exercise Capacity, Muscle Oxygenation and Aortic Stiffness in Patients With Mitral Stenosis
Mitral Stenosis
Enrolling by invitationObservational study
A Multicenter, International, Prospective and Retrospective, Follow-up Registry to Monitor the Efficacy and Safety of the Occlutech Paravalvular Leak Device (PLD) in Patients With Mitral or Aortic Paravalvular Leaks
Paravalvular Leak
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Alexander Bogachev-Prokofiev, MD, PhD principal investigator
National Medical Research Center named after Academician E.N. Meshalkin
Alexey Evtushenko, MD, PhD principal investigator
Research Institute for Complex Issues of Cardiovascular Diseases
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Diseases of Mitral and Aortic Valves and Rheumatic Disorders of Mitral and Aortic Valves, run by Closed Joint-Stock Company NeoCor at 1 site in Russia.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 26 Sep 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Russia. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Evgeny Bazdyrev (+7 (3842) 644240, clinicresearch@kemcardio.ru), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Long-term safety and durability of the "UniLine" epoxy-treated prosthesis made with xenopericardium in the treatment of isolated mitral and aortic valve diseases (time frame: Up to 12 years from the moment of implantation). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Sep 2024.