Carotid StenosisNCT05845710
Direct Access Carotid Artery Stenting Using the Neuroguard IEP System (PERFORMANCE III)
A study testing Neuroguard IEP Direct System in people with Carotid Stenosis and Carotid Artery Diseases, run by Contego Medical, Inc. at 32 sites in 2 countries.
Trial summary
The PERFORMANCE III study is a prospective, multicenter single-arm, open label study to evaluate the safety and effectiveness of the Neuroguard IEP® Direct System for the treatment of carotid artery stenosis in subjects at elevated risk for carotid endarterectomy (CEA). Read more about this study
- Who is it for?
- Ages 20 to 82 years
- Conditions the study is for
- Carotid Stenosis, Carotid Artery Diseases
- What is being tested?
- Neuroguard IEP Direct System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 178 participants
- Where
- 32 sitesin 2 countries
- Study dates
- 5 Oct 2023to 12 Aug 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 82 years
- All sexes
- No healthy volunteers
- Adult, Older adult
General Inclusion Criteria
- Male and non-pregnant, non-breastfeeding female subjects whose age is ≥ 20 or ≤ 82 years of age.
- Subject is willing and capable of complying with and understands all study protocol requirements, including the specified follow-up visits, and can be contacted by telephone.
- Subject has signed a written informed consent form that has been approved by the local governing Institutional Review Board (IRB) of the respective clinical site.
- Subject is diagnosed with carotid artery stenosis treatable with carotid artery stenting via direct carotid access and is considered a high operative risk for carotid endarterectomy (CEA).
- Subject is diagnosed with either:
- Symptomatic carotid stenosis ≥ 50% as determined by angiography, CTA, or duplex ultrasound. Symptomatic is defined as having stroke, transient ischemic attack (TIA) in the ipsilateral hemisphere supplied by the target vessel carotid lesion or ipsilateral transient monocular blindness (amaurosis fugax) within 180 days prior to the procedure; or
- Asymptomatic carotid stenosis ≥ 70% as determined by angiography, CTA, or duplex ultrasound.
- Subject has a lesion located in the internal carotid artery (ICA) and/or common carotid artery (CCA).
- Subject has a modified Rankin Scale of ≤ 2 at the time of procedure.
- Females of child-bearing potential have a negative pregnancy test within 24 hours prior to the index procedure.
- Subject is willing and able to take dual anti platelet therapy for a minimum of 30 days following the index procedure.
- Subject meets at least one physiologic or one anatomic high-risk criteria.
Anatomic High-Risk Conditions for CEA
- Target lesion at or above C2 (level of jaw). 2. Prior head and neck surgery in the region of the carotid artery. 3. Tracheostomy or tracheostoma. 4. Surgically inaccessible lesion or hostile neck which the investigator deems safe for direct carotid access including but not limited to:
- Prior neck irradiation
- Radial neck dissection
- Cervical spine immobility 5. Prior ipsilateral CEA. 6. Prior cranial nerve injury. 7. Severe tandem lesions. 8. Occlusion of the contralateral CCA or ICA. 9. Severe bilateral ICA stenosis. Physiological High-Risk Conditions for CEA
- Subject is ≥ 70 years of age (maximum 80 years) at the time of enrollment.
- Subject has NYHA Class III or IV congestive heart failure (CHF).
- Subject has chronic obstructive pulmonary disease (COPD) with FEV1 < 50, on intermittent or chronic oxygen therapy, or a resting PO2 of ≤ 60 mmHg (room air). 4 Subject has left ventricular ejection fraction (LVEF) ≤ 35%. 5. Subject has angina class 3 or 4 or unstable angina. 6. Subject has a history of recent myocardial infarction (between 30 days and 6 weeks prior to index the procedure).
- Subject has coronary artery disease with two or more vessels with ≥ 70% stenosis.
- Subject has planned coronary artery bypass grafting (CABG) or peripheral vascular surgery between 31 and 60 days after index procedure.
- Subject has restenosis following a prior carotid endarterectomy (CEA). Angiographic Inclusion Criteria
- Subject has a lesion located in the internal carotid artery (ICA) and/or common carotid artery (CCA).
- Single de novo or restenotic (post carotid endarterectomy [CEA]) target lesion or severe tandem lesions that can be covered by a single Neuroguard stent.
- Target lesion is treatable with a single stent of up to 40 mm in length.
- Index vessel diameter (segment covered by the mid-portion of the stent) is between 4.0 mm and 6.0 mm at the site of the target lesion.
- Distal vessel diameter at the site of Neuroguard filter deployment is between 4.0 mm and 7.0 mm.
- Distal common carotid artery diameter (segment covered by proximal portion of the stent) is between 4.0 mm and 8.0 mm.
- Sufficient landing zone exists in the cervical internal carotid artery distal to the target lesion to allow for the safe and successful deployment of the integrated Neuroguard filter.
- At least 5 cm of atherosclerosis free space in the ipsilateral common carotid artery between the sheath insertion site and the proximal edge of the target lesion.
- Common carotid artery reference diameter is at least 6 mm.
- Target vessel must meet diameter requirements as set forth in the Neuroguard IEP Direct System Instructions for Use (IFU). General Exclusion Criteria
- Life expectancy of less than one year in the opinion of the investigator at the time of enrollment.
- Currently requiring an organ transplantation.
- An evolving acute stroke
- Anticipated or existing potential sources of emboli including left ventricular aneurysm, aortic or mitral mechanical heart valve, severe calcific aortic stenosis (valve area < 1.0 cm2), endocarditis, moderate to severe mitral stenosis, known previously symptomatic patent foramen ovale (PFO), left atrial thrombus, any intracardiac mass.
- Deep being thrombosis (DVT) or pulmonary embolism (PE) treated within the past 12 months.
- Recently (< 60 days) implanted heart valve.
- Subject has experienced any episode of paroxysmal atrial fibrillation or atrial flutter within the past 6 months or has a history of paroxysmal atrial fibrillation or atrial flutter requiring chronic anticoagulation.
- History of chronic atrial flutter or chronic atrial fibrillation.
- Anticoagulation with Phenprocoumon (Marcumar®), warfarin, direct thrombin inhibitors, or anti-Xa agents within 14 days of the index procedure.
- Subject with a known hypercoaguable state.
- Acute febrile illness (temperature ≥ 100.4°F or 38°C) or active infection.
- Subject with a SARS-CoV-2/COVID-19 infection within 21 days prior to the index procedure.
- Acute myocardial infarction < 30 days prior to index procedure.
- Any major surgical procedure (i.e., intraabdominal or intrathoracic surgery or any surgery / interventional procedure involving cardiac or vascular system) 30 days prior to or within 30 days following the index procedure.
- History of disabling stroke with substantial residual disability (modified Rankin score ≥ 3).
- Subject has had a transient ischemic attack (TIA) or amaurosis fugax within 48 hours prior to the index procedure.
- Known severe carotid stenosis contralateral to the target lesion requiring treatment within 30 days of the index procedure.
- Any other neurological deficit not due to stroke that may confound neurological assessments.
- Subject has contralateral laryngeal or vagus nerve injury.
- Subject has severe dementia.
- Subject has intracranial tumor.
- Known hypersensitivity to nitinol or its components (e.g., nickel, titanium).
- History of intracranial hemorrhage within the 12 months prior to the index procedure.
- History of gastrointestinal (GI) bleed within 30 days prior to the index procedure that would interfere with antiplatelet therapy.
- Any condition that precludes proper angiographic assessment or makes direct carotid artery access unsafe (e.g., severe hepatic impairment, malignant hypertension, morbid obesity).
- Subject has less than 5 cm between the direct carotid access site and the proximal edge of the target lesion.
- Known hypersensitivity to contrast media that cannot be adequately premedicated.
- Hemoglobin (Hgb) < 8 gm/dL, platelet count < 100,000, international normalized ratio (INR) > 1.5 (irreversible), or heparin-induced thrombocytopenia.
- Chronic renal insufficiency (serum creatinine > 2.5 mg/dL or estimated GFR < 30 cc/min) or end-stage renal disease on hemodialysis on the day of the index procedure.
- History or current indication of bleeding diathesis or coagulopathy including thrombocytopenia or an inability to receive heparin in amounts sufficient to maintain an activated clotting time (ACT) at ≥ 250 seconds, or uncorrectable severe anemia.
- Contraindication, intollerance or allergy to standard of care study medications, including antiplatelet therapy or aspirin.
- Previously enrolled in this study or currently enrolled in another interventional device or drug study that has not yet reached the primary endpoint.
- Potential for subject non-compliance with protocol-required follow up or antiplatelet medication in the opinion of the investigator.
- Subject is otherwise unsuitable for intervention or surgery in the opinion of the investigator. Angiographic Exclusion Criteria
- Total occlusion of the target carotid artery.
- Previously placed stent in the target vessel or the planned arteriotomy site.
- Excessive circumferential calcification of the target lesion, defined as > 3 mm of thickness of calcification seen in orthogonal views on fluoroscopy or on CTA.
- Qualitative characteristics of ipsilateral common carotid artery, ipsilateral external carotid artery, or target lesion that preclude or make difficult the safe introduction of the direct access sheath.
- Angiographic evidence of a mobile filling defect or fresh thrombus in the target carotid artery.
- Presence of "string sign" of the target lesion (a sub-totally occluded, long segment of the true lumen of the artery with markedly reduced contrast flow).
- Non-atherosclerotic carotid stenosis (e.g., dissection, fibromuscular dysplasia).
- Proximal/ostial CCA stenosis ≥ 50% or intracranial stenosis more severe than the target lesion.
- Subject in whom direct carotid access is not possible, including severe tortuosity or stenosis that requires additional endovascular procedures or that prevents safe and expeditious vascular access.
- Subject with intracranial pathology, that in the opinion of the investigator, makes the patient inappropriate for study participation (e.g., arteriovenous malformation, intracranial tumor, microangiopathy or large vessel cerebral vascular disease, etc.) or that would confound the neurological evaluation.
- Angiographic, CT, MR or ultrasound evidence of atherosclerosis of the common carotid artery that would preclude or make difficult safe placement of the sheath and other endovascular devices to the target artery as needed for carotid stenting.
- Angiographic, CT, MR or ultrasound evidence of severe tortuosity of the cervical internal carotid artery. Severe vascular tortuosity is defined as 2 or more bends of 90 degrees or more within 4 cm of the target lesion.
- Angiographic, CT, MR or ultrasound evidence of angulation or tortuosity (≥ 90 degree) of the common carotid artery (CCA) that will transmit a severe loop to the internal carotid after sheath placement.
- Subject with > 50% stenosis in the common carotid artery (CCA) proximal to the target lesion.
Trial locations and contacts
32 sites in 2 countries.
32 sites in 2 countries
United States30 sites
St. David's Healthcare
Austin, Texas, 78756
McLaren Center for Research and Innovation
Bay City, Michigan, 48708
Manatee Memorial Hospital
Bradenton, Florida, 34208
University at Buffalo Neurosurgery - Jacobs Institute
Buffalo, New York, 14203
Sisters of Charity Hospital
Buffalo, New York, 14214
UNC Hospital
Chapel Hill, North Carolina, 27514
Medical University of South Carolina
Charleston, South Carolina, 29425
Atrium Health - Sanger Heart and Vascular
Charlotte, North Carolina, 28204
TriHealth (Bethesda North Hospital)
Cincinnati, Ohio, 45242
Cleveland Clinic
Cleveland, Ohio, 44195
OhioHealth Research Institute
Columbus, Ohio, 43214
Baylor Scott and White Research Institute
Dallas, Texas, 75246
UT Southwestern Medical Center
Dallas, Texas, 75390
Delray Medical Center
Delray Beach, Florida, 33484
Prisma Health
Greenville, South Carolina, 29615
Hackensack University Medical Center
Hackensack, New Jersey, 07601
Hartford Hospital
Hartford, Connecticut, 06102
Indiana University Methodist Hospital
Indianapolis, Indiana, 46202
Northwell Health
Lake Success, New York, 11042
Mount Sinai Vascular Institute
Miami Beach, Florida, 33140
Vanderbilt University
Nashville, Tennessee, 37232-5545
Southcoast Health
New Bedford, Massachusetts, 02720
Mount Sinai Medical Center
New York, New York, 10029
Sentara Norfolk General Hospital
Norfolk, Virginia, 23507
AdventHealth Orlando
Orlando, Florida, 32803
Allegheny General Hospital
Pittsburgh, Pennsylvania, 15212
North Carolina Heart and Vascular Research
Raleigh, North Carolina, 27607
Honor Health
Scottsdale, Arizona, 85258
St. Francis Hospital
Tulsa, Oklahoma, 74136
MedStar Washington Hospital Center
Washington D.C., District of Columbia, 20010
France2 sites
Hopital Marie Lannelongue
Le Plessis-Robinson, 92350
GH Paris St. Joseph
Paris, 75014
About this study
Official title: Protection Against Emboli During caRotid Artery Stenting Using a Neuroguard IEP® Direct 3-in-1 Delivery System Comprised oF a pOst-dilation Balloon, integRated eMbolic Filter, and A Novel Carotid stEnt - the PERFORMANCE III Study
The PERFORMANCE III study is a prospective, multicenter single-arm, open label study to evaluate the safety and effectiveness of the Neuroguard IEP® Direct System for the treatment of carotid artery stenosis in subjects at elevated risk for carotid endarterectomy (CEA).
Eligible patients greater than or equal to 20 years of age and less than or equal to 82 years of age, are those who have been diagnosed with either de-novo atherosclerotic or post CEA restenotic lesion(s) in the internal carotid arteries (ICA) or at the carotid bifurcation with greater than or equal to 50% stenosis if symptomatic or greater than or equal to 70% stenosis if asymptomatic.
Read the detailed description
A prospective, multicenter single-arm, open label study to evaluate the safety and effectiveness of the Neuroguard IEP® Direct System for the treatment of carotid artery stenosis in subjects at elevated risk for adverse events following carotid endarterectomy (CEA). The Neuroguard IEP Direct System is a 3-in-1 carotid stent delivery system consisting of an angioplasty balloon, an integrated embolic protection device and a nitinol self-expanding stent loaded over the balloon and constrained by an outer sheath. Eligible patients greater than or equal to 20 years of age and less than or equal to 80 years of age, are those who have been diagnosed with either de-novo atherosclerotic or post CEA restenotic lesion(s) in the internal carotid arteries (ICA) or at the carotid bifurcation with greater than or equal to 50% stenosis if symptomatic or greater than or equal to 70% stenosis if asymptomatic.
Symptomatic subjects are defined as having stroke or transient ischemic attack (TIA) in the ipsilateral hemisphere supplied by the target vessel carotid lesion or ipsilateral transient monocular blindness (amaurosis fugax) within 180 days prior to the index procedure.
Subjects will be followed for 30 days post index procedure with additional follow up for subjects having a stroke or cranial nerve injury.
- Conditions
- Carotid Stenosis, Carotid Artery Diseases
- Being tested
- Neuroguard IEP Direct System
- Keywords
- carotid artery stent
- Medical subject headings
- Carotid Stenosis, Carotid Artery Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Neuroguard IEP Direct SystemDevice
carotid artery stenting, direct access with blood flow redirection
| Study group | Role | What they receive |
|---|---|---|
| Neuroguard IEP Direct System | Experimental | The Neuroguard IEP® 3-in-1 Direct Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP Direct System) is a combination self-expanding carotid artery stent, nitinol embolic protection filter, and post-dilation balloon. Neuroguard IEP Direct System is used with the Neuroguard Direct Access Kit which includes the Flow Redirection System. Receives: Device: Neuroguard IEP Direct System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Composite of Major Adverse Events (MAE)
The primary endpoint is a composite 30-day rate of Major Adverse Events (MAE), defined as the cumulative incidence of all stroke, myocardial infarction (MI) and death within 30 days of the index procedure.
Measured: Within 30 days of the study procedure
Secondary outcomes (5)
Acute Success
The ability to insert the Neuroguard IEP Direct System, deliver the stent, and remove the stent delivery catheter.
Measured: Procedure
Technical Success
The ability to utilize the accessories provided in the Neuroguard Direct Access Kit to establish flow reversal, defined as visualization of blood in the collection tubing.
Measured: Procedure
Procedure Success
Acute Success and Technical Success in the absence of device related Major Adverse Events (defined as the cumulative incidence of all stroke, myocardial infarction and death) prior to discharge.
Measured: Procedure
Blood Transfusion
Number of subjects requiring blood transfusion from procedure initiation through to discharge.
Measured: Procedure through discharge or within 30 days of the study procedure
Stroke, Death
Ipsilateral, major and minor stroke, all death, cardiac death, neurological death
Measured: Within 30 days of the study procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 May 2023
- Study start5 Oct 2023
- Primary completion12 Aug 2025
- Study completion12 Aug 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Carotid StenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 178 participants (actual)
Sponsor and investigators
- Lead sponsor
- Contego Medical, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Yale Cardiovascular Research Group, CardioMed Device Consultants, LLC, Advance Research Associates, iMedNet, AG Mednet
- Responsible party
- Sponsor
- Investigators
- Sean Lyden, MD, Principal investigator, The Cleveland ClinicD. Christopher Metzger, MD, Principal investigator, OhioHealth Research Institute
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05845710
- Sponsor's protocol ID
- CSP-1997
- Status last verified
- Mar 2026
- First submitted
- 26 Apr 2023
- Last updated
- 6 Mar 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 6 Mar 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Protection Against Emboli During caRotid Artery Stenting Using a Neuroguard IEP® Direct 3-in-1 Delivery System Comprised oF a pOst-dilation Balloon, integRated eMbolic Filter, and A Novel Carotid stEnt - the PERFORMANCE III Study
- ClinicalTrials.gov ID
- NCT05845710
- Acronym / sponsor ID
- CSP-1997
- Conditions
- Carotid Stenosis, Carotid Artery Diseases
- Keywords
- carotid artery stent
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 178 participants (actual)
- Lead sponsor
- Contego Medical, Inc.Industry (pharma, biotech, devices)
- Collaborators
- Yale Cardiovascular Research Group, CardioMed Device Consultants, LLC, Advance Research Associates, iMedNet, AG Mednet
- Study start
- 5 Oct 2023 (actual)
- Primary completion
- 12 Aug 2025 (actual)
- Study completion
- 12 Aug 2025 (actual)
- First posted
- 6 May 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The PERFORMANCE III study is a prospective, multicenter single-arm, open label study to evaluate the safety and effectiveness of the Neuroguard IEP® Direct System for the treatment of carotid artery stenosis in subjects at elevated risk for carotid endarterectomy (CEA).
Eligible patients greater than or equal to 20 years of age and less than or equal to 82 years of age, are those who have been diagnosed with either de-novo atherosclerotic or post CEA restenotic lesion(s) in the internal carotid arteries (ICA) or at the carotid bifurcation with greater than or equal to 50% stenosis if symptomatic or greater than or equal to 70% stenosis if asymptomatic.
Detailed description
A prospective, multicenter single-arm, open label study to evaluate the safety and effectiveness of the Neuroguard IEP® Direct System for the treatment of carotid artery stenosis in subjects at elevated risk for adverse events following carotid endarterectomy (CEA). The Neuroguard IEP Direct System is a 3-in-1 carotid stent delivery system consisting of an angioplasty balloon, an integrated embolic protection device and a nitinol self-expanding stent loaded over the balloon and constrained by an outer sheath. Eligible patients greater than or equal to 20 years of age and less than or equal to 80 years of age, are those who have been diagnosed with either de-novo atherosclerotic or post CEA restenotic lesion(s) in the internal carotid arteries (ICA) or at the carotid bifurcation with greater than or equal to 50% stenosis if symptomatic or greater than or equal to 70% stenosis if asymptomatic.
Symptomatic subjects are defined as having stroke or transient ischemic attack (TIA) in the ipsilateral hemisphere supplied by the target vessel carotid lesion or ipsilateral transient monocular blindness (amaurosis fugax) within 180 days prior to the index procedure.
Subjects will be followed for 30 days post index procedure with additional follow up for subjects having a stroke or cranial nerve injury.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Neuroguard IEP Direct System | Experimental | Device: Neuroguard IEP Direct SystemThe Neuroguard IEP® 3-in-1 Direct Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP Direct System) is a combination self-expanding carotid artery stent, nitinol embolic protection filter, and post-dilation balloon. Neuroguard IEP Direct System is used with the Neuroguard Direct Access Kit which includes the Flow Redirection System. |
Who may qualify
- Ages
- 20 to 82 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Neuroguard IEP Direct Systemcarotid artery stenting, direct access with blood flow redirection | Device | Neuroguard IEP Direct System |
Primary outcome
Composite of Major Adverse Events (MAE)
Time frame: Within 30 days of the study procedure
The primary endpoint is a composite 30-day rate of Major Adverse Events (MAE), defined as the cumulative incidence of all stroke, myocardial infarction (MI) and death within 30 days of the index procedure.
5 secondary outcomes
Acute Success
Time frame: Procedure
Technical Success
Time frame: Procedure
Procedure Success
Time frame: Procedure
Blood Transfusion
Time frame: Procedure through discharge or within 30 days of the study procedure
Stroke, Death
Time frame: Within 30 days of the study procedure
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Mar 2026.
Related trials for Carotid Stenosis
Active, not recruitingObservational study
Symptomatic Carotid Outcomes Registry
Carotid Stenosis, Ischemic Stroke
Not yet recruitingObservational study
PET-MR Imaging of Natriuretic Peptide Receptor C (NPR-C) in Carotid Atherosclerosis With 64Cu-NODAGA-CANF (Multisite)
Carotid Atherosclerosis, Carotid Artery Stenosis Asymptomatic
Not yet recruitingObservational study
A Prospective, Multicenter, Single Arm Registry of ENROUTE NPS in Conjunction With Carotid WALLSTENT in Chinese Population
Carotid Artery Stenosis
Not yet recruitingObservational study
Vascular Health and Function in Cystic Fibrosis
Cystic Fibrosis, Endothelial Dysfunction
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Sean Lyden, MD principal investigator
The Cleveland Clinic
D. Christopher Metzger, MD principal investigator
OhioHealth Research Institute
32 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Neuroguard IEP Direct System in people with Carotid Stenosis and Carotid Artery Diseases, run by Contego Medical, Inc. at 32 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 32 sites in United States, France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Composite of Major Adverse Events (MAE) (time frame: Within 30 days of the study procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Mar 2026.