CorneaCSCLNCT05745220
Influence of Silicone Hydrogel Contact Lens Neophyte Wear on Corneal Sensitivity
A study testing Device: silicone hydrogel contact lens in people with Cornea, run by Daniela Nosch at 1 site in Switzerland.
Trial summary
Soft contact lenses can affect the ocular surface and sometimes cause intolerance. The aim of this study is to measure corneal sensitivity using the Swiss Liquid Jet aesthesiometer at baseline, after one and after six weeks, in novice daily contact lens wearers. Read more about this study
- Who is it for?
- Ages 18 to 38 yearsHealthy volunteers can take part
- Conditions the study is for
- Cornea
- What is being tested?
- Device: silicone hydrogel contact lens
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 42 participants
- Where
- 1 siteSwitzerland
- Study dates
- 8 Apr 2023to 30 Sep 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 38 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- The Ocular Surface Disease Index questionnaire (OSDI) score for dry eye classification is ≤ 13
- Participants must be candidates for contact lens wear.
- Corneal radius between 7.4mm and 8.0mm
- If the corneal radius is > 8.0mm, the corneal diameter must be greater than 12.0mm.
- If the corneal radius is <7.4mm, the required corneal diameter is less than 12.0mm.
- Participants have a CL cylindrical ametropia ≤ -1.25 D.
Show all 10Show fewer
- Participants will not have worn CL for 7 days prior to the start of the study.
- Participants do not wear CL regularly (no more than 1 days per week) prior to the start of the study.
- During the study, the participant wore the CL a minimum of 5 days per week for a minimum of 8 hours.
- The person being tested is in good health. This means that he or she does not suffer from any systemic diseases, such as diabetes or rheumatism, which could have an influence on eye health. He or she also has no eye disease and has not previously undergone corneal (refractive) surgery.
Who cannot join
- The participant is a minor.
- The participant has worn CL within the last 7 days.
- The radius of the cornea is not within the prescribed range. In addition, the corneal diameter is not within the prescribed range either.
- The participant's ametropia is not within the prescribed range.
- The participant has worn the lenses for less than 8 hours for less than five days.
- The participant has no diagnosis of dry eye.
Show all 9Show fewer
- The OSDI questionnaire score for the Dry Eye classification is greater than 13.
- The participant suffers from a systemic disease (diabetes or rheumatism) that could influence ocular health, an ocular disease or has already undergone refractive surgery.
- Vulnerable participants
Trial locations and contacts
1 site in 1 country.
Switzerland1 site
Optique Messerli Optometry centre
Marly, Canton of Fribourg, 1723
About this study
Official title: Corneal Sensitivity in Silicone Hydrogel Contact Lens Wear
Soft contact lenses can affect the ocular surface and sometimes cause intolerance. The aim of this study is to measure corneal sensitivity using the Swiss Liquid Jet aesthesiometer at baseline, after one and after six weeks, in novice daily contact lens wearers.
Read the detailed description
Contact lens discomfort is described by many wearers. Wearing contact lenses can influence corneal sensitivity through three mechanisms: hypoxic, mechanical and inflammatory. A change in corneal sensitivity can be considered an indicator of a change in corneal physiology. Corneal sensitivity plays a major role in maintaining eye health. The interest of this study is to test the variability of the corneal sensitivity threshold during a new adaptation of silicone hydrogel contact lenses, and to verify whether there is a correlation with the wearer's comfort. For that, corneal sensitivity threshold measurements are taken at the baseline and then after one and six weeks of daily contact lens wear. The measurement is performed with the Swiss Liquid Jet aesthesiometer for corneal sensitivity (SLACS). After one week and six weeks of daily lens wear, participants complete a Contact Lens Dry Eye Questionnaire (CLDEQ-8) for comfort analysis.
- Conditions
- Cornea
- Being tested
- Device: silicone hydrogel contact lens
- Keywords
- silicone hydrogel contact lens, daily contact lens wear, corneal sensitivity, esthesiometry
- Medical subject headings
- Corneal Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Device: silicone hydrogel contact lensOther
Silicone hydrogel contact lens
| Study group | Role | What they receive |
|---|---|---|
| Daily contact lens wear | Other | Participant wear silicone hydrogel contact lenses daily for 6 weeks ±2 days for a minimum wearing time of 5 days per week and 8 hours per day - corneal sensitivity will be measured and compared at baseline versus after 7±2 days and 5 weeks ±2 days daily contact lens wear. Receives: Other: Device: silicone hydrogel contact lens |
What is being measured
The primary outcome is the main question the study is designed to answer.
Difference in corneal sensitivity threshold baseline and after one and six weeks of daily contact lens wear
Comparison of corneal sensitivity threshold at the baseline and after one and six weeks of daily wear of silicone hydrogel contact lenses on neophyte wearer. Corneal sensitivity measurement will take place with the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and will be recorded in mbar.
Measured: 7±2 days and 5 weeks ±2
Secondary outcomes (1)
Correlation between corneal sensitivity threshold and subjective symptoms
Correlation between corneal sensitivity threshold and subjective symptoms after one and six weeks of daily contact lens wear: corneal sensitivity threshold will be determined with the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and will be recorded in mbar. Subjective Symptoms will be recorded with the Contact Lens Dry Eye Questionnaire (CLDEQ-8) scored from 0=comfortable to 37=uncomfortable (specifically designed to assess contact lens comfort)
Measured: 7±2 days and 5 weeks ±2
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted27 Feb 2023
- Study start8 Apr 2023
- Primary completion30 Sep 2023
- Study completion30 Sep 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for CorneaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Single Group Assignment
- Masking
- None (open label)
- Enrolment
- 42 participants (actual)
Sponsor and investigators
- Lead sponsor
- Daniela Nosch
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Daniela Nosch, University of Applied Sciences and Arts Northwestern Switzerland
- Investigators
- Daniela Nosch, PhD, Principal investigator, Institute of Optometry, FHNW
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05745220
- Sponsor's protocol ID
- 2022-D0124
- Acronym
- CSCL
- Status last verified
- Feb 2024
- First submitted
- 16 Feb 2023
- Last updated
- 26 Feb 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Belmonte C, Acosta MC, Gallar J. Neural basis of sensation in intact and injured corneas. Exp Eye Res. 2004 Mar;78(3):513-25. doi: 10.1016/j.exer.2003.09.023.
PubMed 15106930Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye. 2021 Apr;44(2):192-219. doi: 10.1016/j.clae.2021.02.006. Epub 2021 Mar 25.
PubMed 33775377Muller LJ, Marfurt CF, Kruse F, Tervo TM. Corneal nerves: structure, contents and function. Exp Eye Res. 2003 May;76(5):521-42. doi: 10.1016/s0014-4835(03)00050-2.
PubMed 12697417Nosch DS, Oscity M, Steigmeier P, Kaser E, Loepfe M, Joos RE. Working principle and relevant physical properties of the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) evaluation. Ophthalmic Physiol Opt. 2022 May;42(3):609-618. doi: 10.1111/opo.12962. Epub 2022 Feb 14.
PubMed 35156726Stapleton F, Marfurt C, Golebiowski B, Rosenblatt M, Bereiter D, Begley C, Dartt D, Gallar J, Belmonte C, Hamrah P, Willcox M; TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology. Invest Ophthalmol Vis Sci. 2013 Oct 18;54(11):TFOS71-97. doi: 10.1167/iovs.13-13226.
PubMed 24058137Nichols JJ, Willcox MD, Bron AJ, Belmonte C, Ciolino JB, Craig JP, Dogru M, Foulks GN, Jones L, Nelson JD, Nichols KK, Purslow C, Schaumberg DA, Stapleton F, Sullivan DA; members of the TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: executive summary. Invest Ophthalmol Vis Sci. 2013 Oct 18;54(11):TFOS7-TFOS13. doi: 10.1167/iovs.13-13212. No abstract available.
PubMed 24058135
Study at a glance
From the registry record, last updated by the sponsor on 26 Feb 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Corneal Sensitivity in Silicone Hydrogel Contact Lens Wear
- ClinicalTrials.gov ID
- NCT05745220
- Acronym / sponsor ID
- CSCL / 2022-D0124
- Conditions
- Cornea
- Keywords
- silicone hydrogel contact lens, daily contact lens wear, corneal sensitivity, esthesiometry
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 42 participants (actual)
- Lead sponsor
- Daniela NoschUniversity, hospital or other
- Study start
- 8 Apr 2023 (actual)
- Primary completion
- 30 Sep 2023 (actual)
- Study completion
- 30 Sep 2023 (actual)
- First posted
- 27 Feb 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Soft contact lenses can affect the ocular surface and sometimes cause intolerance. The aim of this study is to measure corneal sensitivity using the Swiss Liquid Jet aesthesiometer at baseline, after one and after six weeks, in novice daily contact lens wearers.
Detailed description
Contact lens discomfort is described by many wearers. Wearing contact lenses can influence corneal sensitivity through three mechanisms: hypoxic, mechanical and inflammatory. A change in corneal sensitivity can be considered an indicator of a change in corneal physiology. Corneal sensitivity plays a major role in maintaining eye health. The interest of this study is to test the variability of the corneal sensitivity threshold during a new adaptation of silicone hydrogel contact lenses, and to verify whether there is a correlation with the wearer's comfort. For that, corneal sensitivity threshold measurements are taken at the baseline and then after one and six weeks of daily contact lens wear. The measurement is performed with the Swiss Liquid Jet aesthesiometer for corneal sensitivity (SLACS). After one week and six weeks of daily lens wear, participants complete a Contact Lens Dry Eye Questionnaire (CLDEQ-8) for comfort analysis.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Single Group Assignment
| Arm | Type | Receives |
|---|---|---|
| Daily contact lens wear | Other | Other: Device: silicone hydrogel contact lensParticipant wear silicone hydrogel contact lenses daily for 6 weeks ±2 days for a minimum wearing time of 5 days per week and 8 hours per day - corneal sensitivity will be measured and compared at baseline versus after 7±2 days and 5 weeks ±2 days daily contact lens wear. |
Who may qualify
- Ages
- 18 to 38 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (10 listed)
- The Ocular Surface Disease Index questionnaire (OSDI) score for dry eye classification is ≤ 13
- Participants must be candidates for contact lens wear.
- Corneal radius between 7.4mm and 8.0mm
- If the corneal radius is > 8.0mm, the corneal diameter must be greater than 12.0mm.
- If the corneal radius is <7.4mm, the required corneal diameter is less than 12.0mm.
Key exclusion criteria (9 listed)
- The participant is a minor.
- The participant has worn CL within the last 7 days.
- The radius of the cornea is not within the prescribed range. In addition, the corneal diameter is not within the prescribed range either.
- The participant's ametropia is not within the prescribed range.
- The participant has worn the lenses for less than 8 hours for less than five days.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Device: silicone hydrogel contact lensSilicone hydrogel contact lens | Other | Daily contact lens wear |
Primary outcome
Difference in corneal sensitivity threshold baseline and after one and six weeks of daily contact lens wear
Time frame: 7±2 days and 5 weeks ±2
Comparison of corneal sensitivity threshold at the baseline and after one and six weeks of daily wear of silicone hydrogel contact lenses on neophyte wearer. Corneal sensitivity measurement will take place with the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and will be recorded in mbar.
1 secondary outcome
Correlation between corneal sensitivity threshold and subjective symptoms
Time frame: 7±2 days and 5 weeks ±2
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 26 Feb 2024.
- Background: PubMed 15106930Belmonte C, Acosta MC, Gallar J. Neural basis of sensation in intact and injured corneas. Exp Eye Res. 2004 Mar;78(3):513-25. doi: 10.1016/j.exer.2003.09.023.
- Background: PubMed 33775377Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye. 2021 Apr;44(2):192-219. doi: 10.1016/j.clae.2021.02.006. Epub 2021 Mar 25.
- Background: PubMed 12697417Muller LJ, Marfurt CF, Kruse F, Tervo TM. Corneal nerves: structure, contents and function. Exp Eye Res. 2003 May;76(5):521-42. doi: 10.1016/s0014-4835(03)00050-2.
- Background: PubMed 35156726Nosch DS, Oscity M, Steigmeier P, Kaser E, Loepfe M, Joos RE. Working principle and relevant physical properties of the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) evaluation. Ophthalmic Physiol Opt. 2022 May;42(3):609-618. doi: 10.1111/opo.12962. Epub 2022 Feb 14.
- Background: PubMed 24058137Stapleton F, Marfurt C, Golebiowski B, Rosenblatt M, Bereiter D, Begley C, Dartt D, Gallar J, Belmonte C, Hamrah P, Willcox M; TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology. Invest Ophthalmol Vis Sci. 2013 Oct 18;54(11):TFOS71-97. doi: 10.1167/iovs.13-13226.
- Background: PubMed 24058135Nichols JJ, Willcox MD, Bron AJ, Belmonte C, Ciolino JB, Craig JP, Dogru M, Foulks GN, Jones L, Nelson JD, Nichols KK, Purslow C, Schaumberg DA, Stapleton F, Sullivan DA; members of the TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: executive summary. Invest Ophthalmol Vis Sci. 2013 Oct 18;54(11):TFOS7-TFOS13. doi: 10.1167/iovs.13-13212. No abstract available.
- Individual participant dataSharing planned: No
Related trials for Cornea
Active, not recruitingPhase 3
Descemet Endothelial Thickness Comparison Trial II
Fuchs, Fuchs Dystrophy
RecruitingObservational study
National Ophthalmic Genotyping and Phenotyping Network (eyeGENE (Registered Trademark)), Stage 3 - Expansion of DNA and Data Repositories for Rare Inherited Ophthalmic Diseases
Inherited Ophthalmic Diseases, Hypopigmentation Disorder
RecruitingObservational study
Validation of Interleukins and Other Cytokines Together With OCT Imaging for Rapid Infectious Keratitis Assessment
Keratitis Bacterial, Keratitis Fungal
Not yet recruiting
A Single-Center Clinical Study Evaluating the Efficacy and Safety of Allogeneic Natural Killer (NK) Cell Transplantation for Mooren's Ulcer
Cornea Disease
Recruiting
4D Duke Microscope Integrated Optical Coherence Tomography in a Zeiss Artevo 800
Corneal Diseases, Retinal Diseases
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Daniela Nosch, PhD principal investigator
Institute of Optometry, FHNW
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Device: silicone hydrogel contact lens in people with Cornea, run by Daniela Nosch at 1 site in Switzerland.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 10 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 26 Feb 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Difference in corneal sensitivity threshold baseline and after one and six weeks of daily contact lens wear (time frame: 7±2 days and 5 weeks ±2). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05745220, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Feb 2024.