Patients Undergoing Transurethral Prostate or Cystectomy Under Spinal AnesthesiaNCT05591469

Respiratory Measurement Using Infrared Camera and Electrical Impedance Tomography for Sedation in Patients Undergoing TURP/TURB Under Spinal Anesthesia

A study testing IR Camera and Electrical Impedance Tomography in people with Patients Undergoing Transurethral Prostate or Cystectomy Under Spinal Anesthesia, run by Yonsei University at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Tidal volume may be the most important technical indicator for ventilation. Measuring tidal volume can be used as an indicator of how effective a patient's gas exchange is, and can also be used as a predictive indicator to indirectly predict the severity of respiratory disease. Read more about this study

Who is it for?
Ages 19 to 99 years, men only
What is being tested?
IR Camera and Electrical Impedance Tomography
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteSouth Korea
Study dates
1 Sep 2022to Nov 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 19 to 99 years
  • Men only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • A male aged 19 years or older
  • normal BMI
  • patients undergoing transurethral prostate or cystectomy under spinal anesthesia

Who cannot join

  • Presenting alteration in respiratory function detected by functional analysis of lung volume and capacity- pneumonectomy patient, severe ipsilateral destroyed lung patient
  • Inability to understand or perform the procedure.
  • ASA class 4, 5

Trial locations and contacts

1 site in 1 country.

South Korea1 site, 1 recruiting
  • Yonsei University Health System, Severance Hospital

    Seoul

    Jeongmin Kim, +82 10-8926-2684, ANESJEONGMIN@yuhs.ac

    Recruiting

Other trials in South Korea

About this study

Tidal volume may be the most important technical indicator for ventilation. Measuring tidal volume can be used as an indicator of how effective a patient's gas exchange is, and can also be used as a predictive indicator to indirectly predict the severity of respiratory disease. This tidal volume can be measured using spirometry and pneumotachograph, and the lung function of the patient can be assessed directly or indirectly through the respiratory volume and air flow velocity. In addition, the measurement itself can change the patient's breathing pattern, and for accurate measurement, it has to be carried out in a certain space, so there is a limitation in that it is difficult to measure in a hospital bed or in a laboratory. To overcome this limitation, various methods have been introduced. The basic principle is that the tidal volume is directly proportional to the movement of the chest and proportional to the change in the length of the circumference of the chest. Over the past decade, several studies have been conducted to measure respiratory mechanics in a non-invasive way. Methods using thoracic impedance, acoustic monitoring, strain gauges, and magnetometers have been developed. Non-invasive, non-contact imaging methods have also been developed, such as thermal image, structured light plethysmography (SLP), and optoelectronic plethysmography (OEP). Therefore, in this study, the thoracic movement due to respiration was measured with a non-invasive method (IR camera), and the accuracy was compared through the impedance change obtained through impedance tomography to evaluate the effectiveness of the non-invasive equipment.

Being tested
IR Camera, Electrical Impedance Tomography

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • IR CameraDevice

    the respiration parameters are measured using an IR camera.

  • Electrical Impedance TomographyDevice

    the respiration parameters are measured using an electrical impedance tomograhy.

Study groups in NCT05591469
Study groupRoleWhat they receive
Noncontact Respiration monitoring groupExperimentalNot described
Receives: Device: IR Camera
Contact Respiration monitoring groupExperimentalNot described
Receives: Device: Electrical Impedance Tomography

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The accuracy of respiration measurements

    The accuracy respiration measurements between IR camera and electrical impedance tomography.

    Measured: Experiment period about 20 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Oct 2022
  2. Study start1 Sep 2022
  3. Primary completionNov 2022 (estimated)
  4. Study completionNov 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05591469
Sponsor's protocol ID
4-2022-0864
Status last verified
Oct 2022
First submitted
13 Oct 2022
Last updated
24 Oct 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Kim J, Kwon JH, Kim E, Yoo SK, Shin CS. Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia. J Clin Monit Comput. 2019 Aug;33(4):647-656. doi: 10.1007/s10877-018-0214-4. Epub 2018 Nov 14.

    PubMed 30426322
  • Kwon J, Kwon O, Oh K, Kim J, Shin CS, Yoo SK. Thermodiluted relative tidal volume estimation using a thermal camera in operating room under spinal anesthesia. Biomed Eng Online. 2022 Sep 7;21(1):64. doi: 10.1186/s12938-022-01028-0.

    PubMed 36071495

Questions about this trial

What is this clinical trial studying?

A study testing IR Camera and Electrical Impedance Tomography in people with Patients Undergoing Transurethral Prostate or Cystectomy Under Spinal Anesthesia, run by Yonsei University at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 24 Oct 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Jeongmin Kim (+82 10-8926-2684, ANESJEONGMIN@yuhs.ac), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The accuracy of respiration measurements (time frame: Experiment period about 20 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05591469, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Oct 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in