Urinary IncontinenceNCT05506124
Airbag-type Stretchable Electrode Array(ASEA) for Electrical Stimulation in Urinary Incontinence in Postmenopausal Women
A study testing airbag-type stretchable electrode array (ASEA) device and two-channel hard electrode device in people with Urinary Incontinence and Pelvic Floor Muscle Training, run by Zhenwei Xie at 1 site in China.
Trial summary
The prevalence of urinary incontinence increases after the menopause and affects between 38 % and 55 % of women aged over 60 years. Urinary incontinence has a profound impact on quality of life. Pelvic floor muscle training is the first-line management for urinary incontinence. Read more about this study
- Who is it for?
- Ages 40 to 70 years, women only
- Conditions the study is for
- Urinary Incontinence, Pelvic Floor Muscle Training
- What is being tested?
- airbag-type stretchable electrode array (ASEA) device and two-channel hard electrode device
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 58 participants
- Where
- 1 siteChina
- Study dates
- 1 Sep 2022to 31 Dec 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 40 to 70 years
- Women only
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Clinical diagnosis of UI
- Have a history of sex
- Menopause≥1 year
Who cannot join
- Acute reproductive organ inflammation
- With cardiac pacemakers
- Malignant tumors
- History of pelvic radiotherapy
- Pelvic floor surgery≤6 months
- Any disease or symptom that may affect the implementation of the study or the interpretation of the results
- Participate in other clinical trials at the same time
Trial locations and contacts
1 site in 1 country.
China1 site, 1 recruiting
- Recruiting
Women's Hospital School of Medicine Zhejiang University
Hangzhou, Zhejiang, 310000
Zhenwei Xie, MD, 8613588030456, xiezw@zju.edu.cn
Zujuan Zhang, PhD, 8618868728206, 5312056@zju.edu.cn
About this study
Official title: Gynecology Department of Women's Hospital School of Medicine Zhejiang University
The prevalence of urinary incontinence increases after the menopause and affects between 38 % and 55 % of women aged over 60 years. Urinary incontinence has a profound impact on quality of life.
Pelvic floor muscle training is the first-line management for urinary incontinence. Electrical stimulation is considered for improving contraction of pelvic floor muscles and aid motivation and adherence to therapy and commonly used in pelvic floor muscle training in clinic therapy. However, the stability and quality of the signals collected by existing stretchable electronics (two-channel hard electrode) are too poor especially when muscle movement is involved, making them inappropriate for aureate pelvic floor muscle training. Here, we propose a physiology-based design method for the stretchable electronics and a novel airbag-type stretchable electrode array (ASEA) device for pelvic floor muscle training.
Read more
In this study, the investigators hypothesis that ASEA is effective in controlling UI. A randomized, open, and controlled study will be implemented. "participants with ASEA will be included and be prescribed.
Two-channel hard electrode as electrical stimulation electrode will be used as positive control.The primary efficacy end points is the reduction of symptom scoring and improving of quality-of-life assessment, the frequency of UI at 12th week assessed with bladder diaries and pad testing, and the quality-of-life assessed with incontinence impact questionnaire short form (IIQ-7) and pelvic organ prolapsed-urinary incontinence sexual questionnaire-12(PISQ-12).
The adverse event and medication compliance will be investigated. The aim of this study is to explore the efficacy, safety and therapy of ASEA as electrical stimulation electrode in management of UI. This study will provide new options of electrode for the electrical stimulation in management of UI, which will help improve precision therapy of UI.
Read the detailed description
The prevalence of the condition increases with age, and it is reported to affect 58%-84% of elderly women. Pelvic floor muscle training is the first-line management for urinary incontinence. Electrical stimulation is considered for improving contraction of pelvic floor muscles and aid motivation and adherence to therapy and commonly used in pelvic floor muscle training in clinic therapy. However, the stability and quality of the existing stretchable electronics are too poor especially when muscle movement is involved, making them inappropriate for high standard clinical treatment. Here, we propose a novel airbag-type stretchable electrode array (ASEA) device for training of the female pelvic floor muscle (PFM) for the treatment of UI. The aim of this study is to explore the efficacy and safety of in management of UI. In this study, the investigators hypothesis that ASEA device therapy is effective in controlling UI. A randomized, open, and controlled study will be implemented. Subjects were recruited in strict accordance the inclusion and exclusion criteria at the outpatient clinic. Patients with UI with Ingelman sundberg graduation (mild, moderate, moderate)≥mild UI will be included. Eligible subjects were randomized according to a computer-generated randomization schedule to to receive two-channel hard electrode or ASEA in a ratio of 1:1. Specific doctors will be designated for the disease diagnosis and treatment.
The investigators were guided by Urinary incontinence and pelvic organ prolapse in women: management (NICE guideline,2019). The primary efficacy end points is the reduction of symptom scoring and improving of quality-of-life assessment. Bladder diaries and pad testing will be to performed to evaluate the frequency and quantify urine loss. The quality-of-life assessed with incontinence impact questionnaire short form (IIQ-7) and pelvic organ prolapsed- urinary incontinence sexual questionnaire-12 (PISQ-12), the higher the score, the greater the impact on the quality of life.
The specification of the CONSORT case report system will be implemented. Sample size assessment according equivalence study. Follow-up and loss cases were strictly controlled. A two-sided test will performed with beta=0.80 and αlpha=0.05. The expected loss rate is calculated at 10%. 29 cases will be enrolled with 58 cases in each group. The study will be accepted regular monitoring and inspection.
- Conditions
- Urinary Incontinence, Pelvic Floor Muscle Training
- Being tested
- airbag-type stretchable electrode array (ASEA) device, two-channel hard electrode device
- Keywords
- Urinary incontinence, Pelvic floor muscle training, Pelvic Floor Muscle Electrical Stimulation, Stretchable electronics
- Medical subject headings
- Urinary Incontinence
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
airbag-type stretchable electrode array (ASEA) deviceDevice
Propose a novel airbag-type stretchable electrode array (ASEA) device for electrical stimulation for training of the female pelvic floor muscle (PFM) for the treatment of UI
two-channel hard electrode deviceDevice
Propose a two-channel hard electrode device for electrical stimulation for training of the female pelvic floor muscle (PFM) for the treatment of UI
| Study group | Role | What they receive |
|---|---|---|
| group 1 | Experimental | Propose a novel airbag-type stretchable electrode array (ASEA) device for training of the female pelvic floor muscle (PFM) for the treatment of UI Receives: Device: airbag-type stretchable electrode array (ASEA) device |
| group 2 | Active comparator | Propose a two-channel hard electrode device for training of the female pelvic floor muscle (PFM) for the treatment of UI Receives: Device: two-channel hard electrode device |
What is being measured
The primary outcome is the main question the study is designed to answer.
The change of quality of life
Use a validated urinary incontinence-specific symptom and quality-of-life questionnaire as follows: Urinary incontinence impact questionnaire IIQ-7, Pelvic organ prolapse / urinary incontinence sexual function questionnaire PISQ-12, Each questionnaire the maximum score is 100 and the minimum score is 0, the higher the score, the worse quality of life.
Measured: Baseline score, Change from Baseline score at 12 weeks
The change of quantify urine loss
The change of urine loss measured by pad test. A pad weight gain≥ 2 g is positive. Mild: 2 g≤ weight gain <5 g; Moderate: 5 g ≤ weight gain < 10 g; Severe: 10 g ≤ weight gain < 50 g; extremely severe Degree: weight gain≥ 50 g. The increasing of weight gain means UI aggravation, while the reduction of weight gain means effective.
Measured: Baseline weight gain, Change from Baseline weight gain at 12 weeks
Secondary outcomes (1)
The change of symptom scoring
Bladder diaries to record the frequency of symptom scoring. The increasing of frequency of symptom scoring means UI aggravation, while the reduction of frequency of symptom scoring means effective.
Measured: Baseline frequency of symptom scoring, Change from Baseline frequency of symptom scoring at 12 weeks
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted18 Aug 2022
- Study start1 Sep 2022
- Primary completion30 Sep 2024 (estimated)
- Study completion31 Dec 2024 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Urinary IncontinenceStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 58 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Zhenwei Xie
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Zhenwei Xie, Women's Hospital School Of Medicine Zhejiang University
- Investigators
- Zhenwei Xie, MD, Principal investigator, Zhejiang University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05506124
- Sponsor's protocol ID
- ZDFY2021-4X102
- Status last verified
- Apr 2023
- First submitted
- 22 Feb 2022
- Last updated
- 27 Apr 2023
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Wu JM, Vaughan CP, Goode PS, Redden DT, Burgio KL, Richter HE, Markland AD. Prevalence and trends of symptomatic pelvic floor disorders in U.S. women. Obstet Gynecol. 2014 Jan;123(1):141-148. doi: 10.1097/AOG.0000000000000057.
PubMed 24463674Zuchelo LTS, Bezerra IMP, Da Silva ATM, Gomes JM, Soares Junior JM, Chada Baracat E, de Abreu LC, Sorpreso ICE. Questionnaires to evaluate pelvic floor dysfunction in the postpartum period: a systematic review. Int J Womens Health. 2018 Aug 8;10:409-424. doi: 10.2147/IJWH.S164266. eCollection 2018.
PubMed 30123009Tinelli A, Malvasi A, Rahimi S, Negro R, Vergara D, Martignago R, Pellegrino M, Cavallotti C. Age-related pelvic floor modifications and prolapse risk factors in postmenopausal women. Menopause. 2010 Jan-Feb;17(1):204-12. doi: 10.1097/gme.0b013e3181b0c2ae.
PubMed 19629013Koenig I, Luginbuehl H, Radlinger L. Reliability of pelvic floor muscle electromyography tested on healthy women and women with pelvic floor muscle dysfunction. Ann Phys Rehabil Med. 2017 Nov;60(6):382-386. doi: 10.1016/j.rehab.2017.04.002. Epub 2017 Jul 14.
PubMed 28716538
Study at a glance
From the registry record, last updated by the sponsor on 27 Apr 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Gynecology Department of Women's Hospital School of Medicine Zhejiang University
- ClinicalTrials.gov ID
- NCT05506124
- Acronym / sponsor ID
- ZDFY2021-4X102
- Conditions
- Urinary Incontinence, Pelvic Floor Muscle Training
- Keywords
- Urinary incontinence, Pelvic floor muscle training, Pelvic Floor Muscle Electrical Stimulation, Stretchable electronics
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 58 participants (estimated)
- Lead sponsor
- Zhenwei XieUniversity, hospital or other
- Study start
- 1 Sep 2022 (actual)
- Primary completion
- 30 Sep 2024 (estimated)
- Study completion
- 31 Dec 2024 (estimated)
- First posted
- 18 Aug 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The prevalence of urinary incontinence increases after the menopause and affects between 38 % and 55 % of women aged over 60 years. Urinary incontinence has a profound impact on quality of life.
Pelvic floor muscle training is the first-line management for urinary incontinence. Electrical stimulation is considered for improving contraction of pelvic floor muscles and aid motivation and adherence to therapy and commonly used in pelvic floor muscle training in clinic therapy. However, the stability and quality of the signals collected by existing stretchable electronics (two-channel hard electrode) are too poor especially when muscle movement is involved, making them inappropriate for aureate pelvic floor muscle training. Here, we propose a physiology-based design method for the stretchable electronics and a novel airbag-type stretchable electrode array (ASEA) device for pelvic floor muscle training.
In this study, the investigators hypothesis that ASEA is effective in controlling UI. A randomized, open, and controlled study will be implemented. "participants with ASEA will be included and be prescribed.
Two-channel hard electrode as electrical stimulation electrode will be used as positive control.The primary efficacy end points is the reduction of symptom scoring and improving of quality-of-life assessment, the frequency of UI at 12th week assessed with bladder diaries and pad testing, and the quality-of-life assessed with incontinence impact questionnaire short form (IIQ-7) and pelvic organ prolapsed-urinary incontinence sexual questionnaire-12(PISQ-12).
The adverse event and medication compliance will be investigated. The aim of this study is to explore the efficacy, safety and therapy of ASEA as electrical stimulation electrode in management of UI. This study will provide new options of electrode for the electrical stimulation in management of UI, which will help improve precision therapy of UI.
Detailed description
The prevalence of the condition increases with age, and it is reported to affect 58%-84% of elderly women. Pelvic floor muscle training is the first-line management for urinary incontinence. Electrical stimulation is considered for improving contraction of pelvic floor muscles and aid motivation and adherence to therapy and commonly used in pelvic floor muscle training in clinic therapy. However, the stability and quality of the existing stretchable electronics are too poor especially when muscle movement is involved, making them inappropriate for high standard clinical treatment. Here, we propose a novel airbag-type stretchable electrode array (ASEA) device for training of the female pelvic floor muscle (PFM) for the treatment of UI. The aim of this study is to explore the efficacy and safety of in management of UI. In this study, the investigators hypothesis that ASEA device therapy is effective in controlling UI. A randomized, open, and controlled study will be implemented. Subjects were recruited in strict accordance the inclusion and exclusion criteria at the outpatient clinic. Patients with UI with Ingelman sundberg graduation (mild, moderate, moderate)≥mild UI will be included. Eligible subjects were randomized according to a computer-generated randomization schedule to to receive two-channel hard electrode or ASEA in a ratio of 1:1. Specific doctors will be designated for the disease diagnosis and treatment.
The investigators were guided by Urinary incontinence and pelvic organ prolapse in women: management (NICE guideline,2019). The primary efficacy end points is the reduction of symptom scoring and improving of quality-of-life assessment. Bladder diaries and pad testing will be to performed to evaluate the frequency and quantify urine loss. The quality-of-life assessed with incontinence impact questionnaire short form (IIQ-7) and pelvic organ prolapsed- urinary incontinence sexual questionnaire-12 (PISQ-12), the higher the score, the greater the impact on the quality of life.
The specification of the CONSORT case report system will be implemented. Sample size assessment according equivalence study. Follow-up and loss cases were strictly controlled. A two-sided test will performed with beta=0.80 and αlpha=0.05. The expected loss rate is calculated at 10%. 29 cases will be enrolled with 58 cases in each group. The study will be accepted regular monitoring and inspection.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| group 1 | Experimental | Device: airbag-type stretchable electrode array (ASEA) devicePropose a novel airbag-type stretchable electrode array (ASEA) device for training of the female pelvic floor muscle (PFM) for the treatment of UI |
| group 2 | Active comparator | Device: two-channel hard electrode devicePropose a two-channel hard electrode device for training of the female pelvic floor muscle (PFM) for the treatment of UI |
Who may qualify
- Ages
- 40 to 70 years
- Sex
- Female only
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Clinical diagnosis of UI
- Have a history of sex
- Menopause≥1 year
Key exclusion criteria (7 listed)
- Acute reproductive organ inflammation
- With cardiac pacemakers
- Malignant tumors
- History of pelvic radiotherapy
- Pelvic floor surgery≤6 months
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| airbag-type stretchable electrode array (ASEA) devicePropose a novel airbag-type stretchable electrode array (ASEA) device for electrical stimulation for training of the female pelvic floor muscle (PFM) for the treatment of UI | Device | group 1 |
| two-channel hard electrode devicePropose a two-channel hard electrode device for electrical stimulation for training of the female pelvic floor muscle (PFM) for the treatment of UI | Device | group 2 |
Primary outcome
The change of quality of life
Time frame: Baseline score, Change from Baseline score at 12 weeks
Use a validated urinary incontinence-specific symptom and quality-of-life questionnaire as follows: Urinary incontinence impact questionnaire IIQ-7, Pelvic organ prolapse / urinary incontinence sexual function questionnaire PISQ-12, Each questionnaire the maximum score is 100 and the minimum score is 0, the higher the score, the worse quality of life.
The change of quantify urine loss
Time frame: Baseline weight gain, Change from Baseline weight gain at 12 weeks
The change of urine loss measured by pad test. A pad weight gain≥ 2 g is positive. Mild: 2 g≤ weight gain <5 g; Moderate: 5 g ≤ weight gain < 10 g; Severe: 10 g ≤ weight gain < 50 g; extremely severe Degree: weight gain≥ 50 g. The increasing of weight gain means UI aggravation, while the reduction of weight gain means effective.
1 secondary outcome
The change of symptom scoring
Time frame: Baseline frequency of symptom scoring, Change from Baseline frequency of symptom scoring at 12 weeks
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Apr 2023.
- Background: PubMed 24463674Wu JM, Vaughan CP, Goode PS, Redden DT, Burgio KL, Richter HE, Markland AD. Prevalence and trends of symptomatic pelvic floor disorders in U.S. women. Obstet Gynecol. 2014 Jan;123(1):141-148. doi: 10.1097/AOG.0000000000000057.
- Background: PubMed 30123009Zuchelo LTS, Bezerra IMP, Da Silva ATM, Gomes JM, Soares Junior JM, Chada Baracat E, de Abreu LC, Sorpreso ICE. Questionnaires to evaluate pelvic floor dysfunction in the postpartum period: a systematic review. Int J Womens Health. 2018 Aug 8;10:409-424. doi: 10.2147/IJWH.S164266. eCollection 2018.
- Background: PubMed 19629013Tinelli A, Malvasi A, Rahimi S, Negro R, Vergara D, Martignago R, Pellegrino M, Cavallotti C. Age-related pelvic floor modifications and prolapse risk factors in postmenopausal women. Menopause. 2010 Jan-Feb;17(1):204-12. doi: 10.1097/gme.0b013e3181b0c2ae.
- Background: PubMed 28716538Koenig I, Luginbuehl H, Radlinger L. Reliability of pelvic floor muscle electromyography tested on healthy women and women with pelvic floor muscle dysfunction. Ann Phys Rehabil Med. 2017 Nov;60(6):382-386. doi: 10.1016/j.rehab.2017.04.002. Epub 2017 Jul 14.
- Individual participant dataSharing planned: No
Related trials for Urinary Incontinence
Recruiting
Ambulatory Long Length URodynamics Evaluation
Urology, Urinary Bladder, Overactive
Active, not recruiting
APPROVE Trial: Evaluating a Prescription Digital Therapeutic for Treatment of OAB in Women
Overactive Bladder (OAB), Urinary Urgency
Not yet recruiting
Anterior Bridge-Preserving Versus Conventional Early Apical Release in Bipolar Enucleation of the Prostate
Benign Prostatic Hyperplasia, Benign Prostatic Obstruction
Not yet recruiting
Transcutaneous Tibial Nerve Stimulation for Urinary Incontinence After Radical Prostatectomy
Urinary Incontinence (UI), Prostatectomy
Not yet recruiting
Anterior Bridge-Preserving Versus Conventional Early Apical Release During Holmium Laser Enucleation of the Prostate
Benign Prostatic Hyperplasia, Benign Prostatic Obstruction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Zhenwei Xie, MD principal investigator
Zhejiang University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing airbag-type stretchable electrode array (ASEA) device and two-channel hard electrode device in people with Urinary Incontinence and Pelvic Floor Muscle Training, run by Zhenwei Xie at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 27 Apr 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Zhenwei Xie, MD (+8613588030456, xiezw@zju.edu.cn), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The change of quality of life (time frame: Baseline score, Change from Baseline score at 12 weeks). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05506124, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Apr 2023.