AzTrials
AzTrials

Calcification of Coronary ArteryNCT05447585

Coronary Atherectomy System in Patients With Coronary Calcification (CORECT)

A study testing Coronary atherectomy system of Shanghai MicroPort Rhythm and Rotablator Rotational Atherectomy System in people with Calcification of Coronary Artery, run by Shanghai MicroPort Rhythm MedTech Co., Ltd. at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This is a prospective and multicenter clinical investigation aiming to evaluate the safety and effectiveness of coronary atherectomy system for the treatment of patients with coronary calcification. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Calcification of Coronary Artery
What is being tested?
Coronary atherectomy system of Shanghai MicroPort Rhythm and Rotablator Rotational Atherectomy System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
239 participants
Where
1 siteChina
Study dates
1 Jul 2022to 10 Aug 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Clinical Inclusion Criteria:

CI1. Age between 18 and 80.

CI2. Subjects who are going to accept percutaneous coronary intervention (PCI) and drug-eluting stent implantation.

CI3. Asymptomatic evidence of ischemia, stable or unstable angina pectoris, or old myocardial infarction.

CI4. Acceptable candidates for coronary artery bypass grafting (CABG).

CI5. The left ventricular ejection fraction (LVEF) is equal to or greater than 30% measured by echocardiography or left ventricle contrast examination within 30 days before inclusion.

CI6. Subjects who are able to understand the purpose of the trial, participate voluntarily or by proxy and indicate by signing the informed consent form that they recognize the risks and benefits described in the informed consent document and are willing to undergo clinical follow-up.

Angiography Inclusion Criteria:

AI1. There is only one target lesion that needs to be treated.

AI2. The target vessel must be a native coronary artery with reference diameter >= 2.5mm and <= 4.0 mm.

AI3. The target vessel must be with a stenosis of >= 70% and < 100%Target lesion angiographic stenosis, or of >=50% and <70% with local ischemic symptoms.

AI4. Target lesion length ≤ 40 mm .

AI5. The target lesion must have evidence of severe calcium deposit, or moderate calcification which cannot be fully expanded by PTCA balloon catheter at the lesion site based on the protocol criterion, .

Clinical Exclusion Criteria:

CE1. Acute myocardial infarction within 30 days prior to baseline procedure.

CE2. NYHA or Killip class III or IV heart failure.

CE3. Severe cardiac insufficiency with reduced ejection fraction (left ventricular ejection fraction < 30%).

CE4. Intracardiac thrombus within 30 days before inclusion.

CE5. Subjects who have received organ transplantation or is waiting for organ transplantation.

CE6. Subjects who are receiving chemotherapy or scheduled to receive chemotherapy 30 days before or after baseline surgery.

CE7. Subjects who are receiving chronic (≥ 72 hours) anticoagulant therapy (e.g. heparin, warfarin, coumarin) for indications other than acute coronary syndrome.

CE8. Participants' platelet < 50 × 10^9 / L or > 700 × 10^9 / L, and / or hemoglobin < 70g / L.

CE9. Subjects with confirmed or suspected liver diseases, including active hepatitis, or abnormal laboratory results are not suitable for the study.

CE10. Subjects diagnosed with chronic renal failure or has a serum creatinine level >2.5 mg/dl (or 221 µmol / L).

CE11. Subjects who have clear bleeding tendency, contraindications of antiplatelet preparation and anticoagulant treatment, and are unable to receive antithrombotic treatment.

CE12. History of cerebrovascular accident (CVA), transient ischemic attack (TIA), active peptic ulcer disease, gastrointestinal (GI) bleeding, transient ischemic attack (TIA), or permanent neurological defects that may lead to non-compliance with the test protocol in the past 6 months.

CE13. Target vessels (including collateral vessels) received any stent implantation within 12 months before baseline surgery.

CE14. Non target vessels were treated with any type of PCI within 24 hours before baseline surgery.

CE15. PCI or CABG is planned within 2 months after baseline procedure.

CE16. History of coronary endovascular brachytherapy at any time.

CE17. Known hypersensitivity to any drugs required by the stent or protocol (such as rapamycin or structure related compounds, fluoropolymers, aspirin or tigrelol, contrast medium, acrylic acid, stainless steel, chromium, nickel, iron, tungsten).

CE18. Subjects who have other serious medical diseases (such as cancer, congestive heart failure), which may reduce life expectancy to less than 12 months or it is expected to be difficult to complete 12-months follow-up.

CE19. Subjects who currently abuse drugs, such as heroin, alcohol, etc.

CE20. Subjects who plan to undergo surgery that may lead to non-compliance with the protocol or confusion in data interpretation.

CE21. Currently enrolled in any other clinical trial (does not reach its primary endpoint), or intended to participate in any other clinical trial within 12 months after baseline procedure.

CE22. Females subjects who are pregnant,breast feeding or planning to become pregnant within the study period.

CE23. Untrolled diabetes.

CE24. Inability to understand the study or a history of non-compliance with medical advice.

Angiographic Exclusion Criteria:

AE1. Target lesions that meet the following criteria:

  • Ostial lesions (within 5mm of ostium);
  • Target lesions involve bifurcation lesions, and branch vessels need to be implanted with stents;
  • Angular lesions (> 45 °)
  • Located in a native vessel distal to anastomosis with a saphenous vein graft or LIMA/RIMA bypass;
  • Thrombosis in the target vessel;
  • Target lesion dissection;
  • In-stent restenosis;
  • Chronic total occlusion lesions that cannot be passed through by atherectomy guidewire.

AE2. Unprotected left main coronary artery disease (> 50% diameter stenosis).

AE3. Protected left main coronary artery disease (> 50% diameter stenosis at LMCA and left coronary artery receive bypass grafting), and the target lesion is located in LAD or LCX.

AE4. Other clinical significant lesions in target vessels may require intervention within 2 months after baseline surgery.

AE5. The target vessel (including collateral) near the target lesion or within 10 mm (visually) from the distal end of the target lesion has received stent implantation at any time before baseline surgery.

AE6. Especially tortuous target vessels. AE7. Non-target lesion failed to be treated before the treatment of target lesion.

Trial locations and contacts

1 site in 1 country.

China1 site
  • The Second Affiliated Hospital Zhejiang University School of Medicine

    Hangzhou, Zhejiang, 310009

Other trials in China

About this study

Official title: A Prospective, Multicenter Clinical Trial of Coronary Atherectomy System in Patients With Calcified Coronary Artery Lesion

This is a prospective and multicenter clinical investigation aiming to evaluate the safety and effectiveness of coronary atherectomy system for the treatment of patients with coronary calcification.

Read the detailed description

This study is divided into two phases. The first phase is the pilot study stage, which is a prospective single group observational test (FIM stage). The second phase is the pivotal study phase, which is a prospective, multicenter, randomized controlled and non inferiority test (RCT phase). It is carried out in about 25 hospitals in China.

  1. Pilot study phase (FIM phase): It is a prospective, multicenter and single-arm observational test. It is expected to recruit 15 subjects in 3 to 5 research centers in China. The primary endpoint is procedural success rate.
  2. Pivotal study phase (RCT phase): It is a prospective, multicenter, randomized controlled and non inferiority trial. 224 subjects are expected to be recruited in 25 research centers in China and randomly divided into two groups according to the ratio of test group: control group = 1:1. The primary endpoint of the RCT phase is the rate of no major adverse cardiovascular events (MACE) at 30 days after baseline.
  3. All subjects with coronary calcified lesions participating in this clinical study must have a calcified lesion length of no more than 40 mm and located in an coronary artery with a diameter of ≥ 2.50 mm but ≤ 4.00 mm.
  4. All subjects receive clinical follow-up during hospitalization and 30 days, 6 months and 12 months after surgery.
  5. Successful enrollment: The atherectomy guidewires pass through the target lesion successfully (through the true lumen), and there are no vascular perforation, dissection, thrombosis and other complications.
Being tested
Coronary atherectomy system of Shanghai MicroPort Rhythm, Rotablator Rotational Atherectomy System
Keywords
calcification, coronary artery
Medical subject headings
Calcinosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Coronary atherectomy system of Shanghai MicroPort RhythmDevice

    Also called Stenting will be applied in both arms

    Coronary Atherectomy System utilizes a diamond-coated eccentric crown to expand the lumen diameter via centrifugal forces while rotating over an atherectomy guide wire.

  • Rotablator Rotational Atherectomy SystemDevice

    Also called Stenting will be applied in both arms

    The Rotablator Rotational Atherectomy System is comprised of a Rotablator RotaGlide, a Rotablator RotaLink Plus/RotaWire/Console

Study groups in NCT05447585
Study groupRoleWhat they receive
Coronary Atherectomy SystemExperimentalSubjects in experimental arm will be treated with the Coronary Atherectomy System manufactured by Shanghai Microport Rhythm Co. Ltd.
Receives: Device: Coronary atherectomy system of Shanghai MicroPort Rhythm
Rotablator Rotational Atherectomy SystemActive comparatorSubjects in control arm will be treated with Rotablator Rotational Atherectomy System manufactured by Boston Scientific Corporation
Receives: Device: Rotablator Rotational Atherectomy System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. FIM phase: Clinical success

    Clinical success is defined as successful stent delivery with a residual stenosis of <50% and TIMI flow III without adverse events during procedure the occurrence of an in-hospital MACE (up to 7 days after surgery).

    Measured: During hospitalization (up to 7 days after baseline procedure).

  2. RCT phase: 30-Day Freedom From Major Adverse Cardiac Events (MACE)

    MACE is composed of cardiac death, myocardial infarction and target vessel revascularization.

    Measured: 30 days after baseline procedure.

Secondary outcomes (3)
  1. Device success

    Device success is defined as successful stent delivery after atherectomy and without periprocedural complications

    Measured: Baseline procedure

  2. Procedural success

    Procedural success was defined as successful stent delivery with <50% residual stenosis and TIMI flow III and without periprocedural complications

    Measured: Baseline procedure

  3. Procedure-related complications

    Procedure-related complications are defined as severe dissection (Type D to F), perforation, stent upload and in-stent thrombosis.

    Measured: Baseline procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Jul 2022
  2. Study start1 Jul 2022
  3. Primary completion10 Aug 2023
  4. Study completion10 Aug 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
239 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05447585
Sponsor's protocol ID
AMD-D-001
Status last verified
Aug 2026
First submitted
16 Jun 2022
Last updated
10 Aug 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Li C, Wang M, Jiang J, Ma X, Yu H, Dong P, Chen X, Wang L, Hong L, Xie P, Yang Q, Ma G, Zhong Y, Lin B, Cao R, Wu T, Shen J, Yue B, Wang J; CORECT Investigators. Safety and Efficacy of a Novel Rotational Atherectomy System in Coronary Calcifications: The CORECT Trial. JACC Asia. 2026 Jul;6(7):1135-1145. doi: 10.1016/j.jacasi.2026.04.035.

    PubMed 42412697

Questions about this trial

What is this clinical trial studying?

A study testing Coronary atherectomy system of Shanghai MicroPort Rhythm and Rotablator Rotational Atherectomy System in people with Calcification of Coronary Artery, run by Shanghai MicroPort Rhythm MedTech Co., Ltd. at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

FIM phase: Clinical success (time frame: During hospitalization (up to 7 days after baseline procedure).). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05447585, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Aug 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in