Coronary Calcified DiseaseNCT05406869
Clinical Trials of Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater
A study testing Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater in people with Coronary Calcified Disease, run by Lepu Medical Technology (Beijing) Co., Ltd. at 14 sites in China.
Trial summary
The prospective, multicenter, single- arm study is designed to verify the safety and efficacy of pulsed sonic balloon dilatation catheter and pulsed sonic generater in the treatment of coronary calcification lesions. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Coronary Calcified Disease
- What is being tested?
- Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 170 participants
- Where
- 14 sitesChina
- Study dates
- 6 May 2022to 7 Jan 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- 18≤age≤80 years old, males or females;
- Life expectancy ≥ 6 months;
- Patients with evidence of asymptomatic myocardial ischemia, stability or instability; with angina, or obsolete heart infarction for interventional therapy;
- The target lesion is primary, in situ coronary artery lesion;
- The target vessel reference diameter is 1.5-4.0mm, and the lesion length is ≤40mm (visual inspection);
- Target lesion is with a visually estimated stenosis of ≥70%(or≥50% with evidence of myocardial ischemia) ;
Show all 10Show fewer
- Highly calcified lesions;
- Only one target lesion requiring sonic balloon treatment is allowed;
- The number of non-target lesions requiring interventional treatment is no more than 2, and the target lesions should be treated after the non-target lesions are successfully treated;
- Patients who can understand the purpose of the trial, voluntarily participate and sign the informed consent form, and can accept required clinical follow-up.
Who cannot join
- New York Heart Association (NYHA) class III or IV;
- Severe liver and kidney damage, transaminase more than 3 times the upper limit of normal, creatinine > 2.5mg/dL (221μmol/L) or chronic renal failure requiring long-term dialysis;
- Stroke occurred within 6 months of joining the group, excluding transient is chemic attack (TIA) and cavity infarction;
- Have a history of active peptic ulcer or upper gastrointestinal (GI) bleeding within 6 months of joining the group;
- Platelet count <80×10⁹/L;
- Subject refuses or is not suitable for CABG surgery;
Show all 18Show fewer
- The target lesion is planned to undergo coronary atherectomy, laser, double guide wire balloon, mastoid balloon, cutting balloon or thrombus aspiration;
- Dissection of the target vessel after preoperative angiography or guide wire pass through;
- The stent has been implanted within 10mm of the proximal or distal end of the target lesion, and there is a definite or possible thrombus in the target vessel;
- The target lesion is located or involved within 5mm of the opening of LAD, LCX and RCA;
- Left main stem disease or bridge vascular disease;
- Angiography shows that the blood vessel path is tortuous, and the test device is difficult to reach the target position or difficult to recover;
- Patients with implanted pacemakers or cardiac rhythm devices;
- Evidence of aneurysm within 10 mm of the target lesion;
- Patients who are known to be allergic to heparin, contrast agents, aspirin, clopidogrel, and anesthetics;
- The subject is currently participating in another drug or device clinical study that has not yet completed;
- Pregnant or nursing subjects;
- Other patients should be excluded based on the assessment of the investigators;
Trial locations and contacts
14 sites in 1 country.
14 sites in 1 country
China14 sites
Beijing Anzhen Hospital, Capital Medical Univesity
Beijing, Beijing Municipality
Beijing Chao-yang Hospital , Capital Medical University
Beijing, Beijing Municipality
Peking University First Hospital
Beijing, Beijing Municipality
Peking University People's Hospital
Beijing, Beijing Municipality
Peking University Third Hospital
Beijing, Beijing Municipality
The Southwest Hospital of Amu
Chongqing
The First Affiliated Hospital, Sun Yat-sen University
Guangzhou
The Second Xiangya Hospital of Central South University
Hunan
Xiangya Hospital Central South University
Hunan
LinFen Central Hospital
Shanxi
The First Affiliated Hospital of Soochow University
Suzhou
Union Hospital Tongji Medical College Huazhong University of Science and Technology
Wuhan
Xuzhou central hospital
Xuzhou
Sir Run Run Shaw Hospital ZheJiang University School of Medicine
Zhejiang
About this study
Official title: A Prospective, Multicenter, Single-arm Study to Evaluate the Safety and Efficacy of Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater in the Treatment of Coronary Calcified Lesions
The prospective, multicenter, single- arm study is designed to verify the safety and efficacy of pulsed sonic balloon dilatation catheter and pulsed sonic generater in the treatment of coronary calcification lesions.
Read the detailed description
The study will include a total of 170 patients with calcified coronary lesions who will be treated with pulsed sonic balloon dilatation catheter and pulsed sonic generater. Optical coherence tomography (OCT) imaging subgroups of 30 patients were designed in 1-2 centers to further accurately assess the treatment effect of calcified lesions.
- Conditions
- Coronary Calcified Disease
- Being tested
- Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater
- Keywords
- Coronary Sonic Balloon
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic GeneraterDevice
Deliver Pulsed Sonic Balloon Dilatation Catheter to the target vessel prior to placing a coronary stent or others
| Study group | Role | What they receive |
|---|---|---|
| pulsed sonic balloon dilatation catheter and pulsed sonic generater | Experimental | All subjects will receive treatment from the pulsed sonic balloon dilatation catheter Receives: Device: Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater |
What is being measured
The primary outcome is the main question the study is designed to answer.
Procedural success rate
Procedural success was defined as residual stenosis ≤30% after successful stent delivery without the occurrence of in-hospital adverse cardiac events (include cardiac death, target vessel-related myocardial infarction (TV-MI) and target lesion revascularizition)
Measured: immediate post-procedure
Secondary outcomes (8)
Device success rate
Device success was defined as residual stenosis ≤50% with the successful delivery, deployment and withdrawal of pulsed acoustic wave balloon dilatation catheter to the target lesion.
Measured: immediate post-procedure
Lumen diameter obtained
Defined as the change of minimal luminal diameter[MLD] between the Follow-up points and baseline.
Measured: immediate post sonic balloon treatment, immediate post-procedure
Percentage of diameter stenosis
Defined as (1-minimal luminal diameter[MLD]/reference vessel diameter[RVD])*100%
Measured: immediate post sonic balloon treatment, immediate post-procedure
Target Lesion Failure (TLF)
Target lesion failure is a composite endpoint of cardiac death, target vessel related myocardial infarction (TV-MI) and the ischemia-driven target lesion revascularization.
Measured: before discharge or 7 days post-procedure, 30 days post-procedure
Patient-related cardiovascular clinical composite endpoint (POCE)
Including all-cause death, all MI, or any revascularization
Measured: before discharge or 7 days post-procedure, 30 days post-procedure
Confirmed and probable thrombotic events
Including Acute thrombosis, Early thrombosis, Late thrombosis, Very late thrombosis.
Measured: before discharge or 7 days post-procedure, 30 days post-procedure
The stability of the pulse sonic energy generator
Including excellent, good and poor levels
Measured: immediate post-procedure
Ease of use of pulsed acoustic energy generators
Including excellent, good and poor levels
Measured: immediate post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted7 Jun 2022
- Study start6 May 2022
- Primary completion7 Oct 2022 (estimated)
- Study completion7 Jan 2023 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary Calcified DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 170 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Lepu Medical Technology (Beijing) Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Yida Tang, Study chair, Peking University Third Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05406869
- Sponsor's protocol ID
- LP-Pulsed Sonic Balloon-2022
- Status last verified
- May 2022
- First submitted
- 27 May 2022
- Last updated
- 7 Jun 2022
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 7 Jun 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective, Multicenter, Single-arm Study to Evaluate the Safety and Efficacy of Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater in the Treatment of Coronary Calcified Lesions
- ClinicalTrials.gov ID
- NCT05406869
- Acronym / sponsor ID
- LP-Pulsed Sonic Balloon-2022
- Conditions
- Coronary Calcified Disease
- Keywords
- Coronary Sonic Balloon
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 170 participants (estimated)
- Lead sponsor
- Lepu Medical Technology (Beijing) Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- 6 May 2022 (actual)
- Primary completion
- 7 Oct 2022 (estimated)
- Study completion
- 7 Jan 2023 (estimated)
- First posted
- 7 Jun 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The prospective, multicenter, single- arm study is designed to verify the safety and efficacy of pulsed sonic balloon dilatation catheter and pulsed sonic generater in the treatment of coronary calcification lesions.
Detailed description
The study will include a total of 170 patients with calcified coronary lesions who will be treated with pulsed sonic balloon dilatation catheter and pulsed sonic generater. Optical coherence tomography (OCT) imaging subgroups of 30 patients were designed in 1-2 centers to further accurately assess the treatment effect of calcified lesions.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| pulsed sonic balloon dilatation catheter and pulsed sonic generater | Experimental | Device: Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic GeneraterAll subjects will receive treatment from the pulsed sonic balloon dilatation catheter |
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (10 listed)
- 18≤age≤80 years old, males or females;
- Life expectancy ≥ 6 months;
- Patients with evidence of asymptomatic myocardial ischemia, stability or instability; with angina, or obsolete heart infarction for interventional therapy;
- The target lesion is primary, in situ coronary artery lesion;
- The target vessel reference diameter is 1.5-4.0mm, and the lesion length is ≤40mm (visual inspection);
Key exclusion criteria (18 listed)
- New York Heart Association (NYHA) class III or IV;
- Severe liver and kidney damage, transaminase more than 3 times the upper limit of normal, creatinine > 2.5mg/dL (221μmol/L) or chronic renal failure requiring long-term dialysis;
- Stroke occurred within 6 months of joining the group, excluding transient is chemic attack (TIA) and cavity infarction;
- Have a history of active peptic ulcer or upper gastrointestinal (GI) bleeding within 6 months of joining the group;
- Platelet count <80×10⁹/L;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic GeneraterDeliver Pulsed Sonic Balloon Dilatation Catheter to the target vessel prior to placing a coronary stent or others | Device | pulsed sonic balloon dilatation catheter and pulsed sonic generater |
Primary outcome
Procedural success rate
Time frame: immediate post-procedure
Procedural success was defined as residual stenosis ≤30% after successful stent delivery without the occurrence of in-hospital adverse cardiac events (include cardiac death, target vessel-related myocardial infarction (TV-MI) and target lesion revascularizition)
8 secondary outcomes
Device success rate
Time frame: immediate post-procedure
Lumen diameter obtained
Time frame: immediate post sonic balloon treatment, immediate post-procedure
Percentage of diameter stenosis
Time frame: immediate post sonic balloon treatment, immediate post-procedure
Target Lesion Failure (TLF)
Time frame: before discharge or 7 days post-procedure, 30 days post-procedure
Patient-related cardiovascular clinical composite endpoint (POCE)
Time frame: before discharge or 7 days post-procedure, 30 days post-procedure
Confirmed and probable thrombotic events
Time frame: before discharge or 7 days post-procedure, 30 days post-procedure
The stability of the pulse sonic energy generator
Time frame: immediate post-procedure
Ease of use of pulsed acoustic energy generators
Time frame: immediate post-procedure
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 7 Jun 2022.
Related trials for Coronary Calcified Disease
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Active, not recruitingObservational study
Intravascular Lithotripsy in High Risk Calcified Iliac Anatomy for Transfemoral TAVR
Iliac Disease, Aortic Valve Stenosis
Not yet recruitingPhase 2
REducing Systemic Inflammation With LOw-dose Colchicine to ImproVE Cardiovascular Calcification in Chronic Kidney Disease: A Pilot Randomized Open-Label Trial
Chronic Kidney Disease Mineral and Bone Disorder, Cognitive Function
Active, not recruiting
Target Value Study to Evaluate the Safety and Efficacy of the Taurus NXT® Transcatheter Aortic Valve System for the Treatment of Severe Calcific Aortic Stenosis
Aortic Stenosis
Not yet recruitingObservational study
Relationship Between Insulin Dose and Complications in Type 1 Diabetes
Diabetes Mellitus, Type 1 Diabetes, Cardiovascular Diseases (CVD)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Yida Tang study chair
Peking University Third Hospital
14 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Pulsed Sonic Balloon Dilatation Catheter and Pulsed Sonic Generater in people with Coronary Calcified Disease, run by Lepu Medical Technology (Beijing) Co., Ltd. at 14 sites in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 10 inclusion and 18 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 7 Jun 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 14 sites in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Procedural success rate (time frame: immediate post-procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Jun 2022.