AzTrials
AzTrials

LipodystrophyNCT05402982

Intraoperative Fluid Management of Liposuction , Cardiometry Versus Rohrich Formula

A study testing Electrical Cardiometry (EC) ICON and Rohrich formula in people with Lipodystrophy, run by Ahmed Abdel Wahed Ali at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The aim of the study is to compare the hemodynamic parameters of fluid resuscitation using Rohrich formula to cardiometry guided stroke volume variation in patients undergoing large volume liposuction surgery . Read more about this study

Who is it for?
Ages 21 to 60 yearsHealthy volunteers can take part
Conditions the study is for
Lipodystrophy
What is being tested?
Electrical Cardiometry (EC) ICON and Rohrich formula
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
1 siteEgypt
Study dates
25 Jun 2022to 1 Jul 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 to 60 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Male and female patients aged between 21 to 60 years.
  • American Society of Anesthesiologists (ASA) Ӏ\& ӀӀ.
  • Large volume liposuction.

Who cannot join

  • Any bleeding\& coagulation disorders.
  • Patients on regular anticoagulant or antiplatelet drugs.
  • History of previous surgery in treated areas.
  • Significant cardiopulmonary, hepatic or renal disease.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Tanta University

    Tanta, Gharbia Governorate

Other trials in Egypt

About this study

Official title: Intraoperative Fluid Management of Large Volume Liposuction Surgery , Cardiometry Guided Stroke Volume Variation Versus Rohrich Formula

The aim of the study is to compare the hemodynamic parameters of fluid resuscitation using Rohrich formula to cardiometry guided stroke volume variation in patients undergoing large volume liposuction surgery .

Read the detailed description

The study will done on 50 patients divided equally into two groups. Group A Fluid administration in the form of lactated ringer will be managed by Rohrich formula and the intraoperative fluid ratio (subcutaneous infiltration fluid plus intravenous fluid divided by total aspirate volume) will be 1.2. Rohrich formula represents fluid maintenance,deficit and replacement fluid ( 0.25 ml crystalloid given for each 1 ml above 4 litre of lipoaspirate).

Group B Patients will receive fluid maintenance of lactated ringer 2 ml/kg/h, cardiometry guided stroke volume variation will be measured before and after induction then every 30 min ,it ranges between 5-15%, fluid bolus of lactated ringer 4 ml /kg over 15 min will be administered if stroke volume variation ˃ 15% .

Electrical cardiometry will be connected to the patient before induction,the skin will be clean and dry before placing the electrodes. Four electrodes will be applied, first one is at the upper part of the anterior aspect of the neck, second one is 5 cm below the first electrode at lower part of the neck, third one at the lower left thorax in line with xiphoid process at the level of anterior axillary line and the fourth one is 5 cm below the third electrode at the level of anterior axillary line.Electrical cardiometry will be connected to the sensor cable and the patient data will be applied as (gender - age - height - weight - blood pressure -heart rate - hemoglobin and oxygen saturation).

Surgical Technique The wetting solution will be lactated ringer with epinephrine 1mg on 1 litre so concentration is 1:1,000,000.10 ml lidocaine 2% will be added.Subcutaneous infiltration of the wetting solution will facillate dissection and removal of fat ,the technique that will be used is traditional liposuction , suction assisted liposuction with super wet technique ( the amount of infiltration solution is equal to the amount of fat aspirate).

The liposuction cannula is a multihole blunt tip cannula with a diameter of 3 to 6 mm, 4-6 mm for deep liposuction,2-4 mm for superficial liposuction and a length ranging between 10 to 30 cm. The surgeon will inject the wetting solution to the target area until it becomes tense then infiltrates the other side waiting 10 to 15 min after infiltration to begin suction .The aspirate will be collected in suction container, fat will separate from solution after approximately 1-2 h by gravity into upper yellowish part includes fat called supernatant and lower part includes blood tinged fluid called infranatant.

Measurements

  • Noninvasive blood pressure ,oxygen saturation, Heart rate before induction, 5 min and 15 min after induction then every 30 min.
  • Urine output, baseline and every hour.
  • Venous blood sample for measurement of hemoglobin and hematocrit level after aspiration of 4 litre of fat and for every litre after.
  • Measurement of blood volume in aspirate by taking a sample from infranatant part after its separation from fat for hemoglobin level calculation and by equation of multiplying this hemoglobin concentration to infranatant volume divided by preoperative hemoglobin concentration, the investigators can measure blood volume in aspirate .
  • Amount of intravenous and infiltration fluids.
  • Amount of fat and total aspirate.
  • Stroke volume variation before and after induction then every 30 min.
Conditions
Lipodystrophy
Being tested
Electrical Cardiometry (EC) ICON, Rohrich formula
Keywords
Lipodystrophy
Medical subject headings
Lipodystrophy

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electrical Cardiometry (EC) ICONDevice

    Electrical Cardiometry (EC) ICON (Osypka Medical, Berlin, Germany) is an FDA approved device used for non-invasive measurement of some hemodynamic parameters as cardiac output,cardiac index, stroke volume,stroke volume variation, systemic vascular resistance, thoracic fluid content, ICON (index of contractility), variation of ICON,corrected flow time and systolic time ratio.The set data of EC are the height, weight,hemoglobin, Oxygen saturation(SPO2),age, gender ,blood pressure and heart rate(HR) of the patient

  • Rohrich formulaOther

    Rohrich formula and the intraoperative fluid ratio (subcutaneous infiltration fluid plus intravenous fluid divided by total aspirate volume) will be 1.2

Study groups in NCT05402982
Study groupRoleWhat they receive
GROUP AOtherFluid administration in the form of lactated ringer will be managed by Rohrich formula and the intraoperative fluid ratio (subcutaneous infiltration fluid plus intravenous fluid divided by total aspirate volume) will be 1.2(10). Rohrich formula represents fluid maintinance,deficit and replacement fluid ( 0.25 ml crystalloid given for each 1 ml above 4 litre of lipoaspirate).
Receives: Other: Rohrich formula
GROUP BOtherPatients will receive fluid maintenance of lactated ringer 2 ml/kg/h, cardiometry guided SVV will be measured before and after induction then every 30 min ,it ranges between 5-15%, fluid bolus of lactated ringer 4 ml /kg over 15 min will be administered if SVV ˃ 15% .
Receives: Device: Electrical Cardiometry (EC) ICON

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mean arterial blood pressure

    Mean arterial blood pressure at 4 litre aspiration of fat and at every litre aspirated after.

    Measured: 1 year

Secondary outcomes (2)
  1. blood loss

    estimation of blood loss by venous sample and suction sample

    Measured: 1 year

  2. urine output

    detection of tissue perfusion by urine output every hour

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Jun 2022
  2. Study start25 Jun 2022
  3. Primary completion10 Jun 2023
  4. Study completion1 Jul 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
The study will done on 50 patients divided equally into two groups. Group A Fluid administration in the form of lactated ringer will be managed by Rohrich formula and the intraoperative fluid ratio (subcutaneous infiltration fluid plus intravenous fluid divided by total aspirate volume) will be 1.2(10). Rohrich formula represents fluid maintinance,deficit and replacement fluid ( 0.25 ml crystalloid given for each 1 ml above 4 litre of lipoaspirate). Group B Patients will receive fluid maintenance of lactated ringer 2 ml/kg/h, cardiometry guided SVV will be measured before and after induction then every 30 min ,it ranges between 5-15%, fluid bolus of lactated ringer 4 ml /kg over 15 min will be administered if SVV ˃ 15% .
Masking
None (open label)
Enrolment
50 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05402982
Sponsor's protocol ID
fluid status of liposuction
Status last verified
Nov 2023
First submitted
20 May 2022
Last updated
29 Nov 2023
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Rajput RS, Das S, Chauhan S, Bisoi A, Vasdev S. Comparison of cardiac output measurement by noninvasive method with electrical cardiometry and invasive method with thermodilution technique in patients undergoing coronary artery bypass grafting. World Journal of Cardiovascular Surgery. 2014;2014

  • Rohrich RJ, Leedy JE, Swamy R, Brown SA, Coleman J. Fluid resuscitation in liposuction: a retrospective review of 89 consecutive patients. Plast Reconstr Surg. 2006 Feb;117(2):431-5. doi: 10.1097/01.prs.0000201477.30002.ce.

    PubMed 16462322
  • Kadafi KT, Latief A, Pudjiadi AH. Determining pediatric fluid responsiveness by stroke volume variation analysis using ICON(R) electrical cardiometry and ultrasonic cardiac output monitor: A cross-sectional study. Int J Crit Illn Inj Sci. 2020 Jul-Sep;10(3):123-128. doi: 10.4103/IJCIIS.IJCIIS_87_18. Epub 2020 Sep 22.

    PubMed 33409126

Questions about this trial

What is this clinical trial studying?

A study testing Electrical Cardiometry (EC) ICON and Rohrich formula in people with Lipodystrophy, run by Ahmed Abdel Wahed Ali at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mean arterial blood pressure (time frame: 1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05402982, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Nov 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in