AzTrials
AzTrials

Vertical Alveolar Bone LossNCT05290376

Clinical Evaluation of RTX Locator Attachments for Implant-supported Mandibular Complete Overdenture

A study testing surgical placement of long dental implants and overdenture supported by RTX attachment system in people with Vertical Alveolar Bone Loss, run by Mansoura University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study was conducted to clinically and radiographically evaluate locator RTx attachments for two implant-supported mandibular overdenture using two loading protocols Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
Conditions the study is for
Vertical Alveolar Bone Loss
What is being tested?
surgical placement of long dental implants and overdenture supported by RTX attachment system
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteEgypt
Study dates
15 Jan 2020to 20 Sep 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • adequate bone quantity [class III -V according to Cawood and Howell in the interforaminal area of the mandible to receive 2 implants (4×13 mm)
  • adequate restorative space [12-15 mm from the mucosa of the mandibular ridge to the occlusal plane, Class I according to Ahuja and Cagna for RTX supported implant overdenture.

Who cannot join

  • systemic diseases that contraindicate implant placement
  • bone metabolic diseases as diabetes mellitus
  • irradiation of the head and neck region
  • chemotherapy within the past 3 years
  • smoking habits.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Christine Ibrahim

    Al Mansurah, P.O.Box:35516

Other trials in Egypt

About this study

Official title: Clinical Evaluation of RTX Locator Attachments for Implant-supported Mandibular Complete Overdenture Using Two Loading Protocols

This study was conducted to clinically and radiographically evaluate locator RTx attachments for two implant-supported mandibular overdenture using two loading protocols

Read the detailed description

Thirty edentulous patients received two implants in the interformaninal region in the canine area . According to the loading protocol used for attaching mandibular overdenture, patients were randomly assigned into two equal groups. Group I (control): patients who would be delivered mandibular implant overdenture retained by two RTx locator attachments using conventional loading protocol. Group II (study): patients who would be delivered mandibular overdenture retained by two RTx locator attachments using early loading protocol. Peri-implant tissue health [Plaque (PL) and (GI) gingival scores, pocket depth (PD), and crestal bone loss (CBL)] were evaluated immediately after denture insertion (T0), 6 (T6), and 12 (T12) months after insertion.

Being tested
surgical placement of long dental implants, overdenture supported by RTX attachment system

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • surgical placement of long dental implantsProcedure or surgery

    Two interforaminal implants were placed in the canine region

  • overdenture supported by RTX attachment systemDevice

    Control group: Implants were loaded after three months by RTX supported overdenture study group: Implants were loaded after four weeks by RTX supported overdenture

Study groups in NCT05290376
Study groupRoleWhat they receive
Control groupActive comparatorGroup I (control): patients who would be delivered mandibular implant overdenture retained by two RTx locator attachments using conventional loading protocol
Receives: Procedure: surgical placement of long dental implants; Device: overdenture supported by RTX attachment system
Study groupActive comparatorGroup II (study): patients who would be delivered mandibular overdenture retained by two RTx locator attachments using early loading protocol.
Receives: Procedure: surgical placement of long dental implants; Device: overdenture supported by RTX attachment system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Marginal bone loss

    evaluations of crestal bone loss in mm around implants by digital periapical radiography

    Measured: one year

  2. plaque score

    evaluation of plaque accumulation around RTX attachments using scores.score 0; absence plaque , score 1; plaque only detected by a probe passing through the smooth marginal surface of the implant, score 2; plaque can be recognized by naked eye, and score 3; plenty of soft matter.

    Measured: one year

  3. gingival index

    evaluation of gingival bleeding around RTX attachments using scores.0; no bleeding when a periodontal probe is passed along the mucosal margin, 1;isolated bleeding spots visible, 2; blood forms a confluent red line on the mucosal margin, 3;heavy or profuse bleeding.

    Measured: one year

  4. pocket depth

    evaluation of pocket depth in mm around RTX attachments

    Measured: one year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Mar 2022
  2. Study start15 Jan 2020
  3. Primary completion15 Dec 2020
  4. Study completion20 Sep 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Patients were randomly assigned into two equal groups. Group I (control): patients who would be delivered mandibular implant overdenture retained by two RTX locator attachments using conventional loading protocol. Group II (study): patients who would be delivered mandibular overdenture retained by two RTx locator attachments using early loading protocol.
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05290376
Sponsor's protocol ID
A03110220
Status last verified
Dec 2021
First submitted
15 Dec 2021
Last updated
22 Mar 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing surgical placement of long dental implants and overdenture supported by RTX attachment system in people with Vertical Alveolar Bone Loss, run by Mansoura University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Mar 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Marginal bone loss (time frame: one year). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Mar 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in