GlaucomaNCT05235321

Automated Applanation Tonometry

A study testing Standard GAT, Fixed force GAT and Upright applanating prototype in people with Glaucoma and Glaucoma, Suspect, run by Duke University at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Glaucoma, Glaucoma, Suspect
What is being tested?
Standard GAT, Fixed force GAT and Upright applanating prototype
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
118 participants
Where
1 siteUnited States
Study dates
21 Nov 2022to 31 May 2024
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Presenting for a routine eye exam
  • ≥ 18 years of age
  • Able and willing to give consent

Who cannot join

  • History of corneal scarring
  • Active infection of the eye

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Duke Eye Center

    Durham, North Carolina, 27710

Other trials in United States

About this study

Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. The purpose of this study is to develop an automated and objective method for performing applanation tonometry using standard ophthalmic equipment as well as using 2 portable prototypes.

Read the detailed description

This is a prospective study. Patients presenting for their scheduled eye appointments will be recruited by verbal communication. Following informed consent, intraocular pressure (IOP) measurements will be made by the following 3 upright methods and 1 supine measurements:

  1. Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice. The eye is given topical fluorescein/anesthetic, the GAT prism contacts the eye while the observer looks through the slit lamp machine ocular using blue light illumination to visual the applanation mires. The GAT dial is adjusted until mire alignment is achieved and the IOP measurement is read off the GAT dial.
  2. Fixed force GAT: From the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a complementary metal oxide semiconductor (C-MOS) camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. A similar method using an iPod touch camera has been previously published by this PI.
  3. Upright applanating prototype: With this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. The order of the above 3 measurements will be randomized. The 4th measurement will be made with the patient in the supine position. Here, the subject will be reclined in our standard clinical exam chair until the iris plane is parallel to the ground.
  4. Supine applanating prototype: With this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter. A similar method using an iPhone 6 camera has been previously published by this PI. The clear cylinder in this study is the same as that used in this prior study.
Being tested
Standard GAT, Fixed force GAT, Upright applanating prototype, Supine Applanating Prototype
Medical subject headings
Glaucoma, Ocular Hypertension

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Standard GATDevice

    Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice

  • Fixed force GATDevice

    An investigational device similar to standard GAT

  • Upright applanating prototypeDevice

    An investigational device, prism used in standard and fixed-force GAT is attached to a portable device

  • Supine Applanating PrototypeDevice

    An investigational device, prism used in standard and fixed-force GAT is attached to a portable device performed in the supine position

Study groups in NCT05235321
Study groupRoleWhat they receive
Standard GATActive comparatorThis is the standard method for IOP measurement in clinical practice
Receives: Device: Standard GAT
Fixed-force GATExperimentalFrom the patient perspective, this method will feel identical to the standard GAT. The eye is given topical fluorescein/anesthetic. The GAT dial is set at 1.8 or 2.0, a C-MOS camera is connected to one of the oculars of the slit lamp machine and under blue light illumination, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance through the ocular. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter
Receives: Device: Fixed force GAT
Upright applanating prototypeExperimentalWith this prototype, an applanating prism (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is attached to a fixed-force spring that creates a force equivalent to 1.8 or 2.0 on the GAT dial. Blue LED lights on the prototype are used to create the blue illumination similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. A C-MOS camera is aligned with the GAT prism to image the applanation mires. The eye is given topical fluorescein/anesthetic. Like fixed-force GAT, the GAT prism contacts the eye while the CMOS camera makes a video of the mire appearance. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter
Receives: Device: Upright applanating prototype
Supine Applanating PrototypeExperimentalWith this method, a 5 gram clear acrylic cylinder (custom manufactured with medical grade acrylic in an ISO-13485 certified facility) is aligned with the lens of the CMOS camera and the distal tip of the cylinder is illuminated with blue light using an LED similar to the blue light used in clinical practice on the slit lamp or Perkins tonometer. The eye is given topical fluorescein/anesthetic. While the CMOS camera is recording, the 5 gram weight will rest upon the eye and circular applanation mires are recorded. The diameters of the recorded mire images are measured and the IOP is calculated based on the mire diameter
Receives: Device: Supine Applanating Prototype

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Intraocular Pressure (IOP)

    Intraocular pressure (IOP) as measured by Standard GAT, Fixed-force GAT, and Upright Applanating Prototype.

    Measured: Single study visit, approximately 20 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 Feb 2022
  2. Study start21 Nov 2022
  3. Primary completion31 May 2024
  4. Study completion31 May 2024

Why it stopped: device updates needed

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Model description
In this study, 3 eye pressure measurements will be made in the upright position (standard GAT, fixed force GAT, upright applanating prototype) and 1 in the supine position (supine applanating prototype).
Masking
None (open label)
Enrolment
118 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05235321
Sponsor's protocol ID
Pro00106111
Status last verified
Aug 2026
First submitted
2 Feb 2022
Last updated
11 Sep 2026
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: No Currently, there is no plan to share data with other researchers.

Questions about this trial

What is this clinical trial studying?

A study testing Standard GAT, Fixed force GAT and Upright applanating prototype in people with Glaucoma and Glaucoma, Suspect, run by Duke University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 11 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 11 Sep 2026). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Intraocular Pressure (IOP) (time frame: Single study visit, approximately 20 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Sep 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in