AzTrials
AzTrials

EpilepsyNCT05123469

Clinical Validation of zEEG, a Wireless EEG Recording System for Pediatric and Adult Patients With Epilepsy

An observational study of Epilepsy and EEG With Periodic Abnormalities, run by University of Texas at Austin at 1 site in United States.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to compare the standard clinical electroencephalography (EEG) device with a new portable wireless EEG device, further referred to as zEEG, made by ZETO®. Read more about this study

Who is it for?
Ages 1 year to 99 years
What is being tested?
Electroencephalography
Type of treatment
Medical device
How many people
30 participants
Where
1 siteUnited States
Study dates
Jan 2022to Mar 2023
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 year to 99 years
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: Patients diagnosed with epilepsy

Who may be able to join

  • Patients with the diagnosis of simple and multifocal seizure or generalized seizure who are at least 1 year old but 19 years old at most, whose head the zEEG headset fits, and who also produced sufficient seizure and normal activity EEG data. This age range is all-inclusive, because the actual patient selection will be based on the head-sizes that the zEEG system will fit to.

Who cannot join

  • Patients younger than 1 year and older than 19 years, pseudo seizures, patients who did not generate normal EEG data or their EEG electrode setting is in conflict with the zEEG headset will be excluded. Patients who cannot keep the zEEG headset on their head will be excluded.

Trial locations and contacts

1 site in 1 country.

Zoltan Nadasdy, Ph.D. contact

323-697-6714

zoltan@utexas.edu

United States1 site
  • Dell Children's Medical Center

    Austin, Texas, 78723

    Reggie I Louis, MS, 512-324-7000 ext. 77326, RILouis@seton.org

    Zoltan Nadasdy, Ph.D.

Other trials in United States

About this study

The purpose of this study is to compare the standard clinical electroencephalography (EEG) device with a new portable wireless EEG device, further referred to as zEEG, made by ZETO®. zEEG was designed to make EEG studies simpler, safer, more comfortable, faster, and less obstructive for the patient, also easier to set up for technicians. Wireless and battery powered, it uses the latest mobile technology. Contrary to the clinical EEG, this headset does not use any glue between the skin and the electrodes. Minor skin irritation may still occur but much less likely than from the collodion glue used in the clinical electrodes. In addition, the zEEG system does not need any gel to be applied to the skin. The zEEG electrodes are dry and disposable. They have never been used on any other head before. No additional risk is involved with setting it up. In addition to the clinically necessary EEG electrodes or intracranial electrodes for long term monitoring, we will place zEEG on the head to compare the sensitivity of the new device to the traditional device. zEEG is proven to meet the standard of clinical system and received an FDA clearance in 2018. If further clinical tests validate its technical parameters and comfort, it may replace traditional clinical EEG systems.

Read the detailed description

Research Hypothesis:

The hypothesis is that signals recorded by zEEG do not differ significantly from signals recorded by a standard clinical EEG system (clinical EEG). In this study we will use the Xltek® (Natus, Inc.) clinical-grade FDA-approved long-term video monitoring EEG system and the Nicolet ® (Natus, Inc.) clinical-grade FDA approved ambulatory EEG system. zEEG will be compared against both systems. Minor difference in signal is expected due to the non-overlapping positions of the 6 electrodes. The 1-2 cm position difference between the electrodes is expected to generate discernible difference between the two signals.

Background:

The purpose of the study is to validate the zEEG® by ZETO, Inc. (zEEG), a wearable wireless headset and data acquisition (DAQ) system on both pediatric and adult patient populations diagnosed with epilepsy. The study compares (i) the technical parameters of the two systems, (ii) the sensitivity and specificity of the zEEG against standard clinical EEG DAQ systems used for detecting abnormal epileptiform discharges, (iii) the correlation with intracranial recordings, (iv) and the discriminability of the two systems by trained neurologists in a double-blind paradigm. Since zEEG device has received a 510(k) clearance from FDA in 2018, the study does not concern with the safety of the device. The device poses no significant risk, as evaluated by the FDA, and qualifies as Class II category. The goal of the study is to evaluate the utility of a dry, easy to use, wireless system in clinical electrography by a quantitative assessment of the overall quality of the signal relative to a traditional clinical EEG system.

Design and methodology:

Spec Aim 1: Quantify and compare the signal quality between the zEEG and clinical EEG system in simultaneous recording sessions performed for diagnostic purpose in patients under clinical setting, one session per patient. Specifically, we will be testing signal overlap (amplitude, sampling frequency, alpha waves, sharp waves, focal slowing, spike and wave patterns, and sleep spindles) and spectral correlation between the two systems. We will use a multi-factorial ANOVA design, where the independent variables are arranged into 4 factors: age-group (pediatric, adult), system (zEEG, cEEG), task (1-5), and recording sites (10-20 system). The dependent variable is the spectral signal to noise ratio (SNR) computed as the spectral mean (divided by the spectral standard deviation.

Spec Aim 2: Determine the sensitivity and specificity of the two systems for epileptiform activity in simultaneous recordings. Although Spec Aim 1 will provide us an estimate of the sensitivity of zEEG relative to the clinical EEG system, it does not provide an estimate on the specificity of the parameters for electrographic events that are relevant for diagnosis. For example, if the zEEG with its high-impedance dry electrodes turns out to be a lot more sensitive to electric potential changes than the standard clinical device, that might increase its sensitivity for movement artifacts too, which would contaminate neuronal signals. Sensitivity without specificity does not mean improvement. Therefore, we will test whether the difference in sensitivity is associated with a difference in specificity as well. A dry electrode-based system will surpass the standard wet electrode clinical systems if it provides at least the same sensitivity and specificity for the representation of clinically relevant EEG events. Therefore, we will compare the separation between myogenic artifacts, teeth clenching, head movements, eye movements, and EEG between the two systems, zEEG and the clinical EEG system. In this Specific Aim, we will only compare Xltek® (Natus, Inc.) a clinical-grade FDA approved long-term monitoring EEG system with zEEG, as opposed to using two different clinical EEG systems (Nicolet® and Xltek) to ensure the homogeneity of samples (Appendix, Figure 2A). Most importantly, we will compare the separation between baseline and epileptiform activity. Instances of epileptiform activity will be identified by trained neurologists among our key co-investigators. We will compare the magnitude of amplitude- and power spectra-change from baseline EEG to movement artifacts and epileptiform activity between the two systems. Spectral density statistics will be computed between 1 and 180 Hz.

The recordings for Spec Aim 1 and Spec Aim 2 will be performed on different subjects using different clinical amplifiers as comparator systems: Nicolet® designed for ambulatory data acquisition, and an Xltek® designed for long term monitoring. Each patient will participate in the study only once.

Spec Aim 3: Testing the concordance of clinical evaluations made by 16 expert neurologists based on EEG records obtained by the two systems. We will compare the clinical conclusions made about relevant features of epileptiform activity captured in simultaneous zEEG and clinical EEG samples.

The purpose of this aim is to evaluate the clinical validity of the records made by using zEEG relative to the records made by using standard clinical EEG systems. We are testing whether the information conveyed by samples of the two different systems are concordant when evaluated by trained neurologists. This aim compares how clinically informative the two systems are, regardless of their technical parameters. Ultimately, the new EEG system is informative only if the clinical conclusions drawn from the two types of samples are concordant. Note, that this Aim does not concern which system is better. Instead, it addresses whether the zEEG is good enough to replace the clinical EEG system, given its advantage of ease of use, set up time, wearability and comfort. Nor does the Aim assume that the two systems are indistinguishable. Expert neurologists will not compare the two systems directly to each other. Instead, they will provide clinical assessments based on the samples. Those samples will be pre-selected by other expert neurologists (the investigators of this study). There will be no overlap between CO-Investigators and expert subject neurologists. The clinical assessments provided by the subject neurologists will be blindly scored by a computer program, and the PI and the author of the study will evaluate the concordance of those scores. Based on the concordance, the investigators conclude whether the two EEG systems convey the same clinical information or not. This procedure ensures the double-blind paradigm and minimizes biases.

Data Analysis:

Spec Aim 1: For the statistical evaluation we segment the data into equal blocks of 256 points (512 ms) and perform FFT (Fast Fourier Transform). We will use the sliding-window multi-taper spectral decomposition to avoid edge effects between the blocks. We will perform these analyses in each channel separately. Using multiple blocks, we will be able to compute statistics on 351 samples from 3 m recording. The spectral difference will be estimated with a confidence of 0.05 at different frequency bands and using Bonferrioni correction for the multiple comparisons.

Finally, we will compute the correlation coefficient between the zEEG and clinical EEG spectra under all 5 conditions

Spec Aim 2: Our neurologists will identify, and clip prerecorded simultaneous zEEG and cEEG samples during normal resting state, during movements, and during electrographic events based on video replay and EEG. We will select 60 s intervals during each type of events, as many as we can obtain during a 1 hr EEG session/subject. We apply the same filter setting and sample rate (500 Hz) for both systems. Next we compute sample correlation between the zEEG and cEEG within 1.25 s sliding windows. We compare power spectral density change within the same system between resting state EEG, movement artifacts and electrographic events (inter-ictal spikes, seizures, spikes, spike and wave, other epileptic discharges). We quantify the spectral difference between these events by computing a discriminability index using ROC analysis. ROC analysis tests how an 'ideal observer' would be able to discriminate between those samples based on the spectral differences relative to the grand truth (based on the classification by our expert neurologists) without knowing what period those samples were extracted from.

For statistical an analysis, a four-way ANOVA will be used, where the 4 factors are: age group (pediatric, adult), system (zEEG, cEEG), tasks (1-5), and recording sites (10-20 system). The dependent variable is the spectral signal to noise ratio (SNR) computed as the spectral mean (divided by the spectral standard deviation.

Spec Aim 3: The maximum achievable correct score per subject is 7 for the first test and 7 for the second. Next, we combine the scores from the sessions within the same system as follows. If the scores from the first set are denoted as clinical EEG [a1 a2 a3 a4 a5 a6] and zEEG [b1 b2 b3 b4 b5 b6] and in the second set as clinical EEG [a7 a8 a9 a10 a11 a12] and zEEG [b7 b8 b9 b10 b11 b12], then we compute the difference scores as DclinicalEEG-zEEG (a1- b1, a2-b2, … ,a12-b12). Our NULL is that the evaluations by the two experts will be concordant between the two systems and the D scores will not be different from zero. The alternative is that the expert evaluations of the two systems are discordant; hence the distribution of D scores is significantly different from zero. We will calculate a one-sample student T-test to compare the deviation of distribution from zero.

We will ask 16 experts to provide their responses on testing the samples. We will make the test to be performed on-line. The EEG samples will be de-identified. Gain, filtering and sampling rate will be identical for all samples and between both systems. No more than 1 min is needed per item. The total test with the 5 questions, about 10 samples (clinical EEG set and zEEG set) will take about 10 minutes to take. According to our power test, a sample size=16, STD=3 (in the range of 1 to 7) sample average D=2 the power of statistical test is 84.7%, sufficient for statistical conclusion to be drawn. Hence, the sample size = 16 suffices the desired statistical power of >80% (http://rpsychologist.com/d3/NHST/). By convention, 80% is an acceptable level of power (Ellis, 2010).

Being tested
Electroencephalography
Keywords
Epilepsy, EEG, Wireless, Dry electrode, mobile
Medical subject headings
Epilepsy

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ElectroencephalographyDevice

    Simultaneous recording of electroencephalogram by conventional EEG device and the Zeto EEG device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Technical equivalence

    Equivalence of signal to noise ratio of EEG signal

    Measured: 2022-2023

Secondary outcomes (1)
  1. Clinical equivalence

    Equivalence of data quality for clinical diagnostic purposes

    Measured: 2022-2023

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Nov 2021
  2. Study startJan 2022 (estimated)
  3. Primary completionDec 2022 (estimated)
  4. Study completionMar 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05123469
Sponsor's protocol ID
2017110124
Status last verified
Nov 2021
First submitted
4 Nov 2021
Last updated
17 Nov 2021
Results posted
No
Data monitoring committee
Yes
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Epilepsy and EEG With Periodic Abnormalities, run by University of Texas at Austin at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 17 Nov 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Zoltan Nadasdy, Ph.D. (323-697-6714, zoltan@utexas.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Technical equivalence (time frame: 2022-2023). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Nov 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in