AzTrials
AzTrials

Left Ventricular Assist DeviceNCT05063006

Exercise Tolerance in Patients With Implanted Left Ventricular Assist Device

A study testing Cardiopulmonary exercise tests with maintained baseline optimal pump speed settings. and Cardiopulmonary exercise test with gradually increased pump speed depending on live echocardiographic imaging. in people with Left Ventricular Assist Device, run by Karol Wierzbicki at 1 site in Poland.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To evaluate the concept of dynamic pump speed optimization based on the echocardiographic assessment of aortic valve opening during cardiopulmonary exercise test. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Left Ventricular Assist Device
What is being tested?
Cardiopulmonary exercise tests with maintained baseline optimal pump speed settings. and Cardiopulmonary exercise test with gradually increased pump speed depending on live echocardiographic imaging.
Could I receive a placebo?
No, everyone receives an active treatment
How many people
22 participants
Where
1 sitePoland
Study dates
15 Feb 2017to 4 Aug 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with implanted cardioverter-defibrillator and third-generation centrifugal CF-LVAD with hydrodynamic bearing (HVAD, Medtronic, Minnesota, United States), at least three months after surgery.

Who cannot join

  • Hemodynamic instability.
  • Non-therapeutic anticoagulation.
  • Device or intracardiac thrombus.
  • Inflammation.
  • Active bleeding.

Trial locations and contacts

1 site in 1 country.

Poland1 site
  • John Paul II Hospital

    Krakow, Lesser Poland Voivodeship, 31-202

Other trials in Poland

About this study

To evaluate the concept of dynamic pump speed optimization based on the echocardiographic assessment of aortic valve opening during cardiopulmonary exercise test.

Read the detailed description

Left ventricular assist devices (LVAD) are becoming a destination therapy in patients with end-stage left ventricular dysfunction. Current generation pumps operate with a fixed rotation speed without the capability of automated speed adjustment. It was shown that acceleration of the pump speed during stress test increases the maximum exercise tolerance. Periodic aortic valve opening (AVO) is used to set up an optimal resting pump speed. The study aimed to evaluate the concept of dynamic pump speed optimization based on the echocardiographic assessment of AVO during the cardiopulmonary exercise test (CPET).

Patients with implanted third-generation LVADs with hydrodynamic bearing (HVAD, Medtronic, MN, USA) are prospectively enrolled. Two CPETs are performed after resting speed optimization. The first one with maintained baseline pump speed settings, and the second one with gradually increased speed depending on live echocardiographic imaging. The sequence of tests is random.

Being tested
Cardiopulmonary exercise tests with maintained baseline optimal pump speed settings., Cardiopulmonary exercise test with gradually increased pump speed depending on live echocardiographic imaging.
Keywords
left ventricular assist device, cardiopulmonary exercise test, stress echocardiography, heart failure, mechanical circulatory support, peak VO2
Medical subject headings
Heart Failure

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Cardiopulmonary exercise tests with maintained baseline optimal pump speed settings.Other

    Optimal resting LVAD speed settings is defined as periodic aortic valve opening while maintaining the central position of the intraventricular septum, minimizing mitral regurgitation, and preserving the mean systemic blood pressure above 65 mmHg. The aim is to achieve an aortic valve opening ratio of around 25-33% by changing the pump speed at resting conditions.

  • Cardiopulmonary exercise test with gradually increased pump speed depending on live echocardiographic imaging.Other

    During the modified speed exercise, when the aortic valve opening ratio rises above 50%, the pump speed is increased by 100 revolutions per minute (RPM). As the aortic valve remains closed the RPM is lowered by 100. Speed increment is not greater than 100 RPM per 45 seconds to enable an echocardiographic analysis of resulting changes and prevent suction events. There is no determined target speed, neither per time period nor maximal.

Study groups in NCT05063006
Study groupRoleWhat they receive
LVAD pump speed dynamically adjustedExperimentalNot described
Receives: Other: Cardiopulmonary exercise test with gradually increased pump speed depending on live echocardiographic imaging.
LVAD pump at optimal resting speedActive comparatorNot described
Receives: Other: Cardiopulmonary exercise tests with maintained baseline optimal pump speed settings.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Echocardiographic appraisal of aortic valve opening during cycle ergometer exercise.

    Assessment of aortic valve opening during cycle ergometer exercise in LVAD patients.

    Measured: Immediately, during cycle ergometer exercise

Secondary outcomes (5)
  1. Change in oxygen consumption

    By using the cardiopulmonary exercise test

    Measured: Immediately, during cycle ergometer exercise

  2. Change in perceived exertion

    By using the Borg rating of perceived exertion scale. Score 6-20 (6 - no exertion, 20 - maximal exertion)

    Measured: Immediately, during cycle ergometer exercise

  3. Change in pump speed

    By assessing pump speed (RPM)

    Measured: Immediately, during cycle ergometer exercise.

  4. Change in pump flow

    By assessing pump flow (l/min)

    Measured: Immediately, during cycle ergometer exercise

  5. Change in pump power

    By assessing pump power (W)

    Measured: Immediately, during cycle ergometer exercise

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Sep 2021
  2. Study start15 Feb 2017
  3. Primary completion31 Jul 2020
  4. Study completion4 Aug 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Sequential
Model description
prospective crossover AB/BA study
Masking
None (open label)
Enrolment
22 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05063006
Sponsor's protocol ID
NB.0710.003.2021P
Status last verified
Oct 2021
First submitted
16 Sep 2021
Last updated
21 Oct 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Cardiopulmonary exercise tests with maintained baseline optimal pump speed settings. and Cardiopulmonary exercise test with gradually increased pump speed depending on live echocardiographic imaging. in people with Left Ventricular Assist Device, run by Karol Wierzbicki at 1 site in Poland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 21 Oct 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Poland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Echocardiographic appraisal of aortic valve opening during cycle ergometer exercise. (time frame: Immediately, during cycle ergometer exercise). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Oct 2021.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in