Coronary Artery DiseaseDECALCIFYNCT04960319
Rotablation vs Intravascular Lithotripsy in Calcified Coronary Lesions
A study testing Intravascular Lithotripsy in people with Coronary Artery Disease and Calcification, run by Medical Care Center Prof. Mathey, Prof. Schofer, Ltd..
Trial summary
Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease, Calcification
- What is being tested?
- Intravascular Lithotripsy
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 100 participants
- Where
- No sites listed yet
- Study dates
- Jan 2022to Jun 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject age ≥ 18 years
- Subject has been informed of the nature of the study, agrees to participate and has signed a Medical Ethics Committee approved consent form, understands the duration of the study, agrees to attend follow-up visits
- LVEF >25%
- Single de-novo target lesion with stenosis ≥ 70% and < 100% or ≥ 50% and < 70% with evidence of ischemia, or FFR ≤ 0.80, or lumen area ≤ 4.0 mm2 (≤ by 6.0mm2 in left main) IVUS or OCT
- Target vessel RVD ≥ 2.5 mm and ≤4.0 mm
- Lesion length ≤ 60 mm
- Lesion site severe calcification: Angiographic radio-opacities prior to contrast involving both sides of arterial wall with total calcium length ≥10 mm, or presence of ≥270° of calcium on at least one cross section by IVUS or OCT or incomplete balloon expansion at 12 atm
- Target lesion was traversed by a guide wire
Who cannot join
- Failure to successfully cross the target lesion with the guidewire
- Target lesion in a coronary artery bypass graft
- In-stent-Restenosis
- Thrombus in the target vessel
- Chronic total occlusion in the target vessel
- ST-elevation myocardial infarction (STEMI) within the last 4 weeks prior to enrollment
Show all 16Show fewer
- Stroke within the last 3 months prior to enrollment
- Decompensated heart failure
- Life expectancy of less than one year
- Chronic kidney disease (serum creatinine > 2.5mg/dl)
- Pregnant or lactating females
- Receiving dialysis or immunosuppressant therapy
- Platelet Count < 100.000mm3 or > 600.000mm3
- Significant gastrointestinal bleeding or any coagulopathy that would contraindicate the use of antiplatelet therapy
- Known allergies or sensitivity to heparin, aspirin, other anticoagulant/antiplatelet therapies or contrast media that cannot be adequately pre-treated prior to index procedure
- Surgical procedure within the last 30 days prior to enrollment
Trial locations and contacts
No sites are listed yet.
About this study
Official title: Prospective, ranDomized, Controlled, multicEnter Study for the Treatment of CALCIFied Coronary Artery Lesions With Rotational Atherectomy vs Intravascular LithotripsY
Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions
Read the detailed description
- Introduction Calcified coronary lesions are frequently observed and with increasing age and comorbidities of the patients they become even more prevalent (1,2). Calcified lesions are often difficult to dilate by conventional angioplasty leading to vessel perforation, dissection, or stent under-expansion, which impact survival, myocardial infarction rates, and target lesion revascularization (3 - 6). Lesion preparation before stent implantation has been strongly recommended using high-pressure dilatation, scoring/cutting balloons, or rotational atherectomy (RA) devices (7-12). RA can effectively modify calcified plaques by differential cutting, facilitating balloon dilatation, plaque fracture, stent delivery, and expansion (11). Patients undergoing RA experienced various clinical and angiographic complications, including vasospasm, perforation, short term vessel closure, side branch loss, and slow-flow/no-reflow resulting in stroke, myocardial infarction, and death (12). In the PREPARE-CALC trial (The Comparison of Strategies to Prepare Severely Calcified Coronary Lesions Trial) comparing RA and scoring or cutting balloons before drug-eluting stent implantation achieved a higher procedural success in RA (98% versus 81%), complications including larger dissection, perforation, and pericardial effusion were seen in 3%, 4%, and 3% of cases, respectively, in-hospital MACE occurred in 2% of cases (13). In the ORBIT II trial (14) an alternative atherectomy device was used which is based on the same mechanism of action as RA. In this trial the primary effectiveness performance goal, defined as successful stent delivery with residual stenosis < 50% and without in-hospital MACE, was not achieved in 11.1 % and the in-hospital MACCE rate was at 9.8 %, the rate of periprocedural myocardial infarction (MI), defined as CK-MB level > 3x ULN at discharge was 9.3% (non-Q-wave MI of 8.6 % and Q-wave MI of 0.7 %). Peri-procedural MI based on the 4th Universal Definition (15) after RA or ORBIT atherectomy have not been reported so far. Intravascular lithotripsy (IVL) disrupts subendothelial calcification by electrohydraulic-generated sonic pressure waves (16,17). In a recently published multicenter registry 78 patients were assigned to primary IVL therapy for patients with calcified de-novo lesions (n=39 lesions), secondary IVL therapy for patients with calcified lesions in which non-compliant balloon dilatation failed (n=22 lesions), and tertiary IVL therapy in patients with stent under expansion after previous stenting (n=17 lesions). The primary endpoint of strategy success (stent expansion with <20% in-stent residual stenosis) was reached in 84.6% with de-novo lesions with only 3 Type B dissections and no in-hospital MACCE (18). Recently Intravascular Lithotripsy for Treatment of Severely Calcified Coronary Artery Disease (Disrupt CAD III) Study (19) has been presented using the same in- and exclusion criteria as the ORBIT II study. The performance of IVL was compared with the performance of the ORBIT device, as being reported in the literature (14). The primary safety endpoint (cardiac death, or myocardial infarction, or target vessel revascularization) as well as the primary effectiveness endpoint (successful stent delivery with residual stenosis < 50 % and without in-hospital MACE) were 92.2 %, which were non-inferior to those reported in the ORBIT II study. Stent expansion was measured by QCA, data on OCT-based measurements of stent expansion in comparison to RA is not available. The rate of in-hospital peri-procedural MI, defined as CK-MB level > 3x ULN at discharge, was 6.8 %. Peri-procedural myocardial infarction and injury are associated with an increased rate of cardiovascular events at 30 days in patients undergoing elective coronary stenting (20). In order to evaluate the effectiveness of IVL in comparison to RA based on OCT- measurements of stent expansion and to study the incidence of in-hospital MACCE following either RA or IVL, we aim to perform a randomized trial.
- Device Description and Intended Use Devices used in this study are commercially available and should be used according to labeled indications and the Manufacturers' Instructions for Use (IFU). Reference each device's IFU for a summary of the necessary training and experience needed to use the device and a description of the procedures involved in the use of the device. 2.1. Intravascular Lithotripsy System The Intravascular Lithotripsy System (Shockwave Medical, Inc., Santa Clara, CA) is designed for the treatment of calcified coronary and peripheral artery stenosis. It is made up of three components: a battery-powered rechargeable generator capable of producing 3 kV energy and preprogramed to deliver a fixed number of pulses per balloon, a cable connector that links the generator with the catheter and a single-use sterile catheter with a semi-compliant balloon and three miniaturized lithotripsy emitters distributed along the length of the balloon. These emitters convert electrical energy into transient acoustic pressure pulses (1 pulse/s for a maximum of 80 pulses per catheter). IVL balloons are available in sizes ranging from 2.5 to 4.0 mm, with a unique maximum length of 12 mm. After the lithotripsy balloon is inflated to 405 kPa, pulsatile energy is emitted for 10 seconds from two emitters localized within the balloon (the distal emitter is slightly more central to enhance flexibility, whereas the proximal emitter is located near the proximal end of the balloon); the balloon is then inflated to 608 kPa. These balloons are compatible with 5 and 6 Fr guide catheters but have a rather large crossing profile of 0.043-0.046 inches. Detailed information can be found in the device related IFU. 2.2. RotablatorTM Rotational Atherectomy System The RotablatorTM Rotational Atherectomy System (Boston Scientific Corp, MA) is designed for the treatment of calcified coronary artery lesions. It is made up of three components: a nickel-plated elliptic burr coated with diamond microscopic crystals that is available in sizes ranging from 1.25 to 2.50 mm diameter; a single advancer that can transmit rotational speed to the burr and is connected with a gas-driven turbine; and a control console and foot pedal. An ultrathin (0.009 inch) steerable dedicated guidewire (RotaWire) of length 330 mm is used to cross the calcified lesion; it is available in a floppy version or an extra support version, useful primarily in the treatment of aorto-ostial lesions. The RotaWire must be placed in the main vessel and other guidewires have to be removed from side branches to avoid wire cutting or perforation. When the burr is proximal to the lesion, rotablation can be started with short burr runs (<20 seconds) at a rotational speed of 135.000-180.000 rpm. A burr-to-artery ratio = 0.5-0.75 is adequate in most lesions as an initial approach, but occasionally it may be necessary to increase the burr size with a step-up approach. Fluoroscopic, acoustic and tactile signals should be monitored to avoid significant deceleration in rotational speed (>5,000 rpm), which is associated with complications. Detailed information can be found in the device related IFU.
- Objectives
The objective of this prospective, 1:1 randomized, controlled, multicenter trial is to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions.
- Conditions
- Coronary Artery Disease, Calcification
- Being tested
- Intravascular Lithotripsy
- Keywords
- Intravascular Lithotripsy, Rotational Atherectomy
- Medical subject headings
- Coronary Artery Disease, Calcinosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Intravascular LithotripsyDevice
Coronary Angiography. When the anatomic inclusion criteria are met, traverse the lesion with a guidewire. If traversal fails, assign the subject to the registry. After wire traversal has been documented by cine angiography, angiographic, OCT-defined or balloon expansion criteria are met, subject is enrolled. Blood sample for Troponin (hs TnT) baseline measurement has to be taken. The subjects will be randomized in a 1:1 fashion to treatment with either IVL or RA.
| Study group | Role | What they receive |
|---|---|---|
| Intravascular Lithotripsy | Experimental | Study Device Treatment: IVL balloon catheter size is chosen in a 1:1 ratio to the distal reference vessel diameter. If the IVL balloon cannot be delivered into the target lesion a Guide catheter extension is recommended. The balloon catheter is then inflated to 4 ATM and 10 impulses are delivered. The balloon is then inflated to 6 ATM and deflated to reestablish blood flow. Up to 80 impulses can subsequently be delivered and the balloon can be repositioned within the lesion. In multiple lesions with different reference vessel diameters different sizes of IVL balloon can be used. Receives: Device: Intravascular Lithotripsy |
| Rotational Atherectomy | Active comparator | Control group treatment: Rotablation should be performed as described in the ESC-Consensus document. Burr/vessel-ratio is 0.5 - 0.75. The use of different burr sizes as well as the use of a temporary pacemaker is left to the operator's discretion. Receives: Device: Intravascular Lithotripsy |
What is being measured
The primary outcome is the main question the study is designed to answer.
Percent of stent expansion evaluated by Optical Coherence Tomography assessed by core lab.
Primary Effectiveness endpoint
Measured: at the end of the intervention
Rate of in-hospital MACCE
primary Safety endpoint
Measured: 72 hours
Secondary outcomes (2)
Percentage of mean stent expansion evaluated by optical coherence tomography as assessed by core lab.
Secondary Effectiveness Endpoint
Measured: at the end of the intervention
Rate of peri-procedural myocardial injury ,Peri-procedural myocardial infarction, Slow flow/no-reflow
secondary safety endpoints
Measured: 72 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Jul 2021
- Study startJan 2022 (estimated)
- Primary completionJul 2023 (estimated)
- Study completionJun 2024 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions. An interim analysis after enrollment of 50 patients randomized will be performed. Based on the result the sample size will be calculated.
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 100 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Medical Care Center Prof. Mathey, Prof. Schofer, Ltd.
- Sponsor type
- University, hospital or other
- Collaborators
- Shockwave Medical, Inc., Asklepios proresearch
- Responsible party
- Sponsor
- Investigators
- Joachim Schofer, MD, PhD, Principal investigator, Medical Care Center Prof. Mathey, Prof. Schofer
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04960319
- Sponsor's protocol ID
- DECALCIFY
- Acronym
- DECALCIFY
- Status last verified
- Aug 2021
- First submitted
- 2 Jul 2021
- Last updated
- 17 Aug 2021
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: all IPD that underlie results in a publication
Study at a glance
From the registry record, last updated by the sponsor on 17 Aug 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective, ranDomized, Controlled, multicEnter Study for the Treatment of CALCIFied Coronary Artery Lesions With Rotational Atherectomy vs Intravascular LithotripsY
- ClinicalTrials.gov ID
- NCT04960319
- Acronym / sponsor ID
- DECALCIFY / DECALCIFY
- Conditions
- Coronary Artery Disease, Calcification
- Keywords
- Intravascular Lithotripsy, Rotational Atherectomy
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 100 participants (estimated)
- Lead sponsor
- Medical Care Center Prof. Mathey, Prof. Schofer, Ltd.University, hospital or other
- Collaborators
- Shockwave Medical, Inc., Asklepios proresearch
- Study start
- Jan 2022 (estimated)
- Primary completion
- Jul 2023 (estimated)
- Study completion
- Jun 2024 (estimated)
- First posted
- 13 Jul 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions
Detailed description
- Introduction Calcified coronary lesions are frequently observed and with increasing age and comorbidities of the patients they become even more prevalent (1,2). Calcified lesions are often difficult to dilate by conventional angioplasty leading to vessel perforation, dissection, or stent under-expansion, which impact survival, myocardial infarction rates, and target lesion revascularization (3 - 6). Lesion preparation before stent implantation has been strongly recommended using high-pressure dilatation, scoring/cutting balloons, or rotational atherectomy (RA) devices (7-12). RA can effectively modify calcified plaques by differential cutting, facilitating balloon dilatation, plaque fracture, stent delivery, and expansion (11). Patients undergoing RA experienced various clinical and angiographic complications, including vasospasm, perforation, short term vessel closure, side branch loss, and slow-flow/no-reflow resulting in stroke, myocardial infarction, and death (12). In the PREPARE-CALC trial (The Comparison of Strategies to Prepare Severely Calcified Coronary Lesions Trial) comparing RA and scoring or cutting balloons before drug-eluting stent implantation achieved a higher procedural success in RA (98% versus 81%), complications including larger dissection, perforation, and pericardial effusion were seen in 3%, 4%, and 3% of cases, respectively, in-hospital MACE occurred in 2% of cases (13). In the ORBIT II trial (14) an alternative atherectomy device was used which is based on the same mechanism of action as RA. In this trial the primary effectiveness performance goal, defined as successful stent delivery with residual stenosis < 50% and without in-hospital MACE, was not achieved in 11.1 % and the in-hospital MACCE rate was at 9.8 %, the rate of periprocedural myocardial infarction (MI), defined as CK-MB level > 3x ULN at discharge was 9.3% (non-Q-wave MI of 8.6 % and Q-wave MI of 0.7 %). Peri-procedural MI based on the 4th Universal Definition (15) after RA or ORBIT atherectomy have not been reported so far. Intravascular lithotripsy (IVL) disrupts subendothelial calcification by electrohydraulic-generated sonic pressure waves (16,17). In a recently published multicenter registry 78 patients were assigned to primary IVL therapy for patients with calcified de-novo lesions (n=39 lesions), secondary IVL therapy for patients with calcified lesions in which non-compliant balloon dilatation failed (n=22 lesions), and tertiary IVL therapy in patients with stent under expansion after previous stenting (n=17 lesions). The primary endpoint of strategy success (stent expansion with <20% in-stent residual stenosis) was reached in 84.6% with de-novo lesions with only 3 Type B dissections and no in-hospital MACCE (18). Recently Intravascular Lithotripsy for Treatment of Severely Calcified Coronary Artery Disease (Disrupt CAD III) Study (19) has been presented using the same in- and exclusion criteria as the ORBIT II study. The performance of IVL was compared with the performance of the ORBIT device, as being reported in the literature (14). The primary safety endpoint (cardiac death, or myocardial infarction, or target vessel revascularization) as well as the primary effectiveness endpoint (successful stent delivery with residual stenosis < 50 % and without in-hospital MACE) were 92.2 %, which were non-inferior to those reported in the ORBIT II study. Stent expansion was measured by QCA, data on OCT-based measurements of stent expansion in comparison to RA is not available. The rate of in-hospital peri-procedural MI, defined as CK-MB level > 3x ULN at discharge, was 6.8 %. Peri-procedural myocardial infarction and injury are associated with an increased rate of cardiovascular events at 30 days in patients undergoing elective coronary stenting (20). In order to evaluate the effectiveness of IVL in comparison to RA based on OCT- measurements of stent expansion and to study the incidence of in-hospital MACCE following either RA or IVL, we aim to perform a randomized trial.
- Device Description and Intended Use Devices used in this study are commercially available and should be used according to labeled indications and the Manufacturers' Instructions for Use (IFU). Reference each device's IFU for a summary of the necessary training and experience needed to use the device and a description of the procedures involved in the use of the device. 2.1. Intravascular Lithotripsy System The Intravascular Lithotripsy System (Shockwave Medical, Inc., Santa Clara, CA) is designed for the treatment of calcified coronary and peripheral artery stenosis. It is made up of three components: a battery-powered rechargeable generator capable of producing 3 kV energy and preprogramed to deliver a fixed number of pulses per balloon, a cable connector that links the generator with the catheter and a single-use sterile catheter with a semi-compliant balloon and three miniaturized lithotripsy emitters distributed along the length of the balloon. These emitters convert electrical energy into transient acoustic pressure pulses (1 pulse/s for a maximum of 80 pulses per catheter). IVL balloons are available in sizes ranging from 2.5 to 4.0 mm, with a unique maximum length of 12 mm. After the lithotripsy balloon is inflated to 405 kPa, pulsatile energy is emitted for 10 seconds from two emitters localized within the balloon (the distal emitter is slightly more central to enhance flexibility, whereas the proximal emitter is located near the proximal end of the balloon); the balloon is then inflated to 608 kPa. These balloons are compatible with 5 and 6 Fr guide catheters but have a rather large crossing profile of 0.043-0.046 inches. Detailed information can be found in the device related IFU. 2.2. RotablatorTM Rotational Atherectomy System The RotablatorTM Rotational Atherectomy System (Boston Scientific Corp, MA) is designed for the treatment of calcified coronary artery lesions. It is made up of three components: a nickel-plated elliptic burr coated with diamond microscopic crystals that is available in sizes ranging from 1.25 to 2.50 mm diameter; a single advancer that can transmit rotational speed to the burr and is connected with a gas-driven turbine; and a control console and foot pedal. An ultrathin (0.009 inch) steerable dedicated guidewire (RotaWire) of length 330 mm is used to cross the calcified lesion; it is available in a floppy version or an extra support version, useful primarily in the treatment of aorto-ostial lesions. The RotaWire must be placed in the main vessel and other guidewires have to be removed from side branches to avoid wire cutting or perforation. When the burr is proximal to the lesion, rotablation can be started with short burr runs (<20 seconds) at a rotational speed of 135.000-180.000 rpm. A burr-to-artery ratio = 0.5-0.75 is adequate in most lesions as an initial approach, but occasionally it may be necessary to increase the burr size with a step-up approach. Fluoroscopic, acoustic and tactile signals should be monitored to avoid significant deceleration in rotational speed (>5,000 rpm), which is associated with complications. Detailed information can be found in the device related IFU.
- Objectives
The objective of this prospective, 1:1 randomized, controlled, multicenter trial is to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
- Model description
- Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions. An interim analysis after enrollment of 50 patients randomized will be performed. Based on the result the sample size will be calculated.
| Arm | Type | Receives |
|---|---|---|
| Intravascular Lithotripsy | Experimental | Device: Intravascular LithotripsyStudy Device Treatment: IVL balloon catheter size is chosen in a 1:1 ratio to the distal reference vessel diameter. If the IVL balloon cannot be delivered into the target lesion a Guide catheter extension is recommended. The balloon catheter is then inflated to 4 ATM and 10 impulses are delivered. The balloon is then inflated to 6 ATM and deflated to reestablish blood flow. Up to 80 impulses can subsequently be delivered and the balloon can be repositioned within the lesion. In multiple lesions with different reference vessel diameters different sizes of IVL balloon can be used. |
| Rotational Atherectomy | Active comparator | Device: Intravascular LithotripsyControl group treatment: Rotablation should be performed as described in the ESC-Consensus document. Burr/vessel-ratio is 0.5 - 0.75. The use of different burr sizes as well as the use of a temporary pacemaker is left to the operator's discretion. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (8 listed)
- Subject age ≥ 18 years
- Subject has been informed of the nature of the study, agrees to participate and has signed a Medical Ethics Committee approved consent form, understands the duration of the study, agrees to attend follow-up visits
- LVEF >25%
- Single de-novo target lesion with stenosis ≥ 70% and < 100% or ≥ 50% and < 70% with evidence of ischemia, or FFR ≤ 0.80, or lumen area ≤ 4.0 mm2 (≤ by 6.0mm2 in left main) IVUS or OCT
- Target vessel RVD ≥ 2.5 mm and ≤4.0 mm
Key exclusion criteria (16 listed)
- Failure to successfully cross the target lesion with the guidewire
- Target lesion in a coronary artery bypass graft
- In-stent-Restenosis
- Thrombus in the target vessel
- Chronic total occlusion in the target vessel
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Intravascular LithotripsyCoronary Angiography. When the anatomic inclusion criteria are met, traverse the lesion with a guidewire. If traversal fails, assign the subject to the registry. After wire traversal has been documented by cine angiography, angiographic, OCT-defined or balloon expansion criteria are met, subject is enrolled. Blood sample for Troponin (hs TnT) baseline measurement has to be taken. The subjects will be randomized in a 1:1 fashion to treatment with either IVL or RA. | Device | Intravascular Lithotripsy, Rotational Atherectomy |
Primary outcome
Percent of stent expansion evaluated by Optical Coherence Tomography assessed by core lab.
Time frame: at the end of the intervention
Primary Effectiveness endpoint
Rate of in-hospital MACCE
Time frame: 72 hours
primary Safety endpoint
2 secondary outcomes
Percentage of mean stent expansion evaluated by optical coherence tomography as assessed by core lab.
Time frame: at the end of the intervention
Rate of peri-procedural myocardial injury ,Peri-procedural myocardial infarction, Slow flow/no-reflow
Time frame: 72 hours
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Aug 2021.
- Individual participant dataSharing planned: Yes. all IPD that underlie results in a publication
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Joachim Schofer, MD, PhD principal investigator
Medical Care Center Prof. Mathey, Prof. Schofer
Questions about this trial
What is this clinical trial studying?
A study testing Intravascular Lithotripsy in people with Coronary Artery Disease and Calcification, run by Medical Care Center Prof. Mathey, Prof. Schofer, Ltd..
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 17 Aug 2021. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Joachim Schofer, MD, PhD (+4940889009889, schofer@herz-hh.de), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Percent of stent expansion evaluated by Optical Coherence Tomography assessed by core lab. (time frame: at the end of the intervention). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Aug 2021.