Investigation in Corneal Sensation and Contact Lens Wear

A study testing Tactile Esthesiometer Prototype, Liquid Jet Esthesiometer Prototype and Cochet Bonnet esthesiometer in people with Cornea and Sense Loss; Cornea, run by Daniela Nosch at 1 site in Switzerland.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The aim is to find out more about how corneal sensory fibres react to different types of stimuli (liquid / tactile / nylon thread) and how this can be consciously perceived by the individual. Read more about this study

Who is it for?
Ages 18 to 50 yearsHealthy volunteers can take part
Conditions the study is for
Cornea, Sense Loss; Cornea
What is being tested?
Tactile Esthesiometer Prototype, Liquid Jet Esthesiometer Prototype and Cochet Bonnet esthesiometer
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
111 participants
Where
1 siteSwitzerland
Study dates
1 May 2021to 20 Dec 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Group A:
  • Silicone hydrogel (SiHy) CL wear at least 3 days per week and at least 8 hours per day; 18 - 50 years of age; healthy eyes with OSDI </= 13
  • Group B:
  • Rigid gas permeable (RGP) CL wear at least 3 days per week and at least 8 hours per day; 18 - 50 years of age; healthy eyes with OSDI </= 13
  • Group C:
  • No current CL wear for at least 3 months; 18 - 50 years of age; healthy eyes with OSDI </= 13

Who cannot join

  • Systemic disease that may affect ocular health, such as diabetes
  • Injury and history of operations on the anterior segment of the eye
  • regular application of systemic or ocular medication known to affect the tear film, specifically on the day of measurement

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • Institute of Optometry, FHNW

    Olten, Canton of Solothurn, 4600

Other trials in Switzerland

About this study

Official title: Investigation in Variability and Repeatability of Corneal Sensation in a Normal Population and Contact Lens Wearers

The aim is to find out more about how corneal sensory fibres react to different types of stimuli (liquid / tactile / nylon thread) and how this can be consciously perceived by the individual. Is it possible to generate a stimulus that delivers a repeatable and reliable response within a useful stimulus force range which allows an interpretation / evaluation of normal / expected activity of superficial nerve fibres in the cornea? The study group will be divided into three groups of individuals: two groups with different types of contact lenses (CL) and one without CL, as sensitivity changes are thought to occur with CL wear. A very interesting research question is to find out, if such sensitivity differences can be detected with the nature of the stimuli applied in this study.

Read the detailed description

The aim of this study is to gain more physiological knowledge about ocular surface sensation (corneal sensitivity), with application of three different concepts employing different types of stimuli for triggering a response from the pain sensitive nerve endings in the superficial cornea: 1) tactile method: a round plastic nozzle (2 mm diameter) is applied to the ocular surface with a defined, low force for a duration of 100ms. 2) liquid jet method: a liquid jet (isotonic saline) of a temperature to match ocular surface temperature is applied to the ocular surface with low pressure and low volume, from a distance of 15 mm.3) commercially available Cochet Bonnet esthesiometer (nylon thread). The study group will be divided into three groups of individuals: two groups with different types of contact lenses (CL) and one without CL, as sensitivity changes are thought to occur with CL wear. A very interesting research question is to find out, if such sensitivity differences can be detected with the nature of the stimuli applied in this study.

Current knowledge about human corneal sensitivity is limited, as applied methods for ocular surface sensation measurement are limited with regards to reproducibility / accuracy.

Corneal sensitivity represents a neurological response from the free nerve endings within the epithelium. They are sensitive to mechanical, electrical, chemical or thermal stimuli and hence have a protective function for the cornea. Corneal nerves play an important role in cell growth and proliferation of epithelial cells, wound healing and repair. In experimental studies, corneal denervation has been reported to result in epithelial changes: increased permeability, decreased proliferation, changed appearance and delayed wound healing. Therefore, intact corneal innervation is required to maintain the integrity of a normal corneal epithelium. Corneal sensory nerves are believed to play an important role in maintaining the resting tear flow, as their afferent impulses from the ocular surface lead to a reflex response, best described by the lacrimal functional unit: an integrated system comprising the ocular surface tissues (cornea, corneal limbus, conjunctiva, conjunctival blood vessels, and eyelids), the tear secreting components (main and accessory lacrimal glands, meibomian glands, conjunctival goblet, and epithelial cells), and the sensory and motor nerves that connect them.

Current knowledge about ocular surface sensitivity is insufficient, as currently available measurement possibilities lack repeatability and accuracy. Before a new instrument can be developed, more research is required, in order to find a suitable concept for precise sensitivity measurement. For this purpose, two new different concepts with different / new stimulus types will be applied repeatably on healthy eyes in this study. The aim is to find out more about how corneal sensory fibres react to different types of stimuli (liquid / tactile / nylon thread) and how this can be consciously perceived by the individual. Is it possible to generate a stimulus that delivers a repeatable and reliable response within a useful stimulus force range which allows an interpretation / evaluation of normal / expected activity of superficial nerve fibres in the cornea? The study group will be divided into three groups of individuals: two groups with different types of contact lenses (CL) and one without CL, as sensitivity changes are thought to occur with CL wear.

Being tested
Tactile Esthesiometer Prototype, Liquid Jet Esthesiometer Prototype, Cochet Bonnet esthesiometer
Keywords
cornea, ocular surface sensation, corneal sensitivity, contact lens wear
Medical subject headings
Corneal Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Tactile Esthesiometer PrototypeDevice

    A round plastic nozzle (1.8mm diameter) used as a stimulus for corneal sensation threshold measurement

  • Liquid Jet Esthesiometer PrototypeDevice

    Balanced salt solution with a pH value similar to the tear film uesd as a liquid jet stimulus for corneal sensation threshold measurement

  • Cochet Bonnet esthesiometerDevice

    A nylon thread (0.12mm diameter) used as a stimulus for corneal sensation threshold measurement

Study groups in NCT04804592
Study groupRoleWhat they receive
Group A: SiHy CLExperimentalSilicone hydrogel (SiHy) CL wear at least 3 days per week and at least 8 hours per day;
Receives: Device: Tactile Esthesiometer Prototype; Device: Liquid Jet Esthesiometer Prototype; Device: Cochet Bonnet esthesiometer
Group B: RGP CLExperimentalRigid gas permeable (RGP) CL wear at least 3 days per week and at least 8 hours per day;
Receives: Device: Tactile Esthesiometer Prototype; Device: Liquid Jet Esthesiometer Prototype; Device: Cochet Bonnet esthesiometer
Group C: no CL wearExperimentalNo current CL wear for at least 3 months;
Receives: Device: Tactile Esthesiometer Prototype; Device: Liquid Jet Esthesiometer Prototype; Device: Cochet Bonnet esthesiometer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Repeatability of mechanical corneal sensation thresholds with the liquid jet protoype esthesiometer

    Evaluation of repeatability of mechanical corneal sensation thresholds for the measurement with the liquid jet esthesiometer prototype instrument (in mbar): the corneal sensation thresholds will be obtained with the double staircase method (with forced choice) and the stimulus represents a liquid jet (consisting of isotonic saline solution).

    Measured: two weeks

  2. Repeatability of mechanical corneal sensation thresholds with the tactile prototype esthesiometer

    Evaluation of variability / repeatability of mechanical corneal sensation thresholds for the measurement with the tactile esthesiometer prototype instrument (in mN): the corneal sensation thresholds will be obtained with the double staircase method (with forced choice) and the stimulus represents a small, round plastic ball.

    Measured: two weeks

  3. Repeatability of mechanical corneal sensation thresholds with the Cochet Bonnet esthesiometer

    Evaluation of repeatability of mechanical corneal sensation thresholds for the measurement with the Cochet Bonnet instrument (in mN): the corneal sensation thresholds will be obtained with the double staircase method (with forced choice) and the stimulus represents a nylon thread, whereby its force is proportional to the length of the nylon thread applied to the corneal surface.

    Measured: two weeks

Secondary outcomes (6)
  1. Correlation between corneal sensation thresholds with the Cochet Bonnet esthesiometer

    Correlation between corneal sensitivity thresholds (in mN) obtained with the Cochet Bonnet esthesiometer

    Measured: one day

  2. Correlation between corneal sensation thresholds with the liquid jet prototype esthesiometer

    Correlation between corneal sensitivity thresholds (in mbar) obtained with the liquid jet prototype esthesiometer

    Measured: one day

  3. Correlation between corneal sensation thresholds with the tactile prototype esthesiometer

    Correlation between corneal sensitivity thresholds (in mN) obtained with the tactile prototype esthesiometer

    Measured: one day

  4. Comparison of corneal sensation thresholds, obtained with the Cochet Bonnet esthesiometer, between the three groups in the study population

    Comparison of corneal sensation thresholds obtained with the Cochet Bonnet esthesiometer between the three groups in the study population

    Measured: two weeks

  5. Comparison of corneal sensation thresholds, obtained with the liquid jet prototype esthesiometer, between the three groups in the study population

    Comparison of corneal sensation thresholds, obtained with the liquid jet prototype esthesiometer, between the three groups in the study population

    Measured: two weeks

  6. Comparison of corneal sensation thresholds, obtained with the tactile prototype esthesiometer, between the three groups in the study population

    Comparison of corneal sensation thresholds, obtained with the tactile prototype esthesiometer, between the three groups in the study population

    Measured: two weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Mar 2021
  2. Study start1 May 2021
  3. Primary completion20 Dec 2021
  4. Study completion20 Dec 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Basic science
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
111 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04804592
Sponsor's protocol ID
2021-00438
Status last verified
Mar 2022
First submitted
11 Mar 2021
Last updated
17 Mar 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Belmonte C, Acosta MC, Gallar J. Neural basis of sensation in intact and injured corneas. Exp Eye Res. 2004 Mar;78(3):513-25. doi: 10.1016/j.exer.2003.09.023.

    PubMed 15106930
  • Bergenske PD, Polse KA. The effect of rigid gas permeable lenses on corneal sensitivity. J Am Optom Assoc. 1987 Mar;58(3):212-5.

    PubMed 3471806
  • Knoll HA, Williams J. Effects of hydrophilic contact lenses on corneal sensitivity. Am J Optom Arch Am Acad Optom. 1970 Jul;47(7):561-3. doi: 10.1097/00006324-197007000-00007. No abstract available.

    PubMed 5270397
  • Millodot M. Does the long term wear of contact lenses produce a loss of corneal sensitivity? Experientia. 1977 Nov 15;33(11):1475-6. doi: 10.1007/BF01918817.

    PubMed 923715
  • Muller LJ, Marfurt CF, Kruse F, Tervo TM. Corneal nerves: structure, contents and function. Exp Eye Res. 2003 May;76(5):521-42. doi: 10.1016/s0014-4835(03)00050-2.

    PubMed 12697417
  • Golebiowski B, Chao C, Stapleton F, Jalbert I. Corneal Nerve Morphology, Sensitivity, and Tear Neuropeptides in Contact Lens Wear. Optom Vis Sci. 2017 Apr;94(4):534-542. doi: 10.1097/OPX.0000000000001063.

    PubMed 28338565
  • Stapleton F, Chao C, Golebiowski B. Topical Review: Effects of Contact Lens Wear on Corneal, Conjunctival, and Lid Margin Sensitivity. Optom Vis Sci. 2019 Oct;96(10):790-801. doi: 10.1097/OPX.0000000000001429.

    PubMed 31592962
  • Golebiowski B, Papas EB, Stapleton F. Factors affecting corneal and conjunctival sensitivity measurement. Optom Vis Sci. 2008 Apr;85(4):241-6. doi: 10.1097/OPX.0b013e3181694f96.

    PubMed 18382334
  • Stapleton F, Golebiowski B, Skotnitsky C, Tan ME, Holden BA. Corneal and conjunctival sensitivity in intolerant contact lens wearers. J Optom. 2015 Jan-Mar;8(1):62-3. doi: 10.1016/j.optom.2014.05.004. Epub 2014 Jun 7. No abstract available.

    PubMed 25649641
  • Golebiowski B, Papas EB, Stapleton F. Corneal and conjunctival sensory function: the impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses. Invest Ophthalmol Vis Sci. 2012 Mar 9;53(3):1177-81. doi: 10.1167/iovs.11-8416.

    PubMed 22281824

Questions about this trial

What is this clinical trial studying?

A study testing Tactile Esthesiometer Prototype, Liquid Jet Esthesiometer Prototype and Cochet Bonnet esthesiometer in people with Cornea and Sense Loss; Cornea, run by Daniela Nosch at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Mar 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Repeatability of mechanical corneal sensation thresholds with the liquid jet protoype esthesiometer (time frame: two weeks). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04804592, which also lists 10 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Mar 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in