Diagnostic Accuracy of Core Stethoscope Auscultation vs. Point of Care Ultrasound in Placement of Endotracheal Tube

A study testing Eko CORE Stethoscope and Point of care ultrasound in people with Intubation Complication, run by Stanford University at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Misplacement of endotracheal tube (ETT) can have devastating complications for patients, some of which include respiratory failure, atelectasis, and pneumothorax. There are a number of ways to verify the correct placement of ETT, with the stethoscope auscultation being commonly used despite its low accuracy (60-65%)… Read more about this study

Who is it for?
Ages Up to 18 years
Conditions the study is for
Intubation Complication
What is being tested?
Eko CORE Stethoscope and Point of care ultrasound
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteUnited States
Study dates
Nov 2025to Nov 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Up to 18 years
  • All sexes
  • No healthy volunteers
  • Child, Adult

Who may be able to join

  • Any patients under the age of 18
  • Surgery requiring an ETT
  • Consent/parental consent to

Who cannot join

  • Possible difficult airway
  • Significant lung pathology
  • with any major cardiac anomaly

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Chynna Villanueva, BS, RN contact

6504986346

chynnav@stanford.edu

United States1 site
  • Lucille Packard Children's Hospital

    Palo Alto, California, 94304

Other trials in United States

About this study

Official title: Assessing Diagnostic Accuracy of Core Stethoscope Auscultation vs. Point of Care Ultrasound in Localizing Correct Placement of Endotracheal Tube

Misplacement of endotracheal tube (ETT) can have devastating complications for patients, some of which include respiratory failure, atelectasis, and pneumothorax.

There are a number of ways to verify the correct placement of ETT, with the stethoscope auscultation being commonly used despite its low accuracy (60-65%) in distinguishing tracheal from bronchial intubation (4-6). The gold standard techniques include Chest X Ray or fiberoptic bronchoscope (7-8), with a recent study showing point-of-care ultrasound. However, these techniques are expensive, time-consuming, often not readily available and require substantial training before users can reliably utilize them. Given intubation is often performed in urgent clinical settings, a technique that can reliably yet efficiently localize ETT would be beneficial.

Tele-auscultation system via Core stethoscope (Eko, Berkeley, CA) has been shown to be effective in identifying pathologic heart murmur (10) yet its potential use in guiding the correct placement of ETT has not been explored. We set out to study the suitability of Core stethoscope in detecting the correct placement of ETT.

Being tested
Eko CORE Stethoscope, Point of care ultrasound

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Eko CORE StethoscopeDevice

    Eko CORE stethoscope will be used as a visual and auditory means of confirming placement of ETT

  • Point of care ultrasoundDevice

    Point of care ultrasound will be used as a means of confirming placement of ETT. This is the "gold standard" used in standard of care

Study groups in NCT04797520
Study groupRoleWhat they receive
TreatmentOtherAll participants will have placement of ETT confirmed using both Core stethoscope and point-of-care ultrasound
Receives: Device: Eko CORE Stethoscope; Device: Point of care ultrasound

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Localization of endotracheal tube placement by the presence/absence of lung pleural linings movement by ultrasound

    Ultrasound placed vertically on the anterior chest of a patient will assess for the presence/absence of the horizontal movement of the two lung pleural linings with respiration.

    Measured: During assessment with point of care ultrasound (10min)

  2. Localization of endotracheal tube placement by the presence/absence of breath sounds detected by Core-Eko augmented stethoscope

    Presence of breath sounds will be assessed and recorded using Core-Eko augmented stethoscope, in conjunction with the smartphone interface over Bluetooth, by auscultating patient's chest. The technology will display breath sounds as a visual soundwave on the smartphone.

    As a result, this will be used to determine location of endotracheal tube (for example, if breath sounds absent in the left lung, we would infer that the tube is in the right bronchus).

    Measured: During assessment with Core-Eko augmented stethoscope auscultation (5min)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Mar 2021
  2. Study startNov 2025 (estimated)
  3. Primary completionNov 2026 (estimated)
  4. Study completionNov 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04797520
Sponsor's protocol ID
60429
Status last verified
Apr 2025
First submitted
10 Mar 2021
Last updated
4 May 2025
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Kollef MH, Legare EJ, Damiano M. Endotracheal tube misplacement: incidence, risk factors, and impact of a quality improvement program. South Med J. 1994 Feb;87(2):248-54. doi: 10.1097/00007611-199402000-00020.

    PubMed 8115893
  • Kerrey BT, Rinderknecht AS, Geis GL, Nigrovic LE, Mittiga MR. Rapid sequence intubation for pediatric emergency patients: higher frequency of failed attempts and adverse effects found by video review. Ann Emerg Med. 2012 Sep;60(3):251-9. doi: 10.1016/j.annemergmed.2012.02.013. Epub 2012 Mar 15.

    PubMed 22424653
  • Jemmett ME, Kendal KM, Fourre MW, Burton JH. Unrecognized misplacement of endotracheal tubes in a mixed urban to rural emergency medical services setting. Acad Emerg Med. 2003 Sep;10(9):961-5. doi: 10.1111/j.1553-2712.2003.tb00652.x.

    PubMed 12957980
  • Bissinger U, Lenz G, Kuhn W. Unrecognized endobronchial intubation of emergency patients. Ann Emerg Med. 1989 Aug;18(8):853-5. doi: 10.1016/s0196-0644(89)80211-2.

    PubMed 2757282
  • Geisser W, Maybauer DM, Wolff H, Pfenninger E, Maybauer MO. Radiological validation of tracheal tube insertion depth in out-of-hospital and in-hospital emergency patients. Anaesthesia. 2009 Sep;64(9):973-7. doi: 10.1111/j.1365-2044.2009.06007.x.

    PubMed 19686482
  • Brunel W, Coleman DL, Schwartz DE, Peper E, Cohen NH. Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position. Chest. 1989 Nov;96(5):1043-5. doi: 10.1378/chest.96.5.1043.

    PubMed 2509149
  • Sivit CJ, Taylor GA, Hauser GJ, Pollack MM, Bulas DI, Guion CJ, Fearon T. Efficacy of chest radiography in pediatric intensive care. AJR Am J Roentgenol. 1989 Mar;152(3):575-7. doi: 10.2214/ajr.152.3.575.

    PubMed 2783812
  • Dietrich KA, Strauss RH, Cabalka AK, Zimmerman JJ, Scanlan KA. Use of flexible fiberoptic endoscopy for determination of endotracheal tube position in the pediatric patient. Crit Care Med. 1988 Sep;16(9):884-7. doi: 10.1097/00003246-198809000-00013.

    PubMed 3402233
  • Ramsingh D, Frank E, Haughton R, Schilling J, Gimenez KM, Banh E, Rinehart J, Cannesson M. Auscultation versus Point-of-care Ultrasound to Determine Endotracheal versus Bronchial Intubation: A Diagnostic Accuracy Study. Anesthesiology. 2016 May;124(5):1012-20. doi: 10.1097/ALN.0000000000001073.

    PubMed 26950708
  • Behere S, Baffa JM, Penfil S, Slamon N. Real-World Evaluation of the Eko Electronic Teleauscultation System. Pediatr Cardiol. 2019 Jan;40(1):154-160. doi: 10.1007/s00246-018-1972-y. Epub 2018 Aug 31.

    PubMed 30171267

Questions about this trial

What is this clinical trial studying?

A study testing Eko CORE Stethoscope and Point of care ultrasound in people with Intubation Complication, run by Stanford University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 4 May 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Ban Tsui, MD (650-200-9107, bantsui@stanford.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Localization of endotracheal tube placement by the presence/absence of lung pleural linings movement by ultrasound (time frame: During assessment with point of care ultrasound (10min)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04797520, which also lists 10 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 May 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in