Healthy VolunteersNCT04773535
Validation of the DyCare® Lynx System for Motion Analysis of the Wrist
An observational study of Healthy Volunteers, run by University of Zurich at 1 site in Switzerland.
Trial summary
This project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras. A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as… Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Healthy Volunteers
- What is being tested?
- 3D Motion analysis
- Type of treatment
- Medical device
- How many people
- 10 participants
- Where
- 1 siteSwitzerland
- Study dates
- 1 Mar 2018to 31 Dec 2019
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: 10 healthy volunteers
Who may be able to join
- 10 test persons with healthy right-dominant hands
- Test Persons older than 18 Years
- Test persons willing and able to give written informed consent to participate in the study
Who cannot join
- Inflammatory disease (e.g. rheumatoid arthritis)
- German language barrier to understand instructions
- Any disease process that would preclude accurate evaluation (e.g. neuromuscular, psychiatric or metabolic disorder)
- Legal incompetence
- Participation in any other medical device or medicinal product study within the previous months that could influence the results of the present study
Trial locations and contacts
1 site in 1 country.
Switzerland1 site
University Hospital Zurich, Clinic of Reconstructive Surgery
Zurich, Canton of Zurich, 8091
About this study
Official title: Validation of the DyCare® Lynx System for Motion Analysis of the Wrist During Standard Movements and Daily Activities
This project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras.
A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as during activities of daily living. The wrist joint angles measured with both systems will be compared.
Read the detailed description
The accepted laboratory gold standards for human motion analysis are too over-elaborated for clinical use. The DyCare® Lynx system is user-friendly and has been proven reliable for motion evaluation of different joints, but not yet for the wrist.
Therefore, this project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras. DyCare® Lynx is based on two inertial sensors (DyTrack) capable of objectively measuring three dimensional joint movements in real time. Each inertial sensor includes an accelerometer, gyroscope and magnetometer and captures up to 1'000 samples per second. DyCare® Lynx is certified for measurements on the human musculoskeletal apparatus (EN ISO 13485:2003 Certificate No. 15185 - M), is CE marked and will only be applied to each participant for a few minutes during the measurements. The control measurements will be conducted using a Vicon® motion capture system in the Motion Analysis Laboratory of the Department of Plastic Surgery and Hand Surgery of the University Hospital of Zurich. The Vicon® system is equipped with 11 infrared cameras. The system is made for 'Life science application' and is approved as CE medical device. A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as during activities of daily living. The wrist joint angles measured with both systems will be compared, therefore limits of agreement, maximum difference and root mean squared difference will be calculated to quantify the deviation between methods. The standard error of measurements will be calculated to determine repeatability of the systems.
- Conditions
- Healthy Volunteers
- Being tested
- 3D Motion analysis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
3D Motion analysisDevice
Motion analysis using DyCare® Lynx system with inertial based sensors as well as an optoelectronic motion analysis system based on infrared cameras (11x Vicon infrared high speed cameras)
| Study group | Role | What they receive |
|---|---|---|
| healthy Volunteers | Adult (>18y) healthy volunteers without previous injuries or pathologies of the hand and upper extremity Receives: Device: 3D Motion analysis |
What is being measured
The primary outcome is the main question the study is designed to answer.
Active wrist movement at standard movements
Ten healthy subjects will be recorded (3D motion analysis) while performing flexion-extension and radial-ulnar deviation movements of their right wrist using inertial sensors and skin markers
Measured: October 2019
Secondary outcomes (3)
Active Wrist movement during activities of daily living.
Ten healthy subjects will be recorded (3D motion analysis) while performing during ADLs: opening a jar, opening a lid pot, turning a key, dart-throwing.
Measured: January 2020-August 2021
Comfort of the wearable Sensors
questionnaire looking into six dimensions of comfort as proposed by Knight and Baber (Knight, J.F.; Baber, C. A tool to assess the comfort of wearable computers. Human Factors 2005, 47, 77-91, doi:10.1518/0018720053653875.
Measured: October 2019
Time Consumption of measurements using DyCare® Lynx
Minutes necessary to attach the sensors to the patients and to record the movements.
Measured: October 2019
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Feb 2021
- Study start1 Mar 2018
- Primary completion28 Mar 2019
- Study completion31 Dec 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Healthy VolunteersStudies of the same condition, open and under way.
- More trials run by University of ZurichThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Cross-sectional
- Enrolment
- 10 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Zurich
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Maurizio Calcagni, PD Dr. med, Principal investigator, University of Zurich
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04773535
- Sponsor's protocol ID
- BASEC 2018-00457
- Status last verified
- Feb 2021
- First submitted
- 19 Nov 2020
- Last updated
- 26 Feb 2021
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 26 Feb 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Validation of the DyCare® Lynx System for Motion Analysis of the Wrist During Standard Movements and Daily Activities
- ClinicalTrials.gov ID
- NCT04773535
- Acronym / sponsor ID
- BASEC 2018-00457
- Conditions
- Healthy Volunteers
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 10 participants (actual)
- Lead sponsor
- University of ZurichUniversity, hospital or other
- Study start
- 1 Mar 2018 (actual)
- Primary completion
- 28 Mar 2019 (actual)
- Study completion
- 31 Dec 2019 (actual)
- First posted
- 26 Feb 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras.
A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as during activities of daily living. The wrist joint angles measured with both systems will be compared.
Detailed description
The accepted laboratory gold standards for human motion analysis are too over-elaborated for clinical use. The DyCare® Lynx system is user-friendly and has been proven reliable for motion evaluation of different joints, but not yet for the wrist.
Therefore, this project is set to compare the wrist joint movement measurements of the DyCare® Lynx System with optoelectronic motion analysis using a marker system and infrared cameras. DyCare® Lynx is based on two inertial sensors (DyTrack) capable of objectively measuring three dimensional joint movements in real time. Each inertial sensor includes an accelerometer, gyroscope and magnetometer and captures up to 1'000 samples per second. DyCare® Lynx is certified for measurements on the human musculoskeletal apparatus (EN ISO 13485:2003 Certificate No. 15185 - M), is CE marked and will only be applied to each participant for a few minutes during the measurements. The control measurements will be conducted using a Vicon® motion capture system in the Motion Analysis Laboratory of the Department of Plastic Surgery and Hand Surgery of the University Hospital of Zurich. The Vicon® system is equipped with 11 infrared cameras. The system is made for 'Life science application' and is approved as CE medical device. A total of 10 healthy test persons will be subjected to both the DyCare® Lynx and the Vicon® measurements during standard movements as well as during activities of daily living. The wrist joint angles measured with both systems will be compared, therefore limits of agreement, maximum difference and root mean squared difference will be calculated to quantify the deviation between methods. The standard error of measurements will be calculated to determine repeatability of the systems.
Study design
- Observational model
- Cohort
- Time perspective
- Cross-sectional
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| healthy Volunteers | – | Device: 3D Motion analysisAdult (>18y) healthy volunteers without previous injuries or pathologies of the hand and upper extremity |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- 10 healthy volunteers
Key inclusion criteria (3 listed)
- 10 test persons with healthy right-dominant hands
- Test Persons older than 18 Years
- Test persons willing and able to give written informed consent to participate in the study
Key exclusion criteria (5 listed)
- Inflammatory disease (e.g. rheumatoid arthritis)
- German language barrier to understand instructions
- Any disease process that would preclude accurate evaluation (e.g. neuromuscular, psychiatric or metabolic disorder)
- Legal incompetence
- Participation in any other medical device or medicinal product study within the previous months that could influence the results of the present study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| 3D Motion analysisMotion analysis using DyCare® Lynx system with inertial based sensors as well as an optoelectronic motion analysis system based on infrared cameras (11x Vicon infrared high speed cameras) | Device | healthy Volunteers |
Primary outcome
Active wrist movement at standard movements
Time frame: October 2019
Ten healthy subjects will be recorded (3D motion analysis) while performing flexion-extension and radial-ulnar deviation movements of their right wrist using inertial sensors and skin markers
3 secondary outcomes
Active Wrist movement during activities of daily living.
Time frame: January 2020-August 2021
Comfort of the wearable Sensors
Time frame: October 2019
Time Consumption of measurements using DyCare® Lynx
Time frame: October 2019
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 26 Feb 2021.
- Individual participant dataSharing planned: Undecided
Related trials for Healthy Volunteers
Not yet recruiting
Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)
Healthy Volunteers - Male and Female
RecruitingPhase 1
First-in-Human Trial to Assess REGN20423 in Healthy Adult Participants and Adult Participants With Atopic Dermatitis
Healthy Volunteer, Atopic Dermatitis
Not yet recruitingObservational study
Establishment of Biobank of Nasal Epithelium Samples From Healthy Volunteers
Healthy
RecruitingObservational study
Improved Methods of Cell Selection for Bone Marrow Transplant Alternatives
Graft-Versus-Host Disease, Graft-versus-leukemia
Not yet recruitingObservational study
Screening Protocol
Pain
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Maurizio Calcagni, PD Dr. med principal investigator
University of Zurich
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Healthy Volunteers, run by University of Zurich at 1 site in Switzerland.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 26 Feb 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Active wrist movement at standard movements (time frame: October 2019). It is what the study was designed to measure, not a finding.