Frequent Cuff Inflations May Disrupt the Accuracy of 24-hour Ambulatory Blood Pressure Monitoring

An observational study of Hypertension, run by University of Aarhus at 1 site in Denmark.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

24-hour ambulatory blood pressure monitoring (ABPM) is superior to office blood pressure (BP) for assessing cardiovascular risk. On the other hand, repeated cuff inflations during ABPM can cause discomfort and reduced quality of sleep. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Hypertension
What is being tested?
Ambulatory Blood Pressure Monitoring, frequent/non-frequent and Ambulatory Blood Pressure Monitoring, non-frequent/frequent
How many people
171 participants
Where
1 siteDenmark
Study dates
2 Mar 2021to 28 Jun 2022
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: All patients, either referred or existing patients, who has to undergo a 24-hour ambulatory blood pressure monitoring

Who may be able to join

  • Patients either has to be referred from primary care to the Clinic of Hypertension at Aarhus University hospital, or already being treated at the clinic. Both groups has to be scheduled for a 24-hour ambulatory blood pressure monitoring.

Who cannot join

  • Below 18 years of age
  • Have atrial fibrillation
  • Have routine nightshift work
  • Is pregnant
  • Is physically inable to have the cuff applied correctly (too large arm circumference)
  • Known insomnia or other sleeping disorders
  • Change in blood pressure medication within 14 days before inclusion

Trial locations and contacts

1 site in 1 country.

Denmark1 site
  • Hypertension Clinic, Aarhus University Hospital

    Aarhus, 8200

Other trials in Denmark

About this study

24-hour ambulatory blood pressure monitoring (ABPM) is superior to office blood pressure (BP) for assessing cardiovascular risk. On the other hand, repeated cuff inflations during ABPM can cause discomfort and reduced quality of sleep. A high frequency of measurement during ABPM might result in erroneously high BP measurement, incorrect hypertension diagnoses, unnecessary treatment or just overtreatment with antihypertensive medication and potentially serious side effects.

The purpose of this study is to investigate whether the frequency of measurements during ABPM impacts the measured BP during ABPM.

Patients will be recruited from the Clinic of Hypertension at Aarhus University Hospital, Denmark. The study will be conducted as a randomized controlled crossover study. Participants will undergo two 24-hour ABPMs: One with a low frequency of measurement, 1-time per hour during the day and 1-time per hour during the night, and one with a high frequency, 3-times/hour during the day, and 2-times/hour at night. The primary endpoint will be the difference in 24-hour mean systolic BP between the high- and low frequency measurement ABPM.

Read the detailed description

Aim:

The purpose of this study is to evaluate if 24-hour ABPM with frequent BP measurements (intervals of 20 minutes during daytime and 30 minutes during nighttime) result in erroneously elevated BP in hypertensive patients compared with non-frequent BP readings (measurement intervals of 60 minutes both day and night).

Population:

The study population will comprise all patients referred to and attending the Clinic of Hypertension, AUH, who are scheduled to undergo ABPM. At referral to the Clinic of Hypertension, AUH, patients will be contacted with an electronic or analog letter, informing them about the study and inviting them to participate. Patients who already are being treated at the Clinic of Hypertension, will be invited at an appointment in the clinic. Patients will be excluded from the study if they have atrial fibrillation, nighttime work, insomnia or sleeping disorders, and are not physically able to undergo an ABPM (e.g. too big arm circumference to fit the cuff).

Methods:

This will be a randomized controlled crossover study (figure 2). At arrival patients will be fitted with the device, a SPACELABS 90217 by a nurse. The nurse will conduct an office blood pressure measurement, in accordance with ESH guidelines to be sure the device is working, and for later comparison. Patients will have their first ABPM conducted with either frequent or non-frequent ABPM measurement protocol as described above, randomized 1:1. Patients will be instructed to remove their device after 24 hours of measurement and have an appointment to return the device between 2-7 days. At least two days between measurements ensure a sufficient washout period. The maximum of 7 days before second measurement makes sure the patient's appointment with a doctor at the clinic will not be delayed. When returning the device, patients will have the same device mounted again, measuring with the frequency not assigned at the initial randomization. Participants will be instructed to repeat the same procedures regarding the device and to, as far as possible, conduct the same daily activities on the second day of measurement as during the first day of measurement. Patients will not have any alterations in blood pressure medication between the two measuring days. After each ABPM, patients will answer a routine questionnaire from the clinic about sleep, discomfort, pain, and the degree to which the device caused interference with daily activities and/or disturbance of sleep. Since the questionnaire is standard procedure at the clinic, we will be able to compare characteristics between the group who are not interested in joining the study and patients do participate. In this way the investigators can ensure no unknown selection bias occurs. Both ABPM will be used by the clinician at the appointment in the clinic.

Sample size:

In a pilot study conducted at the Clinic of Hypertension, AUH, the investigators found a mean difference of 7 mmHg (Standard deviation = 13,76) between a 20-minute interval and a 1-hour interval between measurements, respectively. Using a sample size calculation, for crossover design with quantitative measurement, a two-sided significance level of 0.025 and a power of 0.9, and a minimal clinical difference of 10mmHg, we calculate a minimum sample size of 38 patients. It is estimated only 25% of patients with this difference will be in intermediate hypertension group as studied in the previous pilot study, which is why 152 patients wil be included.

Conditions
Hypertension
Being tested
Ambulatory Blood Pressure Monitoring, frequent/non-frequent, Ambulatory Blood Pressure Monitoring, non-frequent/frequent
Keywords
Ambulatory Blood Pressure Monitoring, ABPM
Medical subject headings
Hypertension

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Ambulatory Blood Pressure Monitoring, frequent/non-frequentDiagnostic test

    Patient will have a Spacelabs 90217 attached. This device can automatically measure the blood pressure over 24 hours. Patients will have their blood pressure measured first with a frequent interval, and then a non-frequent interval.

  • Ambulatory Blood Pressure Monitoring, non-frequent/frequentDiagnostic test

    Patient will have a Spacelabs 90217 attached. This device can automatically measure the blood pressure over 24 hours. Patients will have their blood pressure measured first with a non-frequent interval, and then a frequent interval.

Study groups in NCT04726761
Study groupRoleWhat they receive
Frequent/Non-frequentPatients randomized to this order will first have an ABPM conducted with the frequent measuring intervals (3 times an hour during day and 2 times an hour at night) and then a few days later have another ABPM conducted with the non-frequent measuring interval (1 time an hour during all 24 hours)
Receives: Diagnostic Test: Ambulatory Blood Pressure Monitoring, frequent/non-frequent
Non-frequent/frequentPatients randomized to this order will first have an ABPM conducted with the non-frequent measuring interval (1 time an hour during all 24 hours) and then a few days later have another ABPM conducted with the frequent measuring intervals (3 times an hour during day and 2 times an hour at night)
Receives: Diagnostic Test: Ambulatory Blood Pressure Monitoring, non-frequent/frequent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The difference in mean systolic blood pressure (SBP) between 24-hour ABPM with frequent and non-frequent measurement intervals

    The systolic blood pressure is one of the most important predictors of a patient's risk of cardiovascular disease that can be measured with ABPM.

    Measured: One week

Secondary outcomes (3)
  1. The difference in mean diastolic blood pressure (DBP) between 24-hour ABPM with frequent and non-frequent measurement intervals.

    Diastolic blood pressure is an important predictor of a patient´s risk of cardiovascular disease that can be measured with ABPM.

    Measured: One week

  2. The self-reported pain/discomfort, interference in daily life, and disturbance of sleep during frequent and non-frequent measurement ABPM

    Self-reported data from a questionnaire, to see if there is a correlation between these factors and a possible difference in measured blood pressure.

    Measured: One week

  3. The difference in average real variability (ARV), dipping status and morning surge during frequent and non-frequent measurement ABPM.

    These are less common but also important factors in regards of a patients blood pressure profile, used to asses a patient's risk of cardiovascular disease.

    Measured: One week

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Jan 2021
  2. Study start2 Mar 2021
  3. Primary completion31 Jan 2022
  4. Study completion28 Jun 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
171 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04726761
Sponsor's protocol ID
1337
Status last verified
Jan 2021
First submitted
19 Jan 2021
Last updated
30 Jun 2022
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Hypertension, run by University of Aarhus at 1 site in Denmark.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Jun 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The difference in mean systolic blood pressure (SBP) between 24-hour ABPM with frequent and non-frequent measurement intervals (time frame: One week). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jun 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in