Obstructed Biliary and Pancreatic DuctRegistryNCT04708288
To Evaluate the Safety and Clinical Performance of the ARCHIMEDES Biodegradable Biliary and Pancreatic Stent
An observational study of Obstructed Biliary and Pancreatic Duct, run by QualiMed Innovative Medizinprodukte GmbH at 11 sites in 8 countries.
Trial summary
Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Obstructed Biliary and Pancreatic Duct
- What is being tested?
- ARCHIMEDES Biodegradable Biliary and Pancreatic Stent
- Type of treatment
- Medical device
- How many people
- 198 participants
- Where
- 11 sitesin 8 countries
- Study dates
- 3 Oct 2020to 31 Dec 2027
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients that will respect the inlcusion criteria will be enrolled in the study.
Who may be able to join
- Patient eligible for implantation of a pancreatic or billiary stent prior to participate in the study and according to current guidelines
- Patient has provided a signed and dated informed consent (according to the laws and regualtions of the country in which the observational study is conducted)
Who cannot join
- Age < 18 y
- Inability to understand the purpose of the study or refusal to cooperate
- Not available for routine follow-up visits
- Pregnancy
- Currently participating in a confounding trial before reaching first endpoint.
Trial locations and contacts
11 sites in 8 countries. Contact the study team or a site near you to ask about taking part.
11 sites in 8 countries
Italy4 sites
- Completed
AUSL Romagna Ospedale Morgagni - Pierantoni
Forlì, 47121
- Active, not recruiting
Gastroenterology and Digestive Endoscopy Unit Fondazione I.R.C.C.S. Policlinico San Matteo
Pavia, 27100
- Active, not recruiting
UCBM - Campus Bio-Medico University
Roma, 00128
- Active, not recruiting
Endoscopy Unit, Humanitas Research Hospital
Rozzano, Milano, 20089
France1 site
- Active, not recruiting
Hôpital Européen Georges-Pompidou HEGP Service d'Hépato-gastro-entérologie et endoscopies digestives
Paris, 75015
Germany1 site, 1 recruiting
- Recruiting
Evangelisches Krankenhaus Düsseldorf
Düsseldorf, 40217
Biljana Dimitrijevic, PhD, +49 (0)211919483 601, Biljana.Dimitrijevic@evk-duesseldorf.de
Carina Friesl, carina.friesl@evk-duesseldorf.de
Slovenia1 site, 1 recruiting
- Recruiting
University Medical Center Ljubljana
Ljubljana, 1000
Karin Pulevic, VS, +38615228515, karin.pulevic@kclj.si
Dr. Martina Jaklič, MD, +38615222037, martina.jaklic@kclj.si
Spain1 site, 1 recruiting
- Recruiting
Hospital Universitario de Salamanca
Salamanca, 37007
Solorzano Garcia Ignacio, +34 679441022 ext. 55400, isolorzano.ibsal@saludcastillayleon.es
Dr. Alberto Álvarez Delgado, MD, PhD
About this study
Official title: A PROSPECTIVE, MULTI-CENTER, SINGLE-ARM, POST MARKET OBSERVATIONAL STUDY TO EVALUATE THE SAFETY AND CLINICAL PERFORMANCE OF THE ARCHIMEDES BIODEGRADABLE BILIARY AND PANCREATIC STENT
Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Stents are typically made from polymeric materials including Polylactic Acid (PLA), Polyglycolide (PGA), Polydioxanone (PDO), Polyethyleneglycol (PEG), Polycaprolactone (PCL), etc., which have been cleared or approved by the FDA and CE-marked as drug carriers, sutures, and bone fixatives. The material is degraded by hydrolysis in, e.g., lactic acid, which is removed from the body by normal metabolic pathways. In the field of gastroenterology, these stents were first introduced in patients with an esophageal stenosis with encouraging results, although esophageal hyperplasia was a frequently encountered complication.
For biliary applications, biodegradable stents have been evaluated in several in-vitro and animal studies that demonstrated that the stents were safe and well tolerated. These stents provided an adequate radial force and resulted in complete stricture resolution within several months. The stents did not show any signs of biliary hyperplasia or integration in the epithelium. Moreover, they seem to have a self-clearing effect on attached biofilm as the outer layer sloughs during the degradation process similarly to the exfoliation of human skin. Also, the stent could be removed from the bile duct, thus offering the possibility of extraction if necessary at various times after implantation.
Read more
In 2010, Petryl was the first to use a biodegradable stent in the human bile duct. A stent was successfully placed using percutaneous transhepatic cholangiograpy in two patients with a postsurgical intrahepatic biliary stricture. Transient cholangitis was the only complication encountered and during the two years of follow-up, the bile duct remained patent.
Later, Mauri et al. presented in 2013 and 2016 results of a 107 patient study on a polydioxanone biodegradable biliary stent. The results have been published in the Journal of the European Society of Radiology. The authors concluded that percutaneous placement of a biodegradable biliary stent is a feasible and safe strategy to treat benign biliary strictures refractory to standard bilioplasty, with promising results in the mid-term period.
Prior to this study, the ARCHIMEDES device was assessed in the ARCHIMEDES Investigational study which has completed enrolment with 53 patients included, and the results are not yet published. In this study approximately half the stents were deployed in the bile duct (53%) and half in the pancreatic duct. All 53 patients have either completed, exited, or no longer have the study device. No patient remains in the study with a stent in place during the time of the last patient follow-ups. The study concluded without any device-related SAE. Bilirubin was reduced by 25.6%, which exceeded the >20% clinical success criterion, quality of life score improved from 3.7 to 7.9, procedural success was rated 1.4 (good to excellent), and technical success was achieved in all 53 patients.
Data from the ARCHIMEDES Investigational study was used for CE Mark approval, which was obtained in June 2018.
- Conditions
- Obstructed Biliary and Pancreatic Duct
- Being tested
- ARCHIMEDES Biodegradable Biliary and Pancreatic Stent
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
ARCHIMEDES Biodegradable Biliary and Pancreatic StentDevice
Patients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine clinical practice
| Study group | Role | What they receive |
|---|---|---|
| Patients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine practice | Participants receiving commercially available ARCHIMEDES Biodegradable Biliary and Pancreatic as part of standard care. Safety outcomes are collected for post-marketing surveillance Receives: Device: ARCHIMEDES Biodegradable Biliary and Pancreatic Stent |
What is being measured
The primary outcome is the main question the study is designed to answer.
Primary Safety endpoint
Proportion of subjects experiencing procedure- or device-related complications within 30 days including Post-ERCP pancreatitis, Bleeding, Perforation (biliary/pancreatic/duodenal), Stent misplacement, Stent migration, Biliary occlusion, Cholangitis, Severe pain, All-cause death Within 30 days of the index procedure
Measured: From enrollment to the end of treatment, as per the standard of care.
Secondary outcomes (1)
Secondary endpoints are defined as:
Clinical success: patency rate as defined by the rate of freedom of stent replacements at follow-up time points defined by investigators definition of SOC (standard of care) or until planned bridge surgery (defined as no need of stent replacement).
Technical success: Accurate stent deployment across the target stricture as evaluated by fluoroscopy and endoscopy.
Procedural success will be quantified (using a dedicated score system, Excellence=1, Good=2, Fair=3, Poor=4) by the endoscopist post procedure using the following components:
- Stent loadability
- Trackability over Guide Wire
- Pushibility with push catheter
- Visualization by fluoroscopy
- Stent repositiong when required
- Deployment accuracy
Measured: Technical and Procedural success on the Procedure day and clinical success as per the Standard of Care
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Jan 2021
- Study start3 Oct 2020
- Primary completion30 Jun 2027 (estimated)
- Study completion31 Dec 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Obstructed Biliary and Pancreatic DuctStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 198 participants (estimated)
Sponsor and investigators
- Lead sponsor
- QualiMed Innovative Medizinprodukte GmbH
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04708288
- Sponsor's protocol ID
- QM-NI-ABS-034
- Acronym
- Registry
- Status last verified
- Oct 2026
- First submitted
- 8 Jan 2021
- Last updated
- 5 Oct 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 5 Oct 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A PROSPECTIVE, MULTI-CENTER, SINGLE-ARM, POST MARKET OBSERVATIONAL STUDY TO EVALUATE THE SAFETY AND CLINICAL PERFORMANCE OF THE ARCHIMEDES BIODEGRADABLE BILIARY AND PANCREATIC STENT
- ClinicalTrials.gov ID
- NCT04708288
- Acronym / sponsor ID
- Registry / QM-NI-ABS-034
- Conditions
- Obstructed Biliary and Pancreatic Duct
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 198 participants (estimated)
- Lead sponsor
- QualiMed Innovative Medizinprodukte GmbHIndustry (pharma, biotech, devices)
- Study start
- 3 Oct 2020 (actual)
- Primary completion
- 30 Jun 2027 (estimated)
- Study completion
- 31 Dec 2027 (estimated)
- First posted
- 13 Jan 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Stents are typically made from polymeric materials including Polylactic Acid (PLA), Polyglycolide (PGA), Polydioxanone (PDO), Polyethyleneglycol (PEG), Polycaprolactone (PCL), etc., which have been cleared or approved by the FDA and CE-marked as drug carriers, sutures, and bone fixatives. The material is degraded by hydrolysis in, e.g., lactic acid, which is removed from the body by normal metabolic pathways. In the field of gastroenterology, these stents were first introduced in patients with an esophageal stenosis with encouraging results, although esophageal hyperplasia was a frequently encountered complication.
For biliary applications, biodegradable stents have been evaluated in several in-vitro and animal studies that demonstrated that the stents were safe and well tolerated. These stents provided an adequate radial force and resulted in complete stricture resolution within several months. The stents did not show any signs of biliary hyperplasia or integration in the epithelium. Moreover, they seem to have a self-clearing effect on attached biofilm as the outer layer sloughs during the degradation process similarly to the exfoliation of human skin. Also, the stent could be removed from the bile duct, thus offering the possibility of extraction if necessary at various times after implantation.
In 2010, Petryl was the first to use a biodegradable stent in the human bile duct. A stent was successfully placed using percutaneous transhepatic cholangiograpy in two patients with a postsurgical intrahepatic biliary stricture. Transient cholangitis was the only complication encountered and during the two years of follow-up, the bile duct remained patent.
Later, Mauri et al. presented in 2013 and 2016 results of a 107 patient study on a polydioxanone biodegradable biliary stent. The results have been published in the Journal of the European Society of Radiology. The authors concluded that percutaneous placement of a biodegradable biliary stent is a feasible and safe strategy to treat benign biliary strictures refractory to standard bilioplasty, with promising results in the mid-term period.
Prior to this study, the ARCHIMEDES device was assessed in the ARCHIMEDES Investigational study which has completed enrolment with 53 patients included, and the results are not yet published. In this study approximately half the stents were deployed in the bile duct (53%) and half in the pancreatic duct. All 53 patients have either completed, exited, or no longer have the study device. No patient remains in the study with a stent in place during the time of the last patient follow-ups. The study concluded without any device-related SAE. Bilirubin was reduced by 25.6%, which exceeded the >20% clinical success criterion, quality of life score improved from 3.7 to 7.9, procedural success was rated 1.4 (good to excellent), and technical success was achieved in all 53 patients.
Data from the ARCHIMEDES Investigational study was used for CE Mark approval, which was obtained in June 2018.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Patients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine practice | – | Device: ARCHIMEDES Biodegradable Biliary and Pancreatic StentParticipants receiving commercially available ARCHIMEDES Biodegradable Biliary and Pancreatic as part of standard care. Safety outcomes are collected for post-marketing surveillance |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients that will respect the inlcusion criteria will be enrolled in the study.
Key inclusion criteria (2 listed)
- Patient eligible for implantation of a pancreatic or billiary stent prior to participate in the study and according to current guidelines
- Patient has provided a signed and dated informed consent (according to the laws and regualtions of the country in which the observational study is conducted)
Key exclusion criteria (5 listed)
- Age < 18 y
- Inability to understand the purpose of the study or refusal to cooperate
- Not available for routine follow-up visits
- Pregnancy
- Currently participating in a confounding trial before reaching first endpoint.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| ARCHIMEDES Biodegradable Biliary and Pancreatic StentPatients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine clinical practice | Device | Patients will treated with ARCHIMEDES Biodegradable Biliary and Pancreatic Stent in routine practice |
Primary outcome
Primary Safety endpoint
Time frame: From enrollment to the end of treatment, as per the standard of care.
Proportion of subjects experiencing procedure- or device-related complications within 30 days including Post-ERCP pancreatitis, Bleeding, Perforation (biliary/pancreatic/duodenal), Stent misplacement, Stent migration, Biliary occlusion, Cholangitis, Severe pain, All-cause death Within 30 days of the index procedure
1 secondary outcome
Secondary endpoints are defined as:
Time frame: Technical and Procedural success on the Procedure day and clinical success as per the Standard of Care
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Oct 2026.
- Individual participant dataSharing planned: No
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
11 sites in 8 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Obstructed Biliary and Pancreatic Duct, run by QualiMed Innovative Medizinprodukte GmbH at 11 sites in 8 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 5 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 11 sites in Italy, Finland, France, Germany, Israel and 3 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact NIta Gondaliya (+49 1716578285, ngondaliya@q3medical.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Primary Safety endpoint (time frame: From enrollment to the end of treatment, as per the standard of care.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Oct 2026.