Aortic Valve StenosisNAUTILUSNCT04704258
NAUTILUS CE-mark Trial of the FLOWer Cerebral Embolic Protection Device
A study testing TAVI (Transcatheter Aortic Valve Implant) and FLOWer Embolic Protection System in people with Aortic Valve Stenosis and Intracranial Embolism and Thrombosis, run by AorticLab Srl at 8 sites in 2 countries.
Trial summary
The purpose of this clinical study is to assess the safety, performance, and treatment effect of the use of the AorticLab FLOWer System, in preventing cerebral thromboembolic complications in patients with indication for a TAVI (Transcatheter Aortic Valve Implant). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Valve Stenosis, Intracranial Embolism and Thrombosis
- What is being tested?
- TAVI (Transcatheter Aortic Valve Implant) and FLOWer Embolic Protection System
- Type of treatment
- Medical device, Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 100 participants
- Where
- 8 sitesin 2 countries
- Study dates
- 3 May 2021to 6 Jun 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subjects of age ≥ 18 years
- Subject is scheduled to undergo transfemoral aortic valve implant (TAVI) procedure on a stenotic native aortic valve and is qualified based on pre-operative CT-scan examination (trans-thoracic echocardiogram (TTE) can be used as confirmatory assessment)
- Subject anatomy with Ilio-femoral artery segment compatible with a 12 F device catheter size
- The subject and the treating physician agree that the subject will undergo the scheduled pre-procedural testing and return for all required post-procedure follow-up visits
- The subject, or legally authorized representative, has been informed of the nature of the study, agrees to its provisions and has provided written informed consent, approved by the appropriate Medical Ethics Committee (EC) or Institutional Review Board (IRB)
Who cannot join
- Clinical exclusion criteria (preoperative screening)
- Subjects with hypercoagulable state that cannot be corrected by additional periprocedural heparin
- Subjects with contraindication to cerebral MRI
- Subjects with a history of a stroke or transient ischemic attack within the prior 6 months
- Subjects with known diagnosis of acute myocardial infarction (AMI) within 30 days preceding the index procedure
- Renal insufficiency (creatinine > 3.0 mg/dL or Glomerular Filtration Rate GFR < 30) and/or renal replacement therapy at the time of screening
Show all 24Show fewer
- Subjects with a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated, patients who will refuse transfusion, or patients with an active peptic ulcer or history of upper gastrointestinal (GI) bleeding within the prior 3 months
- Subjects with known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/ticlopidine, nitinol, stainless steel alloy, and/or contrast sensitivity that cannot be adequately pre-medicated
- Subject is currently participating in another drug or device clinical study or has other medical illnesses that may cause the subject to be non-compliant with the protocol or confound the data interpretation
- Subjects with a previously implanted prosthetic aortic valve (i.e., planned valve-in-valve with a TAVI)
- Subject requires an emergent procedure
- Subject has active major psychiatric disease
- Subjects with neurodegenerative or other progressive neurological disease or history of significant head trauma followed by persistent neurologic defaults or known structural brain abnormalities
- Subject has an ejection fraction of 30% or less
- Subjects with active endocarditis or other systemic infection
- Subjects undergoing therapeutic thrombolysis
- Subject is pregnant or lactating. Pregnancy confirmed by positive urine or serum test
- Computerized Tomographic exclusion criteria (preoperative screening)
- Subjects with documented friable or mobile atherosclerotic plaque in the aortic arch
- Subjects with echocardiographic evidence of aortic mass, thrombus or vegetation
- Subjects with a diameter of the ascending aorta < 25 and > 39 mm at baseline CT (measured 10 mm upstream of the first vessel of the brachiocephalic trunk)
- Subjects undergoing transcatheter aortic valve implantation (TAVI) via the trans-axillary, trans-subclavian, or trans-aortic route
- Subjects with severe peripheral arterial, abdominal aortic, or thoracic aortic disease that precludes delivery of sheath vascular access
- Subjects in whom the aortic arch is heavily calcified, severely atheromatous, or severely tortuous
Trial locations and contacts
8 sites in 2 countries.
8 sites in 2 countries
Italy6 sites
IRCCS Ospedale San Raffaele
Milan, MI, 20132
Centro Cardiologico Monzino IRCCS
Milan, 20138
Casa di Cura Policlinico di Monza
Monza, MB, 20900
Clinica San Gaudenzio
Novara, 28100
San Carlo Azienda Ospedaliera Regionale
Potenza, PZ, 85100
IRCCS Policlinico San Donato
San Donato Milanese, MI, 20097
Belgium2 sites
HartCentrum, Ziekenhuis Netwerk Antwerpen (ZNA) Middelheim
Antwerp, 2020
CUB Hôpital Erasme (ULB)
Brussels, 1070
About this study
Official title: Clinical Study of a Novel Transcatheter Anti-embolic Filter (FLOWer) for Cerebral Protection During Aortic Valve Interventions
The purpose of this clinical study is to assess the safety, performance, and treatment effect of the use of the AorticLab FLOWer System, in preventing cerebral thromboembolic complications in patients with indication for a TAVI (Transcatheter Aortic Valve Implant).
Read the detailed description
A single arm, prospective, multicenter non-randomized clinical study of the AorticLab FLOWer System to prevent embolic complications during transcatheter aortic valve procedures.
- Being tested
- TAVI (Transcatheter Aortic Valve Implant), FLOWer Embolic Protection System
- Keywords
- TAVI, Transcatheter Anti-embolic Filter, Cerebral Embolic Protection, Embolic Protection Device, Debris, Embolic material
- Medical subject headings
- Aortic Valve Stenosis, Intracranial Embolism and Thrombosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
TAVI (Transcatheter Aortic Valve Implant)Procedure or surgery
Placement of a filter to capture and remove emboli or debris detached during any transcatheter heart procedures
FLOWer Embolic Protection SystemDevice
Also called transcatheter embolic protection for TAVI procedures
FLOWer Embolic Protection System
| Study group | Role | What they receive |
|---|---|---|
| TAVI + Embolic protection | Experimental | Subjects with severe native aortic valve stenosis who meet the clinically approved indications for aortic valve interventions such as TAVI Receives: Procedure: TAVI (Transcatheter Aortic Valve Implant); Device: FLOWer Embolic Protection System |
What is being measured
The primary outcome is the main question the study is designed to answer.
FLOWer Device Safety: Rate of Major Adverse Cardiac and Cerebrovascular Events
Primary Safety Endpoint: FLOWer device Safety, rate of Major Adverse Cardiac and Cerebrovascular Events (MACCEs) related to FLOWer device and procedure as adjudicated by a Clinical Event Committee. MACCEs are based on the Valve Academic Research Consortium (VARC- 3) criteria:
- all death;
- all stroke (disabling and non-disabling);
- acute kidney injury (stage 3 at discharge or 72 hours post index procedure, whichever occurs first)
Measured: 30 days
Reduction in total volume of new cerebral lesions in all territories at serial DWMRI
Primary Clinical Benefit Endpoint: Reduction in total volume of new cerebral lesions in all territories at serial DWMRI, compared to historical data in control arm (unprotected) data from previous randomized studies
Measured: Within 2-5 days after procedure vs. baseline
Secondary outcomes (6)
Cumulative occurrence of Serious Clinical Events related to FLOWer device and procedure as adjudicated by a Clinical Event Committee.
Secondary Safety Endpoint: Cumulative occurrence of Serious Clinical Events related to FLOWer device and procedure as adjudicated by a Clinical Event Committee. all-cause mortality including cardiovascular mortality;
- all stroke (disabling and non-disabling);
- bleeding (life-threatening or disabling);
- acute kidney injury (stage 3 at discharge or 72 hours post index procedure, whichever occurs first);
- major device access related vascular complications;
- coronary artery obstruction requiring intervention;
- valve-related dysfunction requiring repeat procedure (balloon aortic valvuloplasty, repeat TAVI, or surgical aortic valve replacement).
Measured: 7 and 30 days
Brain imaging (DW-MRI)
Secondary Clinical Benefit Endpoints: Acute cerebral embolic burden reduction after TAVI, defined as number and volume of new cerebral lesions in all cerebral territories assessed by DW-MRI
Measured: Within 2-5 days after procedure vs. baseline
Neurocognitive
Secondary Clinical Benefit Endpoints: Neurocognitive protection assessed by NIHSS, Montreal Cognitive Assessment, and mRS
Measured: 2-7 days and 30-days vs. baseline
Technical Success
Secondary Performance Endpoints: Technical Success defined as successful placement, insertion and removal of the FLOWer System
Measured: Immediately after procedure
Debris capture
Secondary Performance Endpoints: Debris captured by the FLOWer System with gross and histopathological evaluation including particle size and composition
Measured: Immediately after procedure
FLOWer System Usability
Secondary Performance Endpoints: FLOWer System Usability graded by the Investigator with a 5-point Likert scale
The minimum and the maximum values of the scale are defined as follows:
(1) Unacceptable; (2) Poor; (3) Acceptable; (4) Good; (5) Excellent
Measured: Immediately after procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Jan 2021
- Study start3 May 2021
- Primary completion6 Jun 2023
- Study completion6 Jun 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Aortic Valve StenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 100 participants (actual)
Sponsor and investigators
- Lead sponsor
- AorticLab Srl
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Meditrial Europe Ltd.
- Responsible party
- Sponsor
- Investigators
- Franco Osta, Study chair, AorticLab Srl
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04704258
- Sponsor's protocol ID
- #2020-01 (EU)
- Acronym
- NAUTILUS
- Status last verified
- Feb 2024
- First submitted
- 4 Jan 2021
- Last updated
- 23 Feb 2024
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 23 Feb 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Study of a Novel Transcatheter Anti-embolic Filter (FLOWer) for Cerebral Protection During Aortic Valve Interventions
- ClinicalTrials.gov ID
- NCT04704258
- Acronym / sponsor ID
- NAUTILUS / #2020-01 (EU)
- Keywords
- TAVI, Transcatheter Anti-embolic Filter, Cerebral Embolic Protection, Embolic Protection Device, Debris, Embolic material
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 100 participants (actual)
- Lead sponsor
- AorticLab SrlIndustry (pharma, biotech, devices)
- Collaborators
- Meditrial Europe Ltd.
- Study start
- 3 May 2021 (actual)
- Primary completion
- 6 Jun 2023 (actual)
- Study completion
- 6 Jun 2023 (actual)
- First posted
- 11 Jan 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this clinical study is to assess the safety, performance, and treatment effect of the use of the AorticLab FLOWer System, in preventing cerebral thromboembolic complications in patients with indication for a TAVI (Transcatheter Aortic Valve Implant).
Detailed description
A single arm, prospective, multicenter non-randomized clinical study of the AorticLab FLOWer System to prevent embolic complications during transcatheter aortic valve procedures.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| TAVI + Embolic protection | Experimental | Procedure: TAVI (Transcatheter Aortic Valve Implant), Device: FLOWer Embolic Protection SystemSubjects with severe native aortic valve stenosis who meet the clinically approved indications for aortic valve interventions such as TAVI |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Subjects of age ≥ 18 years
- Subject is scheduled to undergo transfemoral aortic valve implant (TAVI) procedure on a stenotic native aortic valve and is qualified based on pre-operative CT-scan examination (trans-thoracic echocardiogram (TTE) can be used as confirmatory assessment)
- Subject anatomy with Ilio-femoral artery segment compatible with a 12 F device catheter size
- The subject and the treating physician agree that the subject will undergo the scheduled pre-procedural testing and return for all required post-procedure follow-up visits
- The subject, or legally authorized representative, has been informed of the nature of the study, agrees to its provisions and has provided written informed consent, approved by the appropriate Medical Ethics Committee (EC) or Institutional Review Board (IRB)
Key exclusion criteria (24 listed)
- Clinical exclusion criteria (preoperative screening)
- Subjects with hypercoagulable state that cannot be corrected by additional periprocedural heparin
- Subjects with contraindication to cerebral MRI
- Subjects with a history of a stroke or transient ischemic attack within the prior 6 months
- Subjects with known diagnosis of acute myocardial infarction (AMI) within 30 days preceding the index procedure
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| TAVI (Transcatheter Aortic Valve Implant)Placement of a filter to capture and remove emboli or debris detached during any transcatheter heart procedures | Procedure or surgery | TAVI + Embolic protection |
| FLOWer Embolic Protection SystemAlso: transcatheter embolic protection for TAVI proceduresFLOWer Embolic Protection System | Device | TAVI + Embolic protection |
Primary outcome
FLOWer Device Safety: Rate of Major Adverse Cardiac and Cerebrovascular Events
Time frame: 30 days
Primary Safety Endpoint: FLOWer device Safety, rate of Major Adverse Cardiac and Cerebrovascular Events (MACCEs) related to FLOWer device and procedure as adjudicated by a Clinical Event Committee. MACCEs are based on the Valve Academic Research Consortium (VARC- 3) criteria: * all death; * all stroke (disabling and non-disabling); * acute kidney injury (stage 3 at discharge or 72 hours post index procedure, whichever occurs first)
Reduction in total volume of new cerebral lesions in all territories at serial DWMRI
Time frame: Within 2-5 days after procedure vs. baseline
Primary Clinical Benefit Endpoint: Reduction in total volume of new cerebral lesions in all territories at serial DWMRI, compared to historical data in control arm (unprotected) data from previous randomized studies
6 secondary outcomes
Cumulative occurrence of Serious Clinical Events related to FLOWer device and procedure as adjudicated by a Clinical Event Committee.
Time frame: 7 and 30 days
Brain imaging (DW-MRI)
Time frame: Within 2-5 days after procedure vs. baseline
Neurocognitive
Time frame: 2-7 days and 30-days vs. baseline
Technical Success
Time frame: Immediately after procedure
Debris capture
Time frame: Immediately after procedure
FLOWer System Usability
Time frame: Immediately after procedure
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 23 Feb 2024.
- Aorticlab Sponsor websiteLink provided by the sponsor.
- Meditrial Clinical Research OrganizationLink provided by the sponsor.
Related trials for Aortic Valve Stenosis
Recruiting
Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
Aortic Stenosis Treated With TAVI, Aortic Diseases
Not yet recruiting
Human Experimental Models of Pain (HEMP)
Acute Pain
Active, not recruitingObservational study
Intravascular Lithotripsy in High Risk Calcified Iliac Anatomy for Transfemoral TAVR
Iliac Disease, Aortic Valve Stenosis
Not yet recruiting
NHLBI SESAME (SEptal Scoring Along Midline Endocardium) Multi-Center Prospective Study Using Improvised Off-Label Devices
Hypertrophic Cardiomyopathy, Left Ventricular Outflow Obstruction
Recruiting
Exercise and Diet Supplements for Older Patients Undergoing TAVI: the IRON-TAVI Trial
Aortic Stenosis Disease, Aortic Stenosis Symptomatic
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Franco Osta study chair
AorticLab Srl
8 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing TAVI (Transcatheter Aortic Valve Implant) and FLOWer Embolic Protection System in people with Aortic Valve Stenosis and Intracranial Embolism and Thrombosis, run by AorticLab Srl at 8 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 24 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 23 Feb 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 8 sites in Italy, Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
FLOWer Device Safety: Rate of Major Adverse Cardiac and Cerebrovascular Events (time frame: 30 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Feb 2024.