AzTrials
AzTrials

Cardiopulmonary ArrestNCT04690517

Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR Wearing PPE

A study testing tracheal ultrasound in people with Cardiopulmonary Arrest, run by Samsung Medical Center at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

It is very important to ensure the tube placement in patients with cardiac arrest and unrecognized misplacement of endo-tracheal tube can lead to morbidity and mortality. In recent pandemic situations such as COVID-19 (Coronavirus disease-19), the number of cases of cardiopulmonary resuscitation with personal… Read more about this study

Who is it for?
Ages 18 to 100 years
Conditions the study is for
Cardiopulmonary Arrest
What is being tested?
tracheal ultrasound
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
34 participants
Where
1 siteSouth Korea
Study dates
30 Jan 2021to Jul 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 100 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • 1. cardiopulmonary arrest patients receiving emergency intubation and CPR
  • 2. patients judged to need to wear PPE according to the judgement of the clinician

Who cannot join

  • 1. sign for "do not resuscitate (DNR)"
  • 2. patients unable to perform tracheal ultrasound due to trauma of the site
  • 3. patients unable to perform tracheal ultrasound due to oropharynx cancer
  • 4. patients unable to perform tracheal ultrasound due to placement of tracheal cannula
  • 5. patients not used tracheal ultrasound for checking tube placement

Trial locations and contacts

1 site in 1 country.

Hee Yoon, Professor contact

+821099335581

wildhi.yoon@samsung.com

Sooyeon Kang, fellow contact

82-10-3157-4718

syrei3.kang@samsung.com

South Korea1 site, 1 recruiting
  • Samsung Medical Center

    Seoul, 06351

    Hee Yoon, Professor, 82-10-9933-5581, wildhi.yoon@samsung.com

    Sooyeon Kang, fellow, 82-10-3157-4718, syrei3.kang@samsung.com

    Recruiting

Other trials in South Korea

About this study

Official title: Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR (Cardiopulmonary Resuscitation) Wearing PPE (Personnel Protective Equipment): A Prospective Comparative Study

It is very important to ensure the tube placement in patients with cardiac arrest and unrecognized misplacement of endo-tracheal tube can lead to morbidity and mortality. In recent pandemic situations such as COVID-19 (Coronavirus disease-19), the number of cases of cardiopulmonary resuscitation with personal protective equipment (PPE) have increased. In those cases, existing methods such as auscultation and chest uprising have to be limited. Quantitative waveform capnography is recommended as the gold standard for confirming correct endotracheal tube placement in the 2010 American HeartAssociation (AHA) Guidelines for Cardiopulmonary resuscitation (CPR) and Emergency Cardiovascular Care (ECC), but it has some well-known limitations in cardiac arrest patients.

Ultrasonography is a non-invasive, real-time diagnostic tool commonly used during resuscitation. Especially, tracheal ultrasonography can be performed in real-time when the tube is passed through the trachea or esophagus. Previous prospective studies revealed that tracheal ultrasonography could feasibly and rapidly confirm tracheal intubation during emergency intubation.

There have already been several studies comparing the accuracy of tracheal ultrasound and capnography, but there was no study comparing the two tools under the constraints of PPE that is essential in pandemic situations as in this study. This study aimed to determine the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR with PPE.

Read the detailed description

When patients in cardiopulmonary arrest enter a emergency room (ER) or patients staying in a ER have a cardiopulmonary arrest, participants perform intubation and CPR. When it is judged as a high-risk group with a high probability of droplet infection, all participants in resuscitation team should wear personal protective equipment. Tracheal ultrasound and end-tidal carbon dioxide are used to confirm the placement of tube. The gold standard is the direct visualization using laryngoscope. The time it takes to confirm the placement of tube is also measured.

Being tested
tracheal ultrasound
Medical subject headings
Heart Arrest

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • tracheal ultrasoundProcedure or surgery

    When checking tracheal ultrasound, several signs are used in judgements. Direct signs include reverberation artifact and double ring sign. Indirect sign means checking the bilateral lung sliding.

Study groups in NCT04690517
Study groupRoleWhat they receive
Tracheal ultrasoundOtherThe patients in cardiopulmonary arrest should be performed tracheal ultrasound when tube is passed through the trachea or esophagus.
Receives: Procedure: tracheal ultrasound

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy

    The gold standard is direct visualization using laryngoscopy. Tracheal ultrasound is performed regardless of whether it is in real-time or not.

    Measured: during intubation procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Dec 2020
  2. Study start30 Jan 2021
  3. Primary completionFeb 2022 (estimated)
  4. Study completionJul 2022 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
34 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04690517
Sponsor's protocol ID
2020-11-115
Status last verified
Dec 2020
First submitted
21 Dec 2020
Last updated
2 Jun 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Chou HC, Chong KM, Sim SS, Ma MH, Liu SH, Chen NC, Wu MC, Fu CM, Wang CH, Lee CC, Lien WC, Chen SC. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation. Resuscitation. 2013 Dec;84(12):1708-12. doi: 10.1016/j.resuscitation.2013.06.018. Epub 2013 Jul 9.

    PubMed 23851048

Questions about this trial

What is this clinical trial studying?

A study testing tracheal ultrasound in people with Cardiopulmonary Arrest, run by Samsung Medical Center at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 2 Jun 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Hee Yoon, Professor (+821099335581, wildhi.yoon@samsung.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy (time frame: during intubation procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04690517, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Jun 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.