Prostate CancerLPM-012NCT04632251
Evaluation of the SENSEI® Laparoscopic Tethered Gamma Probe for 99mTc-nanocolloid Sentinel Lymph Node Biopsy in Prostate Cancer
A study testing SENSEI® in people with Prostate Cancer, run by Lightpoint Medical Limited at 4 sites in 4 countries.
Trial summary
This study is a prospective, open label, single-arm study to examine the performance and safety of the SENSEI® laparoscopic tethered gamma probe in patients undergoing 99mTc-nanocolloid SLNB for prostate cancer (PCa) during RP and ePLND surgery. Read more about this study
- Who is it for?
- Ages 18 years and older, men only
- Conditions the study is for
- Prostate Cancer
- What is being tested?
- SENSEI®
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 56 participants
- Where
- 4 sitesin 4 countries
- Study dates
- 16 Sep 2020to Aug 2021
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- Men only
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Male subjects who are ≥ 18 years of age with histologically proven prostate cancer; and who have signed an informed consent form prior to any study related activity • Subjects who are scheduled for radical prostatectomy with ePLND.
Who cannot join
- Subjects who have received prior prostate cancer treatment or prior pelvic surgery;
- Subjects who have an existing medical condition that would compromise their participation in the study;
- Subjects with a history of hypersensitivity to 99mTc-nanocolloid or any excipients;
- Subjects who are unable to give voluntary, written informed consent to participate in this study;
- Subjects who are unable to understand this study and are not willing to complete all the study assessments.
Trial locations and contacts
4 sites in 4 countries.
4 sites in 4 countries
Belgium1 site, 1 recruiting
- Not yet recruiting
UZ Leuven
Leuven, 3000
Wouter Evearaets, +3216346930, wouter.everaerts@uzleuven.be
Wouter Evearaets
France1 site, 1 recruiting
- Not yet recruiting
Institute Paoli-Calmettes
Marseille, 13009
Jochen Walz, +33 491 223532, WALZJ@ipc.unicancer.fr
Jochen Walz
Germany1 site, 1 recruiting
- Not yet recruiting
University Hospital Essen
Essen, 45147
Boris Hadaschik, +492017233210, Boris.HadaschikC@.uk-essen.de
Boris Hadaschik
Spain1 site, 1 recruiting
- Recruiting
Hospital del Mar
Barcelona, 08003
Lluis Fumado Ciutat, +34 650 947 553, LFumado@parcdesalutmar.cat
Lluis Fumado Ciutat
About this study
This study is a prospective, open label, single-arm study to examine the performance and safety of the SENSEI® laparoscopic tethered gamma probe in patients undergoing 99mTc-nanocolloid SLNB for prostate cancer (PCa) during RP and ePLND surgery.
Patients scheduled for RP and ePLND using the standard treatment pathways at each centre will have preoperative 99mTc-nanocolloid imaging. RP and ePLND will be conducted as standard of care, with SLNB guided by the SENSEI® laparoscopic tethered gamma probe carried out after RP and prior to ePLND. The first 2 patients per site (N = 10 in total) are considered to be sufficient to enable further familiarisation with the procedure and use of the probe in addition to the usability work and training that the sites did prior to the start of this study. Subsequent patients will be evaluable for the PP population. The primary analysis of diagnostic performance will be performed using the PP population of patients with SLN identified on preoperative imaging
- Conditions
- Prostate Cancer
- Being tested
- SENSEI®
- Medical subject headings
- Prostatic Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
SENSEI®Device
SENSEI® laparoscopic tethered gamma probe is an intra-operative laparoscopic gamma probe system
| Study group | Role | What they receive |
|---|---|---|
| Familiarisation | Other | The first 2 patients per site (N = 10 in total) are considered to be sufficient to enable further familiarisation with the procedure and use of the probe in addition to the usability work and training that the sites did prior to the start of this study. Receives: Device: SENSEI® |
What is being measured
The primary outcome is the main question the study is designed to answer.
Sentinel lymph node (SLN) detection rate with the SENSEI® laparoscopic tethered gamma probe. Detection rate is defined as the percentage of patients with at least one SLN detected intraoperatively.
Measured: Length of study finish - 6 Months
Secondary outcomes (14)
Number of SLNs detected with the SENSEI® laparoscopic tethered gamma probe in comparison to preoperative planar LS and SPECT/CT in centres with a SPECT/CT scanner.
Measured: Length of study finish - 6 Months
Diagnostic performance of the SENSEI® laparoscopic tethered gamma probe for detecting SLNs
Diagnostic performance include sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV). Histopathological tumour status of lymph nodes excised based on the ePLND template will be used as reference standard.
Measured: Length of study finish - 6 Months
Overall ease of use of the SENSEI® laparoscopic tethered gamma probe.
Measured: Length of study finish - 6 Months
Radiation safety measurements for the staff.
Measured: Length of study finish - 6 Months
Duration of surgery
Outcome will be measured from the first skin incision to skin closure (skin to skin).
Measured: Length of study finish - 6 Months
In centres using a conventional rigid laparoscopic gamma probe:
SLN detection rate, number of SLNs, diagnostic performance and in vivo and ex vivo count rate of the SENSEI® laparoscopic tethered gamma probe in comparison to the conventional rigid laparoscopic gamma probe.
In centres using a conventional rigid laparoscopic gamma probe: Overall ease of use of the conventional rigid laparoscopic gamma probe
Measured: Length of study finish - 6 Months
Comparison of detection rates between robotic, open and manual laparoscopic surgery
Measured: Length of study finish - 6 Months
Incidence of study-related Adverse Events
Measured: Length of study finish - 6 Months
Complication rate as measured by Clavien-Dindo classification
Measured: Length of study finish - 6 Months
In centres using a conventional rigid laparoscopic gamma probe: Overall ease of use of the conventional rigid laparoscopic gamma probe
Outcome will be assessed using questionnaire and ethnographic observations, and at similar time points.
Measured: Length of study finish - 6 Months
Duration of Sentinel Lymph Node Biopsy separately for each probe used
Duration of SLNB will be measured from the first in vivo measurement to completion of ex vivo measurements of excised SLN specimens and measured separately for each probe used. The end time of ex vivo measurements of the excised ePLND specimens will also be recorded.
Measured: Length of study finish - 6 Months
Sentinel Lymph Node detection Rate
The 95% Confidence Interval (CI) around the detection rate will allow an estimate of the true detection rate. The sample size directly impacts the precision of the estimate. The sample size of 40 evaluable patients has been selected to provide a reasonable level of precision for the estimate of the SLN detection rate
Measured: Length of study finish - 6 Months
Number of Sentinel Lymph Nodes
Number of SLNs detected with the SENSEI® laparoscopic tethered gamma probe in comparison to preoperative planar LS and SPECT/CT in centres with a SPECT/CT scanner.
Measured: Length of study finish - 6 Months
Diagnostic performance and in vivo and ex vivo count rate of the SENSEI® laparoscopic tethered gamma probe in comparison to the conventional rigid laparoscopic gamma probe.
Measured: Length of study finish - 6 Months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Nov 2020
- Study start16 Sep 2020
- Primary completion16 Feb 2021 (estimated)
- Study completionAug 2021 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Prostate CancerStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 56 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Lightpoint Medical Limited
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04632251
- Sponsor's protocol ID
- LPM-012
- Acronym
- LPM-012
- Status last verified
- Nov 2020
- First submitted
- 21 Sep 2020
- Last updated
- 17 Nov 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Publications
Everaerts W, Walz J, Abascal Junquera JM, Goffin K, Grootendorst MR, van 't Klooster K, Juanpere N, Valhondo-Rama R, Vidal-Sicart S, Fumado L. A Multicentre Clinical Trial Evaluating a Drop-in Gamma Probe for Minimally Invasive Sentinel Lymph Node Dissection in Prostate Cancer. Eur Urol Focus. 2024 Jan;10(1):32-40. doi: 10.1016/j.euf.2023.07.001. Epub 2023 Jul 24.
PubMed 37495459Abascal Junquera JM, Harke NN, Walz JC, Hadaschik B, Adshead J, Everaerts W, Goffin K, Grootendorst MR, Oldfield F, Vyas K, Fusco AM, Juanpere N, Vidal-Sicart S, Fumado L. A Drop-in Gamma Probe for Minimally Invasive Sentinel Lymph Node Dissection in Prostate Cancer: Preclinical Evaluation and Interim Results From a Multicenter Clinical Trial. Clin Nucl Med. 2023 Mar 1;48(3):213-220. doi: 10.1097/RLU.0000000000004557. Epub 2023 Jan 14.
PubMed 36723880
Study at a glance
From the registry record, last updated by the sponsor on 17 Nov 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of the SENSEI® Laparoscopic Tethered Gamma Probe for 99mTc-nanocolloid Sentinel Lymph Node Biopsy in Prostate Cancer
- ClinicalTrials.gov ID
- NCT04632251
- Acronym / sponsor ID
- LPM-012 / LPM-012
- Conditions
- Prostate Cancer
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 56 participants (estimated)
- Lead sponsor
- Lightpoint Medical LimitedIndustry (pharma, biotech, devices)
- Study start
- 16 Sep 2020 (actual)
- Primary completion
- 16 Feb 2021 (estimated)
- Study completion
- Aug 2021 (estimated)
- First posted
- 17 Nov 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is a prospective, open label, single-arm study to examine the performance and safety of the SENSEI® laparoscopic tethered gamma probe in patients undergoing 99mTc-nanocolloid SLNB for prostate cancer (PCa) during RP and ePLND surgery.
Patients scheduled for RP and ePLND using the standard treatment pathways at each centre will have preoperative 99mTc-nanocolloid imaging. RP and ePLND will be conducted as standard of care, with SLNB guided by the SENSEI® laparoscopic tethered gamma probe carried out after RP and prior to ePLND. The first 2 patients per site (N = 10 in total) are considered to be sufficient to enable further familiarisation with the procedure and use of the probe in addition to the usability work and training that the sites did prior to the start of this study. Subsequent patients will be evaluable for the PP population. The primary analysis of diagnostic performance will be performed using the PP population of patients with SLN identified on preoperative imaging
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Familiarisation | Other | Device: SENSEI®The first 2 patients per site (N = 10 in total) are considered to be sufficient to enable further familiarisation with the procedure and use of the probe in addition to the usability work and training that the sites did prior to the start of this study. |
Who may qualify
- Ages
- 18 years and older
- Sex
- Male only
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Male subjects who are ≥ 18 years of age with histologically proven prostate cancer; and who have signed an informed consent form prior to any study related activity • Subjects who are scheduled for radical prostatectomy with ePLND.
Key exclusion criteria (5 listed)
- Subjects who have received prior prostate cancer treatment or prior pelvic surgery;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| SENSEI®SENSEI® laparoscopic tethered gamma probe is an intra-operative laparoscopic gamma probe system | Device | Familiarisation |
Primary outcome
Sentinel lymph node (SLN) detection rate with the SENSEI® laparoscopic tethered gamma probe. Detection rate is defined as the percentage of patients with at least one SLN detected intraoperatively.
Time frame: Length of study finish - 6 Months
14 secondary outcomes
Number of SLNs detected with the SENSEI® laparoscopic tethered gamma probe in comparison to preoperative planar LS and SPECT/CT in centres with a SPECT/CT scanner.
Time frame: Length of study finish - 6 Months
Diagnostic performance of the SENSEI® laparoscopic tethered gamma probe for detecting SLNs
Time frame: Length of study finish - 6 Months
Overall ease of use of the SENSEI® laparoscopic tethered gamma probe.
Time frame: Length of study finish - 6 Months
Radiation safety measurements for the staff.
Time frame: Length of study finish - 6 Months
Duration of surgery
Time frame: Length of study finish - 6 Months
In centres using a conventional rigid laparoscopic gamma probe:
Time frame: Length of study finish - 6 Months
Comparison of detection rates between robotic, open and manual laparoscopic surgery
Time frame: Length of study finish - 6 Months
Incidence of study-related Adverse Events
Time frame: Length of study finish - 6 Months
Complication rate as measured by Clavien-Dindo classification
Time frame: Length of study finish - 6 Months
In centres using a conventional rigid laparoscopic gamma probe: Overall ease of use of the conventional rigid laparoscopic gamma probe
Time frame: Length of study finish - 6 Months
Duration of Sentinel Lymph Node Biopsy separately for each probe used
Time frame: Length of study finish - 6 Months
Sentinel Lymph Node detection Rate
Time frame: Length of study finish - 6 Months
Number of Sentinel Lymph Nodes
Time frame: Length of study finish - 6 Months
Diagnostic performance and in vivo and ex vivo count rate of the SENSEI® laparoscopic tethered gamma probe in comparison to the conventional rigid laparoscopic gamma probe.
Time frame: Length of study finish - 6 Months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Nov 2020.
- Derived from this study: PubMed 37495459Everaerts W, Walz J, Abascal Junquera JM, Goffin K, Grootendorst MR, van 't Klooster K, Juanpere N, Valhondo-Rama R, Vidal-Sicart S, Fumado L. A Multicentre Clinical Trial Evaluating a Drop-in Gamma Probe for Minimally Invasive Sentinel Lymph Node Dissection in Prostate Cancer. Eur Urol Focus. 2024 Jan;10(1):32-40. doi: 10.1016/j.euf.2023.07.001. Epub 2023 Jul 24.
- Derived from this study: PubMed 36723880Abascal Junquera JM, Harke NN, Walz JC, Hadaschik B, Adshead J, Everaerts W, Goffin K, Grootendorst MR, Oldfield F, Vyas K, Fusco AM, Juanpere N, Vidal-Sicart S, Fumado L. A Drop-in Gamma Probe for Minimally Invasive Sentinel Lymph Node Dissection in Prostate Cancer: Preclinical Evaluation and Interim Results From a Multicenter Clinical Trial. Clin Nucl Med. 2023 Mar 1;48(3):213-220. doi: 10.1097/RLU.0000000000004557. Epub 2023 Jan 14.
Related trials for Prostate Cancer
Active, not recruiting
Streamlined Geriatric and Oncological Evaluation Based On IC Technology
Breast Cancer, Comorbidities and Coexisting Conditions
Active, not recruitingObservational study
MRI Fusion Biopsy vs. Micro-Ultrasound Guided Biopsy
Prostate Cancer
Enrolling by invitationObservational study
Natural History Study of Early Life Exposures in Agriculture (ELEA)
Prostate Cancer, Leukemia
Not yet recruitingPhase 1/2
STAR0602 With Nivolumab in Non Small Cell Lung Cancer and in Metastatic Castrate-Resistant Prostate Cancer, and STAR0602 Alone in Thymic Carcinoma
NSCLC, Non-Small Cell Lung Cancer
Recruiting
Rehabilitation and Sex Therapy to Optimize Recovery After Prostate Cancer Treatment
Prostate Cancer, Urinary Incontinence
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
4 sites in 4 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing SENSEI® in people with Prostate Cancer, run by Lightpoint Medical Limited at 4 sites in 4 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 17 Nov 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in Belgium, France, Germany, Spain. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Lluis Fumado Ciutat (+34 650 947 553, LFumado@parcdesalutmar.cat), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Sentinel lymph node (SLN) detection rate with the SENSEI® laparoscopic tethered gamma probe. Detection rate is defined as the percentage of patients with at least one SLN detected intraoperatively. (time frame: Length of study finish - 6 Months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04632251, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Nov 2020.